-
The helion charge radius from laser spectroscopy of muonic helium-3 ions
Authors:
The CREMA Collaboration,
Karsten Schuhmann,
Luis M. P. Fernandes,
François Nez,
Marwan Abdou Ahmed,
Fernando D. Amaro,
Pedro Amaro,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Marc Diepold,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth
, et al. (15 additional authors not shown)
Abstract:
Hydrogen-like light muonic ions, in which one negative muon replaces all the electrons, are extremely sensitive probes of nuclear structure, because the large muon mass increases tremendously the wave function overlap with the nucleus. Using pulsed laser spectroscopy we have measured three 2S-2P transitions in the muonic helium-3 ion ($μ^3$He$^+$), an ion formed by a negative muon and bare helium-…
▽ More
Hydrogen-like light muonic ions, in which one negative muon replaces all the electrons, are extremely sensitive probes of nuclear structure, because the large muon mass increases tremendously the wave function overlap with the nucleus. Using pulsed laser spectroscopy we have measured three 2S-2P transitions in the muonic helium-3 ion ($μ^3$He$^+$), an ion formed by a negative muon and bare helium-3 nucleus. This allowed us to extract the Lamb shift $E(2P_{1/2}-2S_{1/2})= 1258.598(48)^{\rm exp}(3)^{\rm theo}$ meV, the 2P fine structure splitting $E_{\rm FS}^{\rm exp} = 144.958(114)$ meV, and the 2S-hyperfine splitting (HFS) $E_{\rm HFS}^{\rm exp} = -166.495(104)^{\rm exp}(3)^{\rm theo}$ meV in $μ^3$He$^+$. Comparing these measurements to theory we determine the rms charge radius of the helion ($^3$He nucleus) to be $r_h$ = 1.97007(94) fm. This radius represents a benchmark for few nucleon theories and opens the way for precision tests in $^3$He atoms and $^3$He-ions. This radius is in good agreement with the value from elastic electron scattering, but a factor 15 more accurate. Combining our Lamb shift measurement with our earlier one in $μ^4$He$^+$ we obtain $r_h^2-r_α^2 = 1.0636(6)^{\rm exp}(30)^{\rm theo}$ fm$^2$ to be compared to results from the isotope shift measurements in regular He atoms, which are however affected by long-standing tensions. By comparing $E_{\rm HFS}^{\rm exp}$ with theory we also obtain the two-photon-exchange contribution (including higher orders) which is another important benchmark for ab-initio few-nucleon theories aiming at understanding the magnetic and current structure of light nuclei.
△ Less
Submitted 25 June, 2023; v1 submitted 19 May, 2023;
originally announced May 2023.
-
Diffusion of muonic hydrogen in hydrogen gas and the measurement of the 1$s$ hyperfine splitting of muonic hydrogen
Authors:
J. Nuber,
A. Adamczak,
M. Abdou Ahmed,
L. Affolter,
F. D. Amaro,
P. Amaro,
P. Carvalho,
Y. -H. Chang,
T. -L. Chen,
W. -L. Chen,
L. M. P. Fernandes,
M. Ferro,
D. Goeldi,
T. Graf,
M. Guerra,
T. W. Hänsch,
C. A. O. Henriques,
M. Hildebrandt,
P. Indelicato,
O. Kara,
K. Kirch,
A. Knecht,
F. Kottmann,
Y. -W. Liu,
J. Machado
, et al. (24 additional authors not shown)
Abstract:
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The…
▽ More
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after this cycle modifies the $μ$p atom diffusion in the hydrogen gas and the arrival time of the $μ$p atoms at the target walls. This laser-induced modification of the arrival times is used to expose the atomic transition. In this paper we present the simulation of the $μ$p diffusion in the H$_2$ gas which is at the core of the experimental scheme. These simulations have been implemented with the Geant4 framework by introducing various low-energy processes including the motion of the H$_2$ molecules, i.e. the effects related with the hydrogen target temperature. The simulations have been used to optimize the hydrogen target parameters (pressure, temperatures and thickness) and to estimate signal and background rates. These rates allow to estimate the maximum time needed to find the resonance and the statistical accuracy of the spectroscopy experiment.
