-
Cross-Correlated Force Measurement for Thermal Noise Reduction in Torsion Pendulum
Authors:
Yusuke Okuma,
Kiwamu Izumi,
Kentaro Komori,
Masaki Ando
Abstract:
The torsion pendulum is a prevailing instrument for measuring small forces acting on a solid body or those between solid bodies. While it offers powerful advantages, the measurement precision suffers from thermal noises of the suspending wires giving rise to stochastic torque noises. This letter proposes a new scheme to reduce the effect of such noise by employing a double torsion pendulum and cro…
▽ More
The torsion pendulum is a prevailing instrument for measuring small forces acting on a solid body or those between solid bodies. While it offers powerful advantages, the measurement precision suffers from thermal noises of the suspending wires giving rise to stochastic torque noises. This letter proposes a new scheme to reduce the effect of such noise by employing a double torsion pendulum and cross-correlation technique based on the theoretical analysis that the thermal torque noise appears at each end of the suspending wire differentially. Cross-correlating two synthesized data streams which are composed of the rotation angles of two torsion stages, it yields the power spectral density estimate of external forces acting on the lower stage with the reduced effect from the thermal torque noises. As an example use case, we discuss the application to the study on the coupling strength of ultra light dark matter to standard model particles. Our evaluation indicates that the upper limit may be improved by an order of magnitude than the previous experiments at 2 mHz, which corresponds to about $8\times10^{-18}$ eV.
△ Less
Submitted 30 March, 2024;
originally announced April 2024.
-
Kerr-Enhanced Optical Spring
Authors:
Sotatsu Otabe,
Wataru Usukura,
Kaido Suzuki,
Kentaro Komori,
Yuta Michimura,
Ken-ichi Harada,
Kentaro Somiya
Abstract:
We propose and experimentally demonstrate the generation of enhanced optical springs using the optical Kerr effect. A nonlinear optical crystal is inserted into a Fabry-Perot cavity with a movable mirror, and a chain of second-order nonlinear optical effects in the phase-mismatched condition induces the Kerr effect. The optical spring constant is enhanced by a factor of $1.6\pm0.1$ over linear the…
▽ More
We propose and experimentally demonstrate the generation of enhanced optical springs using the optical Kerr effect. A nonlinear optical crystal is inserted into a Fabry-Perot cavity with a movable mirror, and a chain of second-order nonlinear optical effects in the phase-mismatched condition induces the Kerr effect. The optical spring constant is enhanced by a factor of $1.6\pm0.1$ over linear theory. To our knowledge, this is the first realization of optomechanical coupling enhancement using a nonlinear optical effect, which has been theoretically investigated to overcome the performance limitations of linear optomechanical systems. The tunable nonlinearity of demonstrated system has a wide range of potential applications, from observing gravitational waves emitted by binary neutron star post-merger remnants to cooling macroscopic oscillators to their quantum ground state.
△ Less
Submitted 4 April, 2024; v1 submitted 28 October, 2023;
originally announced October 2023.
-
Optimization of quantum noise in space gravitational-wave antenna DECIGO with optical-spring quantum locking considering mixture of vacuum fluctuations in homodyne detection
Authors:
Kenji Tsuji,
Tomohiro Ishikawa,
Kentaro Komori,
Koji Nagano,
Yutaro Enomoto,
Yuta Michimura,
Kurumi Umemura,
Ryuma Shimizu,
Bin Wu,
Shoki Iwaguchi,
Yuki Kawasaki,
Akira Furusawa,
Seiji Kawamura
Abstract:
Quantum locking using optical spring and homodyne detection has been devised to reduce quantum noise that limits the sensitivity of DECIGO, a space-based gravitational wave antenna in the frequency band around 0.1 Hz for detection of primordial gravitational waves. The reduction in the upper limit of energy density $Ω_{\mathrm{GW}}$ from $2{\times}10^{-15}$ to $1{\times}10^{-16}$, as inferred from…
▽ More
Quantum locking using optical spring and homodyne detection has been devised to reduce quantum noise that limits the sensitivity of DECIGO, a space-based gravitational wave antenna in the frequency band around 0.1 Hz for detection of primordial gravitational waves. The reduction in the upper limit of energy density $Ω_{\mathrm{GW}}$ from $2{\times}10^{-15}$ to $1{\times}10^{-16}$, as inferred from recent observations, necessitates improved sensitivity in DECIGO to meet its primary science goals. To accurately evaluate the effectiveness of this method, this paper considers a detection mechanism that takes into account the influence of vacuum fluctuations on homodyne detection. In addition, an advanced signal processing method is devised to efficiently utilize signals from each photodetector, and design parameters for this configuration are optimized for the quantum noise. Our results show that this method is effective in reducing quantum noise, despite the detrimental impact of vacuum fluctuations on its sensitivity.
