Skip to main content

Showing 1–20 of 20 results for author: Koo, B

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.09442  [pdf

    physics.med-ph cs.LG physics.app-ph physics.bio-ph

    An insertable glucose sensor using a compact and cost-effective phosphorescence lifetime imager and machine learning

    Authors: Artem Goncharov, Zoltan Gorocs, Ridhi Pradhan, Brian Ko, Ajmal Ajmal, Andres Rodriguez, David Baum, Marcell Veszpremi, Xilin Yang, Maxime Pindrys, Tianle Zheng, Oliver Wang, Jessica C. Ramella-Roman, Michael J. McShane, Aydogan Ozcan

    Abstract: Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cos… ▽ More

    Submitted 11 June, 2024; originally announced June 2024.

    Comments: 24 Pages, 4 Figures

  2. arXiv:2406.07782  [pdf, other

    hep-ph hep-ex physics.ins-det

    Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears

    Authors: A. K. Yi, T. Seong, S. Lee, S. Ahn, B. I. Ivanov, S. V. Uchaikin, B. R. Ko, Y. K. Semertzidis

    Abstract: Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable fre… ▽ More

    Submitted 8 July, 2024; v1 submitted 11 June, 2024; originally announced June 2024.

    Comments: 12 pages, 8 figures, JINST accepcted

  3. arXiv:2312.10632  [pdf

    physics.med-ph

    Dosimetric calibration of an anatomically specific ultra-high dose rate electron irradiation platform for preclinical FLASH radiobiology experiments

    Authors: **ghui Wang, Stavros Melemenidis, Rakesh Manjappa, Vignesh Viswanathan, Ramish M. Ashraf, Karen Levy, Lawrie Skinner, Luis A. Soto, Stephanie Chow, Brianna Lau, Ryan B. Ko, Edward E. Graves, Amy S. Yu, Karl K. Bush, Murat Surucu, Erinn B. Rankin, Billy W. Loo Jr, Emil Schüler, Peter G. Maxim

    Abstract: We characterized the dosimetric properties of a clinical linear accelerator configured to deliver ultra-high dose rate (UHDR) irradiation to mice and cell-culture FLASH radiobiology experiments. UHDR electron beams were controlled by a microcontroller and relay interfaced with the respiratory gating system. We produced beam collimators with indexed stereotactic mouse positioning devices to provide… ▽ More

    Submitted 17 December, 2023; originally announced December 2023.

    Comments: **ghui Wang and Stavros Melemenidis are co-first authors, and Emil Schüler and Peter G. Maxim are co-senior/co-corresponding authors

  4. arXiv:2209.15121  [pdf, other

    q-bio.BM cs.CV eess.IV physics.chem-ph

    Heterogeneous reconstruction of deformable atomic models in Cryo-EM

    Authors: Youssef Nashed, Ariana Peck, Julien Martel, Axel Levy, Bong** Koo, Gordon Wetzstein, Nina Miolane, Daniel Ratner, Frédéric Poitevin

    Abstract: Cryogenic electron microscopy (cryo-EM) provides a unique opportunity to study the structural heterogeneity of biomolecules. Being able to explain this heterogeneity with atomic models would help our understanding of their functional mechanisms but the size and ruggedness of the structural space (the space of atomic 3D cartesian coordinates) presents an immense challenge. Here, we describe a heter… ▽ More

    Submitted 29 September, 2022; originally announced September 2022.

    Comments: 8 pages, 1 figure

  5. arXiv:2203.12037  [pdf, other

    physics.ins-det hep-ex

    Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, T. Beyrouthy, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi , et al. (157 additional authors not shown)

    Abstract: The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co… ▽ More

    Submitted 22 March, 2022; originally announced March 2022.

