-
Spin Physics at COSY (2021-2024 and beyond) -- Pathfinder investigations toward an EDM storage ring and Spin-for-FAIR
Authors:
R. Gebel,
V. Hejny,
A. Kacharava,
A. Lehrach,
P. Lenisa,
A. Nass,
J. Pretz,
F. Rathmann,
H. Ströher,
I. Keshelashvili,
E. J. Stephenson,
A. Wrońska Y. Filatov,
A. Kondratenko,
M. Kondratenko,
N. Nikolaev,
A. Melnikov,
Y. Senichev,
A. Aksentyev,
A. Butenko,
E. Syresin,
A. Saleev,
V. Shmakova,
S. Karanth,
B. Breitkreutz,
N. Shurkhno
, et al. (2 additional authors not shown)
Abstract:
The unique global feature of COSY is its ability to accelerate, store and manipulate polarized proton and deuteron beams. In the recent past, these beams have been used primarily for precision measurements, in particular in connection with the study of charged particle EDMs (Electric Dipole Moment) in storage rings. The role of COSY as a R&D facility and for initial (static and oscillating) EDM me…
▽ More
The unique global feature of COSY is its ability to accelerate, store and manipulate polarized proton and deuteron beams. In the recent past, these beams have been used primarily for precision measurements, in particular in connection with the study of charged particle EDMs (Electric Dipole Moment) in storage rings. The role of COSY as a R&D facility and for initial (static and oscillating) EDM measurements can hardly be overestimated. Unfortunately, as a consequence of the strategic decisions of Forschungszentrum Jülich and the subsequent "TransFAIR" agreement between FZJ and GSI Darmstadt, it is currently planned to stop the operation of COSY by the end of 2024. The various groups working with polarized beams at COSY felt it important to collect information on essential measurements to be performed until the termination of machine operation. These experiments, briefly described in this document along with an estimate of the beam time required, serve as pathfinder investigations toward an EDM storage ring and Spin for FAIR.
△ Less
Submitted 31 August, 2021;
originally announced August 2021.
-
Conceptual design of the Spin Physics Detector
Authors:
V. M. Abazov,
V. Abramov,
L. G. Afanasyev,
R. R. Akhunzyanov,
A. V. Akindinov,
N. Akopov,
I. G. Alekseev,
A. M. Aleshko,
V. Yu. Alexakhin,
G. D. Alexeev,
M. Alexeev,
A. Amoroso,
I. V. Anikin,
V. F. Andreev,
V. A. Anosov,
A. B. Arbuzov,
N. I. Azorskiy,
A. A. Baldin,
V. V. Balandina,
E. G. Baldina,
M. Yu. Barabanov,
S. G. Barsov,
V. A. Baskov,
A. N. Beloborodov,
I. N. Belov
, et al. (270 additional authors not shown)
Abstract:
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarize…
▽ More
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarized beams at JINR.
The main objective of the proposed experiment is the comprehensive study of the unpolarized and polarized gluon content of the nucleon. Spin measurements at the Spin Physics Detector at the NICA collider have bright perspectives to make a unique contribution and challenge our understanding of the spin structure of the nucleon. In this document the Conceptual Design of the Spin Physics Detector is presented.
△ Less
Submitted 2 February, 2022; v1 submitted 31 January, 2021;
originally announced February 2021.
-
Transparent Spin Method for Spin Control of Hadron Beams in Colliders
Authors:
Yu. N. Filatov,
A. M. Kondratenko,
M. A. Kondratenko,
Ya. S. Derbenev,
V. S. Morozov
Abstract:
We present a concept for control of the ion polarization, called a transparent spin method. The spin transparency is achieved by designing such a synchrotron structure that the net spin rotation angle in one particle turn is zero. The polarization direction of any ions including deuterons can be efficiently controlled using weak quasi-static fields. These fields allow for dynamic adjustment of the…
▽ More
We present a concept for control of the ion polarization, called a transparent spin method. The spin transparency is achieved by designing such a synchrotron structure that the net spin rotation angle in one particle turn is zero. The polarization direction of any ions including deuterons can be efficiently controlled using weak quasi-static fields. These fields allow for dynamic adjustment of the polarization direction during an experiment. The main features of the Transparent Spin method are illustrated in a figure-8 collider. The results are relevant to the Electron-Ion Collider considered in the US, the ion-ion collider NICA constructed in Russia, and a polarized Electron-ion collider planned in China.
