-
The Design, Implementation, and Performance of the LZ Calibration Systems
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (179 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e…
▽ More
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.
△ Less
Submitted 20 June, 2024; v1 submitted 2 May, 2024;
originally announced June 2024.
-
The Data Acquisition System of the LZ Dark Matter Detector: FADR
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (190 additional authors not shown)
Abstract:
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.…
▽ More
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis.
The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition.
The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
J. Bang,
J. W. Bargemann,
A. Baxter,
K. Beattie,
P. Beltrame,
E. P. Bernard,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger,
B. Boxer
, et al. (178 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet…
▽ More
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-beta decay searches and effective field theory interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations of bulk and fixed radioactive backgrounds are consistent with expectations from the ex-situ assays. The observed background rate after WIMP search criteria were applied was $(6.3\pm0.5)\times10^{-5}$ events/keV$_{ee}$/kg/day in the low-energy region, approximately 60 times lower than the equivalent rate reported by the LUX experiment.
△ Less
Submitted 17 July, 2023; v1 submitted 30 November, 2022;
originally announced November 2022.
-
Improved Dark Matter Search Sensitivity Resulting from LUX Low-Energy Nuclear Recoil Calibration
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (72 additional authors not shown)
Abstract:
Dual-phase xenon time projection chamber (TPC) detectors have demonstrated superior search sensitivities to dark matter over a wide range of particle masses. To extend their sensitivity to include low-mass dark matter interactions, it is critical to characterize both the light and charge responses of liquid xenon to sub-keV nuclear recoils. In this work, we report a new nuclear recoil calibration…
▽ More
Dual-phase xenon time projection chamber (TPC) detectors have demonstrated superior search sensitivities to dark matter over a wide range of particle masses. To extend their sensitivity to include low-mass dark matter interactions, it is critical to characterize both the light and charge responses of liquid xenon to sub-keV nuclear recoils. In this work, we report a new nuclear recoil calibration in the LUX detector $\textit{in situ}$ using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator. We demonstrate direct measurements of light and charge yields down to 0.45 keV (1.4 scintillation photons) and 0.27 keV (1.3 ionization electrons), respectively, approaching the physical limit of liquid xenon detectors. We discuss the implication of these new measurements on the physics reach of dual-phase xenon TPCs for nuclear-recoil-based low-mass dark matter detection.
△ Less
Submitted 14 October, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Report of the Instrumentation Frontier Working Group for Snowmass 2021
Authors:
Phillip S. Barbeau,
Petra Merkel,
**long Zhang,
Darin Acosta,
Anthony A. Affolder,
Artur Apresyan,
Marina Artuso,
Vallary Bhopatkar,
Stephen Butalla,
Gabriella A. Carini,
Thomas Cecil,
Amy Connolly,
C. Eric Dahl,
Allison Deiana,
Katherine Dunne,
Carlos O. Escobar,
Juan Estrada,
Farah Fahim,
James E. Fast,
Maurice Garcia-Sciveres,
Roxanne Guenette,
Michael T. Hedges,
Kent Irwin,
Albrecht Karle,
Wes Ketchum
, et al. (20 additional authors not shown)
Abstract:
Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technol…
▽ More
Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.
△ Less
Submitted 3 November, 2022; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors
Authors:
Carl Eric Dahl,
Roxanne Guenette,
Jennifer L. Raaf,
D. Akerib,
J. Asaadi,
D. Caratelli,
E. Church,
M. Del Tutto,
A. Fava,
R. Gaitskell,
G. K. Giovanetti,
G. Giroux,
D. Gonzalez Diaz,
E. Gramellini,
S. Haselschwardt,
C. Jackson,
B. J. P. Jones,
A. Kopec,
S. Kravitz,
H. Lippincott,
J. Liu,
C. J. Martoff,
A. Mastbaum,
C. Montanari,
M. Mooney
, et al. (17 additional authors not shown)
Abstract:
Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particl…
▽ More
Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particle detectors. As these experiments seek to increase their sensitivity, novel and improved technologies will be needed to enhance the precision of their measurements and to broaden the reach of their physics programs. The areas of R&D in noble element instrumentation that have been identified by the HEP community in the Snowmass process are highlighted by five key messages: IF08-1) Enhance and combine existing modalities (scintillation and electron drift) to increase signal-to-noise and reconstruction fidelity; IF08-2) Develop new modalities for signal detection in noble elements, including methods based on ion drift, metastable fluids, solid-phase detectors and dissolved targets. Collaborative and blue-sky R&D should also be supported to enable advances in this area; IF08-3) Improve the understanding of detector microphysics and calibrate detector response in new signal regimes; IF08-4) Address challenges in scaling technologies, including material purification, background mitigation, large-area readout, and magnetization; and IF08-5) Train the next generation of researchers, using fast-turnaround instrumentation projects to provide the design-through-result training no longer possible in very-large-scale experiments. This topical group report identifies and documents recent developments and future needs for noble element detector technologies. In addition, we highlight the opportunity that this area of research provides for continued training of the next generation of scientists.