△ Less
Submitted 24 May, 2023; v1 submitted 15 November, 2022;
originally announced November 2022.
-
Laser excitation of the 1s-hyperfine transition in muonic hydrogen
Authors:
P. Amaro,
A. Adamczak,
M. Abdou Ahmed,
L. Affolter,
F. D. Amaro,
P. Carvalho,
T. -L. Chen,
L. M. P. Fernandes,
M. Ferro,
D. Goeldi,
T. Graf,
M. Guerra,
T. W. Hänsch,
C. A. O. Henriques,
Y. -C. Huang,
P. Indelicato,
O. Kara,
K. Kirch,
A. Knecht,
F. Kottmann,
Y. -W. Liu,
J. Machado,
M. Marszalek,
R. D. P. Mano,
C. M. B. Monteiro
, et al. (21 additional authors not shown)
Abstract:
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $μ$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine…
▽ More
The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $μ$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine state, {then} is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after the collisional deexcitation is used as a signature of a successful laser transition between hyperfine states. In this paper, we calculate the combined probability that a $μ$p atom initially in the singlet hyperfine state undergoes a laser excitation to the triplet state followed by a collisional-induced deexcitation back to the singlet state. This combined probability has been computed using the optical Bloch equations including the inelastic and elastic collisions. Omitting the decoherence effects caused by {the laser bandwidth and }collisions would overestimate the transition probability by more than a factor of two in the experimental conditions. Moreover, we also account for Doppler effects and provide the matrix element, the saturation fluence, the elastic and inelastic collision rates for the singlet and triplet states, and the resonance linewidth. This calculation thus quantifies one of the key unknowns of the HFS experiment, leading to a precise definition of the requirements for the laser system and to an optimization of the hydrogen gas target where $μ$p is formed and the laser spectroscopy will occur.
△ Less
Submitted 7 June, 2022; v1 submitted 30 November, 2021;
originally announced December 2021.
-
The next generation of laser spectroscopy experiments using light muonic atoms
Authors:
S. Schmidt,
M. Willig,
J. Haack,
R. Horn,
A. Adamczak,
M. Abdou Ahmed,
F. D. Amaro,
P. Amaro,
F. Biraben,
P. Carvalho,
T. -L. Chen,
L. M. P. Fernandes,
T. Graf,
M. Guerra,
T. W. Hänsch,
M. Hildebrandt,
Y. -C. Huang,
P. Indelicato,
L. Julien,
K. Kirch,
A. Knecht,
F. Kottmann,
J. J. Krauth,
Y. -W. Liu,
J. Machado
, et al. (19 additional authors not shown)
Abstract:
Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent resu…
▽ More
Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent results of nuclear charge radii extracted from muonic hydrogen and helium spectroscopy and present experiment proposals to access light muonic atoms with $Z \geq 3$. In addition, our approaches towards a precise measurement of the Zemach radii in muonic hydrogen ($μ$p) and helium ($μ$$^{3}$He$^{+}$) are discussed. These results will provide new tests of bound-state quantum-electrodynamics in hydrogen-like systems and can be used as benchmarks for nuclear structure theories.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
The proton radius puzzle
Authors:
J. J. Krauth,
K. Schuhmann,
M. Abdou Ahmed,
F. D. Amaro,
P. Amaro,
F. Biraben,
J. M. R. Cardoso,
M. L. Carvalho,
D. S. Covita,
A. Dax,
S. Dhawan,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. Giesen,
A. L. Gouvea,
J. Götzfried,
T. Graf,
M. Guerra,
J. Haack,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien
, et al. (27 additional authors not shown)
Abstract:
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muon…
▽ More
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.
△ Less
Submitted 19 August, 2017; v1 submitted 2 June, 2017;
originally announced June 2017.
