-
Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
Authors:
KamLAND,
Super-Kamiokande Collaborations,
:,
Seisho Abe,
Minori Eizuka,
Sawako Futagi,
Azusa Gando,
Yoshihito Gando,
Shun Goto,
Takahiko Hachiya,
Kazumi Hata,
Koichi Ichimura,
Sei Ieki,
Haruo Ikeda,
Kunio Inoue,
Koji Ishidoshiro,
Yuto Kamei,
Nanami Kawada,
Yasuhiro Kishimoto,
Masayuki Koga,
Maho Kurasawa,
Tadao Mitsui,
Haruhiko Miyake,
Daisuke Morita,
Takeshi Nakahata
, et al. (290 additional authors not shown)
Abstract:
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are ob…
▽ More
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.
△ Less
Submitted 1 July, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Search for Charged Excited States of Dark Matter with KamLAND-Zen
Authors:
KamLAND-Zen collaboration,
:,
S. Abe,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
S. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake,
D. Morita,
T. Nakahata
, et al. (44 additional authors not shown)
Abstract:
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making…
▽ More
Particle dark matter could belong to a multiplet that includes an electrically charged state. WIMP dark matter ($χ^{0}$) accompanied by a negatively charged excited state ($χ^{-}$) with a small mass difference (e.g. $<$ 20 MeV) can form a bound-state with a nucleus such as xenon. This bound-state formation is rare and the released energy is $\mathcal{O}(1-10$) MeV depending on the nucleus, making large liquid scintillator detectors suitable for detection. We searched for bound-state formation events with xenon in two experimental phases of the KamLAND-Zen experiment, a xenon-doped liquid scintillator detector. No statistically significant events were observed. For a benchmark parameter set of WIMP mass $m_{χ^{0}} = 1$ TeV and mass difference $Δm = 17$ MeV, we set the most stringent upper limits on the recombination cross section times velocity $\langleσv\rangle$ and the decay-width of $χ^{-}$ to $9.2 \times 10^{-30}$ ${\rm cm^3/s}$ and $8.7 \times 10^{-14}$ GeV, respectively at 90% confidence level.
△ Less
Submitted 3 July, 2024; v1 submitted 16 November, 2023;
originally announced November 2023.
-
Radiopurity of NaI(Tl) crystals for PICOLON dark matter experiment
Authors:
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Fushimi,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ito,
T. Kishimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Intera…
▽ More
The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Interacting Massive Particles (WIMPs) using NaI(Tl) crystals. Our NaI(Tl) crystal manufactured in 2020 (Ingot #85) reached the same purity level as DAMA/LIBRA crystals. In this report, we describe the radiopurity of the new Ingot #94 crystal produced using the same purification technique as Ingot #85. The $α$-ray events were selected by pulse-shape discrimination method. The impurities in the Ingot #94, $^{232}$Th, $^{226}$Ra and $^{210}$Po radioactivity were $4.6\pm 1.2~\mathrm{μBq/kg}$, $7.9\pm 4.4~\mathrm{μBq/kg}$, and $19\pm 6~\mathrm{μBq/kg}$, which are equivalent to those of the DAMA/LIBRA crystals. The background rate in the energy region of 2-6 keV , was 2-5 events/d/kg/keV without applying a veto trigger.
△ Less
Submitted 25 September, 2023;
originally announced September 2023.