△ Less
Submitted 15 September, 2022; v1 submitted 23 August, 2022;
originally announced August 2022.
-
Study of dielectric breakdown in liquid xenon with the XeBrA experiment
Authors:
J. Watson,
I. Olcina,
J. Soria,
D. N. McKinsey,
S. Kravitz,
E. E. Deck,
E. P. Bernard,
L. Tvrznikova,
W. L. Waldron,
Q. Riffard,
K. O'Sullivan
Abstract:
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment.…
▽ More
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a five-liter, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both anode current and photon rate was observed in the last 30 seconds leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler-Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.
△ Less
Submitted 31 October, 2022; v1 submitted 15 June, 2022;
originally announced June 2022.
-
Transforming U.S. Particle Physics Education: A Snowmass 2021 Study
Authors:
O. Bitter,
E. V. Hansen,
S. Kravitz,
V. Velan,
Y. You
Abstract:
The pursuit of knowledge in particle physics requires constant learning. As new tools become available, new theories are developed, and physicists search for new answers with ever-evolving methods. However, it is the case that formal educational systems serve as the primary training grounds for particle physicists. Graduate school (and undergraduate school to a lesser extent) is where researchers…
▽ More
The pursuit of knowledge in particle physics requires constant learning. As new tools become available, new theories are developed, and physicists search for new answers with ever-evolving methods. However, it is the case that formal educational systems serve as the primary training grounds for particle physicists. Graduate school (and undergraduate school to a lesser extent) is where researchers learn most of the technical skills required for research, develop scientific problem-solving abilities, learn how to establish themselves in their field, and begin develo** their career. It is unfortunate, then, that the skills gained by physicists during their formal education are often mismatched with the skills actually required for a successful career in physics. We performed a survey of the U.S. particle physics community to determine the missing elements of graduate and undergraduate education and to gauge how to bridge these gaps. In this contributed paper, part of the 2021-22 Snowmass Community Planning Exercise, we report the results of this survey. We also recommend several specific community actions to improve the quality of particle physics education; the "community" here refers to physics departments, national labs, professional societies, funding agencies, and individual physicists.
△ Less
Submitted 19 April, 2022;
originally announced April 2022.
-
Dark-matter And Neutrino Computation Explored (DANCE) Community Input to Snowmass
Authors:
Amy Roberts,
Christopher Tunnell,
Belina von Krosigk,
Tyler Anderson,
Jason Brodsky,
Micah Buuck,
Tina Cartaro,
Melissa Cragin,
Gavin S. Davies,
Miriam Diamond,
Alden Fan,
Aaron Higuera,
Valerio Ippolito,
Chris Jillings,
Scott Kravitz,
Luke Krezko,
Ivy Li,
Maria Elena Monzani,
Igor Ostrovskiy,
Fernanda Psihas,
Andrew Renshaw,
Quentin Riffard,
Joel Sander,
Samuele Sangiorgio,
Reto Trappitsch
, et al. (1 additional authors not shown)
Abstract:
This paper summarizes the needs of the dark matter and neutrino communities as it relates to computation. The scope includes data acquisition, triggers, data management and processing, data preservation, simulation, machine learning, data analysis, software engineering, career development, and equity and inclusion. Beyond identifying our community needs, we propose actions that can be taken to str…
▽ More
This paper summarizes the needs of the dark matter and neutrino communities as it relates to computation. The scope includes data acquisition, triggers, data management and processing, data preservation, simulation, machine learning, data analysis, software engineering, career development, and equity and inclusion. Beyond identifying our community needs, we propose actions that can be taken to strengthen this community and to work together to overcome common challenges.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Snowmass2021 Cosmic Frontier: Modeling, statistics, simulations, and computing needs for direct dark matter detection
Authors:
Yonatan Kahn,
Maria Elena Monzani,
Kimberly J. Palladino,
Tyler Anderson,
Deborah Bard,
Daniel Baxter,
Micah Buuck,
Concetta Cartaro,
Juan I. Collar,
Miriam Diamond,
Alden Fan,
Simon Knapen,
Scott Kravitz,
Rafael F. Lang,
Benjamin Nachman,
Ibles Olcina Samblas,
Igor Ostrovskiy,
Aditya Parikh,
Quentin Riffard,
Amy Roberts,
Kelly Stifter,
Matthew Szydagis,
Christopher Tunnell,
Belina von Krosigk,
Dennis Wright
, et al. (12 additional authors not shown)
Abstract:
This paper summarizes the modeling, statistics, simulation, and computing needs of direct dark matter detection experiments in the next decade.