△ Less
Submitted 24 October, 2023;
originally announced October 2023.
-
Radiation Tolerance of Low-Noise Photoreceivers for the LISA Space Mission
Authors:
P. Colcombet,
N. Dinu-Jaeger,
C. Inguimbert,
T. Nuns,
S. Bruhier,
N. Christensen,
P. Hofverberg,
N. van Bakel,
M. van Beuzekom,
T. Mistry,
G. Visser,
D. Pascucci,
K. Izumi,
K. Komori,
G. Heinzel,
G. Fernández Barranco,
J. J. M. in t Zand,
P. Laubert,
M. Frericks
Abstract:
This study investigates the effects of space environmental radiation on the performance of InGaAs Quadrant Photodiodes (QPDs) and assesses their suitability for the Laser Interferometer Space Antenna (LISA) mission. QPDs of 1.0, 1.5 and 2.0 mm have been irradiated with 20 and 60 MeV protons, 0.5 and 1 MeV electrons, and Co$^{60}$ gamma. An exposure corresponding to a displacement damage equivalent…
▽ More
This study investigates the effects of space environmental radiation on the performance of InGaAs Quadrant Photodiodes (QPDs) and assesses their suitability for the Laser Interferometer Space Antenna (LISA) mission. QPDs of 1.0, 1.5 and 2.0 mm have been irradiated with 20 and 60 MeV protons, 0.5 and 1 MeV electrons, and Co$^{60}$ gamma. An exposure corresponding to a displacement damage equivalent fluence of $1.0 \times 10^{+12}$ p/cm$^2$ for 20 and 60 MeV protons and a total ionizing dose of 237 krad were applied, surpassing the anticipated radiation levels for the LISA mission by a factor of approximately five. Experiments were conducted to measure changes in QPD dark current, capacitance, and responsivity. The QPDs are integrated with a low-noise DC-coupled transimpedance amplifier to form the Photoreceiver (QPR). QPR noise and performance in an interferometric system like LISA were also measured. Although radiation impacted their dark current and responsivity, almost all QPDs met LISA's validation criteria and did not demonstrate any critical failure. These findings prove that the tested QPDs are promising candidates for LISA and other space-based missions.
△ Less
Submitted 15 October, 2023;
originally announced October 2023.
-
Photothermal effect in macroscopic optomechanical systems with an intracavity nonlinear optical crystal
Authors:
Sotatsu Otabe,
Kentaro Komori,
Ken-ichi Harada,
Kaido Suzuki,
Yuta Michimura,
Kentaro Somiya
Abstract:
Intracavity squeezing is a promising technique that may improve the sensitivity of gravitational wave detectors and cool optomechanical oscillators to the ground state. However, the photothermal effect may modify the occurrence of optomechanical coupling due to the presence of a nonlinear optical crystal in an optical cavity. We propose a novel method to predict the influence of the photothermal e…
▽ More
Intracavity squeezing is a promising technique that may improve the sensitivity of gravitational wave detectors and cool optomechanical oscillators to the ground state. However, the photothermal effect may modify the occurrence of optomechanical coupling due to the presence of a nonlinear optical crystal in an optical cavity. We propose a novel method to predict the influence of the photothermal effect by measuring the susceptibility of the optomechanical oscillator and identifying the net optical spring constant and photothermal absorption rate. Using this method, we succeeded in precisely estimating parameters related to even minor photothermal effects, which could not be measured using a previously developed method.