-
Theory of the n=2 levels in muonic helium-3 ions
Authors:
Beatrice Franke,
Julian J. Krauth,
Aldo Antognini,
Marc Diepold,
Franz Kottmann,
Randolf Pohl
Abstract:
The present knowledge of Lamb shift, fine-, and hyperfine structure of the 2S and 2P states in muonic helium-3 ions is reviewed in anticipation of the results of a first measurement of several $\mathrm{2S\rightarrow2P}$ transition frequencies in the muonic helium-3 ion, $\mathrm{μ^3He^+}$. This ion is the bound state of a single negative muon $μ^-$ and a bare helium-3 nucleus (helion),…
▽ More
The present knowledge of Lamb shift, fine-, and hyperfine structure of the 2S and 2P states in muonic helium-3 ions is reviewed in anticipation of the results of a first measurement of several $\mathrm{2S\rightarrow2P}$ transition frequencies in the muonic helium-3 ion, $\mathrm{μ^3He^+}$. This ion is the bound state of a single negative muon $μ^-$ and a bare helium-3 nucleus (helion), $\mathrm{^3He^{++}}$.
A term-by-term comparison of all available sources, including new, updated, and so far unpublished calculations, reveals reliable values and uncertainties of the QED and nuclear structure-dependent contributions to the Lamb shift and the hyperfine splitting. These values are essential for the determination of the helion rms charge radius and the nuclear structure effects to the hyperfine splitting in $\mathrm{μ^3He^+}$. With this review we continue our series of theory summaries in light muonic atoms; see Antognini et al., Ann. Phys. 331, 127 (2013), Krauth et al., Ann.Phys. 366, 168 (2016), and Diepold et al., ArXiv 1606.05231 (2016).
△ Less
Submitted 19 December, 2017; v1 submitted 30 April, 2017;
originally announced May 2017.
-
Laser Spectroscopy of Muonic Atoms and Ions
Authors:
Randolf Pohl,
François Nez,
Luis M. P. Fernandes,
Marwan Abdou Ahmed,
Fernando D. Amaro,
Pedro Amaro,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Marc Diepold,
Beatrice Franke,
Sandrine Galtier,
Adolf Giesen,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Paul Knowles
, et al. (22 additional authors not shown)
Abstract:
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of…
▽ More
Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of the proton and deuteron radii are 10 and 3 times more accurate than the respective CODATA values, but 7 standard deviations smaller. Data on muonic helium-3 and -4 ions is being analyzed and will give new insights. In future, the (magnetic) Zemach radii of the proton and the helium-3 nuclei will be determined from laser spectroscopy of the 1S hyperfine splittings, and the Lamb shifts of muonic Li, Be and B can be used to improve the respective charge radii.
△ Less
Submitted 12 September, 2016;
originally announced September 2016.
-
Deuteron charge radius and Rydberg constant from spectroscopy data in atomic deuterium
Authors:
Randolf Pohl,
François Nez,
Thomas Udem,
Aldo Antognini,
Axel Beyer,
Hélène Fleurbaey,
Alexey Grinin,
Theodor W. Hänsch,
Lucile Julien,
Franz Kottmann,
Julian J. Krauth,
Lothar Maisenbacher,
Arthur Matveev,
François Biraben
Abstract:
We give a pedagogical description of the method to extract the charge radii and Rydberg constant from laser spectroscopy in regular hydrogen (H) and deuterium (D) atoms, that is part of the CODATA least-squares adjustment (LSA) of the fundamental physical constants. We give a deuteron charge radius Rd from D spectroscopy alone of 2.1415(45) fm. This value is independent of the measurements that le…
▽ More
We give a pedagogical description of the method to extract the charge radii and Rydberg constant from laser spectroscopy in regular hydrogen (H) and deuterium (D) atoms, that is part of the CODATA least-squares adjustment (LSA) of the fundamental physical constants. We give a deuteron charge radius Rd from D spectroscopy alone of 2.1415(45) fm. This value is independent of the measurements that lead to the proton charge radius, and five times more accurate than the value found in the CODATA Adjustment 10. The improvement is due to the use of a value for the 1S->2S transition in atomic deuterium which can be inferred from published data or found in a PhD thesis.
△ Less
Submitted 23 November, 2016; v1 submitted 11 July, 2016;
originally announced July 2016.