This paper summarizes the modeling, statistics, simulation, and computing needs of direct dark matter detection experiments in the next decade.
△ Less
Submitted 27 December, 2022; v1 submitted 15 March, 2022;
originally announced March 2022.
-
Software and Computing for Small HEP Experiments
Authors:
Dave Casper,
Maria Elena Monzani,
Benjamin Nachman,
Costas Andreopoulos,
Stephen Bailey,
Deborah Bard,
Wahid Bhimji,
Giuseppe Cerati,
Grigorios Chachamis,
Jacob Daughhetee,
Miriam Diamond,
V. Daniel Elvira,
Alden Fan,
Krzysztof Genser,
Paolo Girotti,
Scott Kravitz,
Robert Kutschke,
Vincent R. Pascuzzi,
Gabriel N. Perdue,
Erica Snider,
Elizabeth Sexton-Kennedy,
Graeme Andrew Stewart,
Matthew Szydagis,
Eric Torrence,
Christopher Tunnell
Abstract:
This white paper briefly summarized key conclusions of the recent US Community Study on the Future of Particle Physics (Snowmass 2021) workshop on Software and Computing for Small High Energy Physics Experiments.
This white paper briefly summarized key conclusions of the recent US Community Study on the Future of Particle Physics (Snowmass 2021) workshop on Software and Computing for Small High Energy Physics Experiments.
△ Less
Submitted 27 December, 2022; v1 submitted 15 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber
Authors:
S. Kravitz,
H. Chen,
R. Gibbons,
S. J. Haselschwardt,
Q. Xia,
P. Sorensen
Abstract:
We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to tag and reject radon-chain backgrounds, due to t…
▽ More
We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to tag and reject radon-chain backgrounds, due to the time and energy signature of their decays. The present article is the first demonstration of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.
△ Less
Submitted 29 March, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
N. Carrara,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
J. Ernst,
A. Fan,
S. Fiorucci
, et al. (75 additional authors not shown)
Abstract:
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations betwe…
▽ More
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. This technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.
△ Less
Submitted 17 October, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Machine Learning in the Search for New Fundamental Physics
Authors:
Georgia Karagiorgi,
Gregor Kasieczka,
Scott Kravitz,
Benjamin Nachman,
David Shih
Abstract:
Machine learning plays a crucial role in enhancing and accelerating the search for new fundamental physics. We review the state of machine learning methods and applications for new physics searches in the context of terrestrial high energy physics experiments, including the Large Hadron Collider, rare event searches, and neutrino experiments. While machine learning has a long history in these fiel…
▽ More
Machine learning plays a crucial role in enhancing and accelerating the search for new fundamental physics. We review the state of machine learning methods and applications for new physics searches in the context of terrestrial high energy physics experiments, including the Large Hadron Collider, rare event searches, and neutrino experiments. While machine learning has a long history in these fields, the deep learning revolution (early 2010s) has yielded a qualitative shift in terms of the scope and ambition of research. These modern machine learning developments are the focus of the present review.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
-
Measurement of the Angular Distribution of Wavelength-Shifted Light Emitted by TPB
Authors:
Jackson Schrott,
Michinari Sakai,
Samuel Naugle,
Gabriel Orebi Gann,
Scott Kravitz,
Daniel McKinsey,
Ryan Smith
Abstract:
We present measurements of the angular distribution of re-emitted light from tetraphenyl butadiene thin films when exposed to \SI{128}{nm} light in vacuum. Films ranging from \SI{250}{nm} to \SI{5.5}{\micron} in thickness are measured. All films were fabricated by evaporation deposition on ultraviolet transmitting (UVT) acrylic substrates. Preliminary comparisons of the angular distribution to tha…
▽ More
We present measurements of the angular distribution of re-emitted light from tetraphenyl butadiene thin films when exposed to \SI{128}{nm} light in vacuum. Films ranging from \SI{250}{nm} to \SI{5.5}{\micron} in thickness are measured. All films were fabricated by evaporation deposition on ultraviolet transmitting (UVT) acrylic substrates. Preliminary comparisons of the angular distribution to that produced by a detailed Monte Carlo model are also presented. The current shortcomings of the model are discussed and future plans briefly outlined.
