-
Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
Authors:
D. Yu. Akimov,
I. S. Aleksandrov,
F. B. Ata Kurbonova,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
Yu. I. Koskin,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy recons…
▽ More
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy reconstruction procedures, and evaluation of the efficiency of electron extraction from the liquid xenon to the gas phase.
△ Less
Submitted 15 May, 2024; v1 submitted 19 March, 2024;
originally announced March 2024.
-
Characterization of the ambient background in the RED-100 experiment location at Kalinin Nuclear Power Plant
Authors:
D. Y. Akimov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
B. O. Lavrov,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper descr…
▽ More
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper describes the external background conditions for the RED-100 experiment at Kalinin Nuclear Power Plant.
△ Less
Submitted 24 November, 2023; v1 submitted 1 November, 2023;
originally announced November 2023.
-
The RED-100 experiment
Authors:
D. Yu. Akimov,
I. S. Alexandrov,
R. R. Alyev,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
E. M. Glagovsky,
Y. V. Gusakov,
A. V. Khromov,
S. M. Kiselev,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is des…
▽ More
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is described. There is no correlation of the radioactive background at the experimental setup site with ON and OFF states of the reactor. The data taking run was carried out at the beginning of the year 2022 and covered both the reactor OFF and ON periods.
△ Less
Submitted 14 November, 2022; v1 submitted 30 September, 2022;
originally announced September 2022.
-
Emergence of super-Poissonian light from indistinguishable single-photon emitters
Authors:
A. Kovalenko,
D. Babjak,
A. Lešundák,
L. Podhora,
L. Lachman,
P. Obšil,
T. Pham,
O. Číp,
R. Filip,
L. Slodička
Abstract:
The optical interference constitutes a paramount resource in modern physics. At the scale of individual atoms and photons, it is a diverse concept that causes different coherent phenomena. We present the experimental characterization of both coherent and statistical properties of light emitted from ensembles of trapped ions increasing with a number of contributing phase-incoherent independent atom…
▽ More
The optical interference constitutes a paramount resource in modern physics. At the scale of individual atoms and photons, it is a diverse concept that causes different coherent phenomena. We present the experimental characterization of both coherent and statistical properties of light emitted from ensembles of trapped ions increasing with a number of contributing phase-incoherent independent atomic particles ranging from a single to up to several hundreds. It conclusively demonstrates how super-Poissonian quantum statistics non-trivially arises purely from the finite number of indistinguishable single-photon emitters in the limit of a single detection mode. The achieved new optical emission regime in which these independent atoms contribute coherently to the super-Poissonian statistics provides a new perspective on the emergence of optical coherence at the atomic scale and constitutes a unique toolbox for its generation and control at the most microscopic level.
△ Less
Submitted 20 September, 2022; v1 submitted 19 September, 2022;
originally announced September 2022.
-
Large and non-linear permeability amplification with polymeric additives in hydrogel membranes
Authors:
Malak Alaa Eddine,
S. Belbekhouche,
Sixtine de Chateauneuf-Randon,
Thomas Salez,
Artem Kovalenko,
Bruno Bresson,
C. Monteux
Abstract:
Hydrogels which are hydrophilic and porous materials have recently emerged as promising systems for filtration applications. In our study, we prepare hydrogel membranes by the photopolymerization of a mixture of poly (ethylene glycol) diacrylate (PEGDA) and large poly(ethylene glycol) (PEG) chains of 300 000 g.mol-1 in the presence of a photoinitiator. We find that this addition of free PEG chains…
▽ More
Hydrogels which are hydrophilic and porous materials have recently emerged as promising systems for filtration applications. In our study, we prepare hydrogel membranes by the photopolymerization of a mixture of poly (ethylene glycol) diacrylate (PEGDA) and large poly(ethylene glycol) (PEG) chains of 300 000 g.mol-1 in the presence of a photoinitiator. We find that this addition of free PEG chains induces a large and non-linear increase of the water permeability. Indeed, by changing the content of PEG chains added, we obtain variations of the hydrogel water permeability over two orders of magnitude. The highest water permeability values are obtained for the membranes when the PEG concentration is equal to its critical overlap concentration C*. Moreover, we find that the flow rate of water through the membranes varies non-linearly with the pressure. We relate this result to the deformability of the membranes as the applied pressure leads to a compression of the pores. This study provides new perspectives for the design of flexible hydrogel membranes with controlled permeability and their application in water treatment and bioseparation.
