-
Embedded quantitative MRI T1rho map** using non-linear primal-dual proximal splitting
Authors:
Matti Hanhela,
Antti Paajanen,
Mikko J. Nissi,
Ville Kolehmainen
Abstract:
Quantitative MRI (qMRI) methods allow reducing the subjectivity of clinical MRI by providing numerical values on which diagnostic assessment or predictions of tissue properties can be based. However, qMRI measurements typically take more time than anatomical imaging due to requiring multiple measurements with varying contrasts for, e.g., relaxation time map**. To reduce the scanning time, unders…
▽ More
Quantitative MRI (qMRI) methods allow reducing the subjectivity of clinical MRI by providing numerical values on which diagnostic assessment or predictions of tissue properties can be based. However, qMRI measurements typically take more time than anatomical imaging due to requiring multiple measurements with varying contrasts for, e.g., relaxation time map**. To reduce the scanning time, undersampled data may be combined with compressed sensing reconstruction techniques. Typical CS reconstructions first reconstruct a complex-valued set of images corresponding to the varying contrasts, followed by a non-linear signal model fit to obtain the parameter maps. We propose a direct, embedded reconstruction method for T1rho map**. The proposed method capitalizes on a known signal model to directly reconstruct the desired parameter map using a non-linear optimization model. The proposed reconstruction method also allows directly regularizing the parameter map of interest, and greatly reduces the number of unknowns in the reconstruction. We test the proposed model using a simulated radially sampled data from a 2D phantom and 2D cartesian ex vivo measurements of a mouse kidney specimen. We compare the embedded reconstruction model to two CS reconstruction models, and in the cartesian test case also iFFT. The proposed, embedded model outperformed the reference methods on both test cases, especially with higher acceleration factors.
△ Less
Submitted 14 February, 2022;
originally announced February 2022.
-
Data-driven regularization parameter selection in dynamic MRI
Authors:
Matti Hanhela,
Olli Gröhn,
Mikko Kettunen,
Kati Niinimäki,
Marko Vauhkonen,
Ville Kolehmainen
Abstract:
In dynamic MRI, sufficient time resolution can often only be obtained using imaging protocols which produce undersampled data for each image in the time series. This has led to the popularity of compressed sensing (CS) based image reconstruction approaches. One of the problems in CS approaches is determining the regularization parameters, which control the balance between data fidelity the spatial…
▽ More
In dynamic MRI, sufficient time resolution can often only be obtained using imaging protocols which produce undersampled data for each image in the time series. This has led to the popularity of compressed sensing (CS) based image reconstruction approaches. One of the problems in CS approaches is determining the regularization parameters, which control the balance between data fidelity the spatial and temporal regularization terms. A data-driven approach is proposed for the total variation regularization parameter selection such that the reconstructions yield expected sparsity levels in the regularization domains. The expected sparsity levels are obtained from the measurement data for the temporal regularization and from a reference image for the spatial regularization. Two formulations are proposed. The first is a 2D search for a parameter pair which produces expected sparsity in both the temporal and spatial regularization domains. In the second approach, the sparsity-based parameter selection is split to two 1D searches using the S-curve method. The approaches are evaluated using simulated and experimental DCE-MRI. In the simulated test case, both proposed methods produce a parameter pair that is close to the RMSE optimal pair, and the reconstruction error is also close to minimum. In the experimental test case, the methods produce almost similar parameter selection, and the reconstructions are of high perceived quality. Both approaches lead to a highly feasible selection of the temporal and spatial regularization parameters in both the simulated and experimental test cases while the sequential method is computationally more efficient.
△ Less
Submitted 25 November, 2020; v1 submitted 3 April, 2020;
originally announced April 2020.
-
Temporal Huber regularization for DCE-MRI
Authors:
Matti Hanhela,
Mikko Kettunen,
Olli Gröhn,
Marko Vauhkonen,
Ville Kolehmainen
Abstract:
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to study microvascular structure and tissue perfusion. In DCE-MRI a bolus of gadolinium based contrast agent is injected into the blood stream and spatiotemporal changes induced by the contrast agent flow are estimated from a time series of MRI data. Sufficient time resolution can often only be obtained by using an imaging prot…
▽ More
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to study microvascular structure and tissue perfusion. In DCE-MRI a bolus of gadolinium based contrast agent is injected into the blood stream and spatiotemporal changes induced by the contrast agent flow are estimated from a time series of MRI data. Sufficient time resolution can often only be obtained by using an imaging protocol which produces undersampled data for each image in the time series. This has led to the popularity of compressed sensing based image reconstruction approaches, where all the images in the time series are reconstructed simultaneously, and temporal coupling between the images is introduced into the problem by a sparsity promoting regularization functional. We propose the use of Huber penalty for temporal regularization in DCE-MRI, and compare it to total variation, total generalized variation and smoothness based temporal regularization models. We also study the effect of spatial regularization to the reconstruction and compare the reconstruction accuracy with different temporal resolutions due to varying undersampling. The approaches are tested using simulated and experimental radial golden angle DCE-MRI data from a rat brain specimen. The results indicate that Huber regularization produces similar reconstruction accuracy with the total variation based models, but the computation times are significantly faster.
△ Less
Submitted 21 September, 2020; v1 submitted 19 March, 2020;
originally announced March 2020.