△ Less
Submitted 27 October, 2021; v1 submitted 18 August, 2021;
originally announced August 2021.
-
Scintillation yield from electronic and nuclear recoils in superfluid $^4$He
Authors:
SPICE/HeRALD Collaboration,
:,
A. Biekert,
C. Chang,
C. W. Fink,
M. Garcia-Sciveres,
E. C. Glazer,
W. Guo,
S. A. Hertel,
S. Kravitz,
J. Lin,
M. Lisovenko,
R. Mahapatra,
D. N. McKinsey,
J. S. Nguyen,
V. Novosad,
W. Page,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Pyle,
R. K. Romani,
A. S. Seilnacht,
A. Serafin,
R. J. Smith
, et al. (9 additional authors not shown)
Abstract:
Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~c…
▽ More
Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090 keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. We also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.
△ Less
Submitted 14 May, 2022; v1 submitted 4 August, 2021;
originally announced August 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber
Authors:
R. Linehan,
R. L. Mannino,
A. Fan,
C. M. Ignarra,
S. Luitz,
K. Skarpaas,
T. A. Shutt,
D. S. Akerib,
S. K. Alsum,
T. J. Anderson,
H. M. Araújo,
M. Arthurs,
H. Auyeung,
A. J. Bailey,
T. P. Biesiadzinski,
M. Breidenbach,
J. J. Cherwinka,
R. A. Conley,
J. Genovesi,
M. G. D. Gilchriese,
A. Glaenzer,
T. G. Gonda,
K. Hanzel,
M. D. Hoff,
W. Ji
, et al. (24 additional authors not shown)
Abstract:
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of th…
▽ More
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.
△ Less
Submitted 11 June, 2021;
originally announced June 2021.
-
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of $^{134}$Xe
Authors:
The LUX-ZEPLIN,
Collaboration,
:,
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araujo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert
, et al. (172 additional authors not shown)
Abstract:
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity t…
▽ More
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of $^{134}$Xe, for which xenon detectors enriched in $^{136}$Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7$\times$10$^{24}$ years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7$\times$10$^{23}$ years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3$\times$10$^{24}$ years at 90% CL.
△ Less
Submitted 22 November, 2021; v1 submitted 26 April, 2021;
originally announced April 2021.
-
Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals
Authors:
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger
, et al. (162 additional authors not shown)
Abstract:
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matt…
▽ More
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Drop** the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In…
▽ More
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In this regime, extra precaution is required to reject a complex set of low-energy electron backgrounds that have long been observed in this class of detector. Noticing backgrounds from the wire grid electrodes near the top and bottom of the active target are particularly pernicious, we develop a machine learning technique based on ionization pulse shape to identify and reject these events. We demonstrate the technique can improve Poisson limits on low-mass DM interactions by a factor of $2$-$7$ with improvement depending heavily on the size of ionization signals. We use the technique on events in an effective $5$ tonne$\cdot$day exposure from LUX's 2013 science operation to place strong limits on low-mass DM particles with masses in the range $m_χ\in0.15$-$10$ GeV. This machine learning technique is expected to be useful for near-future experiments, such as LZ and XENONnT, which hope to perform low-mass DM searches with the stringent background control necessary to make a discovery.