△ Less
Submitted 2 September, 2022;
originally announced September 2022.
-
Multiple scattering of channeled and non-channeled positively charged particles in bent monocrystalline silicon
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
R. Losito,
A. Masi,
D. Mirarchi,
S. Montesano,
S. Redaelli,
R. Rossi,
G. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
L. Bandiera,
V. Guidi,
A. Mazzolari,
M. Romagnoni,
F. Murtas,
F. Addesa,
G. Cavoto,
F. Iacoangeli
, et al. (17 additional authors not shown)
Abstract:
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in d…
▽ More
We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in detail the influence of angular constraints on the magnitude of the effect. Comparison of the multiple scattering process at different energies indicates a violation of the law of inverse proportionality of the rms angle of channeled particles with energy. By increasing the statistics, we have improved the results of multiple scattering measurements for particles moving, but not channeled, in silicon crystals.
△ Less
Submitted 31 January, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Double-crystal measurements at the CERN SPS
Authors:
W. Scandale,
G. Arduini,
F. Cerutti,
M. D'Andrea,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
D. Mirarchi,
S. Montesano,
A. Natochii,
S. Redaelli,
R. Rossi,
G. I. Smirnov,
L. Burmistrov,
S. Dubos,
V. Puill,
A. Stocchi,
F. Addesa,
F. Murtas,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov
, et al. (13 additional authors not shown)
Abstract:
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam confi…
▽ More
The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam configuration. Timepix detectors and high-sensitivity Beam Loss Monitors were exploited to observe the deflected beams. Linear and angular scans allowed exploring the particle interactions with the two crystals and recording their efficiency. The measured values of the beam trajectories, profiles and of the channeling efficiency agree with the results of a Monte-Carlo simulation.
△ Less
Submitted 26 March, 2021;
originally announced March 2021.
-
Conceptual design of the Spin Physics Detector
Authors:
V. M. Abazov,
V. Abramov,
L. G. Afanasyev,
R. R. Akhunzyanov,
A. V. Akindinov,
N. Akopov,
I. G. Alekseev,
A. M. Aleshko,
V. Yu. Alexakhin,
G. D. Alexeev,
M. Alexeev,
A. Amoroso,
I. V. Anikin,
V. F. Andreev,
V. A. Anosov,
A. B. Arbuzov,
N. I. Azorskiy,
A. A. Baldin,
V. V. Balandina,
E. G. Baldina,
M. Yu. Barabanov,
S. G. Barsov,
V. A. Baskov,
A. N. Beloborodov,
I. N. Belov
, et al. (270 additional authors not shown)
Abstract:
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarize…
▽ More
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarized beams at JINR.
The main objective of the proposed experiment is the comprehensive study of the unpolarized and polarized gluon content of the nucleon. Spin measurements at the Spin Physics Detector at the NICA collider have bright perspectives to make a unique contribution and challenge our understanding of the spin structure of the nucleon. In this document the Conceptual Design of the Spin Physics Detector is presented.
△ Less
Submitted 2 February, 2022; v1 submitted 31 January, 2021;
originally announced February 2021.
-
Experimental demonstration of negative refractionwith 3D locally resonant acoustic metafluids
Authors:
Benoit Tallon,
Artem Kovalenko,
Olivier Poncelet,
Christophe Aristégui,
Olivier Mondain-Monval,
Thomas Brunet
Abstract:
Negative refraction of acoustic waves is demonstrated through underwater experiments conducted at ultrasonic frequencies on a 3D locally resonant acoustic metafluid made of soft porous silicone-rubber micro-beads suspended in a yield-stress fluid. By measuring the refracted angle of the acoustic beam transmitted through this metafluid shaped as a prism, we determine the acoustic index to water acc…
▽ More
Negative refraction of acoustic waves is demonstrated through underwater experiments conducted at ultrasonic frequencies on a 3D locally resonant acoustic metafluid made of soft porous silicone-rubber micro-beads suspended in a yield-stress fluid. By measuring the refracted angle of the acoustic beam transmitted through this metafluid shaped as a prism, we determine the acoustic index to water according to Snell's law. These experimental data are then compared with an excellent agreement to calculations performed in the framework of Multiple Scattering Theory showing that the emergence of negative refraction depends on the volume fraction $Φ$ of the resonant micro-beads. For diluted metafluid ($Φ=3\%$), only positive refraction occurs whereas negative refraction is demonstrated over a broad frequency band with concentrated metafluid ($Φ=17\%$).