△ Less
Submitted 12 May, 2020; v1 submitted 25 March, 2020;
originally announced March 2020.
-
First results on the measurements of the proton beam polarization at internal target at Nuclotron
Authors:
V. P. Ladygin,
Yu. V. Gurchin,
A. Yu. Isupov,
M. Janek,
A. N. Khrenov,
P. K. Kurilkin,
A. N. Livanov,
S. M. Piyadin,
S. G. Reznikov,
Ya. T. Skhomenko,
A. A. Terekhin,
A. V. Tishevsky,
A. V. Averyanov,
S. N. Bazylev,
A. S. Belov,
A. V. Butenko,
E. V. Chernykh,
Yu. N. Filatov,
V. V. Fimushkin,
D. O. Krivenkov,
A. M. Kondratenko,
M. A. Kondratenko,
A. D. Kovalenko,
I. V. Slepnev,
V. M. Slepnev
, et al. (4 additional authors not shown)
Abstract:
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scatteri…
▽ More
The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scattering and DSS setup at internal target. The obtained value of the vertical polarization of ~35 % is consistent with the calculations taking into account the current magnetic optics of the Nuclotron injection line.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Ion Polarization Scheme for MEIC
Authors:
A. M. Kondratenko,
M. A. Kondratenko,
Yu. N. Filatov,
Ya. S. Derbenev,
F. Lin,
V. S. Morozov,
Y. Zhang
Abstract:
The choice of a figure 8 shape for the booster and collider rings of MEIC opens wide possibilities for preservation of the ion polarization during beam acceleration as well as for control of the polarization at the collider's interaction points. As in the case of accelerators with Siberian snakes, the spin tune is energy independent but is equal to zero instead of one half. The figure-8 topology e…
▽ More
The choice of a figure 8 shape for the booster and collider rings of MEIC opens wide possibilities for preservation of the ion polarization during beam acceleration as well as for control of the polarization at the collider's interaction points. As in the case of accelerators with Siberian snakes, the spin tune is energy independent but is equal to zero instead of one half. The figure-8 topology eliminates the effect of arcs on the spin motion. There appears a unique opportunity to control the polarization of any particle species including deuterons, using longitudinal fields of small integrated strength (weak solenoids). Contrary to existing schemes, using weak solenoids in figure-8 colliders, one can control the polarization at the interaction points without essentially any effect on the beam's orbital characteristics. A universal scheme for control of the polarization using weak solenoids provides an elegant solution to the problem of ion acceleration completely eliminating resonant beam depolarization. It allows one to easily adjust the polarization in any direction at any orbital location, which becomes necessary when transferring the beam from one ring into another or when measuring the polarization by polarimeters. It also allows for an easy manipulation of the spin direction at an interaction point during an experiment. The latter feature allows one to set up a spin-flip** system with a spin reversal time of less than a second. By compensating the coherent part of the zero-integer spin resonance strength, which arises due to errors in alignment of the magnetic element of the lattice, one can reduce the field integrals of the control solenoids by a few orders of magnitude.
△ Less
Submitted 19 April, 2016;
originally announced April 2016.
