-
Electrostatic control of nonlinear photonic-crystal polaritons in a monolayer semiconductor
Authors:
Ekaterina Khestanova,
Vanik Shahnazaryan,
Valerii K. Kozin,
Valeriy I. Kondratyev,
Dmitry N. Krizhanovskii,
Maurice S. Skolnick,
Ivan A. Shelykh,
Ivan V. Iorsh,
Vasily Kravtsov
Abstract:
Integration of 2D semiconductors with photonic crystal slabs provides an attractive approach to achieve strong light--matter coupling and exciton-polariton formation in a planar chip-compatible geometry. However, for the development of practical devices, it is crucial that the polariton excitations in the structure are easily tunable and exhibit strong nonlinear response. Here we study neutral and…
▽ More
Integration of 2D semiconductors with photonic crystal slabs provides an attractive approach to achieve strong light--matter coupling and exciton-polariton formation in a planar chip-compatible geometry. However, for the development of practical devices, it is crucial that the polariton excitations in the structure are easily tunable and exhibit strong nonlinear response. Here we study neutral and charged exciton-polaritons in an electrostatically gated planar photonic crystal slab with an embedded monolayer semiconductor MoSe$_2$ and experimentally demonstrate strong polariton nonlinearity, which can be tuned via gate voltage. We find that modulation of dielectric environment within the photonic crystal results in the formation of two distinct resonances with significantly different nonlinear response, which enables optical switching with ultrashort laser pulses. Our results open new avenues towards development of active polaritonic devices in a compact chip-compatible implementation.
△ Less
Submitted 27 March, 2024; v1 submitted 25 February, 2024;
originally announced February 2024.
-
Exploring van der Waals materials with high anisotropy: geometrical and optical approaches
Authors:
Aleksandr S. Slavich,
Georgy A. Ermolaev,
Mikhail K. Tatmyshevskiy,
Adilet N. Toksumakov,
Olga G. Matveeva,
Dmitriy V. Grudinin,
Arslan Mazitov,
Konstantin V. Kravtsov,
Alexander V. Syuy,
Dmitry M. Tsymbarenko,
Mikhail S. Mironov,
Sergey M. Novikov,
Ivan Kruglov,
Davit A. Ghazaryan,
Andrey A. Vyshnevyy,
Aleksey V. Arsenin,
Valentyn S. Volkov,
Kostya S. Novoselov
Abstract:
The emergence of van der Waals (vdW) materials resulted in the discovery of their giant optical, mechanical, and electronic anisotropic properties, immediately enabling countless novel phenomena and applications. Such success inspired an intensive search for the highest possible anisotropic properties among vdW materials. Furthermore, the identification of the most promising among the huge family…
▽ More
The emergence of van der Waals (vdW) materials resulted in the discovery of their giant optical, mechanical, and electronic anisotropic properties, immediately enabling countless novel phenomena and applications. Such success inspired an intensive search for the highest possible anisotropic properties among vdW materials. Furthermore, the identification of the most promising among the huge family of vdW materials is a challenging quest requiring innovative approaches. Here, we suggest an easy-to-use method for such a survey based on the crystallographic geometrical perspective of vdW materials followed by their optical characterization. Using our approach, we found As2S3 as a highly anisotropic vdW material. It demonstrates rare giant in-plane optical anisotropy, high refractive index and transparency in the visible range, overcoming the century-long record set by rutile. Given these benefits, As2S3 opens a pathway towards next-generation nanophotonics as demonstrated by an ultrathin true zero-order quarter-waveplate that combines classical and the Fabry-Perot optical phase accumulations. Hence, our approach provides an effective and easy-to-use method to find vdW materials with the utmost anisotropic properties.
△ Less
Submitted 5 September, 2023;
originally announced September 2023.
