-
Ronchigram Simulation and Training through Ronchigram.com
Authors:
Suk Hyun Sung,
Noah Schnitzer,
William Millsaps,
Lena F. Kourkoutis,
Robert Hovden
Abstract:
This article introduces a training simulator for electron beam alignment using Ronchigrams. The interactive web application, www.ronchigram.com, is an advanced educational tool aimed at making scanning transmission electron microscopy (STEM) more accessible and open. For experienced microscopists, the tool offers on-hand quantification of simulated Ronchigrams and their resolution limits.
This article introduces a training simulator for electron beam alignment using Ronchigrams. The interactive web application, www.ronchigram.com, is an advanced educational tool aimed at making scanning transmission electron microscopy (STEM) more accessible and open. For experienced microscopists, the tool offers on-hand quantification of simulated Ronchigrams and their resolution limits.
△ Less
Submitted 22 September, 2022;
originally announced September 2022.
-
A kiloelectron-volt ultrafast electron micro-diffraction apparatus using low emittance semiconductor photocathodes
Authors:
W. H. Li,
C. J. R. Duncan,
M. B. Andorf,
A. C. Bartnik,
E. Bianco,
L. Cultrera,
A. Galdi,
M. Gordon,
M. Kaemingk,
C. A. Pennington,
L. F. Kourkoutis,
I. V. Bazarov,
J. M. Maxson
Abstract:
We report the design and performance of a time-resolved electron diffraction apparatus capable of producing intense bunches with simultaneously single digit micron probe size, long coherence length, and $200$ fs rms time resolution. We measure the 5d (peak) beam brightness at the sample location in micro-diffraction mode to be $7 \times 10^{13} \ \mathrm{A}/\text{m}^2\text{-rad}^2$. To generate hi…
▽ More
We report the design and performance of a time-resolved electron diffraction apparatus capable of producing intense bunches with simultaneously single digit micron probe size, long coherence length, and $200$ fs rms time resolution. We measure the 5d (peak) beam brightness at the sample location in micro-diffraction mode to be $7 \times 10^{13} \ \mathrm{A}/\text{m}^2\text{-rad}^2$. To generate high brightness electron bunches, the system employs high efficiency, low emittance semiconductor photocathodes driven with a wavelength near the photoemission threshold at a repetition rate up to 250 kHz. We characterize spatial, temporal, and reciprocal space resolution of the apparatus. We perform proof-of-principle measurements of ultrafast heating in single crystal Au samples and compare experimental results with simulations that account for the effects of multiple-scattering.
△ Less
Submitted 2 February, 2022; v1 submitted 15 November, 2021;
originally announced November 2021.
-
Atomic-resolution elemental map** at cryogenic temperatures enabled by direct electron detection
Authors:
Berit H. Goodge,
David J. Baek,
Lena F. Kourkoutis
Abstract:
Spectroscopic map** by scanning transmission electron microscopy coupled with electron energy loss spectroscopy (STEM-EELS) is a powerful technique for determining the structure and chemistry of a wide range of materials and interfaces. The extension of this technique to cryogenic temperatures opens the door to new experiments across many fields including materials physics, energy storage and co…
▽ More
Spectroscopic map** by scanning transmission electron microscopy coupled with electron energy loss spectroscopy (STEM-EELS) is a powerful technique for determining the structure and chemistry of a wide range of materials and interfaces. The extension of this technique to cryogenic temperatures opens the door to new experiments across many fields including materials physics, energy storage and conversion, and biology. Such experiments, however, often face signal limitations due to sample sensitivity or the need for rapid data acquisition under less stable cryogenic conditions. Compared to traditional indirect detection systems such as charge coupled devices (CCDs), direct electron detectors (DEDs) offer improved detective quantum efficiencies, narrower point spread functions, and superior signal-to-noise ratios. Here, we compare the performance of a Gatan K2 Summit DED to an UltraScan 1000 CCD for use in signal-limited atomic-resolution STEM-EELS experiments. Due to its improved point spread function, the DED's energy resolution remains comparable to that of the CCD at a 5 times lower dispersion, providing simultaneous access to a much broader total energy range without sacrificing spectral resolution. More importantly, the benefits of direct detection enable a variety of low-signal experiments, including atomic-resolution map** of minor and high energy edges such as the La-M$_{2,3}$ edge at 1123 eV and the Bi-M$_{4,5}$ edge at 2580 eV. For rapid acquisitions at 400 spectra per second, elemental maps recorded with the DED show an up to 40 percent increase in atomic lattice fringe contrast compared to those acquired with the CCD. Taking advantage of these performance improvements and the fast readout of the K2 DED, we use direct detection STEM-EELS to demonstrate atomic-resolution elemental map** at cryogenic temperatures.
