Snowmass 2021 White Paper on Upgrading SuperKEKB with a Polarized Electron Beam: Discovery Potential and Proposed Implementation
Authors:
A. Accardi,
D. M. Asner,
H. Atmacan,
R. Baartman,
Sw. Banerjee,
A. Beaubien,
J. V. Bennett,
M. Bertemes,
M. Bessner,
D. Biswas,
G. Bonvicini,
N. Brenny,
R. A. Briere,
T. E. Browder,
C. Chen,
S. Choudhury,
D. Cinabro,
J. Cochran,
L. M. Cremaldi,
W. Deconinck,
A. Di Canto,
S. Dubey,
K. Flood,
B. G. Fulsom,
V. Gaur
, et al. (83 additional authors not shown)
Abstract:
Upgrading the SuperKEKB electron-positron collider with polarized electron beams opens a new program of precision physics at a center-of-mass energy of 10.58 GeV. This white paper describes the physics potential of this `Chiral Belle' program. It includes projections for precision measurements of $\sin^2θ_W$ that can be obtained from independent left-right asymmetry measurements of $e^+e^-$ transi…
▽ More
Upgrading the SuperKEKB electron-positron collider with polarized electron beams opens a new program of precision physics at a center-of-mass energy of 10.58 GeV. This white paper describes the physics potential of this `Chiral Belle' program. It includes projections for precision measurements of $\sin^2θ_W$ that can be obtained from independent left-right asymmetry measurements of $e^+e^-$ transitions to pairs of electrons, muons, taus, charm and b-quarks. The $\sin^2θ_W$ precision obtainable at SuperKEKB will match that of the LEP/SLC world average, but at the centre-of-mass energy of 10.58 GeV. Measurements of the couplings for muons, charm, and $b$-quarks will be substantially improved and the existing $3σ$ discrepancy between the SLC $A_{LR}$ and LEP $A_{FB}^b$ measurements will be addressed. Precision measurements of neutral current universality will be more than an order of magnitude more precise than currently available. As the energy scale is well away from the $Z^0$-pole, the precision measurements will have sensitivity to the presence of a parity-violating dark sector gauge boson, $Z_{\rm dark}$. The program also enables the measurement of the anomalous magnetic moment $g-2$ form factor of the $τ$ to be made at an unprecedented level of precision. A precision of $10^{-5}$ level is accessible with 40~ab$^{-1}$ and with more data it would start to approach the $10^{-6}$ level. This technique would provide the most precise information from the third generation about potential new physics explanations of the muon $g-2$ $4σ$ anomaly. Additional $τ$ and QCD physics programs enabled or enhanced with having polarized electron beams are also discussed in this White Paper. This paper includes a summary of the path forward in R&D and next steps required to implement this upgrade and access its exciting discovery potential.
△ Less
Submitted 13 September, 2022; v1 submitted 25 May, 2022;
originally announced May 2022.
-
Possibility to investigate P-parity violation in nuclear collisions at facility NICA
Authors:
I. A. Koop,
A. I. Milstein,
N. N. Nikolaev,
A. S. Popov,
S. G. Salnikov,
P. Yu. Shatunov,
Yu. M. Shatunov
Abstract:
A possible experimental setup for measuring the effect of parity violation in the interaction of the polarized proton or deuteron beams with an unpolarized target is discussed. One possibility is investigation of scattering of the proton or deuteron polarized beams on a thick internal target in one of the rings of the NICA collider. In this case, the spin of a circulating particles is transformed…
▽ More
A possible experimental setup for measuring the effect of parity violation in the interaction of the polarized proton or deuteron beams with an unpolarized target is discussed. One possibility is investigation of scattering of the proton or deuteron polarized beams on a thick internal target in one of the rings of the NICA collider. In this case, the spin of a circulating particles is transformed into a mode precessing in the horizontal plane using an RF flipper. The effect of parity violation will be studied by measuring the correlation of the interaction cross section of particles and the direction of their spins. In an alternative approach, the flipper transforms the spins of particles into a horizontal plane and the beam is extracted into the channel in a certain phase of the precession. In this more traditional experimental setup, the total cross section of the passage of particles through a dense target is measured, depending on the sign of the helicity of the polarization of the beam.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Polarization and Centre-of-mass Energy Calibration at FCC-ee
Authors:
Alain Blondel,
Patrick Janot,
Jörg Wenninger,
Ralf Aßmann,
Sandra Aumon,
Paolo Azzurri,
Desmond P. Barber,
Michael Benedikt,
Anton V. Bogomyagkov,
Eliana Gianfelice-Wendt,
Dima El Kerchen,
Ivan A. Koop,
Mike Koratzinos,
Evgeni Levitchev,
Thibaut Lefevre,
Attilio Milanese,
Nickolai Muchnoi,
Sergey A. Nikitin,
Katsunobu Oide,
Emmanuel Perez,
Robert Rossmanith,
David C. Sagan,
Roberto Tenchini,
Tobias Tydecks,
Dmitry Shatilov
, et al. (3 additional authors not shown)
Abstract:
The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with samples of $5 \times 10^{12}$ Z bosons, $10^8$ W pairs, $10^6$ Higgs bosons and $10^6$ top quark pairs. A cornerstone of the physics program lays in the precise (ppm…
▽ More
The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with samples of $5 \times 10^{12}$ Z bosons, $10^8$ W pairs, $10^6$ Higgs bosons and $10^6$ top quark pairs. A cornerstone of the physics program lays in the precise (ppm) measurements of the W and Z masses and widths, as well as forward-backward asymmetries. To this effect the centre-of-mass energy distribution should be determined with the high precision. This document describes the capacity offered by FCC-ee, starting with transverse polarization of the beams around the Z pole and the W pair threshold. A running scheme based on regular measurements of the beam energy by resonant depolarization of pilot bunches, during physics data taking, is proposed. The design for polarization wigglers, polarimeter and depolarizer is outlined. The $e^\pm$ beam energies will be monitored with a relative precision of $10^{-6}$. The centre-of-mass energy is derived subject to further corrections, related to the beam acceleration, synchrotron radiation and beamstrahlung; these effects are identified and evaluated. Dimuon events $e^+e^- \to μ^+ μ^-$, recorded in the detectors, provide with great precision the beam crossing angle, the centre-of-mass energy spread, and the $e^+$ and $e^-$ energy difference. Monitoring methods to minimize absolute error and relative uncertainties are discussed. The impact on the physics measurements is given. A programme of further simulations, design, monitoring and R&D is outlined.