△ Less
Submitted 4 November, 2022;
originally announced November 2022.
-
Input optics systems of the KAGRA detector during O3GK
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
Z. Cao,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
C-I. Chiang,
H. Chu,
Y-K. Chu,
S. Eguchi
, et al. (228 additional authors not shown)
Abstract:
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensit…
▽ More
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.
△ Less
Submitted 12 October, 2022;
originally announced October 2022.
-
Quantum theory of feedback cooling of an anelastic macro-mechanical oscillator
Authors:
Kentaro Komori,
Dominika Ďurovčíková,
Vivishek Sudhir
Abstract:
Conventional techniques for laser cooling, by coherent scattering off of internal states or through an optical cavity mode, have so far proved inefficient on mechanical oscillators heavier than a few nanograms. That is because larger oscillators vibrate at frequencies much too small compared to the scattering rates achievable by their coupling to auxiliary modes. Decoherence mechanisms typically o…
▽ More
Conventional techniques for laser cooling, by coherent scattering off of internal states or through an optical cavity mode, have so far proved inefficient on mechanical oscillators heavier than a few nanograms. That is because larger oscillators vibrate at frequencies much too small compared to the scattering rates achievable by their coupling to auxiliary modes. Decoherence mechanisms typically observed in heavy low frequency elastically suspended oscillators also differ markedly from what is assumed in conventional treatments of laser cooling. We show that for a low-frequency anelastic oscillator forming the mechanically compliant end-mirror of a cavity, detuned optical readout, together with measurement-based feedback to stiffen and dampen it, can harness ponderomotively generated quantum correlations, to realize efficient cooling to the motional ground state. This will pave the way for experiments that call for milligram-scale mechanical oscillators prepared in pure motional states, for example, for tests of gravity's effect on massive quantum systems.
△ Less
Submitted 3 November, 2021;
originally announced November 2021.
-
Improving force sensitivity by amplitude measurement of light reflected from a detuned optomechanical cavity
Authors:
Kentaro Komori,
Takuya Kawasaki,
Sotatsu Otabe,
Yutaro Enomoto,
Yuta Michimura,
Masaki Ando
Abstract:
The measurement of weak continuous forces exerted on a mechanical oscillator is a fundamental problem in various physical experiments. It is fundamentally impeded by quantum back-action from the meter used to sense the displacement of the oscillator. In the context of interferometric displacement measurements, we here propose and demonstrate the working principle of a scheme for coherent back-acti…
▽ More
The measurement of weak continuous forces exerted on a mechanical oscillator is a fundamental problem in various physical experiments. It is fundamentally impeded by quantum back-action from the meter used to sense the displacement of the oscillator. In the context of interferometric displacement measurements, we here propose and demonstrate the working principle of a scheme for coherent back-action cancellation. By measuring the amplitude quadrature of the light reflected from a detuned optomechanical cavity inside which a stiff optical spring is generated, back-action can be cancelled in a narrow band of frequencies. This method provides a simple way to improve the sensitivity in experiments limited by quantum back-action without injection of squeezed light or stable homodyne readout.
△ Less
Submitted 21 May, 2021;
originally announced May 2021.