-
Theory of the Lamb shift and Fine Structure in muonic $\mathrm{^4He}$ ions and the muonic $\mathrm{^3He-^4He}$ Isotope Shift
Authors:
Marc Diepold,
Beatrice Franke,
Julian J. Krauth,
Aldo Antognini,
Franz Kottmann,
Randolf Pohl
Abstract:
We provide an up to date summary of the theory contributions to the 2S-2P Lamb shift and the fine structure of the 2P state in the muonic helium ion $(\mathrm{μ^4He})^+$. This summary serves as the basis for the extraction of the alpha particle charge radius from the muonic helium Lamb shift measurements at the Paul Scherrer Institute, Switzerland. Individual theory contributions needed for a char…
▽ More
We provide an up to date summary of the theory contributions to the 2S-2P Lamb shift and the fine structure of the 2P state in the muonic helium ion $(\mathrm{μ^4He})^+$. This summary serves as the basis for the extraction of the alpha particle charge radius from the muonic helium Lamb shift measurements at the Paul Scherrer Institute, Switzerland. Individual theory contributions needed for a charge radius extraction are compared and compiled into a consistent summary. The influence of the alpha particle charge distribution on the elastic two-photon exchange is studied to take into account possible model-dependencies of the energy levels on the electric form factor of the nucleus. We also discuss the theory uncertainty which enters the extraction of the $\mathrm{^3He-^4He}$ isotope shift from the muonic measurements. The theory uncertainty of the extraction is much smaller than a present discrepancy between previous isotope shift measurements. This work completes our series of $n=2$ theory compilations in light muonic atoms which we have performed already for muonic hydrogen, deuterium, and helium-3 ions.
△ Less
Submitted 6 October, 2018; v1 submitted 16 June, 2016;
originally announced June 2016.
-
Thin-disk laser pump schemes for large number of passes and moderate pump source quality
Authors:
K. Schuhmann,
T. W. Hänsch,
K. Kirch,
A. Knecht,
F. Kottmann,
F. Nez,
R. Pohl,
D. Taqqu,
A. Antognini
Abstract:
Novel thin-disk laser pump layouts are proposed yielding an increased number of passes for a given pump module size and pump source quality. These novel layouts result from a general scheme which bases on merging two simpler pump optics arrangements. Some peculiar examples can be realized by adapting standard commercially available pump optics simply by intro ducing an additional mirror-pair. More…
▽ More
Novel thin-disk laser pump layouts are proposed yielding an increased number of passes for a given pump module size and pump source quality. These novel layouts result from a general scheme which bases on merging two simpler pump optics arrangements. Some peculiar examples can be realized by adapting standard commercially available pump optics simply by intro ducing an additional mirror-pair. More pump passes yield better efficiency, opening the way for usage of active materials with low absorption. In a standard multi-pass pump design, scaling of the number of beam passes brings ab out an increase of the overall size of the optical arrangement or an increase of the pump source quality requirements. Such increases are minimized in our scheme, making them eligible for industrial applications
△ Less
Submitted 25 September, 2015;
originally announced September 2015.
-
Thin-disk laser multi-pass amplifier
Authors:
K. Schuhmann,
M. A. Ahmed,
T. Graf,
T. W. Hänsch,
K. Kirch,
F. Kottmann,
R. Pohl,
D. Taqqu,
A. Voß,
B. Weichelt,
A. Antognini
Abstract:
In the context of the Lamb shift measurement in muonic helium we developed a thin-disk laser composed of a Q-switched oscillator and a multi-pass amplifier delivering pulses of 150 mJ at a pulse duration of 100 ns. Its peculiar requirements are stochastic trigger and short delay time (< 500 ns) between trigger and optical output. The concept of the thin-disk laser allows for energy and power scali…
▽ More
In the context of the Lamb shift measurement in muonic helium we developed a thin-disk laser composed of a Q-switched oscillator and a multi-pass amplifier delivering pulses of 150 mJ at a pulse duration of 100 ns. Its peculiar requirements are stochastic trigger and short delay time (< 500 ns) between trigger and optical output. The concept of the thin-disk laser allows for energy and power scaling with high efficiency. However the single pass gain is small (about 1.2). Hence a multi-pass scheme with precise mode matching for large beam waists (w = 2 mm) is required. Instead of using the standard 4f design, we have developed a multi-pass amplifier with a beam propagation insensitive to thermal lens effects and misalignments. The beam propagation is equivalent to multiple roundtrips in an optically stable resonator. To support the propagation we used an array of 2 x 8 individually adjustable plane mirrors. Astigmatism has been minimized by a compact mirror placement. Precise alignment of the kinematic array was realized using our own mirror mount design. A small signal gain of 5 for 8 passes at a pump power of 400 W was reached. The laser was running for more than 3 months without the need of realignment. Pointing stability studies is also reported here.