-
Probing and control of guided exciton-polaritons in a 2D semiconductor-integrated slab waveguide
Authors:
Valeriy I. Kondratyev,
Dmitry V. Permyakov,
Tatyana V. Ivanova,
Ivan V. Iorsh,
Dmitry N. Krizhanovskii,
Maurice S. Skolnick,
Vasily Kravtsov,
Anton K. Samusev
Abstract:
Guided 2D exciton-polaritons, resulting from the strong coupling of excitons in semiconductors with non-radiating waveguide modes, provide an attractive approach towards develo** novel on-chip optical devices. These quasiparticles are characterized by long propagation distances and efficient nonlinear interaction but cannot be directly accessed from the free space. Here we demonstrate a powerful…
▽ More
Guided 2D exciton-polaritons, resulting from the strong coupling of excitons in semiconductors with non-radiating waveguide modes, provide an attractive approach towards develo** novel on-chip optical devices. These quasiparticles are characterized by long propagation distances and efficient nonlinear interaction but cannot be directly accessed from the free space. Here we demonstrate a powerful approach for probing and manipulating guided polaritons in a Ta2O5 slab integrated with a WS2 monolayer using evanescent coupling through a high-index solid immersion lens. Tuning the nanoscale lens-sample gap allows for extracting all the intrinsic parameters of the system. We also demonstrate the transition from weak to strong coupling accompanied by the onset of the motional narrowing effect: with the increase of exciton-photon coupling strength, the inhomogeneous contribution to polariton linewidth, inherited from the exciton resonance, becomes fully lifted. Our results enable the development of integrated optics employing room-temperature exciton-polaritons in 2D semiconductor-based structures.
△ Less
Submitted 28 September, 2023; v1 submitted 22 May, 2023;
originally announced May 2023.
-
Nonlinear self-action of ultrashort guided exciton-polariton pulses in dielectric slab coupled to 2D semiconductor
Authors:
F. A. Benimetskiy,
A. Yulin,
A. O. Mikhin,
V. Kravtsov,
I. Iorsh,
M. S. Skolnick,
I. A. Shelykh,
D. N. Krizhanovskii,
A. Samusev
Abstract:
Recently reported large values of exciton-polariton nonlinearity of transition metal dichalcogenide (TMD) monolayers coupled to optically resonant structures approach the values characteristic for GaAs-based systems in the regime of strong light-matter coupling. Contrary to the latter, TMD-based polaritonic devices remain operational at ambient conditions and therefore have greater potential for p…
▽ More
Recently reported large values of exciton-polariton nonlinearity of transition metal dichalcogenide (TMD) monolayers coupled to optically resonant structures approach the values characteristic for GaAs-based systems in the regime of strong light-matter coupling. Contrary to the latter, TMD-based polaritonic devices remain operational at ambient conditions and therefore have greater potential for practical nanophotonic applications. Here we present the study of the nonlinear properties of Ta$_2$O$_5$ slab waveguide coupled to a WSe$_2$ monolayer. We first confirm that the hybridization between waveguide photon mode and a 2D semiconductor exciton resonance gives rise to the formation of exciton-polaritons with Rabi splitting of 36 meV. By measuring transmission of ultrashort optical pulses through this TMD-based polaritonic waveguide, we demonstrate for the first time the strong nonlinear dependence of the output spectrum on the input pulse energy. Our theoretical model provides semi-quantitative agreement with experiment and gives insights into the dominating microscopic processes which determine the nonlinear pulse self-action: Coulomb inter-particle interaction and scattering to incoherent excitonic reservoir. We also confirm that at intermediate pump energies the system supports quasi-stationary solitonic regime of pulse propagation. Our results are essential for the development of nonlinear on-chip polaritonic devices based of 2D semiconductors.
△ Less
Submitted 8 May, 2022;
originally announced May 2022.
