-
Plasma screening in mid-charged ions observed by K-shell line emission
Authors:
M. Šmıd,
O. Humphries,
C. Baehtz,
E. Brambrink,
T. Burian,
M. S. Cho,
T. E. Cowan,
L. Gaus,
V. Hájková,
L. Juha,
Z. Konopkova,
H. P. Le,
M. Makita,
X. Pan,
T. Preston,
A. Schropp,
H. A. Scott,
R. Štefanıková,
J. Vorberger,
W. Wang,
U. Zastrau,
K. Falk
Abstract:
Dense plasma environment affects the electronic structure of ions via variations of the microscopic electrical fields, also known as plasma screening. This effect can be either estimated by simplified analytical models, or by computationally expensive and to date unverified numerical calculations. We have experimentally quantified plasma screening from the energy shifts of the bound-bound transiti…
▽ More
Dense plasma environment affects the electronic structure of ions via variations of the microscopic electrical fields, also known as plasma screening. This effect can be either estimated by simplified analytical models, or by computationally expensive and to date unverified numerical calculations. We have experimentally quantified plasma screening from the energy shifts of the bound-bound transitions in matter driven by the x-ray free electron laser (XFEL). This was enabled by identification of detailed electronic configurations of the observed Kα, K\b{eta} and Kγ lines. This work paves the way for improving plasma screening models including connected effects like ionization potential depression and continuum lowering, which will advance the understanding of atomic physics in Warm Dense Matter regime.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
Effects of Mosaic Crystal Instrument Functions on X-ray Thomson Scattering Diagnostics
Authors:
Thomas Gawne,
Hannah Bellenbaum,
Luke B. Fletcher,
Karen Appel,
Carsten Baehtz,
Victorien Bouffetier,
Erik Brambrink,
Danielle Brown,
Attila Cangi,
Adrien Descamps,
Sebastian Göde,
Nicholas J. Hartley,
Marie-Luise Herbert,
Philipp Hesselbach,
Hauke Höppner,
Oliver S. Humphries,
Zuzana Konôpková,
Alejandro Laso,
Björn Lindqvist,
Julian Lütgert,
Michael J. MacDonald,
Mikako Makita,
Willow Martin,
Mikhail Mishchenko,
Zhandos A. Moldabekov
, et al. (14 additional authors not shown)
Abstract:
Mosaic crystals, with their high integrated reflectivities, are widely-employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the sp…
▽ More
Mosaic crystals, with their high integrated reflectivities, are widely-employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of mosaic crystals and how the broadening varies across the spectrometer. Notably, we find a strong asymmetry in the shape of the IF towards higher energies. As an example, we consider the effect on the inferred temperature, and find that it can be overestimated if an approximate symmetric IF is used. We therefore expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modelling and model-free approaches.
△ Less
Submitted 5 June, 2024;
originally announced June 2024.
-
Ultrahigh Resolution X-ray Thomson Scattering Measurements at the European XFEL
Authors:
Thomas Gawne,
Zhandos A. Moldabekov,
Oliver S. Humphries,
Karen Appel,
Carsten Bähtz,
Victorien Bouffetier,
Erik Brambrink,
Attila Cangi,
Sebastian Göde,
Zuzana Konôpková,
Mikako Makita,
Mikhail Mishchenko,
Motoaki Nakatsutsumi,
Kushal Ramakrishna,
Lisa Randolph,
Sebastian Schwalbe,
Jan Vorberger,
Lennart Wollenweber,
Ulf Zastrau,
Tobias Dornheim,
Thomas R. Preston
Abstract:
Using a novel ultrahigh resolution ($ΔE \sim 0.1\,$eV) setup to measure electronic features in x-ray Thomson scattering (XRTS) experiments at the European XFEL in Germany, we have studied the collective plasmon excitation in aluminium at ambient conditions, which we can measure very accurately even at low momentum transfers. As a result, we can resolve previously reported discrepancies between ab…
▽ More
Using a novel ultrahigh resolution ($ΔE \sim 0.1\,$eV) setup to measure electronic features in x-ray Thomson scattering (XRTS) experiments at the European XFEL in Germany, we have studied the collective plasmon excitation in aluminium at ambient conditions, which we can measure very accurately even at low momentum transfers. As a result, we can resolve previously reported discrepancies between ab initio time-dependent density functional theory simulations and experimental observations. The demonstrated capability for high-resolution XRTS measurements will be a game changer for the diagnosis of experiments with matter under extreme densities, temperatures, and pressures, and unlock the full potential of state-of-the-art x-ray free electron laser (XFEL) facilities to study planetary interior conditions, to understand inertial confinement fusion applications, and for material science and discovery.