-
Life Cycle Analysis of the GRAND Experiment
Authors:
Leidy T. Vargas-Ibáñez,
Kumiko Kotera,
Odile Blanchard,
Peggy Zwolinski,
Alexis Cheffer,
Mathieu Collilieux,
Paul Lambert,
Quentin Lefèbvre,
Thomas Protois
Abstract:
The goal of our study is to assess the environmental impact of the installation and use of the Giant Radio Array for Neutrino Detection (GRAND) prototype detection units, based on the life cycle assessment (LCA) methodology, and to propose recommendations that contribute to reduce the environmental impacts of the project at later stages. The functional unit, namely the quantified description of th…
▽ More
The goal of our study is to assess the environmental impact of the installation and use of the Giant Radio Array for Neutrino Detection (GRAND) prototype detection units, based on the life cycle assessment (LCA) methodology, and to propose recommendations that contribute to reduce the environmental impacts of the project at later stages. The functional unit, namely the quantified description of the studied system and of the performance requirements it fulfills, is to detect radio signals autonomously during 20 years, with 300 detection units deployed over 200 km^2 in the Gansu province in China (corresponding to the prototype GRANDProto300). We consider four main phases: the extraction of the materials and the production of the detection units (upstream phases), the use and the end-of-life phases (downstream phases), with transportation between each step. An inventory analysis is performed for the seven components of each detection unit, based on transparent assumptions. Most of the inventory data are taken from the Idemat2021 database (Industrial Design & Engineering Materials). Our results show that the components with the highest environmental impact are the antenna structure and the battery. The most pregnant indicators are `resource use', mineral and metals'; `resource use, fossils'; `ionizing radiation, human health'; `climate change'; and `acidification'. Therefore, the actions that we recommend in the first place aim at reducing the impact of these components. They include limiting the mass of the raw material used in the antenna, changing the alloy of the antenna, considering another type of battery with an extended useful life, and the use of recycled materials for construction. As a pioneering study applying the LCA methodology to a large-scale physics experiment, this work can serve as a basis for future assessments by other collaborations.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
Measurement of cosmic-ray muon spallation products in a xenon-loaded liquid scintillator with KamLAND
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
T. Mitsui,
H. Miyake
, et al. (42 additional authors not shown)
Abstract:
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electroni…
▽ More
Cosmic-ray muons produce various radioisotopes when passing through material. These spallation products can be backgrounds for rare event searches such as in solar neutrino, double-beta decay, and dark matter search experiments. The KamLAND-Zen experiment searches for neutrinoless double-beta decay in 745kg of xenon dissolved in liquid scintillator. The experiment includes dead-time-free electronics with a high efficiency for detecting muon-induced neutrons. The production yields of different radioisotopes are measured with a combination of delayed coincidence techniques, newly developed muon reconstruction and xenon spallation identification methods. The observed xenon spallation products are consistent with results from the FLUKA and Geant4 simulation codes.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
Abundances of uranium and thorium elements in Earth estimated by geoneutrino spectroscopy
Authors:
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura,
T. Mitsui,
H. Miyake,
T. Nakahata
, et al. (43 additional authors not shown)
Abstract:
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been obs…
▽ More
The decay of the primordial isotopes $^{238}\mathrm{U}$, $^{235}\mathrm{U}$, $^{232}\mathrm{Th}$, and $^{40}\mathrm{K}$ have contributed to the terrestrial heat budget throughout the Earth's history. Hence the individual abundance of those isotopes are key parameters in reconstructing contemporary Earth model. The geoneutrinos produced by the radioactive decays of uranium and thorium have been observed with the Kamioka Liquid-Scintillator Antineutrino Detector (KamLAND). Those measurements have been improved with more than 18-year observation time, and improvements in detector background levels mainly by an 8-year almost rector-free period now permit spectroscopy with geoneutrinos. Our results yield the first constraint on both uranium and thorium heat contributions. Herein the KamLAND result is consistent with geochemical estimations based on elemental abundances of chondritic meteorites and mantle peridotites. The High-Q model is disfavored at 99.76% C.L. and a fully radiogenic model is excluded at 5.2$σ$ assuming a homogeneous heat producing element distribution in the mantle.
△ Less
Submitted 13 August, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Search for the Majorana Nature of Neutrinos in the Inverted Mass Ordering Region with KamLAND-Zen
Authors:
KamLAND-Zen Collaboration,
:,
S. Abe,
S. Asami,
M. Eizuka,
S. Futagi,
A. Gando,
Y. Gando,
T. Gima,
A. Goto,
T. Hachiya,
K. Hata,
S. Hayashida,
K. Hosokawa,
K. Ichimura,
S. Ieki,
H. Ikeda,
K. Inoue,
K. Ishidoshiro,
Y. Kamei,
N. Kawada,
Y. Kishimoto,
M. Koga,
M. Kurasawa,
N. Maemura
, et al. (50 additional authors not shown)
Abstract:
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable…
▽ More
The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta ($0νββ$) decay half-life in $^{136}$Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of $^{136}$Xe. These new data provide valuable insight into backgrounds, especially from cosmic muon spallation of xenon, and have required the use of novel background rejection techniques. We obtain a lower limit for the $0νββ$ decay half-life of $T_{1/2}^{0ν} > 2.3 \times 10^{26}$ yr at 90% C.L., corresponding to upper limits on the effective Majorana neutrino mass of 36-156 meV using commonly adopted nuclear matrix element calculations.
△ Less
Submitted 16 February, 2023; v1 submitted 4 March, 2022;
originally announced March 2022.
-
PICOLON dark matter search project
Authors:
K. Fushimi,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kishimoto,
M. Koga,
K. Kotera,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
Y. Yamamoto,
K. Yasuda,
S. Yoshida
Abstract:
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory.…
▽ More
PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory. The sensitivity for annual modulating signals and finding dark matter particles will be discussed.