-
Entropy-Conserving Scheme for Modeling Nonthermal Energies in Fluid Dynamics Simulations
Authors:
Vadim A. Semenov,
Andrey V. Kravtsov,
Benedikt Diemer
Abstract:
We compare the performance of energy-based and entropy-conserving schemes for modeling nonthermal energy components, such as unresolved turbulence and cosmic rays, using idealized fluid dynamics tests and isolated galaxy simulations. While both methods are aimed to model advection and adiabatic compression or expansion of different energy components, the energy-based scheme numerically solves the…
▽ More
We compare the performance of energy-based and entropy-conserving schemes for modeling nonthermal energy components, such as unresolved turbulence and cosmic rays, using idealized fluid dynamics tests and isolated galaxy simulations. While both methods are aimed to model advection and adiabatic compression or expansion of different energy components, the energy-based scheme numerically solves the nonconservative equation for the energy density evolution, while the entropy-conserving scheme uses a conservative equation for modified entropy. Using the standard shock tube and Zel'dovich pancake tests, we show that the energy-based scheme results in a spurious generation of nonthermal energy on shocks, while the entropy-conserving method evolves the energy adiabatically to machine precision. We also show that, in simulations of an isolated $L_\star$ galaxy, switching between the schemes results in $\approx 20-30\%$ changes of the total star formation rate and a significant difference in morphology, particularly near the galaxy center. We also outline and test a simple method that can be used in conjunction with the entropy-conserving scheme to model the injection of nonthermal energies on shocks. Finally, we discuss how the entropy-conserving scheme can be used to capture the kinetic energy dissipated by numerical viscosity into the subgrid turbulent energy implicitly, without explicit source terms that require calibration and can be rather uncertain. Our results indicate that the entropy-conserving scheme is the preferred choice for modeling nonthermal energy components, a conclusion that is equally relevant for Eulerian and moving-mesh fluid dynamics codes.
△ Less
Submitted 13 May, 2022; v1 submitted 29 July, 2021;
originally announced July 2021.
-
Nonlinear polaritons in monolayer semiconductor coupled to optical bound states in the continuum
Authors:
V. Kravtsov,
E. Khestanova,
F. A. Benimetskiy,
T. Ivanova,
A. K. Samusev,
I. S. Sinev,
D. Pidgayko,
A. M. Mozharov,
I. S. Mukhin,
M. S. Lozhkin,
Y. V. Kapitonov,
A. S. Brichkin,
V. D. Kulakovskii,
I. A. Shelykh,
A. I. Tartakovskii,
P. M. Walker,
M. S. Skolnick,
D. N. Krizhanovskii,
I. V. Iorsh
Abstract:
Optical bound states in the continuum (BICs) provide a way to engineer very narrow resonances in photonic crystals. The extended interaction time in such systems is particularly promising for enhancement of nonlinear optical processes and development of the next generation of active optical devices. However, the achievable interaction strength is limited by the purely photonic character of optical…
▽ More
Optical bound states in the continuum (BICs) provide a way to engineer very narrow resonances in photonic crystals. The extended interaction time in such systems is particularly promising for enhancement of nonlinear optical processes and development of the next generation of active optical devices. However, the achievable interaction strength is limited by the purely photonic character of optical BICs. Here, we mix optical BIC in a photonic crystal slab with excitons in atomically thin semiconductor MoSe$_2$ to form nonlinear exciton-polaritons with a Rabi splitting of 27~meV, exhibiting large interaction-induced spectral blueshifts. The asymptotic BIC-like suppression of polariton radiation into far-field towards the BIC wavevector, in combination with effective reduction of excitonic disorder through motional narrowing, results in small polariton linewidths below 3~meV. Together with strongly wavevector-dependent Q-factor, this provides for enhancement and control of polariton--polariton interactions and resulting nonlinear optical effects, paving the way towards tunable BIC-based polaritonic devices for sensing, lasing, and nonlinear optics.
△ Less
Submitted 9 October, 2019; v1 submitted 31 May, 2019;
originally announced May 2019.