△ Less
Submitted 26 September, 2019;
originally announced September 2019.
-
Correction of magnetic optics and beam trajectory using LOCO based algorithm with expanded experimental data sets
Authors:
A. Romanov,
D. Edstrom Jr.,
F. A. Emanov,
I. A. Koop,
E. A. Perevedentsev,
Yu. A. Rogovsky,
D. B. Shwartz,
A. Valishev
Abstract:
Precise beam based measurement and correction of magnetic optics is essential for the successful operation of accelerators. The LOCO algorithm is a proven and reliable tool, which in some situations can be improved by using a broader class of experimental data. The standard data sets for LOCO include the closed orbit responses to dipole corrector variation, dispersion, and betatron tunes. This pap…
▽ More
Precise beam based measurement and correction of magnetic optics is essential for the successful operation of accelerators. The LOCO algorithm is a proven and reliable tool, which in some situations can be improved by using a broader class of experimental data. The standard data sets for LOCO include the closed orbit responses to dipole corrector variation, dispersion, and betatron tunes. This paper discusses the benefits from augmenting the data with four additional classes of experimental data: the beam shape measured with beam profile monitors; responses of closed orbit bumps to focusing field variations; betatron tune responses to focusing field variations; BPM-to-BPM betatron phase advances and beta functions in BPMs from turn-by-turn coordinates of kicked beam. All of the described features were implemented in the Sixdsimulation software that was used to correct the optics of the VEPP-2000 collider, the VEPP-5 injector booster ring, and the FAST linac.
△ Less
Submitted 28 March, 2017;
originally announced March 2017.
-
A Storage Ring Experiment to Detect a Proton Electric Dipole Moment
Authors:
V. Anastassopoulos,
S. Andrianov,
R. Baartman,
M. Bai,
S. Baessler,
J. Benante,
M. Berz,
M. Blaskiewicz,
T. Bowcock,
K. Brown,
B. Casey,
M. Conte,
J. Crnkovic,
G. Fanourakis,
A. Fedotov,
P. Fierlinger,
W. Fischer,
M. O. Gaisser,
Y. Giomataris,
M. Grosse-Perdekamp,
G. Guidoboni,
S. Haciomeroglu,
G. Hoffstaetter,
H. Huang,
M. Incagli
, et al. (66 additional authors not shown)
Abstract:
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the…
▽ More
A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.
△ Less
Submitted 15 February, 2015;
originally announced February 2015.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
A system of beam energy measurement based on the Compton backscattered laser photons for the VEPP-2000 electron-positron collider
Authors:
E. V. Abakumova,
M. N. Achasov,
D. E. Berkaev,
V. V. Kaminsky,
I. A. Koop,
A. A. Korol,
S. V. Koshuba,
A. A. Krasnov,
N. Yu. Muchnoi,
E. A. Perevedentsev,
E. E. Pyata,
P. Yu. Shatunov,
Yu. M. Shatunov,
D. B. Shwartz
Abstract:
The beam energy measurement system for the VEPP-2000 electron-positron collider is described. The method of Compton backscattering of $CO$ laser photons on the electron beam is used. The relative systematic uncertainty of the beam energy determination is estimated as 6\cdot10^{-5}. It was obtained through comparison of the results of the beam energy measurements using the Compton backscattering an…
▽ More
The beam energy measurement system for the VEPP-2000 electron-positron collider is described. The method of Compton backscattering of $CO$ laser photons on the electron beam is used. The relative systematic uncertainty of the beam energy determination is estimated as 6\cdot10^{-5}. It was obtained through comparison of the results of the beam energy measurements using the Compton backscattering and resonance depolarization methods.
△ Less
Submitted 29 October, 2013;
originally announced October 2013.
-
VEPP-2000 Project
Authors:
I. A. Koop
Abstract:
The status of VEPP-2000 collider is presented. Implementation of Round Colliding Beams (RCB) concept in the new collider VEPP-2000 is outlined, potential advantages of RCB over the flat colliding beams are discussed. The main design parameters and features of this VEPP-2000 collider are reported.
The status of VEPP-2000 collider is presented. Implementation of Round Colliding Beams (RCB) concept in the new collider VEPP-2000 is outlined, potential advantages of RCB over the flat colliding beams are discussed. The main design parameters and features of this VEPP-2000 collider are reported.
△ Less
Submitted 4 June, 2001;
originally announced June 2001.