△ Less
Submitted 4 January, 2021;
originally announced January 2021.
-
First ground-level laboratory test of the two-phase xenon emission detector RED-100
Authors:
D. Yu. Akimov,
V. A. Belov,
A. I. Bolozdynya,
Yu. V. Efremenko,
A. V. Etenko,
A. V. Galavanov,
D. V. Gouss,
Yu. V. Gusakov,
Dj. Ed. Kdib,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
Yu. A. Melikyan,
V. V. Moramzin,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
Yu. V. Stogov,
A. A. Vasin
Abstract:
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamats…
▽ More
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamatsu R11410-20 PMTs assembled in two planes on top and bottom. The electrode system is equipped with an electron shutter (a patented device) to reduce a "spontaneous" single-electron noise. The detector was tested in a ground-level laboratory. The obtained results demonstrate that detection of coherent elastic scattering of reactor antineutrinos off xenon nuclei at Kalinin nuclear power plant with the RED-100 detector is feasible with a threshold of 4 ionization electrons.
△ Less
Submitted 14 October, 2019;
originally announced October 2019.
-
Enhanced solvation force extrapolation for speeding up molecular dynamics simulations of complex biochemical liquids
Authors:
Igor Omelyan,
Andriy Kovalenko
Abstract:
We propose an enhanced approach to the extrapolation of mean potential forces acting on atoms of solute macromolecules due to their interactions with solvent atoms in complex biochemical liquids. It improves and extends previous extrapolation schemes by including additionally new techniques such as an exponential scaling transformation of coordinate space with weights complemented by a dynamically…
▽ More
We propose an enhanced approach to the extrapolation of mean potential forces acting on atoms of solute macromolecules due to their interactions with solvent atoms in complex biochemical liquids. It improves and extends previous extrapolation schemes by including additionally new techniques such as an exponential scaling transformation of coordinate space with weights complemented by a dynamically adjusted balancing between the least square minimization of force deviations and the norm of expansion coefficients in the approximation. The expensive mean potential forces are treated in terms of the 3D-RISM-KH molecular theory of solvation (three-dimensional reference interaction site model with the Kovalenko-Hirata closure). During the dynamics they are calculated only after every long enough (outer) time interval, i.e., quite rarely to reduce the computational costs. At much shorter (inner) time steps, these forces are extrapolated on the basis of their outer values. The equations of motion are then solved using a multiple time step integration within an optimized isokinetic Nosé-Hoover chain thermostat. The new approach is applied to molecular dynamics simulations of various systems consisting of solvated organic and biomolecules of different complexity. Namely, we consider hydrated alanine dipeptide, asphaltene in toluene solvent, miniprotein 1L2Y and protein G in aqueous solution. It is shown that in all these cases, the enhanced extrapolation provides much better accuracy of the solvation force approximation than the existing approaches. As a result, it can be used with much larger outer time steps, leading to a significant speedup of the simulations.
△ Less
Submitted 10 September, 2019;
originally announced September 2019.
-
Double-crystal setup measurements at the CERN SPS
Authors:
W. Scandale,
F. Cerutti,
L. S. Esposito,
M. Garattini,
S. Gilardoni,
S. Montesano,
R. Rossi,
L. Burmistrov,
S. Dubos,
A. Natochii,
V. Puill,
A. Stocchi,
V. Zhovkovska,
F. Murtas,
F. Addesa,
F. Iacoangeli,
F. Galluccio,
A. D. Kovalenko,
A. M. Taratin,
G. I. Smirnov,
A. S. Denisov,
Yu. A. Gavrikov,
Yu. M. Ivanov,
L. P. Lapina,
L. G. Malyarenko
, et al. (11 additional authors not shown)
Abstract:
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadro…
▽ More
In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadron Collider (LHC) scale. The presented in the text configuration was used for the quantitative characterization of the deflected particle beam by a pair of bent silicon crystals. For the first time in the double-crystal configuration, a particle deflection efficiency by the second crystal of $0.188 \pm 3 \cdot 10^{-5}$ and $0.179 \pm 0.013$ was measured on the accelerator by means of the Timepix detector and Beam Loss Monitor (BLM) respectively. In this setup, a wide range angular scan allowed a possibility to \textit{in situ} investigate different crystal working regimes (channeling, volume reflection, etc.), and to measure a bent crystal torsion.