-
Demonstration of an amplitude filter cavity at gravitational-wave frequencies
Authors:
Kentaro Komori,
Dhruva Ganapathy,
Chris Whittle,
Lee McCuller,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Quantum vacuum fluctuations fundamentally limit the precision of optical measurements, such as those in gravitational-wave detectors. Injection of conventional squeezed vacuum can be used to reduce quantum noise in the readout quadrature, but this reduction is at the cost of increasing noise in the orthogonal quadrature. For detectors near the limits imposed by quantum radiation pressure noise (QR…
▽ More
Quantum vacuum fluctuations fundamentally limit the precision of optical measurements, such as those in gravitational-wave detectors. Injection of conventional squeezed vacuum can be used to reduce quantum noise in the readout quadrature, but this reduction is at the cost of increasing noise in the orthogonal quadrature. For detectors near the limits imposed by quantum radiation pressure noise (QRPN), both quadratures impact the measurement, and the benefits of conventional squeezing are limited. In this paper, we demonstrate the use of a critically-coupled 16m optical cavity to diminish anti-squeezing at frequencies below 90Hz where it exacerbates QRPN, while preserving beneficial squeezing at higher frequencies. This is called an amplitude filter cavity, and it is useful for avoiding degradation of detector sensitivity at low frequencies. The attenuation from the cavity also provides technical advantages such as mitigating backscatter.
△ Less
Submitted 12 November, 2020; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Optimal detuning for quantum filter cavities
Authors:
Chris Whittle,
Kentaro Komori,
Dhruva Ganapathy,
Lee McCuller,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Vacuum quantum fluctuations impose a fundamental limit on the sensitivity of gravitational-wave interferometers, which rank among the most sensitive precision measurement devices ever built. The injection of conventional squeezed vacuum reduces quantum noise in one quadrature at the expense of increasing noise in the other. While this approach improved the sensitivity of the Advanced LIGO and Adva…
▽ More
Vacuum quantum fluctuations impose a fundamental limit on the sensitivity of gravitational-wave interferometers, which rank among the most sensitive precision measurement devices ever built. The injection of conventional squeezed vacuum reduces quantum noise in one quadrature at the expense of increasing noise in the other. While this approach improved the sensitivity of the Advanced LIGO and Advanced Virgo interferometers during their third observing run (O3), future improvements in arm power and squeezing levels will bring radiation pressure noise to the forefront. Installation of a filter cavity for frequency-dependent squeezing provides broadband reduction of quantum noise through the mitigation of this radiation pressure noise, and it is the baseline approach planned for all of the future gravitational-wave detectors currently conceived. The design and operation of a filter cavity requires careful consideration of interferometer optomechanics as well as squeezing degradation processes. In this paper, we perform an in-depth analysis to determine the optimal operating point of a filter cavity. We use our model alongside numerical tools to study the implications for filter cavities to be installed in the upcoming "A+" upgrade of the Advanced LIGO detectors.
△ Less
Submitted 12 November, 2020; v1 submitted 18 August, 2020;
originally announced August 2020.
-
Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA
Authors:
Yuta Michimura,
Kentaro Komori,
Yutaro Enomoto,
Koji Nagano,
Atsushi Nishizawa,
Eiichi Hirose,
Matteo Leonardi,
Eleonora Capocasa,
Naoki Aritomi,
Yuhang Zhao,
Raffaele Flaminio,
Takafumi Ushiba,
Tomohiro Yamada,
Li-Wei Wei,
Hiroki Takeda,
Satoshi Tanioka,
Masaki Ando,
Kazuhiro Yamamoto,
Kazuhiro Hayama,
Sadakazu Haino,
Kentaro Somiya
Abstract:
Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possi…
▽ More
Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possible KAGRA upgrades with technologies focusing on different detector bands, and compare the impacts on the detection of compact binary coalescences. We show that either fivefold improvement in the $100 M_{\odot}$--$100 M_{\odot}$ binary black hole range, a factor of 1.3 improvement in the binary neutron star range, or a factor of 1.7 improvement in the sky localization of binary neutron stars is well feasible with upgrades that do not require changes in the existing cryogenic or vacuum infrastructure. We also show that twofold broadband sensitivity improvement is possible by applying multiple upgrades to the detector.
△ Less
Submitted 24 July, 2020; v1 submitted 16 June, 2020;
originally announced June 2020.
