-
Characterization and Novel Application of Power Over Fiber for Electronics in a Harsh Environment
Authors:
M. A. Arroyave,
B. Behera,
F. Cavanna,
A. Feld,
F. Guo,
A. Heindel,
C. K. Jung,
K. Koch,
D. Leon Silverio,
D. A. Martinez Caicedo,
C. McGrew,
A. Paudel,
W. Pellico,
R. Rivera,
J. Rodríguez Rondon,
S. Sacerdoti,
P. Shanahan,
W. Shi,
D. Torres Muñoz,
D. Totani,
C. Uy,
C. Vermeulen,
H. Vieira de Souza
Abstract:
Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at $\sim$ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to t…
▽ More
Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at $\sim$ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R$\&$D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency, and superior isolation.
△ Less
Submitted 27 May, 2024;
originally announced May 2024.
-
Variable Resolution Sampling and Deep Learning-Based Image Recovery for Faster Multi-Spectral Imaging Near Metal Implants
Authors:
Nikolai J. Mickevicius,
Azadeh Sharafi,
Andrew S. Nencka,
Kevin M. Koch
Abstract:
Purpose: In multi-spectral imaging (MSI), several fast spin echo volumes with discrete Larmor frequency offsets are acquired in an interleaved fashion with multiple concatenations. Here, a variable resolution (VR) method to nearly halve scan time is proposed by only acquiring low resolution autocalibrating signal in half of the concatenations.
Methods: Knee MSI datasets were retrospectively unde…
▽ More
Purpose: In multi-spectral imaging (MSI), several fast spin echo volumes with discrete Larmor frequency offsets are acquired in an interleaved fashion with multiple concatenations. Here, a variable resolution (VR) method to nearly halve scan time is proposed by only acquiring low resolution autocalibrating signal in half of the concatenations.
Methods: Knee MSI datasets were retrospectively undersampled with the proposed variable resolution sampling scheme. A U-Net model was trained to predict the full-resolution images from the VR input. Image quality was assessed in 10 test subjects.
Results: Spectral bin-combined images produced with the proposed variable resolution sampling with deep learning reconstruction appear to be of high quality and exhibited a median structural image similarity of 0.984 across test subjects and slices.
Conclusion: The proposed variable resolution sampling method shows promise for drastically reducing the time it takes to collect multi-spectral imaging data near metallic implants. Further studies will rigorously examine its clinical utility across multiple implant scenarios.
△ Less
Submitted 2 June, 2023;
originally announced June 2023.
-
Development and Stability Analysis of Carpal Kinematic Metrics from 4D Magnetic Resonance Imaging
Authors:
Azadeh Sharafi,
Andrew S Nencka,
Kevin M Koch
Abstract:
Introduction: Wrist instability remains a common health concern. The potential of dynamic Magnetic Resonance Imaging (MRI) in assessing carpal dynamics associated with this condition is a field of ongoing research. This study contributes to this line of inquiry by develo** MRI-derived carpal kinematic metrics and investigating their stability. Methods: A previously described 4D MRI approach for…
▽ More
Introduction: Wrist instability remains a common health concern. The potential of dynamic Magnetic Resonance Imaging (MRI) in assessing carpal dynamics associated with this condition is a field of ongoing research. This study contributes to this line of inquiry by develo** MRI-derived carpal kinematic metrics and investigating their stability. Methods: A previously described 4D MRI approach for tracking the movements of carpal bones in the wrist was deployed in this study. A panel of 120 metrics characterizing radial/ulnar deviation and flexion extension movements was constructed by fitting low order polynomial models of scaphoid and lunate degrees of freedom against that of the capitate. Intraclass Correlation Coefficients were utilized to analyze intra- and inter-subject stability within a mixed cohort of 49 subjects, including 20 with and 29 without a history of wrist injury. Results: A comparable degree of stability across the two different wrist movements. Out of the total 120 derived metrics, distinct subsets demonstrated high stability within each type of movement. Among asymptomatic subjects, 16 out of 17 metrics with high intra-subject stability also showed high inter-subject stability. Interestingly, some quadratic term metrics, although relatively unstable within asymptomatic subjects, showed increased stability within this group, hinting at potential differentiation in their behavior across different cohorts. Conclusion: This study showed the develo** potential of dynamic MRI to characterize complex carpal bone dynamics. Stability analyses of the derived kinematic metrics showed encouraging differences between cohorts with and without a history of wrist injury. Although these broad metric stability variations highlight the potential utility of this approach for analysis of carpal instability, further studies are necessary to better characterize these observations.