△ Less
Submitted 6 September, 2019;
originally announced September 2019.
-
COHERENT 2018 at the Spallation Neutron Source
Authors:
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
A. Brown,
A. Burenkov,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
J. Daughhetee,
D. J. Dean,
M. del Valle Coello,
J. A. Detwiler,
M. D'Onofrio,
Y. Efremenko,
S. R. Elliott,
E. Erkela,
A. Etenko
, et al. (54 additional authors not shown)
Abstract:
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present th…
▽ More
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.
△ Less
Submitted 2 April, 2018; v1 submitted 24 March, 2018;
originally announced March 2018.
-
First results on the measurements of the proton beam polarization at internal target at Nuclotron
Authors:
V. P. Ladygin,
Yu. V. Gurchin,
A. Yu. Isupov,
M. Janek,
A. N. Khrenov,
P. K. Kurilkin,
A. N. Livanov,
S. M. Piyadin,
S. G. Reznikov,
Ya. T. Skhomenko,
A. A. Terekhin,
A. V. Tishevsky,
A. V. Averyanov,
S. N. Bazylev,
A. S. Belov,
A. V. Butenko,
E. V. Chernykh,
Yu. N. Filatov,
V. V. Fimushkin,
D. O. Krivenkov,
A. M. Kondratenko,
M. A. Kondratenko,
A. D. Kovalenko,
I. V. Slepnev,
V. M. Slepnev
, et al. (4 additional authors not shown)
Abstract:
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scatteri…
▽ More
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scattering and DSS setup at internal target. The obtained value of the vertical polarization of ~35 % is consistent with the calculations taking into account the current magnetic optics of the Nuclotron injection line.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
New method of 85Kr reduction in a noble gas based low-background detector
Authors:
D. Yu. Akimov,
A. I. Bolozdynya,
A. A. Burenkov,
C. Hall,
A. G. Kovalenko,
V. V. Kuzminov,
G. E. Simakov
Abstract:
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much lar…
▽ More
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much larger than the natural krypton that is already present. After the purification system reduces the total Kr concentration to the same level, the final 85Kr concentration will have been reduced even further by the dilution factor. A test cell for measurement of the activity of various Kr samples has been assembled, and the activity of 25-year-old Krypton has been measured. The measured activity agrees well with the expected activity accounting for the 85Kr abundance of the earth atmosphere in 1990 and the half-life of the isotope. Additional tests with a Kr sample produced in the year 1944 (before the atomic era) have been done in order to demonstrate the sensitivity of the test cell.
△ Less
Submitted 22 November, 2016;
originally announced November 2016.
-
The COHERENT Experiment at the Spallation Neutron Source
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
P. Barton,
B. Becker,
V. Belov,
A. Bolozdynya,
A. Burenkov,
B. Cabrera-Palmer,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
C. Cuesta,
D. Dean,
J. Detwiler,
A. G. Dolgolenko,
Y. Efremenko,
S. R. Elliott,
A. Etenko,
N. Fields,
W. Fox,
A. Galindo-Uribarri,
M. Green
, et al. (42 additional authors not shown)
Abstract:
The COHERENT collaboration's primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils…
▽ More
The COHERENT collaboration's primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the $N^2$ dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.
△ Less
Submitted 3 April, 2016; v1 submitted 29 September, 2015;
originally announced September 2015.