-
Overview of KAGRA: Detector design and construction history
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. -W. Bae,
Y. -B. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. -L. Chan,
C. -S. Chen,
K. -H. Chen,
Y. -R. Chen,
H. -Y. Chu,
Y-K. Chu,
S. Eguchi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (175 additional authors not shown)
Abstract:
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA…
▽ More
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.
△ Less
Submitted 2 July, 2020; v1 submitted 12 May, 2020;
originally announced May 2020.
-
Quantum sensing with milligram scale optomechanical systems
Authors:
Yuta Michimura,
Kentaro Komori
Abstract:
Probing the boundary between classical and quantum mechanics has been one of the central themes in modern physics. Recently, experiments to precisely measure the force acting on milligram scale oscillators with optical cavities are attracting interest as promising tools to test quantum mechanics, decoherence mechanisms, and gravitational physics. In this paper, we review the present status of expe…
▽ More
Probing the boundary between classical and quantum mechanics has been one of the central themes in modern physics. Recently, experiments to precisely measure the force acting on milligram scale oscillators with optical cavities are attracting interest as promising tools to test quantum mechanics, decoherence mechanisms, and gravitational physics. In this paper, we review the present status of experiments using milligram scale optomechanical systems. We compare the feasibility of reaching the quantum regime with a pendulum, torsion pendulum, and optically levitated mirror. Considerations for designing a high $Q$ pendulum, condition for torsion pendulums to have better force sensitivity than pendulums, and constraints in designing optical levitation of a mirror are presented.
△ Less
Submitted 30 March, 2020;
originally announced March 2020.
-
Frequency-Dependent Squeezing for Advanced LIGO
Authors:
L. McCuller,
C. Whittle,
D. Ganapathy,
K. Komori,
M. Tse,
A. Fernandez-Galiana,
L. Barsotti,
P. Fritschel,
M. MacInnis,
F. Matichard,
K. Mason,
N. Mavalvala,
R. Mittleman,
Haocun Yu,
M. E. Zucker,
M. Evans
Abstract:
The first detection of gravitational waves by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational wave astronomy. The quest for gravitational wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of li…
▽ More
The first detection of gravitational waves by the Laser Interferometer Gravitational-wave Observatory (LIGO) in 2015 launched the era of gravitational wave astronomy. The quest for gravitational wave signals from objects that are fainter or farther away impels technological advances to realize ever more sensitive detectors. Since 2019, one advanced technique, the injection of squeezed states of light is being used to improve the shot noise limit to the sensitivity of the Advanced LIGO detectors, at frequencies above $\sim 50$ Hz. Below this frequency, quantum back action, in the form of radiation pressure induced motion of the mirrors, degrades the sensitivity. To simultaneously reduce shot noise at high frequencies and quantum radiation pressure noise at low frequencies requires a quantum noise filter cavity with low optical losses to rotate the squeezed quadrature as a function of frequency. We report on the observation of frequency-dependent squeezed quadrature rotation with rotation frequency of 30Hz, using a 16m long filter cavity. A novel control scheme is developed for this frequency-dependent squeezed vacuum source, and the results presented here demonstrate that a low-loss filter cavity can achieve the squeezed quadrature rotation necessary for the next planned upgrade to Advanced LIGO, known as "A+."
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
A Cryogenic Silicon Interferometer for Gravitational-wave Detection
Authors:
Rana X Adhikari,
Odylio Aguiar,
Koji Arai,
Bryan Barr,
Riccardo Bassiri,
Garilynn Billingsley,
Ross Birney,
David Blair,
Joseph Briggs,
Aidan F Brooks,
Daniel D Brown,
Huy-Tuong Cao,
Marcio Constancio,
Sam Cooper,
Thomas Corbitt,
Dennis Coyne,
Edward Daw,
Johannes Eichholz,
Martin Fejer,
Andreas Freise,
Valery Frolov,
Slawomir Gras,
Anna Green,
Hartmut Grote,
Eric K Gustafson
, et al. (86 additional authors not shown)
Abstract:
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new inst…
▽ More
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.