△ Less
Submitted 18 September, 2015;
originally announced September 2015.
-
Experiments towards resolving the proton charge radius puzzle
Authors:
A. Antognini,
K. Schuhmann,
F. D. Amaro,
P. Amaro,
M. Abdou-Ahmed,
F. Biraben,
T. -L. Chen,
D. S. Covita,
A. J. Dax,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. L. Gouvea,
J. Götzfried,
T. Graf,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien,
K. Kirch,
A. Knecht,
F. Kottmann,
J. J. Krauth,
Y. -W. Liu
, et al. (12 additional authors not shown)
Abstract:
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
△ Less
Submitted 17 October, 2015; v1 submitted 10 September, 2015;
originally announced September 2015.
-
Multipass laser cavity for efficient transverse illumination of an elongated volume
Authors:
Jan Vogelsang,
Marc Diepold,
Aldo Antognini,
Andreas Dax,
Johannes Götzfried,
Theodor W. Hänsch,
Franz Kottmann,
Julian J. Krauth,
Yi-Wei Liu,
Tobias Nebel,
Francois Nez,
Karsten Schuhmann,
David Taqqu,
Randolf Pohl
Abstract:
A multipass laser cavity is presented which can be used to illuminate an elongated volume from a transverse direction. The illuminated volume can also have a very large transverse cross section. Convenient access to the illuminated volume is granted. The multipass cavity is very robust against misalignment, and no active stabilization is needed. The scheme is suitable for example in beam experimen…
▽ More
A multipass laser cavity is presented which can be used to illuminate an elongated volume from a transverse direction. The illuminated volume can also have a very large transverse cross section. Convenient access to the illuminated volume is granted. The multipass cavity is very robust against misalignment, and no active stabilization is needed. The scheme is suitable for example in beam experiments, where the beam path must not be blocked by a laser mirror, or if the illuminated volume must be very large. This cavity was used for the muonic-hydrogen experiment in which 6 $μ$m laser light illuminated a volume of 7 x 25 x 176 mm^3, using mirrors that are only 12 mm in height. We present our measurement of the intensity distribution inside the multipass cavity and show that this is in good agreement with our simulation.
△ Less
Submitted 9 June, 2015;
originally announced June 2015.
-
Quantum interference effects in laser spectroscopy of muonic hydrogen, deuterium, and helium-3
Authors:
Pedro Amaro,
Beatrice Franke,
Julian J. Krauth,
Marc Diepold,
Filippo Fratini,
Laleh Safari,
Jorge Machado,
Aldo Antognini,
Franz Kottmann,
Paul Indelicato,
Randolf Pohl,
José Paulo Santos
Abstract:
Quantum interference between energetically close states is theoretically investigated, with the state structure being observed via laser spectroscopy. In this work, we focus on hyperfine states of selected hydrogenic muonic isotopes, and on how quantum interference affects the measured Lamb shift. The process of photon excitation and subsequent photon decay is implemented within the framework of n…
▽ More
Quantum interference between energetically close states is theoretically investigated, with the state structure being observed via laser spectroscopy. In this work, we focus on hyperfine states of selected hydrogenic muonic isotopes, and on how quantum interference affects the measured Lamb shift. The process of photon excitation and subsequent photon decay is implemented within the framework of nonrelativistic second-order perturbation theory. Due to its experimental interest, calculations are performed for muonic hydrogen, deuterium, and helium-3. We restrict our analysis to the case of photon scattering by incident linear polarized photons and the polarization of the scattered photons not being observed. We conclude that while quantum interference effects can be safely neglected in muonic hydrogen and helium-3, in the case of muonic deuterium there are resonances with close proximity, where quantum interference effects can induce shifts up to a few percent of the linewidth, assuming a pointlike detector. However, by taking into account the geometry of the setup used by the CREMA collaboration, this effect is reduced to less than 0.2% of the linewidth in all possible cases, which makes it irrelevant at the present level of accuracy.