-
Gravitational Redshift Experiment with the Space Radio Telescope RadioAstron
Authors:
D. Litvinov,
N. Bartel,
K. Belousov,
M. Bietenholz,
A. Biriukov,
A. Fionov,
A. Gusev,
V. Kauts,
A. Kovalenko,
V. Kulagin,
N. Poraiko,
V. Rudenko
Abstract:
A unique test of general relativity is possible with the space radio telescope RadioAstron. The ultra-stable on-board hydrogen maser frequency standard and the highly eccentric orbit make RadioAstron an ideal instrument for probing the gravitational redshift effect. Large gravitational potential variation, occurring on the time scale of $\sim$24 hr, causes large variation of the on-board H-maser c…
▽ More
A unique test of general relativity is possible with the space radio telescope RadioAstron. The ultra-stable on-board hydrogen maser frequency standard and the highly eccentric orbit make RadioAstron an ideal instrument for probing the gravitational redshift effect. Large gravitational potential variation, occurring on the time scale of $\sim$24 hr, causes large variation of the on-board H-maser clock rate, which can be detected via comparison with frequency standards installed at various ground radio astronomical observatories. The experiment requires specific on-board hardware operating modes and support from ground radio telescopes capable of tracking the spacecraft continuously and equipped with 8.4 or 15 GHz receivers. Our preliminary estimates show that $\sim$30 hr of the space radio telescope's observational time are required to reach $\sim 2\times10^{-5}$ accuracy in the test, which would constitute a factor of 10 improvement over the currently achieved best result.
△ Less
Submitted 12 March, 2015;
originally announced March 2015.
-
Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
Authors:
D. Yu. Akimov,
V. V. Afanasyev,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
Yu. V. Efremenko,
D. A. Egorov,
A. V. Etenko,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin,
A. M. Konovalov,
A. G. Kovalenko,
A. V. Kuchenkov,
A. V. Kumpan,
Yu. A. Melikyan,
R. I. Nikolaev,
D. G. Rudik,
V. V. Sosnovtsev
, et al. (1 additional authors not shown)
Abstract:
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predicti…
▽ More
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predictions. Decay time of scintillation at 2.82 keV is measured to be 25 +/- 3 ns at the electric field of 3.75 kV/cm.
△ Less
Submitted 8 August, 2014;
originally announced August 2014.
-
Two-phase xenon emission detector with electron multiplier and optical readout by multipixel avalanche Geiger photodiodes
Authors:
D. Yu. Akimov,
A. V. Akindinov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
A. F. Buzulutskov,
M. V. Danilov,
Yu. V. Efremenko,
M. A. Kirsanov,
A. G. Kovalenko,
V. N. Stekhanov
Abstract:
A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was demonstrated.
A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was demonstrated.
△ Less
Submitted 17 April, 2013; v1 submitted 29 March, 2013;
originally announced March 2013.
-
Measurement and simulation of the muon-induced neutron yield in lead
Authors:
L. Reichhart,
A. Lindote,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy
, et al. (14 additional authors not shown)
Abstract:
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well…
▽ More
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well the measured capture times and multiplicities and, within the dynamic range of the instrumentation, the spectrum of energy deposits. By comparing measurements with simulations of neutron capture rates a neutron yield in lead of (5.78^{+0.21}_{-0.28}) x 10^{-3} neutrons/muon/(g/cm^{2}) has been obtained. Absolute agreement between simulation and data is of order 25%. Consequences for deep underground rare event searches are discussed.
△ Less
Submitted 4 November, 2013; v1 submitted 18 February, 2013;
originally announced February 2013.
-
Resistance functions for two unequal spheres in linear flow at low Reynolds number with the Navier slip boundary condition
Authors:
Kengo Ichiki,
Alexander E. Kobryn,
Andriy Kovalenko
Abstract:
Resistance functions for two spherical particles with the Navier slip boundary condition in general linear flows, including rigid translation, rigid rotation, and strain, at low Reynolds number are derived by the method of reflections as well as twin multipole expansions. In the solutions, particle radii and slip lengths can be chosen independently. In the course of calculations, single-sphere pro…
▽ More
Resistance functions for two spherical particles with the Navier slip boundary condition in general linear flows, including rigid translation, rigid rotation, and strain, at low Reynolds number are derived by the method of reflections as well as twin multipole expansions. In the solutions, particle radii and slip lengths can be chosen independently. In the course of calculations, single-sphere problem with the slip boundary condition is solved by Lamb's general solution and the expression of multipole expansions, and Faxén's laws of force, torque, and stresslet for slip particle are also derived. The solutions of two-body problem are confirmed to recover the existing results in the no-slip limit and for the case of equal scaled slip lengths.