△ Less
Submitted 18 November, 2020;
originally announced November 2020.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
Investigation of background electron emission in the LUX detector
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese,
C. Gwilliam
, et al. (71 additional authors not shown)
Abstract:
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX…
▽ More
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments.
△ Less
Submitted 13 October, 2020; v1 submitted 16 April, 2020;
originally announced April 2020.
-
Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (72 additional authors not shown)
Abstract:
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclea…
▽ More
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of $\sim$100 keV, we observe an electronic recoil background acceptance of $<10^{-5}$ at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300 V/cm over the range of fields explored in this study (50-500 V/cm). In the WIMP search region of S1 = 1-80 phd, the minimum electronic recoil leakage we observe is ${(7.3\pm0.6)\times10^{-4}}$, which is obtained for a drift field of 240-290 V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique (NEST) simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.
△ Less
Submitted 9 December, 2020; v1 submitted 14 April, 2020;
originally announced April 2020.
-
Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
The LUX-ZEPLIN Collaboration,
:,
D. S. Akerib,
C. W. Akerlof,
A. Alqahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
D. Bauer,
A. Baxter,
J. Bensinger,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
K. E. Boast
, et al. (173 additional authors not shown)
Abstract:
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of par…
▽ More
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.
△ Less
Submitted 23 June, 2020; v1 submitted 25 January, 2020;
originally announced January 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Measurements of Angle-Resolved Reflectivity of PTFE in Liquid Xenon with IBEX
Authors:
S. Kravitz,
R. J. Smith,
L. Hagaman,
E. P. Bernard,
D. N. McKinsey,
L. Rudd,
L. Tvrznikova,
G. D. Orebi Gann,
M. Sakai
Abstract:
Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off P…
▽ More
Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.
△ Less
Submitted 30 March, 2020; v1 submitted 18 September, 2019;
originally announced September 2019.
-
Direct comparison of high voltage breakdown measurements in liquid argon and liquid xenon
Authors:
L. Tvrznikova,
E. P. Bernard,
S. Kravitz,
K. O'Sullivan,
G. Richardson,
Q. Riffard,
W. L. Waldron,
J. Watson,
D. N. McKinsey
Abstract:
As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon Breakdown Apparatus (XeBrA) is a 5-liter cryogenic chamber built to characterize the DC high voltage breakdown behavior of liquid xenon and liquid argon. Electrode…
▽ More
As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon Breakdown Apparatus (XeBrA) is a 5-liter cryogenic chamber built to characterize the DC high voltage breakdown behavior of liquid xenon and liquid argon. Electrodes with areas up to 33~cm$^2$ were tested while varying the cathode-anode separation from 1 to 6~mm with a voltage difference up to 75~kV. A power-law relationship between breakdown field and electrode area was observed. The breakdown behavior of liquid argon and liquid xenon within the same experimental apparatus was comparable.
△ Less
Submitted 16 December, 2019; v1 submitted 19 August, 2019;
originally announced August 2019.
-
Extending light WIMP searches to single scintillation photons in LUX
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
L. de Viveiros,
A. Dobi
, et al. (100 additional authors not shown)
Abstract:
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its…
▽ More
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
△ Less
Submitted 27 December, 2019; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
A. Baxter,
E. P. Bernard,
A. Biekert,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
M. C. Carmona-Benitez,
M. Cascella
, et al. (142 additional authors not shown)
Abstract:
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located with…
▽ More
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ $γ$-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of $1.9\pm0.4$~$γ~$cm$^{-2}$s$^{-1}$. The resulting activity in the walls of the cavern can be characterised as $220\pm60$~Bq/kg of $^{40}$K, $29\pm15$~Bq/kg of $^{238}$U, and $13\pm3$~Bq/kg of $^{232}$Th.
△ Less
Submitted 14 November, 2019; v1 submitted 3 April, 2019;
originally announced April 2019.
-
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi
, et al. (76 additional authors not shown)
Abstract:
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
△ Less
Submitted 7 June, 2019; v1 submitted 29 March, 2019;
originally announced March 2019.
-
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electr…
▽ More
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
△ Less
Submitted 16 October, 2019; v1 submitted 27 November, 2018;
originally announced November 2018.
-
Search for annual and diurnal rate modulations in the LUX experiment
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (71 additional authors not shown)
Abstract:
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calen…
▽ More
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and develo** robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$σ$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
△ Less
Submitted 27 September, 2018; v1 submitted 18 July, 2018;
originally announced July 2018.