-
Enforcing the Courant-Friedrichs-Lewy Condition in Explicitly Conservative Local Time Step** Schemes
Authors:
Nickolay Y. Gnedin,
Vadim A. Semenov,
Andrey V. Kravtsov
Abstract:
An optimally efficient explicit numerical scheme for solving fluid dynamics equations, or any other parabolic or hyperbolic system of partial differential equations, should allow local regions to advance in time with their own, locally constrained time steps. However, such a scheme can result in violation of the Courant-Friedrichs-Lewy (CFL) condition, which is manifestly non-local. Although the v…
▽ More
An optimally efficient explicit numerical scheme for solving fluid dynamics equations, or any other parabolic or hyperbolic system of partial differential equations, should allow local regions to advance in time with their own, locally constrained time steps. However, such a scheme can result in violation of the Courant-Friedrichs-Lewy (CFL) condition, which is manifestly non-local. Although the violations can be considered to be "weak" in a certain sense and the corresponding numerical solution may be stable, such calculation does not guarantee the correct propagation speed for arbitrary waves. We use an experimental fluid dynamics code that allows cubic "patches" of grid cells to step with independent, locally constrained time steps to demonstrate how the CFL condition can be enforced by imposing a condition on the time steps of neighboring patches. We perform several numerical tests that illustrate errors introduced in the numerical solutions by weak CFL condition violations and show how strict enforcement of the CFL condition eliminates these errors. In all our tests the strict enforcement of the CFL condition does not impose a significant performance penalty.
△ Less
Submitted 9 January, 2018;
originally announced January 2018.
-
First measurement of muon-neutrino disappearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68%…
▽ More
This paper reports the first measurement using the NOvA detectors of $ν_μ$ disappearance in a $ν_μ$ beam. The analysis uses a 14 kton-equivalent exposure of $2.74 \times 10^{20}$ protons-on-target from the Fermilab NuMI beam. Assuming the normal neutrino mass hierarchy, we measure $Δm^{2}_{32}=(2.52^{+0.20}_{-0.18})\times 10^{-3}$ eV$^{2}$ and $\sin^2θ_{23}$ in the range 0.38-0.65, both at the 68% confidence level, with two statistically-degenerate best fit points at $\sin^2θ_{23} = $ 0.43 and 0.60. Results for the inverted mass hierarchy are also presented.
△ Less
Submitted 20 January, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
First measurement of electron neutrino appearance in NOvA
Authors:
P. Adamson,
C. Ader,
M. Andrews,
N. Anfimov,
I. Anghel,
K. Arms,
E. Arrieta-Diaz,
A. Aurisano,
D. S. Ayres,
C. Backhouse,
M. Baird,
B. A. Bambah,
K. Bays,
R. Bernstein,
M. Betancourt,
V. Bhatnagar,
B. Bhuyan,
J. Bian,
K. Biery,
T. Blackburn,
V. Bocean,
D. Bogert,
A. Bolshakova,
M. Bowden,
C. Bower
, et al. (235 additional authors not shown)
Abstract:
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a backg…
▽ More
We report results from the first search for $ν_μ\toν_e$ transitions by the NOvA experiment. In an exposure equivalent to $2.74\times10^{20}$ protons-on-target in the upgraded NuMI beam at Fermilab, we observe 6 events in the Far Detector, compared to a background expectation of $0.99\pm0.11$ (syst.) events based on the Near Detector measurement. A secondary analysis observes 11 events with a background of $1.07\pm0.14$ (syst.). The $3.3σ$ excess of events observed in the primary analysis disfavors $0.1π< δ_{CP} < 0.5π$ in the inverted mass hierarchy at the 90% C.L.
△ Less
Submitted 2 May, 2016; v1 submitted 19 January, 2016;
originally announced January 2016.