△ Less
Submitted 19 December, 2021;
originally announced December 2021.
-
Dark matter search with high purity NaI(Tl) scintillator
Authors:
K. Fushimi,
Y. Kanemitsu,
K. Kotera,
D. Chernyak,
H. Ejiri,
K. Hata,
R. Hazama,
T. Iida,
H. Ikeda,
K. Imagawa,
K. Inoue,
H. Ishiura,
H. Ito,
T. Kisimoto,
M. Koga,
A. Kozlov,
K. Nakamura,
R. Orito,
T. Shima,
Y. Takemoto,
S. Umehara,
Y. Urano,
K. Yasuda,
S. Yoshida
Abstract:
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were le…
▽ More
A dark matter search project needs and extremely low background radiation detector since the expected event rate of dark matter is less than a few events in one year in one tonne of the detector mass. The authors developed a highly radiopure NaI(Tl) crystal to search for dark matter. The best combination of the purification methods was developed, resulting $^{\mathrm{nat}}$K and $^{210}$Pb were less than 20 ppb and 5.7 $μ$Bq/kg, respectively.
The authors will construct a large volume detector system with high-purity NaI(Tl) crystals. The design and the performance of the prototype detector module will be reported in this article.
△ Less
Submitted 29 June, 2021;
originally announced June 2021.
-
Estimating the carbon footprint of the GRAND Project, a multi-decade astrophysics experiment
Authors:
Clarisse Aujoux,
Kumiko Kotera,
Odile Blanchard
Abstract:
We present a pioneering estimate of the global yearly greenhouse gas emissions of a large-scale Astrophysics experiment over several decades: the Giant Array for Neutrino Detection (GRAND). The project aims at detecting ultra-high energy neutrinos with a 200,000 radio antenna array over 200,000\,km$^2$ as of the 2030s. With a fully transparent methodology based on open source data, we calculate th…
▽ More
We present a pioneering estimate of the global yearly greenhouse gas emissions of a large-scale Astrophysics experiment over several decades: the Giant Array for Neutrino Detection (GRAND). The project aims at detecting ultra-high energy neutrinos with a 200,000 radio antenna array over 200,000\,km$^2$ as of the 2030s. With a fully transparent methodology based on open source data, we calculate the emissions related to three unavoidable sources: travel, digital technologies and hardware equipment. We find that these emission sources have a different impact depending on the stages of the experiment. Digital technologies and travel prevail for the small-scale prototy** phase (GRANDProto300), whereas hardware equipment (material production and transportation) and data transfer/storage largely outweigh the other emission sources in the large-scale phase (GRAND200k). In the mid-scale phase (GRAND10k), the three sources contribute equally. This study highlights the considerable carbon footprint of a large-scale astrophysics experiment, but also shows that there is room for improvement. We discuss various lines of actions that could be implemented. The GRAND project being still in its prototy** stage, our results provide guidance to the future collaborative practices and instrumental design in order to reduce its carbon footprint.
△ Less
Submitted 10 May, 2021; v1 submitted 6 January, 2021;
originally announced January 2021.
-
Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System
Authors:
CALICE Collaboration,
J. Repond,
L. Xia,
J. Apostolakis,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
V. Francais,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Gttlicher,
O. Hartbrich F. Krivan,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza
, et al. (84 additional authors not shown)
Abstract:
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles.…
▽ More
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
△ Less
Submitted 12 September, 2018; v1 submitted 11 September, 2018;
originally announced September 2018.
-
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
Authors:
CALICE collaboration,
J. Repond,
L. Xia,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
M. A. Thomson,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
F. Krivan,
K. Krüger,
S. Lu,
B. Lutz,
M. Reinecke,
F. Sefkow,
Y. Sudo,
H. L. Tran,
A. Kaplan,
H. -Ch. Schultz-Coulon
, et al. (57 additional authors not shown)
Abstract:
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab…
▽ More
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.
△ Less
Submitted 28 February, 2018; v1 submitted 22 July, 2017;
originally announced July 2017.