△ Less
Submitted 16 May, 2024; v1 submitted 5 March, 2024;
originally announced March 2024.
-
Thermomechanical response of thickly tamped targets and diamond anvil cells under pulsed hard x-ray irradiation
Authors:
J. Meza-Galvez,
N. Gomez-Perez,
A. Marshall,
A. L. Coleman,
K. Appel,
H. P. Liermann,
M. I. McMahon,
Z. Konopkova,
R. S. McWilliams
Abstract:
In the laboratory study of extreme conditions of temperature and density, the exposure of matter to high intensity radiation sources has been of central importance. Here we interrogate the performance of multi-layered targets in experiments involving high intensity, hard x-ray irradiation, motivated by the advent of extremely high brightness hard x-ray sources, such as free electron lasers and 4th…
▽ More
In the laboratory study of extreme conditions of temperature and density, the exposure of matter to high intensity radiation sources has been of central importance. Here we interrogate the performance of multi-layered targets in experiments involving high intensity, hard x-ray irradiation, motivated by the advent of extremely high brightness hard x-ray sources, such as free electron lasers and 4th-generation synchrotron facilities. Intense hard x-ray beams can deliver significant energy in targets having thick x-ray transparent layers (tampers) around samples of interest, for the study of novel states of matter and materials' dynamics. Heated-state lifetimes in such targets can approach the microsecond level, regardless of radiation pulse duration, enabling the exploration of conditions of local thermal and thermodynamic equilibrium at extreme temperature in solid density matter. The thermal and mechanical response of such thick layered targets following x-ray heating, including hydrodynamic relaxation and heat flow on picosecond to millisecond timescales, is modelled using radiation hydrocode simulation, finite element analysis, and thermodynamic calculations. Assessing the potential for target survival over one or more exposures, and resistance to damage arising from heating and resulting mechanical stresses, this study doubles as an investigation into the performance of diamond-anvil high pressure cells under high x-ray fluences. Long used in conjunction with synchrotron x-ray radiation and high power optical lasers, the strong confinement afforded by such cells suggests novel applications at emerging high intensity x-ray facilities and new routes to studying thermodynamic equilibrium states of warm, very dense matter.
△ Less
Submitted 4 December, 2019; v1 submitted 28 June, 2018;
originally announced June 2018.
-
Pressure, stress, and strain distribution in the double-stage diamond anvil cell
Authors:
Sergey S. Lobanov,
Vitali B. Prakapenka,
Clemens Prescher,
Zuzana Konôpkova,
Hanns-Peter Liermann,
Katherine Crispin,
Chi Zhang,
Alexander F. Goncharov
Abstract:
Double stage diamond anvil cells (DAC) of two designs have been assembled and tested. We used a standard symmetric DAC as a primary stage and CVD microanvils machined by a focused ion beam - as a second. We evaluated pressure, stress, and strain distributions in Au and Fe-Au samples as well as in secondary anvils using synchrotron x-ray diffraction with a micro-focused beam. A maximum pressure of…
▽ More
Double stage diamond anvil cells (DAC) of two designs have been assembled and tested. We used a standard symmetric DAC as a primary stage and CVD microanvils machined by a focused ion beam - as a second. We evaluated pressure, stress, and strain distributions in Au and Fe-Au samples as well as in secondary anvils using synchrotron x-ray diffraction with a micro-focused beam. A maximum pressure of 240 GPa was reached independent of the first stage anvil culet size. We found that the stress field generated by the second stage anvils is typical of conventional DAC experiments. The maximum pressures reached are limited by strains develo** in the secondary anvil and by cup** of the first stage diamond anvil in the presented experimental designs. Also, our experiments show that pressures of several megabars may be reached without sacrificing the first stage diamond anvils.
△ Less
Submitted 3 April, 2015;
originally announced April 2015.