    Comments: 45 pages, 39 figures, submitted to Nuclear Instruments and Methods in Physics Research Section A

  6. arXiv:2111.03902  [pdf, other

    physics.ins-det hep-ex

    Development of an FPGA-based realtime DAQ system for axion haloscope experiments

    Authors: MyeongJae Lee, ByeongRok Ko, Saebyeok Ahn

    Abstract: A real-time Data Acquisition (DAQ) system for the CULTASK axion haloscope experiment was constructed and tested. The CULTASK is an experiment to search for cosmic axions using resonant cavities, to detect photons from axion conversion through the inverse Primakoff effect in a few GHz frequency range in a very high magnetic field and at an ultra low temperature. The constructed DAQ system utilizes… ▽ More

    Submitted 6 November, 2021; originally announced November 2021.

    Journal ref: Journal of Instrumentation, volume 16, T11008 (2021)

  7. arXiv:2109.08312  [pdf, other

    physics.ins-det hep-ex

    Fast DAQ system with image rejection for axion dark matter searches

    Authors: S. Ahn, M. J. Lee, A. K. Yi, B. Yeo, B. R. Ko, Y. K. Semertzidis

    Abstract: A fast data acquisition (DAQ) system for axion dark matter searches utilizing a microwave resonant cavity, also known as axion haloscope searches, has been developed with a two-channel digitizer that can sample 16-bit amplitudes at rates up to 180 MSamples/s. First, we realized a practical DAQ efficiency of greater than 99% for a single DAQ channel, where the DAQ process includes the online fast F… ▽ More

    Submitted 17 April, 2022; v1 submitted 16 September, 2021; originally announced September 2021.

    Comments: 14 pages, 8 figures, 3 tables. JINST accepted

  8. arXiv:2109.01141  [pdf

    physics.optics physics.app-ph

    Metasurface Holography over 90% Efficiency in the Visible via Nanoparticle-Embedded-Resin Printing

    Authors: Joohoon Kim, Dong Kyo Oh, Hongyoon Kim, Gwanho Yoon, Chunghwan Jung, Jae Kyung Kim, Trevon Badloe, Seokwoo Kim, Younghwan Yang, Jihae Lee, Byoungsu Ko, Jong G. Ok, Junsuk Rho

    Abstract: Metasurface holography, the reconstruction of holographic images by modulating the spatial amplitude and phase of light using metasurfaces, has emerged as a next-generation display technology. However, conventional fabrication techniques used to realize metaholograms are limited by their small patterning areas, high manufacturing costs, and low throughput, which hinder their practical use. Herein,… ▽ More

    Submitted 2 September, 2021; originally announced September 2021.

  9. arXiv:2107.09364  [pdf, other

    physics.ins-det hep-ex

    Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi, O. Bouhali , et al. (156 additional authors not shown)

    Abstract: After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr… ▽ More

    Submitted 22 September, 2021; v1 submitted 20 July, 2021; originally announced July 2021.

    Comments: 10 pages, 5 figures

  10. arXiv:2107.03621  [pdf, other

    physics.ins-det hep-ex

    Modeling the triple-GEM detector response to background particles for the CMS Experiment

    Authors: M. Abbas, M. Abbrescia, H. Abdalla, A. Abdelalim, S. AbuZeid, A. Agapitos, A. Ahmad, A. Ahmed, W. Ahmed, C. Aimè, C. Aruta, I. Asghar, P. Aspell, C. Avila, I. Azhgirey, J. Babbar, Y. Ban, R. Band, S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi , et al. (164 additional authors not shown)

    Abstract: An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The… ▽ More

    Submitted 8 July, 2021; originally announced July 2021.

    Comments: 16 pages, 9 figures, 6 tables

  11. arXiv:2101.09566  [pdf, other

    physics.app-ph eess.SY

    Isogeometric Configuration Design Optimization of Three-dimensional Curved Beam Structures for Maximal Fundamental Frequency

    Authors: Myung-** Choi, Jae-Hyun Kim, Bonyong Koo, Seonho Cho

    Abstract: This paper presents a configuration design optimization method for three-dimensional curved beam built-up structures having maximized fundamental eigenfrequency. We develop the method of computation of design velocity field and optimal design of beam structures constrained on a curved surface, where both designs of the embedded beams and the curved surface are simultaneously varied during the opti… ▽ More

    Submitted 23 January, 2021; originally announced January 2021.