-
Hybrid tip-enhanced nano-spectroscopy and -imaging of monolayer WSe2 with local strain control
Authors:
Kyoung-Duck Park,
Omar Khatib,
Vasily Kravtsov,
Genevieve Clark,
Xiaodong Xu,
Markus B. Raschke
Abstract:
Many classes of two-dimensional (2D) materials have emerged as potential platforms for novel electronic and optical devices. However, the physical properties are strongly influenced by nanoscale heterogeneities in the form of edges, grain boundaries, and nucleation sites. Using combined tip-enhanced Raman scattering (TERS) and photoluminescence (TEPL) nano-spectroscopy and -imaging, we study the a…
▽ More
Many classes of two-dimensional (2D) materials have emerged as potential platforms for novel electronic and optical devices. However, the physical properties are strongly influenced by nanoscale heterogeneities in the form of edges, grain boundaries, and nucleation sites. Using combined tip-enhanced Raman scattering (TERS) and photoluminescence (TEPL) nano-spectroscopy and -imaging, we study the associated effects on the excitonic properties in monolayer WSe2 grown by physical vapor deposition (PVD). With <15 nm spatial resolution we resolve nonlocal nanoscale correlations of PL spectral intensity and shifts with crystal edges and internal twin boundaries associated with the expected exciton diffusion length. Through an active atomic force tip interaction we can control the crystal strain on the nanoscale, and tune the local bandgap in reversible (up to 24 meV shift) and irreversible (up to 48 meV shift) fashion. This allows us to distinguish the effect of strain from the dominant influence of defects on the PL modification at the different structural heterogeneities. Hybrid nano-optical and nano-mechanical imaging and spectroscopy thus enables the systematic study of the coupling of structural and mechanical degrees of freedom to the nanoscale electronic and optical properties in layered 2D materials.
△ Less
Submitted 6 January, 2016;
originally announced January 2016.
-
The T2K ND280 Off-Axis Pi-Zero Detector
Authors:
S. Assylbekov,
B. E. Berger,
H. Berns,
D. Beznosko,
A. Bodek,
R. Bradford,
N. Buchanan,
H. Budd,
Y. Caffari,
K. Connolly,
I. Danko,
R. Das,
S. Davis,
M. Day,
S. Dytman,
M. Dziomba,
R. Flight,
D. Forbush,
K. Gilje,
D. Hansen,
J. Hignight,
J. Imber,
R. A. Johnson,
C. K. Jung,
V. Kravtsov
, et al. (31 additional authors not shown)
Abstract:
The Pi-Zero detector (PØD) is one of the subdetectors that makes up the off-axis near detector for the Tokai-to-Kamioka (T2K) long baseline neutrino experiment. The primary goal for the PØD is to measure the relevant cross sections for neutrino interactions that generate pi-zero's, especially the cross section for neutral current pi-zero interactions, which are one of the dominant sources of backg…
▽ More
The Pi-Zero detector (PØD) is one of the subdetectors that makes up the off-axis near detector for the Tokai-to-Kamioka (T2K) long baseline neutrino experiment. The primary goal for the PØD is to measure the relevant cross sections for neutrino interactions that generate pi-zero's, especially the cross section for neutral current pi-zero interactions, which are one of the dominant sources of background to the electron neutrino appearance signal in T2K. The PØD is composed of layers of plastic scintillator alternating with water bags and brass sheets or lead sheets and is one of the first detectors to use Multi-Pixel Photon Counters (MPPCs) on a large scale.
△ Less
Submitted 28 June, 2012; v1 submitted 21 November, 2011;
originally announced November 2011.
-
Measurements of the T2K neutrino beam properties using the INGRID on-axis near detector
Authors:
K. Abe,
N. Abgrall,
Y. Ajima,
H. Aihara,
J. B. Albert,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
D. Autiero,
A. Badertscher,
M. Barbi,
G. J. Barker,
G. Barr,
M. Bass,
M. Batkiewicz,
F. Bay,
S. Bentham,
V. Berardi,
B. E. Berger
, et al. (407 additional authors not shown)
Abstract:
Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure o…
▽ More
Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure of iron target plates and scintillator trackers. INGRID directly monitors the muon neutrino beam profile center and intensity using the number of observed neutrino events in each module. The neutrino beam direction is measured with accuracy better than 0.4 mrad from the measured profile center. The normalized event rate is measured with 4% precision.
△ Less
Submitted 14 November, 2011;
originally announced November 2011.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.