△ Less
Submitted 19 July, 2020;
originally announced July 2020.
-
Atomic-resolution cryo-STEM across continuously variable temperature
Authors:
Berit H. Goodge,
Elisabeth Bianco,
Henny W. Zandbergen Lena F. Kourkoutis
Abstract:
Atomic-resolution cryogenic scanning transmission electron microscopy (cryo-STEM) has provided a path to probing the microscopic nature of select low-temperature phases in quantum materials. Expanding cryo-STEM techniques to broadly tunable temperatures will give access to the rich temperature-dependent phase diagrams of these materials. With existing cryo-holders, however, variations in sample te…
▽ More
Atomic-resolution cryogenic scanning transmission electron microscopy (cryo-STEM) has provided a path to probing the microscopic nature of select low-temperature phases in quantum materials. Expanding cryo-STEM techniques to broadly tunable temperatures will give access to the rich temperature-dependent phase diagrams of these materials. With existing cryo-holders, however, variations in sample temperature significantly disrupt the thermal equilibrium of the system, resulting in large-scale sample drift. The ability to tune temperature without negatively impacting the overall instrument stability is crucial, particularly for high-resolution experiments. Here, we test a new side-entry continuously variable temperature dual-tilt cryo-holder which integrates liquid nitrogen cooling with a 6-pin MEMS sample heater to overcome some of these experimental challenges. We measure consistently low drift rates of 0.3-0.4 Angstrom/s and demonstrate atomic-resolution cryo-STEM imaging across a continuously variable temperature range from ~100 K to well above room temperature. We conduct additional drift stability measurements across several commercial sample stages and discuss implications for further developments of ultra-stable, flexible cryo-stages.
△ Less
Submitted 30 January, 2020;
originally announced January 2020.
-
Mesophase Formation Stabilizes High-Purity Magic-Sized Clusters
Authors:
Douglas R. Nevers,
Curtis B. Williamson,
Benjamin H. Savitzky,
Ido Hadar,
Uri Banin,
Lena F. Kourkoutis,
Tobias Hanrath,
Richard D. Robinson
Abstract:
Magic-sized clusters (MSCs) are renowned for their identical size and closed-shell stability that inhibit conventional nanoparticle (NP) growth processes. Though MSCs have been of increasing interest, understanding the reaction pathways toward their nucleation and stabilization is an outstanding issue. In this work, we demonstrate that high concentration synthesis (1000 mM) promotes a well-defined…
▽ More
Magic-sized clusters (MSCs) are renowned for their identical size and closed-shell stability that inhibit conventional nanoparticle (NP) growth processes. Though MSCs have been of increasing interest, understanding the reaction pathways toward their nucleation and stabilization is an outstanding issue. In this work, we demonstrate that high concentration synthesis (1000 mM) promotes a well-defined reaction pathway to form high-purity MSCs (greater than 99.9 percent). The MSCs are resistant to typical growth and dissolution processes. Based on insights from in-situ X-ray scattering analysis, we attribute this stability to the accompanying production of a large, hexagonal organic-inorganic mesophase (greater than 100 nm grain size) that arrests growth of the MSCs and prevents NP growth. At intermediate concentrations (500 mM), the MSC mesophase forms, but is unstable, resulting in NP growth at the expense of the assemblies. These results provide an alternate explanation for the high stability of MSCs. Whereas the conventional mantra has been that the stability of MSCs derives from the precise arrangement of the inorganic structures (i.e., closed-shell atomic packing), we demonstrate that anisotropic clusters can also be stabilized by self-forming fibrous mesophase assemblies. At lower concentration (less than 200 mM or greater than 16 acid-to-metal), MSCs are further destabilized and NPs formation dominates that of MSCs. Overall, the high concentration approach intensifies and showcases inherent concentration-dependent surfactant phase behavior that is not accessible in conventional (i.e., dilute) conditions. This work provides not only a robust method to synthesize, stabilize, and study identical MSC products, but also uncovers an underappreciated stabilizing interaction between surfactants and clusters.