    Comments: This document is the personal version of an article whose final publication is available at https://doi.org/10.1007/s00158-020-02803-0

    Journal ref: Structural and Multidisciplinary Optimization, 2021

  12. arXiv:2007.07468  [pdf, other

    physics.ins-det hep-ex

    CAPP-8TB: Axion Dark Matter Search Experiment around 6.7 $μ$eV

    Authors: J. Choi, S. Ahn, B. R. Ko, S. Lee, Y. K. Semertzidis

    Abstract: CAPP-8TB is an axion dark matter search experiment dedicated to an axion mass search near 6.7 $μ$eV. The experiment uses a microwave resonant cavity under a strong magnetic field of 8 T produced by a superconducting solenoid magnet in a dilution refrigerator. We describe the experimental configuration used to search for a mass range of 6.62 to 6.82 $μ$eV in the first phase of the experiment. We al… ▽ More

    Submitted 14 July, 2020; originally announced July 2020.

    Comments: 18 pages, 21 figures

  13. arXiv:1910.11591  [pdf, other

    physics.ins-det hep-ex

    Axion Dark Matter Research with IBS/CAPP

    Authors: Yannis K. Semertzidis, Jihn E. Kim, SungWoo Youn, Jihoon Choi, Woohyun Chung, Selcuk Haciomeroglu, Dongmin Kim, **geun Kim, ByeongRok Ko, Ohjoon Kwon, Andrei Matlashov, Lino Miceli, Hiroaki Natori, Seongtae Park, MyeongJae Lee, Soohyung Lee, Elena Sala, Yunchang Shin, Taehyeon Seong, Sergey Uchaykin, Danho Ahn, Saebyeok Ahn, Seung Pyo Chang, Wheeyeon Cheong, Hoyong Jeong , et al. (12 additional authors not shown)

    Abstract: The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on th… ▽ More

    Submitted 25 October, 2019; originally announced October 2019.

    Comments: 156 pages, 135 figures, conceptual/technical design report

  14. arXiv:1910.00047  [pdf, other

    hep-ex physics.ins-det

    CAPP-8TB: Search for Axion Dark Matter in a Mass Range of 6.62 to 7.04 $μ$eV

    Authors: Soohyung Lee, Saebyeok Ahn, Jihoon Choi, Byeong Rok Ko, Yannis K. Semertzidis

    Abstract: The axion is a hypothetical particle proposed to solve the strong $CP$ problem, and also a candidate for dark matter. This non-relativistic particle in the galactic halo can be converted into a photon under a strong magnetic field and detected with a microwave resonant cavity. Relying on this detection method, many experiments have excluded some mass regions with certain sensitivities in terms of… ▽ More

    Submitted 14 October, 2019; v1 submitted 30 September, 2019; originally announced October 2019.

    Comments: Talk presented at the 2019 Meeting of the Division of Particles and Fields of the American Physical Society (DPF2019), July 29 - August 2, 2019, Northeastern University, Boston, C1907293

  15. arXiv:1902.06922  [pdf, other

    cond-mat.quant-gas physics.atom-ph

    Kibble-Zurek universality in a strongly interacting Fermi superfluid

    Authors: Bumsuk Ko, Jee Woo Park, Y. Shin

    Abstract: Near a continuous phase transition, systems with different microscopic origins display universal dynamics if their underlying symmetries are compatible. In a thermally quenched system, the Kibble-Zurek mechanism for the creation of topological defects unveils this universality through a characteristic power-law exponent, which captures the dependence of the defect density on the quench rate. Here,… ▽ More

    Submitted 19 February, 2019; originally announced February 2019.