-
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
Authors:
The PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
O. Wang,
H. Xu,
J. Becker,
F. Feldbauer,
F. -H. Heinsius,
T. Held,
H. Koch,
B. Kopf,
M. Pelizaeus,
T. Schroeder,
M. Steinke,
U. Wiedner,
J. Zhong,
A. Bianconi,
M. Bragadireanu,
D. Pantea
, et al. (387 additional authors not shown)
Abstract:
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and…
▽ More
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.
△ Less
Submitted 7 October, 2008;
originally announced October 2008.
-
Performance of a fine-sampling electromagnetic calorimeter prototype in the energy range from 1 to 19 GeV
Authors:
Yu. V. Kharlov,
P. A. Semenov,
Yu. A. Matulenko,
O. P. Yushchenko,
Yu. I. Arestov,
G. I. Britvich,
S. K. Chernichenko,
Yu. M. Goncharenko,
A. M. Davidenko,
A. A. Derevschikov,
A. S. Konstantinov,
V. A. Kormilitsyn,
V. I. Kravtsov,
Yu. M. Melnik,
A. P. Meschanin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
A. V. Ryazantsev,
I. V. Shein,
A. P. Soldatov,
L. F. Soloviev,
A. V. Soukhikh,
A. N. Vasiliev,
M. N. Ukhanov
, et al. (2 additional authors not shown)
Abstract:
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the cell. The lateral non-uniformi…
▽ More
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the cell. The lateral non-uniformity of the prototype energy response to electrons and MIPs has turned out to be negligible. Obtained experimental results are in a good agreement with Monte-Carlo simulations.
△ Less
Submitted 22 September, 2008;
originally announced September 2008.
-
Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
Authors:
V. A. Batarin,
J. Butler,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
V. Y. Khodyrev,
A. S. Konstantinov,
V. A. Kormilitsin,
V. I. Kravtsov,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov
, et al. (6 additional authors not shown)
Abstract:
A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved…
▽ More
A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.
△ Less
Submitted 29 September, 2005; v1 submitted 28 September, 2005;
originally announced September 2005.
-
Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
Authors:
V. A. Batarin,
J. Butler,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
A. S. Konstantinov,
V. I. Kravtsov,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov,
L. F. Soloviev,
S. Stone
, et al. (4 additional authors not shown)
Abstract:
Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic…
▽ More
Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystals recovery from such damage.
△ Less
Submitted 13 April, 2005;
originally announced April 2005.
-
Study of Possible Scintillation Mechanism Damage in PbWO4 Crystals After Pion Irradiation
Authors:
V. A. Batarin,
J. Butler,
T. Y. Chen,
A. M. Davidenko,
A. A. Derevschikov,
Y. M. Goncharenko,
V. N. Grishin,
V. A. Kachanov,
A. S. Konstantinov,
V. I. Kravtsov,
V. A. Kormilitsin,
Y. Kubota,
V. S. Lukanin,
Y. A. Matulenko,
Y. M. Melnick,
A. P. Meschanin,
N. E. Mikhalin,
N. G. Minaev,
V. V. Mochalov,
D. A. Morozov,
L. V. Nogach,
A. V. Ryazantsev,
P. A. Semenov,
V. K. Semenov,
K. E. Shestermanov
, et al. (6 additional authors not shown)
Abstract:
We employed two independent methods to study possible damage to the scintillation mechanism in lead tungstate crystals due to irradiation by a 34 GeV pion beam. First, 10 crystals were irradiated simultaneously over 30 hours by a narrow beam, so that only a small region of each crystal was affected. We studied the effect of the irradiation on the light output non-uniformity. If a localized degra…
▽ More
We employed two independent methods to study possible damage to the scintillation mechanism in lead tungstate crystals due to irradiation by a 34 GeV pion beam. First, 10 crystals were irradiated simultaneously over 30 hours by a narrow beam, so that only a small region of each crystal was affected. We studied the effect of the irradiation on the light output non-uniformity. If a localized degradation was observed, it would indicate damage to the scintillation mechanism. Secondly, we detected light output using two phototubes attached to sides of a crystal. Since these phototubes detect scintillation light only from a small localized region, the effect of transmission loss should be minimal. We did not see any statistically significant evidence for scintillation mechanism damage with either method. The effect is consistent with zero, and the upper limit is 0.5% at 95% C.L.