△ Less
Submitted 9 June, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
T. Akutsu,
M. Ando,
K. Arai,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu,
K. Doi,
S. Eguchi,
Y. Enomoto
, et al. (181 additional authors not shown)
Abstract:
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, wh…
▽ More
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
△ Less
Submitted 28 November, 2019; v1 submitted 2 October, 2019;
originally announced October 2019.
-
Atto-Nm Torque Sensing with a Macroscopic Optomechanical Torsion Pendulum
Authors:
Kentaro Komori,
Yutaro Enomoto,
Ching Pin Ooi,
Yuki Miyazaki,
Nobuyuki Matsumoto,
Vivishek Sudhir,
Yuta Michimura,
Masaki Ando
Abstract:
Precise measurements of the displacement of, and force acting on, a mechanical oscillator can be performed by coupling the oscillator to an optical cavity. Brownian thermal forces represent a fundamental limit to measurement sensitivity which impedes the ability to use precise force measurements as a tool of fundamental enquiry, particularly in the context of macroscopic quantum measurements and t…
▽ More
Precise measurements of the displacement of, and force acting on, a mechanical oscillator can be performed by coupling the oscillator to an optical cavity. Brownian thermal forces represent a fundamental limit to measurement sensitivity which impedes the ability to use precise force measurements as a tool of fundamental enquiry, particularly in the context of macroscopic quantum measurements and table-top gravitational experiments. A torsion pendulum with a low mechanical resonant frequency can be limited by very small thermal forces - from its suspensions - at frequencies above resonance. Here, we report torque sensing of a 10-mg torsion pendulum formed by a bar mirror, using two optical cavities on either edge. The rotational mode was measured by subtracting the two signals from the cavities, while intracavity radiation pressure forces were used to trap the torsional mode with a 1 kHz optical spring. The resulting torque sensitivity of 20 aNm/$\sqrt{\rm Hz}$ is a record for a milligram scale torsion pendulum. Such a massive optomechanical device featuring high sensitivity can shed light on macroscopic quantum mechanics and gravitational physics.
△ Less
Submitted 17 January, 2020; v1 submitted 30 July, 2019;
originally announced July 2019.
-
Prospects for improving the sensitivity of KAGRA gravitational wave detector
Authors:
Yuta Michimura,
Masaki Ando,
Eleonora Capocasa,
Yutaro Enomoto,
Raffaele Flaminio,
Sadakazu Haino,
Kazuhiro Hayama,
Eiichi Hirose,
Yousuke Itoh,
Tomoya Kinugawa,
Kentro Komori,
Matteo Leonardi,
Norikatsu Mio,
Koji Nagano,
Hiroyuki Nakano,
Atsushi Nishizawa,
Norichika Sago,
Masaru Shibata,
Hisaaki Shinkai,
Kentaro Somiya,
Hiroki Takeda,
Takahiro Tanaka,
Satoshi Tanioka,
Li-Wei Wei,
Kazuhiro Yamamoto
Abstract:
KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the tes…
▽ More
KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the test mass mirrors. In this paper, investigations on the upgrade plans which can be realized by changing the input laser power, increasing the mirror mass, and injecting frequency dependent squeezed vacuum are presented. We show how each upgrade affects to the detector frequency bands and also discuss impacts on gravitational-wave science. We then propose an effective progression of upgrades based on technical feasibility and scientific scenarios.
△ Less
Submitted 6 June, 2019;
originally announced June 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Vibration isolation system with a compact dam** system for power recycling mirrors of KAGRA
Authors:
Y. Akiyama,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
V. Dattilo,
K. Doi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (149 additional authors not shown)
Abstract:
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main st…
▽ More
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient dam** performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the dam** performance, and also on estimated residual displacement of the optics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto
, et al. (169 additional authors not shown)
Abstract:
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Tel…
▽ More
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.