-
Study of Silicon Photomultiplier Performance in External Electric Fields
Authors:
X. L. Sun,
T. Tolba,
G. F. Cao,
P. Lv,
L. J. Wen,
A. Odian,
F. Vachon,
A. Alamre,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois
, et al. (127 additional authors not shown)
Abstract:
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estima…
▽ More
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before drop** abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
Authors:
A. Jamil,
T. Ziegler,
P. Hufschmidt,
G. Li,
L. Lupin-Jimenez,
T. Michel,
I. Ostrovskiy,
F. Retière,
J. Schneider,
M. Wagenpfeil,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers
, et al. (118 additional authors not shown)
Abstract:
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting t…
▽ More
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
△ Less
Submitted 13 March, 2019; v1 submitted 6 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
Authors:
S. Delaquis,
M. J. Jewell,
I. Ostrovskiy,
M. Weber,
T. Ziegler,
J. Dalmasson,
L. J. Kaufman,
T. Richards,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels
, et al. (69 additional authors not shown)
Abstract:
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what…
▽ More
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.
△ Less
Submitted 30 August, 2018; v1 submitted 25 April, 2018;
originally announced April 2018.
-
LUX Trigger Efficiency
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (72 additional authors not shown)
Abstract:
The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this paper, the trigger efficiency, which is defined as the probability that an event of interest is selected for offline analysis, is studied using raw data obtained from both electron recoil (ER) and nuclear recoil (NR) calibr…
▽ More
The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this paper, the trigger efficiency, which is defined as the probability that an event of interest is selected for offline analysis, is studied using raw data obtained from both electron recoil (ER) and nuclear recoil (NR) calibrations. The measured efficiency exceeds 98\% at a pulse area of 90 detected photons, which is well below the WIMP analysis threshold on the S2 pulse area. The efficiency also exceeds 98\% at recoil energies of \mbox{0.2 keV} and above for ER, and \mbox{1.3 keV} and above for NR. The measured trigger efficiency varies between 99\% and 100\% over the fiducial volume of the detector.
△ Less
Submitted 4 September, 2018; v1 submitted 21 February, 2018;
originally announced February 2018.
-
Distributed Imaging for Liquid Scintillation Detectors
Authors:
Jacopo Dalmasson,
Giorgio Gratta,
Ako Jamil,
Scott Kravitz,
Milad Malek,
Kevin Wells,
Julie Bentley,
Samuel Steven,
Jiani Su
Abstract:
We discuss a novel paradigm in the optical readout of scintillation radiation detectors. In one common configuration, such detectors are homogeneous and the scintillation light is collected and recorded by external photodetectors. It is usually assumed that imaging in such a photon-starved and large-emittance regime is not possible. Here we show that the appropriate optics, matched with highly seg…
▽ More
We discuss a novel paradigm in the optical readout of scintillation radiation detectors. In one common configuration, such detectors are homogeneous and the scintillation light is collected and recorded by external photodetectors. It is usually assumed that imaging in such a photon-starved and large-emittance regime is not possible. Here we show that the appropriate optics, matched with highly segmented photodetector coverage and dedicated reconstruction software, can be used to produce images of the radiation-induced events. In particular, such a 'distributed imaging' system can discriminate between events produced as a single cluster and those resulting from more delocalized energy depositions. This is crucial in discriminating many common backgrounds at MeV energies. With the use of simulation, we demonstrate the performance of a detector augmented with a practical, if preliminary, set of optics. Finally, we remark that this new technique lends itself to be adapted to different detector sizes and briefly discuss the implications for a number of common applications in science and technology.
△ Less
Submitted 27 November, 2017;
originally announced November 2017.
-
Search for nucleon decays with EXO-200
Authors:
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (70 additional authors not shown)
Abstract:
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.
△ Less
Submitted 11 April, 2018; v1 submitted 20 October, 2017;
originally announced October 2017.
-
Characterization of an Ionization Readout Tile for nEXO
Authors:
nEXO Collaboration,
M. Jewell,
A. Schubert,
W. R. Cen,
J. Dalmasson,
R. DeVoe,
L. Fabris,
G. Gratta,
A. Jamil,
G. Li,
A. Odian,
M. Patel,
A. Pocar,
D. Qiu,
Q. Wang,
L. J. Wen,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky
, et al. (120 additional authors not shown)
Abstract:
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale n…
▽ More
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.