△ Less
Submitted 22 October, 2004; v1 submitted 19 October, 2004;
originally announced October 2004.
-
Comparison of Radiation Damage in Lead Tungstate Crystals under Pion and Gamma Irradiation
Authors:
V. Batarin,
J. Butler,
T. Chen,
A. Davidenko,
A. Derevschikov,
Y. Goncharenko,
V. Grishin,
V. Kachanov,
V. Khodyrev,
A. Konstantinov,
V. Kravtsov,
Y. Kubota,
V. Lukanin,
Y. Matulenko,
Y. Melnick,
A. Meschanin,
N. Mikhalin,
N. Minaev,
V. Mochalov,
D. Morozov,
L. Nogach,
A. Ryazantsev,
P. Semenov,
V. Semenov,
K. Shestermanov
, et al. (6 additional authors not shown)
Abstract:
Studies of the radiation hardness of lead tungstate crystals produced by the Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of Ceramics in China have been carried out at IHEP, Protvino. The crystals were irradiated by a 40-GeV pion beam. After full recovery, the same crystals were irradiated using a $^{137}Cs$ $γ$-ray source. The dose rate profiles along the crystal lengt…
▽ More
Studies of the radiation hardness of lead tungstate crystals produced by the Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of Ceramics in China have been carried out at IHEP, Protvino. The crystals were irradiated by a 40-GeV pion beam. After full recovery, the same crystals were irradiated using a $^{137}Cs$ $γ$-ray source. The dose rate profiles along the crystal length were observed to be quite similar. We compare the effects of the two types of radiation on the crystals light output.
△ Less
Submitted 28 April, 2004; v1 submitted 10 December, 2003;
originally announced December 2003.
-
LED Monitoring System for the BTeV Lead Tungstate Crystal Calorimeter Prototype
Authors:
V. Batarin,
J. Butler,
A. Davidenko,
A. Derevschikov,
Y. Goncharenko,
V. Grishin,
V. Kachanov,
A. Konstantinov,
V. Kravtsov,
V. Kormilitsin,
Y. Kubota,
Y. Matulenko,
V. Medvedev,
Y. Melnick,
A. Meschanin,
N. Mikhalin,
N. Minaev,
V. Mochalov,
D. Morozov,
L. Nogach,
A. Ryazantsev,
P. Semenov,
V. Semenov,
K. Shestermanov,
L. Soloviev
, et al. (6 additional authors not shown)
Abstract:
We report on the performance of a monitoring system for a prototype calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled with photomultiplier tubes. The tests were carried out at the 70 GeV accelerator complex at Protvino, Russia.
We report on the performance of a monitoring system for a prototype calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled with photomultiplier tubes. The tests were carried out at the 70 GeV accelerator complex at Protvino, Russia.
△ Less
Submitted 8 July, 2004; v1 submitted 25 November, 2003;
originally announced November 2003.
-
Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams
Authors:
V. Batarin,
T. Brennan,
J. Butler,
H. Cheung,
V. Datsko,
A. Davidenko,
A. Derevschikov,
R. Dzhelyadin,
Y. Fomin,
V. Frolov,
Y. Goncharenko,
V. Grishin,
V. Kachanov,
V. Khodyrev,
K. Khroustalev,
A. Konoplyannikov,
A. Konstantinov,
V. Kravtsov,
Y. Kubota,
V. Leontiev,
V. Lukanin,
V. Maisheev,
Y. Matulenko,
Y. Melnick,
A. Meschanin
, et al. (18 additional authors not shown)
Abstract:
We report on the effects of radiation on the light output of lead tungstate crystals. The crystals were irradiated by pure, intense high energy electron and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai (China). These studies were carried out at the 70-GeV proton accelerator in Protvino.