-
Particle swarm optimization of the sensitivity of a cryogenic gravitational wave detector
Authors:
Yuta Michimura,
Kentaro Komori,
Atsushi Nishizawa,
Hiroki Takeda,
Koji Nagano,
Yutaro Enomoto,
Kazuhiro Hayama,
Kentaro Somiya,
Masaki Ando
Abstract:
Cryogenic cooling of the test masses of interferometric gravitational wave detectors is a promising way to reduce thermal noise. However, cryogenic cooling limits the incident power to the test masses, which limits the freedom of sha** the quantum noise. Cryogenic cooling also requires short and thick suspension fibers to extract heat, which could result in the worsening of thermal noise. Theref…
▽ More
Cryogenic cooling of the test masses of interferometric gravitational wave detectors is a promising way to reduce thermal noise. However, cryogenic cooling limits the incident power to the test masses, which limits the freedom of sha** the quantum noise. Cryogenic cooling also requires short and thick suspension fibers to extract heat, which could result in the worsening of thermal noise. Therefore, careful tuning of multiple parameters is necessary in designing the sensitivity of cryogenic gravitational wave detectors. Here, we propose the use of particle swarm optimization to optimize the parameters of these detectors. We apply it for designing the sensitivity of the KAGRA detector, and show that binary neutron star inspiral range can be improved by 10%, just by retuning seven parameters of existing components. We also show that the sky localization of GW170817-like binaries can be further improved by a factor of 1.6 averaged across the sky. Our results show that particle swarm optimization is useful for designing future gravitational wave detectors with higher dimensionality in the parameter space.
△ Less
Submitted 5 December, 2018; v1 submitted 26 April, 2018;
originally announced April 2018.
-
A Direct Approach for the Fluctuation-Dissipation Theorem under Non-Equilibrium Steady-State Conditions
Authors:
Kentaro Komori,
Yutaro Enomoto,
Hiroki Takeda,
Yuta Michimura,
Kentaro Somiya,
Masaki Ando,
Stefan W. Ballmer
Abstract:
The test mass suspensions of cryogenic gravitational-wave detectors such as the KAGRA project are tasked with extracting the heat deposited on the optics. Thus these suspensions have a non-uniform temperature, requiring the calculation of thermal noise in non-equilibrium conditions. While it is not possible to describe the whole suspension system with one temperature, the local temperature anywher…
▽ More
The test mass suspensions of cryogenic gravitational-wave detectors such as the KAGRA project are tasked with extracting the heat deposited on the optics. Thus these suspensions have a non-uniform temperature, requiring the calculation of thermal noise in non-equilibrium conditions. While it is not possible to describe the whole suspension system with one temperature, the local temperature anywhere in the system is still well defined. We therefore generalize the application of the fluctuation-dissipation theorem to mechanical systems, pioneered by Saulson and Levin, to non-equilibrium conditions in which a temperature can only be defined locally. The result is intuitive in the sense that the temperature-averaging relevant for the thermal noise in the observed degree of freedom is given by averaging the temperature field, weighted by the dissipation density associated with that particular degree of freedom. After proving this theorem we apply the result to examples of increasing complexity: a simple spring, the bending of a pendulum suspension fiber, as well as a model of the KAGRA cryogenic suspension. We conclude by outlining the application to non-equilibrium thermo-elastic noise.
△ Less
Submitted 1 March, 2018;
originally announced March 2018.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
The status of KAGRA underground cryogenic gravitational wave telescope
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
M. A. Barton,
K. Cannon,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
Y. Fujii,
M. -K. Fujimoto,
T. Furuhata,
S. Haino,
K. Hasegawa,
K. Hashino,
K. Hayama,
S. Hirobayashi
, et al. (126 additional authors not shown)
Abstract:
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial ph…
▽ More
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial phase operation of the interferometer with a simple 3-km Michelson configuration have been completed. The first cryogenic operation is expected in 2018, and the observing runs with a full interferometer are expected in 2020s. The basic interferometer configuration and the current status of KAGRA are described.