△ Less
Submitted 25 May, 2023;
originally announced May 2023.
-
Exploring domain adaptation for deep neural network trained QSM
Authors:
Juan Liu,
Kevin Koch
Abstract:
Quantitative susceptibility map** (QSM) is a MRI technique that estimates tissue magnetic susceptibility. The generation of QSM requires solving a challenging ill-posed field-to-source inversion problem. Recently, several deep learning (DL) QSM techniques have been proposed and demonstrated impressive performance. Due to the inherent non-existent ground-truth QSM references, these techniques use…
▽ More
Quantitative susceptibility map** (QSM) is a MRI technique that estimates tissue magnetic susceptibility. The generation of QSM requires solving a challenging ill-posed field-to-source inversion problem. Recently, several deep learning (DL) QSM techniques have been proposed and demonstrated impressive performance. Due to the inherent non-existent ground-truth QSM references, these techniques used either COSMOS maps or synthetic data for network training. Synthetic data is easy to generate but often adapt poorly to in-vivo data due to domain shifts. Here, we introduce an easy domain adaptation technique using domain-specific batch normalization to address this problem.
△ Less
Submitted 24 June, 2022;
originally announced June 2022.
-
Unconstrained Kinematic MRI Tracking of Wrist Carpal Bones
Authors:
Mohammad Zarenia,
Volkan Emre Arpinar,
Andrew S. Nencka,
L. Tugan Muftuler,
Kevin M. Koch
Abstract:
In this preliminary study technical methodology for kinematic tracking and profiling of wrist carpal bones during unconstrained movements is explored. Heavily under-sampled and fat-saturated 3D Cartesian MRI acquisition were used to capture temporal frames of the unconstrained moving wrist of 5 healthy subjects. A slab-to-volume point-cloud based registration was then utilized to register the movi…
▽ More
In this preliminary study technical methodology for kinematic tracking and profiling of wrist carpal bones during unconstrained movements is explored. Heavily under-sampled and fat-saturated 3D Cartesian MRI acquisition were used to capture temporal frames of the unconstrained moving wrist of 5 healthy subjects. A slab-to-volume point-cloud based registration was then utilized to register the moving volumes to a high-resolution image volume set collected at a neutral resting position. Comprehensive error analyses for different acquisition parameter settings were performed to evaluate the performance limits of several derived kinematic metrics. Computational results suggested that sufficient volume coverage for the dynamic acquisitions was reached when collecting 12 slice-encodes at 2.5mm resolution, which yielded a temporal resolution of and 2.57 seconds per volumetric frame. These acquisition parameters resulted in total absolute errors of 1.9$^\circ\pm$1.8$^\circ$ (3$^\circ\pm$4.6$^\circ$) in derived rotation angles and 0.3mm$\pm$0.47mm (0.72mm$\pm$0.8mm) in center-of-mass displacement kinematic profiles within ulnar-radial (flexion-extension) motion. The results of this study have established the feasibility of kinematic metric tracking of unconstrained wrist motion using 4D MRI. Temporal metric profiles derived from ulnar-radial deviation motion demonstrated better performance than those derived from flexion/extension movements. Future work will continue to explore the use of these methods in deriving more complex kinematic metrics and their application to subjects with symptomatic carpal dysfunction.
△ Less
Submitted 8 November, 2021;
originally announced November 2021.
-
On-chip single-photon subtraction by individual silicon vacancy centers in a laser-written diamond waveguide
Authors:
Michael K. Koch,
Michael Hoese,
Vibhav Bharadwaj,
Johannes Lang,
John P. Hadden,
Roberta Ramponi,
Fedor Jelezko,
Shane M. Eaton,
Alexander Kubanek
Abstract:
Modifying light fields at single-photon level is a key challenge for upcoming quantum technologies and can be realized in a scalable manner through integrated quantum photonics. Laser-written diamond photonics offers three-dimensional fabrication capabilities and large mode-field diameters matched to fiber optic technology, though limiting the cooperativity at the single-emitter level. To realize…
▽ More
Modifying light fields at single-photon level is a key challenge for upcoming quantum technologies and can be realized in a scalable manner through integrated quantum photonics. Laser-written diamond photonics offers three-dimensional fabrication capabilities and large mode-field diameters matched to fiber optic technology, though limiting the cooperativity at the single-emitter level. To realize large cooperativities, we combine excitation of single shallow-implanted silicon vacancy centers via large numerical aperture optics with detection assisted by laser-written type-II waveguides. We demonstrate single-emitter extinction measurements with a cooperativity of 0.153 and a beta factor of 13% yielding 15.3% as lower bound for the quantum efficiency of a single emitter. The transmission of resonant photons reveals single-photon subtraction from a quasi-coherent field resulting in super-Poissonian light statistics. Our architecture enables single quantum level light field engineering in an integrated design which can be fabricated in three dimensions and with a natural connectivity to optical fiber arrays.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Deep-learning based Tools for Automated Protocol Definition of Advanced Diagnostic Imaging Exams
Authors:
Andrew S. Nencka,
Mohammad Sherafati,
Timothy Goebel,
Parag Tolat,
Kevin M. Koch
Abstract:
Purpose: This study evaluates the effectiveness and impact of automated order-based protocol assignment for magnetic resonance imaging (MRI) exams using natural language processing (NLP) and deep learning (DL).