-
MEIC Design Summary
Authors:
S. Abeyratne,
D. Barber,
A. Bogacz,
P. Brindza,
Y. Cai,
A. Camsonne,
A. Castilla,
P. Chevtsov,
E. Daly,
Y. S. Derbenev,
D. Douglas,
V. Dudnikov,
R. Ent,
B. Erdelyi,
Y. Filatov,
D. Gaskell,
J. Grames,
J. Guo,
L. Harwood,
A. Hutton,
C. Hyde,
K. Jordan,
A. Kimber,
G. A. Krafft,
A. Kondratenko
, et al. (30 additional authors not shown)
Abstract:
This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current infor…
▽ More
This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current information.
△ Less
Submitted 29 April, 2015;
originally announced April 2015.
-
One 4-Twist Helix Snake to Maintain Polarization in 8-120 GeV Proton Rings
Authors:
F. Antoulinakis,
E. A. Ljungman,
A. Tai,
C. A. Aidala,
E. D. Courant,
A. D. Krisch,
W. Lorenzon,
P. D. Myers,
R. S. Raymond,
D. W. Sivers,
M. A. Leonova,
Y. S. Derbenev,
V. S. Morozov,
A. M. Kondratenko
Abstract:
Solenoid Siberian snakes have successfully maintained polarization in particle rings below 1 GeV, but never in multi-GeV rings because the Lorentz contraction of a solenoid's integral B dl would require impractically long high-field solenoids. High energy rings, such as Brookhaven's 255 GeV Relativistic Heavy Ion Collider (RHIC), use only odd multiples of pairs of transverse B-field Siberian snake…
▽ More
Solenoid Siberian snakes have successfully maintained polarization in particle rings below 1 GeV, but never in multi-GeV rings because the Lorentz contraction of a solenoid's integral B dl would require impractically long high-field solenoids. High energy rings, such as Brookhaven's 255 GeV Relativistic Heavy Ion Collider (RHIC), use only odd multiples of pairs of transverse B-field Siberian snakes directly opposite each other. When it became impractical to use a pair of Siberian Snakes in Fermilab's 120 GeV Main Injector, we searched for a new type of single Siberian snake, which should overcome all depolarizing resonances in the 8.9 - 120 GeV range. We found that one snake made of one 4-twist helix and 2 short dipoles could maintain the polarization. This snake design might also be used at other rings, such as Japan's 30 GeV J-PARC, the 12 - 24 GeV NICA proton-deuteron collider at JINR-Dubna, and perhaps RHIC's injector, the 25 GeV AGS.
△ Less
Submitted 4 September, 2013;
originally announced September 2013.
-
Science Requirements and Conceptual Design for a Polarized Medium Energy Electron-Ion Collider at Jefferson Lab
Authors:
S. Abeyratne,
A. Accardi,
S. Ahmed,
D. Barber,
J. Bisognano,
A. Bogacz,
A. Castilla,
P. Chevtsov,
S. Corneliussen,
W. Deconinck,
P. Degtiarenko,
J. Delayen,
Ya. Derbenev,
S. DeSilva,
D. Douglas,
V. Dudnikov,
R. Ent,
B. Erdelyi,
P. Evtushenko,
Yu. Filatov,
D. Gaskell,
R. Geng,
V. Guzey,
T. Horn,
A. Hutton
, et al. (33 additional authors not shown)
Abstract:
This report presents a brief summary of the science opportunities and program of a polarized medium energy electron-ion collider at Jefferson Lab and a comprehensive description of the conceptual design of such a collider based on the CEBAF electron accelerator facility.
This report presents a brief summary of the science opportunities and program of a polarized medium energy electron-ion collider at Jefferson Lab and a comprehensive description of the conceptual design of such a collider based on the CEBAF electron accelerator facility.
△ Less
Submitted 5 September, 2012; v1 submitted 4 September, 2012;
originally announced September 2012.