-
Joint Reconstruction in Low Dose Multi-Energy CT
Authors:
Jussi Toivanen,
Alexander Meaney,
Samuli Siltanen,
Ville Kolehmainen
Abstract:
Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost of a higher radiation dose. A straightforward way to lower the dose is to reduce the number of projections per energy, but this makes tomographic reconstruction…
▽ More
Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost of a higher radiation dose. A straightforward way to lower the dose is to reduce the number of projections per energy, but this makes tomographic reconstruction more ill-posed. In this paper, we propose how this problem can be overcome with a combination of a regularization method that promotes structural similarity between images at different energies and a suitably selected low-dose data acquisition protocol using non-overlap** projections. The performance of various joint regularization models is assessed with both simulated and experimental data, using the novel low-dose data acquisition protocol. Three of the models are well-established, namely the joint total variation, the linear parallel level sets and the spectral smoothness promoting regularization models. Furthermore, one new joint regularization model is introduced for multi-energy CT: a regularization based on the structure function from the structural similarity index. The findings show that joint regularization outperforms individual channel-by-channel reconstruction. Furthermore, the proposed combination of joint reconstruction and non-overlap** projection geometry enables significant reduction of radiation dose.
△ Less
Submitted 13 February, 2020; v1 submitted 11 April, 2019;
originally announced April 2019.
-
Open 2D Electrical Impedance Tomography data archive
Authors:
Andreas Hauptmann,
Ville Kolehmainen,
Nguyet Minh Mach,
Tuomo Savolainen,
Aku Seppänen,
Samuli Siltanen
Abstract:
This document reports an Open 2D Electrical Impedance Tomography (EIT) data set. The EIT measurements were collected from a circular body (a flat tank filled with saline) with various choices of conductive and resistive inclusions. Data are available at http://fips.fi/ EIT_dataset.php and can be freely used for scientific purposes with appropriate references to them, and to this document at https:…
▽ More
This document reports an Open 2D Electrical Impedance Tomography (EIT) data set. The EIT measurements were collected from a circular body (a flat tank filled with saline) with various choices of conductive and resistive inclusions. Data are available at http://fips.fi/ EIT_dataset.php and can be freely used for scientific purposes with appropriate references to them, and to this document at https://arxiv.longhoe.net. The data set consists of (1) current patterns and voltage measurements of a circular tank containing different targets, (2) photos of the tank and targets and (3) a MATLAB-code for reading the data. A video report of the data collection session is available at https://www.youtube.com/watch?v=65Zca_qd1Y8.
△ Less
Submitted 4 April, 2017;
originally announced April 2017.
-
Approximate Marginalization of Absorption and Scattering in Fluorescence Diffuse Optical Tomography
Authors:
Meghdoot Mozumder,
Tanja Tarvainen,
Simon Arridge,
Jari P. Kaipio,
Cosimo d'Andrea,
Ville Kolehmainen
Abstract:
In fluorescence diffuse optical tomography (fDOT), the reconstruction of the fluorophore concentration inside the target body is usually carried out using a normalized Born approximation model where the measured fluorescent emission data is scaled by measured excitation data. One of the benefits of the model is that it can tolerate inaccuracy in the absorption and scattering distributions that are…
▽ More
In fluorescence diffuse optical tomography (fDOT), the reconstruction of the fluorophore concentration inside the target body is usually carried out using a normalized Born approximation model where the measured fluorescent emission data is scaled by measured excitation data. One of the benefits of the model is that it can tolerate inaccuracy in the absorption and scattering distributions that are used in the construction of the forward model to some extent. In this paper, we employ the recently proposed Bayesian approximation error approach to fDOT for compensating for the modeling errors caused by the inaccurately known optical properties of the target in combination with the normalized Born approximation model. The approach is evaluated using a simulated test case with different amount of error in the optical properties. The results show that the Bayesian approximation error approach improves the tolerance of fDOT imaging against modeling errors caused by inaccurately known absorption and scattering of the target.
△ Less
Submitted 2 January, 2015;
originally announced January 2015.
-
Estimation of conductivity changes in a region of interest with electrical impedance tomography
Authors:
Dong Liu,
Ville Kolehmainen,
Samuli Siltanen,
Anne maria Laukkanen,
Aku Seppanen
Abstract:
This paper proposes a novel approach to reconstruct changes in a target conductivity from electrical impedance tomography measurements. As in the conventional difference imaging, the reconstruction of the conductivity change is based on electrical potential measurements from the exterior boundary of the target before and after the change. In this paper, however, images of the conductivity before a…
▽ More
This paper proposes a novel approach to reconstruct changes in a target conductivity from electrical impedance tomography measurements. As in the conventional difference imaging, the reconstruction of the conductivity change is based on electrical potential measurements from the exterior boundary of the target before and after the change. In this paper, however, images of the conductivity before and after the change are reconstructed simultaneously based on the two data sets. The key feature of the approach is that the conductivity after the change is parameterized as a linear combination of the initial state and the change. This allows for modeling independently the spatial characteristics of the background conductivity and the change of the conductivity - by separate regularization functionals. The approach also allows in a straightforward way the restriction of the conductivity change to a localized region of interest inside the domain. While conventional difference imaging reconstruction is based on a global linearization of the observation model, the proposed approach amounts to solving a non-linear inverse problem. The feasibility of the proposed reconstruction method is tested experimentally and with a simulation which demonstrates a potential new medical application of electrical impedance tomography: imaging of vocal folds in voice loading studies.
△ Less
Submitted 26 March, 2014;
originally announced March 2014.