-
Resistive Plate Chamber Digitization in a Hadronic Shower Environment
Authors:
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
J. Apostolakis,
G. Folger,
C. Grefe,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
C. Carloganu,
V. Français,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
S. Cauwenbergh,
M. Tytgat,
A. **ault,
N. Zaganidis,
E. Brianne,
A. Ebrahimi
, et al. (103 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, e…
▽ More
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
Optimization of layer composition for ILD ECAL
Authors:
Hiroki Sumida,
Masato Matama,
Yuji Sudo,
Taikan Suehara,
Tamaki Yoshioka,
Kiyotomo Kawagoe,
Daniel Jeans,
Tohru Takeshita,
Katsushige Kotera
Abstract:
International Large Detector (ILD) adopts Particle Flow Algorithm (PFA) for precise measurement of multiple jets. The electromagnetic calorimeter (ECAL) of ILD has two candidates sensor technologies for PFA, which are pixelized silicon sensors and scintillator-strips with silicon photomultipliers. Pixelized silicon sensors have higher granularity for PFA, however they have an issue of cost reducti…
▽ More
International Large Detector (ILD) adopts Particle Flow Algorithm (PFA) for precise measurement of multiple jets. The electromagnetic calorimeter (ECAL) of ILD has two candidates sensor technologies for PFA, which are pixelized silicon sensors and scintillator-strips with silicon photomultipliers. Pixelized silicon sensors have higher granularity for PFA, however they have an issue of cost reduction. In contrast, scintillator-strips have an advantage of relatively low cost and a disadvantage of degradation of position resolution by ghost hits, which are generated by orthogonal arrangement. Hybrid ECAL using both candidates is proposed to supplement these disadvantages. In this paper, we report an optimization study of the hybrid ECAL using detector simulation.
△ Less
Submitted 14 March, 2016;
originally announced March 2016.
-
DHCAL with Minimal Absorber: Measurements with Positrons
Authors:
The CALICE Collaboration,
B. Freund,
C. Neubüser,
J. Repond,
J. Schlereth,
L. Xia,
A. Dotti,
C. Grefe,
V. Ivantchenko,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg,
A. Irles,
F. Krivan,
K. Krüger
, et al. (78 additional authors not shown)
Abstract:
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on…
▽ More
In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.
△ Less
Submitted 4 March, 2016;
originally announced March 2016.
-
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
Authors:
The CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
J. -Y. Hostachy,
L. Morin,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg
, et al. (135 additional authors not shown)
Abstract:
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test be…
▽ More
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
△ Less
Submitted 15 March, 2016; v1 submitted 27 February, 2016;
originally announced February 2016.
-
Describing the response of saturated SiPMs
Authors:
Katsushige Kotera,
Weonseok Choi,
Tohru Takeshita
Abstract:
We have developed a function which describes SiPM response in both small signal and highly saturated regimes. The function includes the reactivation of SiPM pixels during a single input light pulse, and results in an approximately linear increase of SiPM response in the highly saturated regime, as observed in real SiPMs. This article shows that the function can accurately describe the measured res…
▽ More
We have developed a function which describes SiPM response in both small signal and highly saturated regimes. The function includes the reactivation of SiPM pixels during a single input light pulse, and results in an approximately linear increase of SiPM response in the highly saturated regime, as observed in real SiPMs. This article shows that the function can accurately describe the measured response of real SiPM devices over a wide range of signal intensities.
△ Less
Submitted 18 March, 2016; v1 submitted 5 October, 2015;
originally announced October 2015.
-
Extraction Method of Fine Granular Performance from Scintillator Strip Electromagnetic Calorimeter
Authors:
Katsushige Kotera,
Daniel Jeans,
Akiya Miyamoto,
Tohru Takeshita
Abstract:
We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle flow reconstruction to future experiments in high energy physics. Tests of this algorithm in full detector simulations, using strips of size 45 x 5 mm^2 show tha…
▽ More
We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle flow reconstruction to future experiments in high energy physics. Tests of this algorithm in full detector simulations, using strips of size 45 x 5 mm^2 show that the performance is close to that of a calorimeter with true 5 x 5 mm^2 readout granularity. The performance can be further improved by the use of 10 x 10 mm^2 tile- shaped layers interspersed between strip layers.
△ Less
Submitted 24 May, 2014; v1 submitted 17 May, 2014;
originally announced May 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
Scintillator Strip ECAL Optimization
Authors:
Katsushige Kotera
Abstract:
The CALICE collaboration is develo** a granular electromagnetic calorimeter using small scintillator strips for a future linear collider experiment. On develo** of ~ 10^7 channel-ECAL in particle flow approach, CALICE is develo** a technological prototype with 144 of 5 x 45 x (1 - 2) mm^3 strips on each 180 x 180 mm^2 base board unit in tandem with develo** the design of scintillator strip…
▽ More
The CALICE collaboration is develo** a granular electromagnetic calorimeter using small scintillator strips for a future linear collider experiment. On develo** of ~ 10^7 channel-ECAL in particle flow approach, CALICE is develo** a technological prototype with 144 of 5 x 45 x (1 - 2) mm^3 strips on each 180 x 180 mm^2 base board unit in tandem with develo** the design of scintillator strip and pixelated photon detector and their coupling after established the physics prototype which has required performance. A method of event reconstruction in such ECAL is also developed.