    Journal ref: Nat. Phys. (2019)

  16. arXiv:1711.02800  [pdf, other

    physics.ins-det hep-ex

    Three dimensional fast tracker for central drift chamber based level 1 trigger system in the Belle II experiment

    Authors: E. Won, J. B. Kim, B. R. Ko

    Abstract: The Belle II detector at the SuperKEKB accelerator has a level 1 trigger implemented in field-programmable gate arrays. Due to the high luminosity of the beam, a trigger that effectively rejects beam induced background is required. A three dimensional tracking algorithm for the level 1 trigger that uses the Belle II central drift chamber detector response is being developed to reduce the recorded… ▽ More

    Submitted 7 November, 2017; originally announced November 2017.

    Comments: 4 pages, 7 figures

  17. arXiv:1704.07957  [pdf, ps, other

    hep-ex physics.ins-det

    First axion dark matter search with toroidal geometry

    Authors: J. Choi, H. Themann, M. J. Lee, B. R. Ko, Y. K. Semertzidis

    Abstract: We firstly report an axion haloscope search with toroidal geometry. In this pioneering search, we exclude the axion-photon coupling $g_{aγγ}$ down to about $5\times10^{-8}$ GeV$^{-1}$ over the axion mass range from 24.7 to 29.1 $μ$eV at a 95\% confidence level. The prospects for axion dark matter searches with larger scale toroidal geometry are also considered.

    Submitted 5 September, 2017; v1 submitted 25 April, 2017; originally announced April 2017.

    Comments: 5 pages, 5 figures, 1 table and to appear in PRD-RC

    Journal ref: Phys. Rev. D 96, 061102 (2017)

  18. arXiv:1610.06635  [pdf, other

    cond-mat.quant-gas physics.flu-dyn

    Observation of vortex-antivortex pairing in decaying 2D turbulence of a superfluid gas

    Authors: Sang Won Seo, Bumsuk Ko, Joon Hyun Kim, Yong-il Shin

    Abstract: In a two-dimensional (2D) classical fluid, a large-scale flow structure emerges out of turbulence, which is known as the inverse energy cascade where energy flows from small to large length scales. An interesting question is whether this phenomenon can occur in a superfluid, which is inviscid and irrotational by nature. Atomic Bose-Einstein condensates (BECs) of highly oblate geometry provide an e… ▽ More

    Submitted 10 May, 2017; v1 submitted 20 October, 2016; originally announced October 2016.

    Comments: 8 pages, 8 figures

    Journal ref: Scientific Reports 7, 4587 (2017)

  19. arXiv:1609.03752  [pdf, ps, other

    physics.ins-det hep-ex

    Axion Haloscopes with Toroidal Geometry at CAPP/IBS

    Authors: B. R. Ko

    Abstract: The present state of the art axion haloscope employs a cylindrical resonant cavity in a solenoidal field. We, the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in Korea, are also pursuing halo axion discovery using this cylindrical geometry. However, the presence of end caps of cavities increases challenges as we explore higher frequency regions fo… ▽ More

    Submitted 13 September, 2016; originally announced September 2016.

    Comments: Proceedings of the 12th Patras Workshop on Axions, WIMPs, and WISPs

  20. arXiv:1011.0352  [pdf

    physics.ins-det hep-ex

    Belle II Technical Design Report

    Authors: T. Abe, I. Adachi, K. Adamczyk, S. Ahn, H. Aihara, K. Akai, M. Aloi, L. Andricek, K. Aoki, Y. Arai, A. Arefiev, K. Arinstein, Y. Arita, D. M. Asner, V. Aulchenko, T. Aushev, T. Aziz, A. M. Bakich, V. Balagura, Y. Ban, E. Barberio, T. Barvich, K. Belous, T. Bergauer, V. Bhardwaj , et al. (387 additional authors not shown)

    Abstract: The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr… ▽ More

    Submitted 1 November, 2010; originally announced November 2010.

    Comments: Edited by: Z. Doležal and S. Uno

    Report number: KEK Report 2010-1