△ Less
Submitted 13 October, 2017;
originally announced October 2017.
-
Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope
Authors:
Yuta Michimura,
Tomofumi Shimoda,
Takahiro Miyamoto,
Ayaka Shoda,
Koki Okutomi,
Yoshinori Fujii,
Hiroki Tanaka,
Mark A. Barton,
Ryutaro Takahashi,
Yoichi Aso,
Tomotada Akutsu,
Masaki Ando,
Yutaro Enomoto,
Raffaele Flaminio,
Kazuhiro Hayama,
Eiichi Hirose,
Yuki Inoue,
Takaaki Kajita,
Masahiro Kamiizumi,
Seiji Kawamura,
Keiko Kokeyama,
Kentaro Komori,
Rahul Kumar,
Osamu Miyakawa,
Koji Nagano
, et al. (14 additional authors not shown)
Abstract:
KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and vari…
▽ More
KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and various noises for mirror actuation. Using our model, we have designed the actuation parameters to have sufficient force range to acquire lock as well as to control all the length degrees of freedom without introducing excess noise.
△ Less
Submitted 21 June, 2019; v1 submitted 8 September, 2017;
originally announced September 2017.
-
Direct measurement of the optical trap-induced decoherence
Authors:
Nobuyuki Matsumoto,
Kentaro Komori,
Sosuke Ito,
Yuta Michimura,
Yoichi Aso
Abstract:
Thermal decoherence is a major obstacle to the realization of quantum coherence for massive mechanical oscillators. Although optical trap** has been used to reduce the thermal decoherence rate for such oscillators, it also increases the rate by subjecting the oscillator to stochastic forces resulting from the frequency fluctuations of the optical field, thereby setting a fundamental limit on the…
▽ More
Thermal decoherence is a major obstacle to the realization of quantum coherence for massive mechanical oscillators. Although optical trap** has been used to reduce the thermal decoherence rate for such oscillators, it also increases the rate by subjecting the oscillator to stochastic forces resulting from the frequency fluctuations of the optical field, thereby setting a fundamental limit on the reduction. This is analogous to the noise penalty in an active feedback system. Here, we directly measure the rethermalizaton process for an initially cooled and optically trapped suspended mirror, and identify the current limiting decoherence rate as due to the optical trap. Our experimental study of the trap-induced decoherence rate will enable future advances in the probing of fundamental quantum mechanics in the bad cavity regime, such as testing of deformed commutators.
△ Less
Submitted 20 August, 2016; v1 submitted 17 March, 2016;
originally announced March 2016.
-
5-mg suspended mirror driven by measurement-induced back-action
Authors:
Nobuyuki Matsumoto,
Kentaro Komori,
Yuta Michimura,
Gen Hayase,
Yoichi Aso,
Kimio Tsubono
Abstract:
Quantum mechanics predicts superposition of position states even for macroscopic objects. Recently, the use of a quasi-freely suspended mirror combined with laser was proposed to prepare such states, by Müller-Ebhardt et al. [Phys.Rev.Lett.100, 013601 (2008)]. One of the key milestones towards this goal is the preparation of the mechanical oscillator mainly driven by quantum back-action, which ide…
▽ More
Quantum mechanics predicts superposition of position states even for macroscopic objects. Recently, the use of a quasi-freely suspended mirror combined with laser was proposed to prepare such states, by Müller-Ebhardt et al. [Phys.Rev.Lett.100, 013601 (2008)]. One of the key milestones towards this goal is the preparation of the mechanical oscillator mainly driven by quantum back-action, which identifies the connection between the object and quantumness of the light. Here, we describe development of a suspended 5-mg mirror driven by quantum back-action larger than thermal fluctuating force by a factor of 1.4$\pm$0.2 at 325 Hz,which is confirmed by using a triangular optical cavity.
△ Less
Submitted 17 January, 2015; v1 submitted 17 December, 2013;
originally announced December 2013.