-
Updated Report Acceleration of Polarized Protons to 120-150 GeV/c at Fermilab
Authors:
E. D. Courant,
A. D. Krisch,
M. A. Leonova,
A. M. T. Lin,
J. Liu,
W. Lorenzon,
D. A. Nees,
R. S. Raymond,
D. W. Sivers,
V. K. Wong,
I. Kourbanis,
Ya. S. Derbenev,
V. S. Morozov,
D. G. Crabb,
P. E. Reimer,
J. R. O'Fallon,
G. Fidecaro,
M. Fidecaro,
F. Hinterberger,
S. M. Troshin,
M. N. Ukhanov,
A. M. Kondratenko,
W. T. H. van Oers
Abstract:
The SPIN@FERMI collaboration has updated its 1991-95 Reports on the acceleration of polarized protons in Fermilab's Main Injector, which was commissioned by Fermilab. This Updated Report summarizes some updated Physics Goals for a 120-150 GeV/c polarized proton beam. It also contains an updated discussion of the Modifications and Hardware needed for a polarized beam in the Main Injector, along wit…
▽ More
The SPIN@FERMI collaboration has updated its 1991-95 Reports on the acceleration of polarized protons in Fermilab's Main Injector, which was commissioned by Fermilab. This Updated Report summarizes some updated Physics Goals for a 120-150 GeV/c polarized proton beam. It also contains an updated discussion of the Modifications and Hardware needed for a polarized beam in the Main Injector, along with an updated Schedule and Budget.
△ Less
Submitted 12 October, 2011;
originally announced October 2011.
-
Wide spin resonance with an rf-bunched proton beam
Authors:
V. S. Morozov,
A. W. Chao,
A. D. Krisch,
M. A. Leonova,
J. Liu,
R. S. Raymond,
D. W. Sivers,
V. K. Wong,
A. M. Kondratenko
Abstract:
We recently used an rf solenoid to study the widths of rf spin resonances with both unbunched and bunched beams of 2.1 GeV_c polarized protons stored in the COSY synchrotron. A map, with unbunched beam at different fixed rf-solenoid frequencies, showed a very shallow possible depolarization dip at the resonance. Next we made frequency sweeps of 400Hz, centered at similar frequencies, which great…
▽ More
We recently used an rf solenoid to study the widths of rf spin resonances with both unbunched and bunched beams of 2.1 GeV_c polarized protons stored in the COSY synchrotron. A map, with unbunched beam at different fixed rf-solenoid frequencies, showed a very shallow possible depolarization dip at the resonance. Next we made frequency sweeps of 400Hz, centered at similar frequencies, which greatly enhanced the dip. But, with a bunched proton beam, both the fixed-frequency and frequency-sweep techniques produced similar maps, and both bunched maps showed full beam depolarization over a wide region. Moreover, both were more than twice as wide as the unbunched dip. This widening of the proton resonance due to bunching is exactly opposite to the recently observed narrowing of deuteron resonances due to bunching.
△ Less
Submitted 9 January, 2010;
originally announced January 2010.
-
Spin resonance strengths due to rf solenoids and dipoles for stored deuteron beams
Authors:
M. A. Leonova,
A. W. Chao,
E. D. Courant,
A. D. Krisch,
V. S. Morozov,
R. S. Raymond,
D. W. Sivers,
J. M. Williams,
V. K. Wong,
A. Garishvili,
R. Gebel,
A. Lehrach,
B. Lorentz,
R. Maier,
D. Prasuhn,
H. Stockhorst,
D. Welsch,
F. Hinterberger,
K. Ulbrich,
Ya. S. Derbenev,
A. M. Kondratenko,
Y. F. Orlov,
E. J. Stephenson,
N. P. M. Brantjes,
C. J. G. Onderwater
, et al. (1 additional authors not shown)
Abstract:
This submission was withdrawn because of an unresolved dispute between the authors [arXiv admin 2009-4-13].
This submission was withdrawn because of an unresolved dispute between the authors [arXiv admin 2009-4-13].
△ Less
Submitted 13 April, 2009; v1 submitted 16 January, 2009;
originally announced January 2009.