△ Less
Submitted 3 February, 2013;
originally announced February 2013.
-
Perspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector
Authors:
RED Collaboration,
D. Yu. Akimov,
I. S. Alexandrov,
V. I. Aleshin,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
A. S. Chepurnov,
M. V. Danilov,
A. V. Derbin,
V. V. Dmitrenko,
A. G. Dolgolenko,
D. A. Egorov,
Yu. V. Efremenko,
A. V. Etenko,
M. B. Gromov,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kantserov,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin
, et al. (21 additional authors not shown)
Abstract:
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites…
▽ More
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites have advantages as well as limitations. However the experiment looks feasible at either location. Preliminary design of the detector and supporting R&D program are discussed.
△ Less
Submitted 9 December, 2012;
originally announced December 2012.
-
Is photoisomerization of stilbene in solution directly promoted by solvent collisions?
Authors:
S. A. Kovalenko,
A. L. Dobryakov,
N. P. Ernsting
Abstract:
Gas phase thermal isomerization rates of trans-stilbene at 300 K obey the Arrhenius law. In solution the rates increase ten-fold and depend only very weakly on excitation wavelength or intramolecular temperature. Both observations are difficult to reconcile within RRKM theory. Previously discussed mechanisms, like restricted IVR, nonadiabaticity, solvent-dependent barriers, or excitation-induced c…
▽ More
Gas phase thermal isomerization rates of trans-stilbene at 300 K obey the Arrhenius law. In solution the rates increase ten-fold and depend only very weakly on excitation wavelength or intramolecular temperature. Both observations are difficult to reconcile within RRKM theory. Previously discussed mechanisms, like restricted IVR, nonadiabaticity, solvent-dependent barriers, or excitation-induced cooling, may explain the increase of the rates in solution but not their dependence on the excitation wavelength. The latter suggests that solvent collisions can directly promote the isomerization.
△ Less
Submitted 5 December, 2012; v1 submitted 10 April, 2012;
originally announced April 2012.
-
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Authors:
V. N. Solovov,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (11 additional authors not shown)
Abstract:
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the…
▽ More
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
△ Less
Submitted 26 September, 2012; v1 submitted 7 December, 2011;
originally announced December 2011.
-
Performance data from the ZEPLIN-III second science run
Authors:
P. Majewski,
V. N. Solovov,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (10 additional authors not shown)
Abstract:
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the…
▽ More
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the instrument performance with emphasis on the position and energy reconstruction algorithm and summarise the final science results.
△ Less
Submitted 30 November, 2011;
originally announced December 2011.
-
Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
Authors:
E. Santos,
B. Edwards,
V. Chepel,
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
L. DeViveiros,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these…
▽ More
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of $\sim$3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
The UA9 experimental layout
Authors:
W. Scandale,
G. Arduini,
R. Assmann,
C. Bracco,
F. Cerutti,
J. Christiansen,
S. Gilardoni,
E. Laface,
R. Losito,
A. Masi,
E. Metral,
D. Mirarchi,
S. Montesano,
V. Previtali,
S. Redaelli,
G. Valentino,
P. Schoofs,
G. Smirnov,
L. Tlustos,
E. Bagli,
S. Baricordi,
P. Dalpiaz,
V. Guidi,
A. Mazzolari,
D. Vincenzi
, et al. (36 additional authors not shown)
Abstract:
The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode.
Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam.
Scintill…
▽ More
The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode.
Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam.
Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the im**ing beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.
△ Less
Submitted 29 June, 2011;
originally announced June 2011.
-
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Authors:
F. Neves,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. Preece
, et al. (12 additional authors not shown)
Abstract:
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d…
▽ More
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.
△ Less
Submitted 4 June, 2011;
originally announced June 2011.
-
Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
Authors:
M. Horn,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
C. Ghag,
A. Hollingsworth,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (11 additional authors not shown)
Abstract:
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r…
▽ More
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is found, together with a rising ionisation yield; both are in good agreement with the latest independent measurements. The analysis method is applied to both the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
△ Less
Submitted 17 October, 2011; v1 submitted 3 June, 2011;
originally announced June 2011.