We report on the effects of radiation on the light output of lead tungstate crystals. The crystals were irradiated by pure, intense high energy electron and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai (China). These studies were carried out at the 70-GeV proton accelerator in Protvino.
△ Less
Submitted 5 October, 2002;
originally announced October 2002.
-
Precision Measurement of Energy and Position Resolutions of the BTeV Electromagnetic Calorimeter Prototype
Authors:
V. Batarin,
T. Brennan,
J. Butler,
H. Cheung,
A. Derevschikov,
Y. Fomin,
V. Frolov,
Y. Goncharenko,
V. Grishin,
V. Kachanov,
V. Khodyrev,
K. Khroustalev,
A. Konstantinov,
V. Kravtsov,
Y. Kubota,
V. Leontiev,
V. Maisheev,
Y. Matulenko,
Y. Melnick,
A. Meschanin,
N. Mikhalin,
N. Minaev,
V. Mochalov,
D. Morozov,
R. Mountain
, et al. (12 additional authors not shown)
Abstract:
The energy dependence of the energy and position resolutions of the electromagnetic calorimeter prototype made of lead tungstate crystals produced in Bogoroditsk (Russia) and Shanghai (China) is presented. These measurementswere carried out at the Protvino accelerator using a 1 to 45 GeV electron beam. The crystals were coupled to photomultiplier tubes. The dependence of energy and position reso…
▽ More
The energy dependence of the energy and position resolutions of the electromagnetic calorimeter prototype made of lead tungstate crystals produced in Bogoroditsk (Russia) and Shanghai (China) is presented. These measurementswere carried out at the Protvino accelerator using a 1 to 45 GeV electron beam. The crystals were coupled to photomultiplier tubes. The dependence of energy and position resolutions on different factors as well as the measured electromagnetic shower lateral profile are presented.
△ Less
Submitted 5 November, 2002; v1 submitted 21 September, 2002;
originally announced September 2002.
-
Adaptive Refinement Tree - a new high-resolution N-body code for cosmological simulations
Authors:
Andrey V. Kravtsov,
Anatoly A. Klypin,
Alexei M. Khokhlov
Abstract:
We present a new high-resolution N-body algorithm for cosmological simulations. The algorithm employs a traditional particle-mesh technique on a cubic grid and successive multilevel relaxations on the finer meshes, introduced recursively in a fully adaptive manner in the regions where the density exceeds a predefined threshold. The mesh is generated to effectively match an arbitrary geometry of…
▽ More
We present a new high-resolution N-body algorithm for cosmological simulations. The algorithm employs a traditional particle-mesh technique on a cubic grid and successive multilevel relaxations on the finer meshes, introduced recursively in a fully adaptive manner in the regions where the density exceeds a predefined threshold. The mesh is generated to effectively match an arbitrary geometry of the underlying density field -- a property particularly important for cosmological simulations. In a simulation the mesh structure is not created at every time step but is properly adjusted to the evolving particle distribution. The algorithm is fast and effectively parallel. We present a detailed description of the methodology, implementation, and tests of the code.
We further use the code to study the structure of dark matter halos in high-resolution (2/h kpc) simulations of standard CDM (Omega=1, h=0.5, sigma_8=0.63) and LCDM (Omega_Lambda=1-Omega_0=0.7, h=0.7, sigma_8=1.0) models. We find that halo density profiles in both CDM and LCDM models are well fitted by the analytical model presented recently by Navarro et al., which predicts a singular [$ρ(r)\propto r^{-1}$] behavior of the halo density profiles at small radii. We therefore conclude that halos formed in the $Λ$CDM model have structure similar to CDM halos and thus cannot explain the dynamics of the central parts of dwarf spiral galaxies, as inferred from the galaxies' rotation curves.
△ Less
Submitted 28 July, 1997; v1 submitted 24 January, 1997;
originally announced January 1997.