△ Less
Submitted 7 April, 2014;
originally announced April 2014.
-
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
Authors:
CALICE Collaboration,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon
, et al. (169 additional authors not shown)
Abstract:
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur…
▽ More
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
△ Less
Submitted 11 June, 2014; v1 submitted 15 November, 2013;
originally announced November 2013.
-
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada
, et al. (194 additional authors not shown)
Abstract:
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain hig…
▽ More
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain high-energy showers, while allowing a compact size for the surrounding solenoid.
A fine-grained calorimeter prototype with tungsten absorber plates and scintillator tiles read out by silicon photomultipliers was built and exposed to particle beams at CERN. Results obtained with electrons, pions and protons of momenta up to 10 GeV are presented in terms of energy resolution and shower shape studies. The results are compared with several GEANT4 simulation models in order to assess the reliability of the Monte Carlo predictions relevant for a future experiment at CLIC.
△ Less
Submitted 13 January, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.
-
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
Authors:
CALICE Collaboration,
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (184 additional authors not shown)
Abstract:
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul…
▽ More
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.
△ Less
Submitted 29 July, 2013; v1 submitted 30 May, 2013;
originally announced May 2013.
-
Performance of the CALICE Scintillator-Based ECAL Depending on the Temperature
Authors:
Katsushige Kotera
Abstract:
The CALICE collaboration is develo** a granular electromagnetic calorimeter using (5-10) mm x 45 mm x 3 mm scintillator strips for a future linear collider experiment. Each scintillator strip is read out by using a Pixelated Photon Detector (PPD). A prototype module has been constructed and tested at Fermilab in 2008 and 2009. Since the sensitivity of the PPD is affected by temperature fluctuati…
▽ More
The CALICE collaboration is develo** a granular electromagnetic calorimeter using (5-10) mm x 45 mm x 3 mm scintillator strips for a future linear collider experiment. Each scintillator strip is read out by using a Pixelated Photon Detector (PPD). A prototype module has been constructed and tested at Fermilab in 2008 and 2009. Since the sensitivity of the PPD is affected by temperature fluctuations, a temperature correction method has been established which performed such that the deviation of the measured response from a linear behavior is improved from greater than 10% to less than 1.5%.
△ Less
Submitted 31 January, 2012; v1 submitted 29 January, 2012;
originally announced January 2012.
-
The Pierre Auger Observatory V: Enhancements
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Ongoing and planned enhancements of the Pierre Auger Observatory
Ongoing and planned enhancements of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.
-
The Pierre Auger Observatory IV: Operation and Monitoring
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Technical reports on operations and monitoring of the Pierre Auger Observatory
Technical reports on operations and monitoring of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.
-
Electromagnetic response of a highly granular hadronic calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
Y. Mikami,
N. K. Watson T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward W. Yan
, et al. (142 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individuall…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM).
A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes.
The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.
△ Less
Submitted 8 June, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Status of Simulation Tools for the ILD ScECAL
Authors:
Katsushige Kotera,
Marc Anduze,
Vincent Boudry,
Jean-Claude Brient,
Daniel Jeans,
Kiyotomo Kawagoe,
Akiya Miyamoto,
Paulo Mora de Freitas,
Gabriel Musat,
Hiroaki Ono,
Tohru Takeshita,
Satoru Uozumi
Abstract:
The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technic for the ILC. To achieve the fine granularity from the strip-segmented layers the strips in odd layers are orthogonal with respect to those in the even layers. In order to extract the best performance from such detector concept, a special reconstruction method and simulation tools are being developed in IL…
▽ More
The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technic for the ILC. To achieve the fine granularity from the strip-segmented layers the strips in odd layers are orthogonal with respect to those in the even layers. In order to extract the best performance from such detector concept, a special reconstruction method and simulation tools are being developed in ILD collaboration. This manuscript repots the status of develo** of those tools.
△ Less
Submitted 18 June, 2010;
originally announced June 2010.
-
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
A. Brandt,
H. Brown,
K. De,
C. Medina,
J. Smith,
J. Li,
M. Sosebee,
A. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada
, et al. (205 additional authors not shown)
Abstract:
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.…
▽ More
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.
△ Less
Submitted 12 March, 2010;
originally announced March 2010.