△ Less
Submitted 29 August, 2015; v1 submitted 8 June, 2015;
originally announced June 2015.
-
Theory of the n=2 levels in muonic deuterium
Authors:
Julian J. Krauth,
Marc Diepold,
Beatrice Franke,
Aldo Antognini,
Franz Kottmann,
Randolf Pohl
Abstract:
The present knowledge of Lamb shift, fine- and hyperfine structure of the $\mathrm{2S}$ and $\mathrm{2P}$ states in muonic deuterium is reviewed in anticipation of the results of a first measurement of several $\mathrm{2S-2P}$ transition frequencies in muonic deuterium ($μ\mathrm{d}$). A term-by-term comparison of all available sources reveals reliable values and uncertainties of the QED and nucle…
▽ More
The present knowledge of Lamb shift, fine- and hyperfine structure of the $\mathrm{2S}$ and $\mathrm{2P}$ states in muonic deuterium is reviewed in anticipation of the results of a first measurement of several $\mathrm{2S-2P}$ transition frequencies in muonic deuterium ($μ\mathrm{d}$). A term-by-term comparison of all available sources reveals reliable values and uncertainties of the QED and nuclear structure-dependent contributions to the Lamb shift, which are essential for a determination of the deuteron rms charge radius from $μ\mathrm{d}$. Apparent discrepancies between different sources are resolved, in particular for the difficult two-photon exchange contributions. Problematic single-sourced terms are identified which require independent recalculation.
△ Less
Submitted 8 June, 2015; v1 submitted 3 June, 2015;
originally announced June 2015.
-
Improved X-ray detection and particle identification with avalanche photodiodes
Authors:
Marc Diepold,
Luis M. P. Fernandes,
Jorge Machado,
Pedro Amaro,
Marwan Abdou-Ahmed,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth,
Yi-Wei Liu
, et al. (14 additional authors not shown)
Abstract:
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to acco…
▽ More
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g. to distinguish between x-rays and MeV electrons in our experiment.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
Lifetime and population of the 2S state in muonic protium and deuterium
Authors:
Marc Diepold,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Luis M. P. Fernandes,
Adolf Giesen,
Andrea L. Gouvea,
Thomas Graf,
Theodor W. Hänsch,
Paul Indelicato,
Lucile Julien,
Cheng-Yang Kao,
Paul Knowles,
Franz Kottmann,
Eric-Olivier Le Bigot,
Yi-Wei Liu,
José A. M. Lopes,
Livia Ludhova,
Cristina M. B. Monteiro,
Françoise Mulhauser,
Tobias Nebel
, et al. (10 additional authors not shown)
Abstract:
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The sho…
▽ More
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The short-lived 2S component has a population of 1.35 +0.57 -0.33 % and a lifetime of τ_short(μd) = 138 +32 -34 ns. We see evidence for RD of long-lived μd(2S) with a lifetime of τ_long(μd) = 1.15 +0.75 -0.53 μs. This is interpreted as formation and decay of excited muonic molecules.
△ Less
Submitted 10 October, 2013; v1 submitted 25 July, 2013;
originally announced July 2013.
-
Theory of the 2S-2P Lamb shift and 2S hyperfine splitting in muonic hydrogen
Authors:
Aldo Antognini,
Franz Kottmann,
François Biraben,
Paul Indelicato,
François Nez,
Randolf Pohl
Abstract:
The 7 standard deviations between the proton rms charge radius from muonic hydrogen and the CODATA-10 value from hydrogen spectroscopy and electron-scattering has caused considerable discussions. Here, we review the theory of the 2S-2P Lamb shift and 2S hyperfine splitting in muonic hydrogen combining the published contributions and theoretical approaches. The prediction of these quantities is nec…
▽ More
The 7 standard deviations between the proton rms charge radius from muonic hydrogen and the CODATA-10 value from hydrogen spectroscopy and electron-scattering has caused considerable discussions. Here, we review the theory of the 2S-2P Lamb shift and 2S hyperfine splitting in muonic hydrogen combining the published contributions and theoretical approaches. The prediction of these quantities is necessary for the determination of both proton charge and Zemach radii from the two 2S-2P transition frequencies measured in muonic hydrogen.