Methods: NLP tools were applied to retrospectively process orders from over 116,000 MRI exams with 200 unique sub-specialized protocols ("Local" protocol class). Separate DL models were t…
▽ More
Purpose: This study evaluates the effectiveness and impact of automated order-based protocol assignment for magnetic resonance imaging (MRI) exams using natural language processing (NLP) and deep learning (DL).
Methods: NLP tools were applied to retrospectively process orders from over 116,000 MRI exams with 200 unique sub-specialized protocols ("Local" protocol class). Separate DL models were trained on 70\% of the processed data for "Local" protocols as well as 93 American College of Radiology ("ACR") protocols and 48 "General" protocols. The DL Models were assessed in an "auto-protocoling (AP)" inference mode which returns the top recommendation and in a "clinical decision support (CDS)" inference mode which returns up to 10 protocols for radiologist review. The accuracy of each protocol recommendation was computed and analyzed based on the difference between the normalized output score of the corresponding neural net for the top two recommendations.
Results: The top predicted protocol in AP mode was correct for 82.8%, 73.8%, and 69.3% of the test cases for "General", "ACR", and "Local" protocol classes, respectively. Higher levels of accuracy over 96% were obtained for all protocol classes in CDS mode. However, at current validation performance levels, the proposed models offer modest, positive, financial impact on large-scale imaging networks.
Conclusions: DL-based protocol automation is feasible and can be tuned to route substantial fractions of exams for auto-protocoling, with higher accuracy with more general protocols. Economic analyses of the tested algorithms indicate that improved algorithm performance is required to yield a practical exam auto-protocoling tool for sub-specialized imaging exams.
△ Less
Submitted 28 May, 2021;
originally announced June 2021.
-
Diffusion propagator metrics are biased when simultaneous multi-slice acceleration is used
Authors:
L. Tugan Muftuler,
Andrew S. Nencka,
Kevin M. Koch
Abstract:
Advanced diffusion MRI models are being explored to study the complex microstructure of the brain with higher accuracy. However, these techniques require long acquisition times. Simultaneous multi-slice (SMS) accelerates data acquisition by exciting multiple image slices simultaneously and separating the overlap** slices using a mathematical model. However, this slice separation is not exact and…
▽ More
Advanced diffusion MRI models are being explored to study the complex microstructure of the brain with higher accuracy. However, these techniques require long acquisition times. Simultaneous multi-slice (SMS) accelerates data acquisition by exciting multiple image slices simultaneously and separating the overlap** slices using a mathematical model. However, this slice separation is not exact and leads to crosstalk between simultaneously excited slices. Although this residual leakage is small, it affects quantitative MRI techniques such as diffusion imaging.
In this study, the effects of SMS acceleration on the accuracy of propagator metrics obtained from the MAP-MRI technique was investigated. Ten healthy volunteers were scanned with SMS accelerated multi-shell diffusion MRI acquisitions. Group analyses were performed to study brain regions typically affected by SMS acceleration. In addition, diffusion metrics from atlas based fiber tracts of interest were analyzed to investigate how propagator metrics in major fiber tracts were biased by 2- and 3-band SMS acceleration.
Both zero-displacement metrics and non-Gaussianity metrics were significantly altered when SMS acceleration was used. MAP-MRI metrics calculated from SMS-3 showed significant differences with respect to SMS-2. Furthermore, when shorter TR afforded by SMS acceleration was used, the characteristics of this bias have changed. This has implications for studies using diffusion MRI with SMS acceleration to investigate the effects of a disease or injury on the brain tissues.