△ Less
Submitted 19 January, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
Authors:
nEXO Collaboration,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
M. Côté,
A. Craycraft,
W. Cree,
J. Dalmasson
, et al. (121 additional authors not shown)
Abstract:
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by…
▽ More
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.
△ Less
Submitted 19 October, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Trace radioactive impurities in final construction materials for EXO-200
Authors:
D. S. Leonard,
D. Auty,
T. Didberidze,
R. Gornea,
P. Grinberg,
R. MacLellan,
B. Methven,
A. Piepke,
J. -L. Vuilleumier,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree
, et al. (76 additional authors not shown)
Abstract:
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of…
▽ More
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.
△ Less
Submitted 31 March, 2017;
originally announced March 2017.
-
Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Daughhetee,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
J. Dilling
, et al. (63 additional authors not shown)
Abstract:
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift…
▽ More
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20~V/cm and 615~V/cm using EXO-200 data. At the operating field of 380~V/cm EXO-200 measures a drift velocity of 1.705$_{-0.010}^{+0.014}$~mm/$μ$s and a transverse diffusion coefficient of 55$\pm$4~cm$^2$/s.
△ Less
Submitted 22 March, 2017; v1 submitted 14 September, 2016;
originally announced September 2016.
-
An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout
Authors:
EXO-200 Collaboration,
:,
C. G. Davis,
C. Hall,
J. B. Albert,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze
, et al. (63 additional authors not shown)
Abstract:
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless d…
▽ More
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless double beta decay Q-value from $\left[1.9641\pm 0.0039\right]\%$ to $\left[1.5820\pm 0.0044\right]\%$.
△ Less
Submitted 22 March, 2017; v1 submitted 20 May, 2016;
originally announced May 2016.
-
Cosmogenic Backgrounds to 0νββ in EXO-200
Authors:
EXO-200 Collaboration,
:,
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
J. Dilling,
A. Dolgolenko
, et al. (63 additional authors not shown)
Abstract:
As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste…
▽ More
As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be Φ = 4.07 $\pm$ 0.14 (sys) $\pm$ 0.03 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$, with a vertical intensity of $I_{v}$ = 2.97$^{+0.14}_{-0.13}$ (sys) $\pm$ 0.02 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$ sr$^{-1}$. Simulations of muon-induced backgrounds identified several potential cosmogenic radionuclides, though only 137Xe is a significant background for the 136Xe 0νββ search with EXO-200. Muon-induced neutron backgrounds were measured using γ-rays from neutron capture on the detector materials. This provided a measurement of 137Xe yield, and a test of the accuracy of the neutron production and transport simulations. The independently measured rates of 136Xe neutron capture and of 137Xe decay agree within uncertainties. Geant4 and FLUKA simulations were performed to estimate neutron capture rates, and these estimates agreed to within ~40% or better with measurements. The ability to identify 136Xe(n,γ) events will allow for rejection of 137Xe backgrounds in future 0νββ analyses.
△ Less
Submitted 16 April, 2016; v1 submitted 21 December, 2015;
originally announced December 2015.
-
Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200
Authors:
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
A. Dolgolenko,
M. J. Dolinski,
M. Dunford
, et al. (60 additional authors not shown)
Abstract:
Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction o…
▽ More
Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer drift times. Initially the ions have a mobility of $0.390 \pm 0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time constants associated with the change in mobility during drift of the $^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron lifetime in the LXe.
△ Less
Submitted 3 April, 2017; v1 submitted 31 May, 2015;
originally announced June 2015.
-
Investigation of radioactivity-induced backgrounds in EXO-200
Authors:
J. B. Albert,
D. J. Auty,
P. S. Barbeau,
D. Beck,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
T. Brunner,
A. Burenkov,
G. F. Cao,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
M. Danilov,
S. J. Daugherty,
C. G. Davis,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
T. Didberidze,
A. Dolgolenko,
M. J. Dolinski
, et al. (61 additional authors not shown)
Abstract:
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of…
▽ More
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.
△ Less
Submitted 16 July, 2015; v1 submitted 20 March, 2015;
originally announced March 2015.