-
Radioactivity Backgrounds in ZEPLIN-III
Authors:
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel. A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy. F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (10 additional authors not shown)
Abstract:
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level…
▽ More
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05$\pm$0.5 nuclear recoils with energy 5-50 keV per year, which translates to an expectation of 0.4 events in a 1-year dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from $β$ activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter $γ$-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of $\sim 1 \times 10^{-8}$ pb$\cdot$year to the scalar WIMP-nucleon elastic cross-section, as originally conceived.
△ Less
Submitted 12 August, 2011; v1 submitted 18 April, 2011;
originally announced April 2011.
-
Characterization of large area APDs for the EXO-200 detector
Authors:
R. Neilson,
F. LePort,
A. Pocar,
K. Kumar,
A. Odian,
C. Y. Prescott,
V. Tenev,
N. Ackerman,
D. Akimov,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
R. Conley,
S. Cook,
R. deVoe,
M. J. Dolinski,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger,
B. Flatt,
R. Gornea,
G. Gratta,
M. Green,
C. Hall
, et al. (27 additional authors not shown)
Abstract:
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more tha…
▽ More
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
△ Less
Submitted 13 June, 2009;
originally announced June 2009.
-
Calibration of Photomultiplier Arrays
Authors:
F. Neves,
V. Chepel,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
B. Edwards,
C. Ghag,
M. Horn,
A. J. Hughes,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (9 additional authors not shown)
Abstract:
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields,…
▽ More
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields, etc) are exactly matched between calibration and science acquisitions. This is of particular importance in low background experiments such as ZEPLIN-III, where methods involving the use of external light sources for calibration are severely constrained.
△ Less
Submitted 15 May, 2009;
originally announced May 2009.
-
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Authors:
D. S. Leonard,
P. Grinberg,
P. Weber,
E. Baussan,
Z. Djurcic,
G. Keefer,
A. Piepke,
A. Pocar,
J. -L. Vuilleumier,
J. -M. Vuilleumier,
D. Akimov,
A. Bellerive,
M. Bowcock,
M. Breidenbach,
A. Burenkov,
R. Conley,
W. Craddock,
M. Danilov,
R. DeVoe,
M. Dixit,
A. Dolgolenko,
I. Ekchtout,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (32 additional authors not shown)
Abstract:
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma…
▽ More
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.
△ Less
Submitted 4 August, 2008; v1 submitted 28 September, 2007;
originally announced September 2007.
-
Development of Nuclotron Magnet Power Supply Control System
Authors:
B. Vasilishin,
V. Andreev,
V. Gorchenko,
A. Kirichenko,
A. Kovalenko,
I. Kulikov,
B. Omelchenko,
V. Karpinsky,
S. Romanov,
B. Sveshnikov,
A. Tharenkov,
V. Volkov
Abstract:
The magnetic field control subsystem of the Nuclotron - a superferric ion synchrotron - is described. The bending (BM), focusing (QF) and defocusing (QD) magnets are powered by three supplies. The BMs are driven by the supply of a 6.3 kA nominal current. The QFs and QDs are connected in series and powered by the 6 kA supply. An additional supply of 200 A for the QFs is used to keep the reqired r…
▽ More
The magnetic field control subsystem of the Nuclotron - a superferric ion synchrotron - is described. The bending (BM), focusing (QF) and defocusing (QD) magnets are powered by three supplies. The BMs are driven by the supply of a 6.3 kA nominal current. The QFs and QDs are connected in series and powered by the 6 kA supply. An additional supply of 200 A for the QFs is used to keep the reqired ratio I(QF)/I(QD). The BM magnetic field shape is set by a pulse function generator which produceds a reference burst (Bo-train) with a 0.1 Gs resolution. A real B-train of the bending magnet field with the same (0.1 Gs) resolution is used for feedback loop and as reference function for QD and QF supplies. The QD and QF trains are utilized for feedback loop in the QD and QF supplies. The control of slow extraction system suppllies is described as well.
△ Less
Submitted 22 October, 2001;
originally announced October 2001.