△ Less
Submitted 20 November, 2012; v1 submitted 13 August, 2012;
originally announced August 2012.
-
Characterization of large area avalanche photodiodes in X-ray and VUV-light detection
Authors:
L. M. P. Fernandes,
F. D. Amaro,
A. Antognini,
J. M. R. Cardoso,
C. A. N. Conde,
O. Huot,
P. E. Knowles,
F. Kottmann,
J. A. M. Lopes,
L. Ludhova,
C. M. B. Monteiro,
F. Mulhauser,
R. Pohl,
J. M. F. dos Santos,
L. A. Schaller,
D. Taqqu,
J. F. C. A. Veloso
Abstract:
The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was…
▽ More
The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.
△ Less
Submitted 15 February, 2007;
originally announced February 2007.
-
Muonic hydrogen cascade time and lifetime of the short-lived $2S$ state
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Haensch,
V. W. Hughes,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
Y. -W. Liu,
J. A. M. Lopes,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos,
L. A. Schaller,
C. Schwob
, et al. (2 additional authors not shown)
Abstract:
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 h…
▽ More
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 hPa $\mathrm{H}_2$ room temperature gas pressure, with lifetime $τ_{2S}^\mathrm{short} = 165 ^{+38}_{-29}$ ns (i.e., $λ_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1}$ at liquid-hydrogen density) and population $ε_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56}$ % (per $μp$ atom). In addition, a value of the $μp$ cascade time, $T_\mathrm{cas}^{μp} = (37\pm5)$ ns, was found.
△ Less
Submitted 13 November, 2006;
originally announced November 2006.
-
Observation of Long-Lived Muonic Hydrogen in the 2S State
Authors:
Randolf Pohl,
Herbert Daniel,
F. Joachim Hartmann,
Peter Hauser,
Franz Kottmann,
Valery E. Markushin,
Markus Mühlbauer,
Claude Petitjean,
Wolfgang Schott,
David Taqqu,
Peter Wojciechowski-Grosshauser
Abstract:
The kinetic energy distribution of ground state muonic hydrogen atoms mu-p(1S) is determined from time-of-flight spectra measured at 4, 16, and 64 hPa H2 room-temperature gas. A 0.9 keV-component is discovered and attributed to radiationless deexcitation of long-lived mu-p(2S) atoms in collisions with H2 molecules. The analysis reveals a relative population of about 1%, and a pressure-dependent…
▽ More
The kinetic energy distribution of ground state muonic hydrogen atoms mu-p(1S) is determined from time-of-flight spectra measured at 4, 16, and 64 hPa H2 room-temperature gas. A 0.9 keV-component is discovered and attributed to radiationless deexcitation of long-lived mu-p(2S) atoms in collisions with H2 molecules. The analysis reveals a relative population of about 1%, and a pressure-dependent lifetime (e.g. (30.4 +21.4 -9.7) ns at 64 hPa) of the long-lived mu-p(2S) population, equivalent to a 2S-quench rate in mu-p(2S) + H2 collisions of (4.4 +2.1 -1.8) 10^11 s^-1 at liquid hydrogen density.
△ Less
Submitted 13 October, 2006;
originally announced October 2006.
-
Planar LAAPDs: Temperature Dependence, Performance, and Application in Low Energy X-ray Spectroscopy
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
D. S. Covita,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Hansch,
V. W. Hughes,
O. Huot,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
J. A. M. Lopes,
Y. -W. Liu,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos
, et al. (3 additional authors not shown)
Abstract:
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanc…
▽ More
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as x-ray detectors, and they were used during the last data taking period in 2003. For x-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise, hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to alpha particles are presented.
△ Less
Submitted 15 October, 2004;
originally announced October 2004.