△ Less
Submitted 26 June, 2019;
originally announced June 2019.
-
Image registration of low signal-to-noise cryo-STEM data
Authors:
Benjamin H. Savitzky,
Ismail El Baggari,
Colin Clement,
Emily Waite,
John P. Sheckelton,
Christopher Pasco,
Alemayehu S. Admasu,
Jaewook Kim,
Sang-Wook Cheong,
Tyrel M. McQueen,
Robert Hovden,
Lena F. Kourkoutis
Abstract:
Combining multiple fast image acquisitions to mitigate scan noise and drift artifacts has proven essential for picometer precision, quantitative analysis of atomic resolution scanning transmission electron microscopy (STEM) data. For very low signal-to-noise ratio (SNR) image stacks - frequently required for undistorted imaging at liquid nitrogen temperatures - image registration is particularly d…
▽ More
Combining multiple fast image acquisitions to mitigate scan noise and drift artifacts has proven essential for picometer precision, quantitative analysis of atomic resolution scanning transmission electron microscopy (STEM) data. For very low signal-to-noise ratio (SNR) image stacks - frequently required for undistorted imaging at liquid nitrogen temperatures - image registration is particularly delicate, and standard approaches may either fail, or produce subtly specious reconstructed lattice images. We present an approach which effectively registers and averages image stacks which are challenging due to their low-SNR and propensity for unit cell misalignments. Registering all possible image pairs in a multi-image stack leads to significant information surplus. In combination with a simple physical picture of stage drift, this enables identification of incorrect image registrations, and determination of the optimal image shifts from the complete set of relative shifts. We demonstrate the effectiveness of our approach on experimental, cryogenic STEM datasets, highlighting subtle artifacts endemic to low-SNR lattice images and how they can be avoided. High-SNR average images with information transfer out to 0.72 A are achieved at 300 kV and with the sample cooled to near liquid nitrogen temperature.
△ Less
Submitted 23 October, 2017;
originally announced October 2017.
-
Nanomaterial datasets to advance tomography in scanning transmission electron microscopy
Authors:
Barnaby D. A. Levin,
Elliot Padgett,
Chien-Chun Chen,
M. C. Scott,
Rui Xu,
Wolfgang Theis,
Yi Jiang,
Yongsoo Yang,
Colin Ophus,
Haitao Zhang,
Don-Hyung Ha,
Deli Wang,
Yingchao Yu,
Hector D. Abruna,
Richard D. Robinson,
Peter Ercius,
Lena F. Kourkoutis,
Jianwei Miao,
David A. Muller,
Robert Hovden
Abstract:
Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for develo** and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in ord…
▽ More
Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for develo** and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co2P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180° tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of post-processing and visualization techniques. Researchers interested in creating novel data processing and reconstruction algorithms will now have access to state of the art experimental test data.
△ Less
Submitted 9 June, 2016;
originally announced June 2016.