△ Less
Submitted 3 May, 2021; v1 submitted 24 March, 2021;
originally announced March 2021.
-
Single photon randomness originating from the symmetry of dipole emission and the unpredictability of spontaneous emission
Authors:
Michael Hoese,
Michael K. Koch,
Felix Breuning,
Niklas Lettner,
Konstantin G. Fehler,
Alexander Kubanek
Abstract:
Quantum random number generation is a key ingredient for quantum cryptography and fundamental quantum optics and could advance Monte-Carlo simulations and machine learning. An established generation scheme is based on single photons im**ing on a beam splitter. Here, we experimentally demonstrate quantum random number generation solely based on the spontaneous emission process in combination with…
▽ More
Quantum random number generation is a key ingredient for quantum cryptography and fundamental quantum optics and could advance Monte-Carlo simulations and machine learning. An established generation scheme is based on single photons im**ing on a beam splitter. Here, we experimentally demonstrate quantum random number generation solely based on the spontaneous emission process in combination with the symmetric emission profile of a dipole aligned orthogonal to the laboratory frame. The demonstration builds on defect centers in hexagonal boron nitride and benefits from the ability to manipulate and align the emission directionality. We prove the randomness in the correlated photon detection events making use of the NIST randomness test suite and show that the randomness remains for two independently emitting defect centers. The scheme can be extended to random number generation by coherent single photons with potential applications in solid-state based quantum communication at room temperature.
△ Less
Submitted 18 February, 2021;
originally announced February 2021.
-
An integrated magnetometry platform with stackable waveguide-assisted detection channels for sensing arrays
Authors:
Michael Hoese,
Michael K. Koch,
Vibhav Bharadwaj,
Johannes Lang,
John P. Hadden,
Reina Yoshizaki,
Argyro N. Giakoumaki,
Roberta Ramponi,
Fedor Jelezko,
Shane M. Eaton,
Alexander Kubanek
Abstract:
The negatively-charged NV$^-$-center in diamond has shown great success in nanoscale, high-sensitivity magnetometry. Efficient fluorescence detection is crucial for improving the sensitivity. Furthermore, integrated devices enable practicable sensors. Here, we present a novel architecture which allows us to create NV$^-$-centers a few nanometers below the diamond surface, and at the same time in t…
▽ More
The negatively-charged NV$^-$-center in diamond has shown great success in nanoscale, high-sensitivity magnetometry. Efficient fluorescence detection is crucial for improving the sensitivity. Furthermore, integrated devices enable practicable sensors. Here, we present a novel architecture which allows us to create NV$^-$-centers a few nanometers below the diamond surface, and at the same time in the mode field maximum of femtosecond-laser-written type-II waveguides. We experimentally verify the coupling efficiency, showcase the detection of magnetic resonance signals through the waveguides and perform first proof-of-principle experiments in magnetic field and temperature sensing. The sensing task can be operated via the waveguide without direct light illumination through the sample, which marks an important step for magnetometry in biological systems which are fragile to light. In the future, our approach will enable the development of two-dimensional sensing arrays facilitating spatially and temporally correlated magnetometry.
△ Less
Submitted 4 December, 2020;
originally announced December 2020.
-
Split Slice Training Augmentation and Hyperparameter Tuning of RAKI Networks for Simultaneous Multi-Slice Reconstruction
Authors:
Andrew S. Nencka,
PhD,
Volkan E. Arpinar,
PhD,
Sampada Bhave,
PhD,
Baolian Yang,
PhD,
Suchandrima Banerjee,
Michael McCrea,
PhD,
Nikolai J. Mickevicius,
L. Tugan Muftuler,
Kevin M. Koch
Abstract:
Split-slice augmentation for simultaneous multi-slice RAKI networks positively impacts network performance. Hyperparameter tuning of such reconstruction networks can lead to further improvements in unaliasing performance.
Split-slice augmentation for simultaneous multi-slice RAKI networks positively impacts network performance. Hyperparameter tuning of such reconstruction networks can lead to further improvements in unaliasing performance.
△ Less
Submitted 2 June, 2020;
originally announced June 2020.
-
Mechanical Decoupling of Quantum Emitters in Hexagonal Boron Nitride from Low-Energy Phonon Modes
Authors:
Michael Hoese,
Prithvi Reddy,
Andreas Dietrich,
Michael K. Koch,
Konstantin G. Fehler,
Marcus W. Doherty,
Alexander Kubanek
Abstract:
Quantum emitters in hexagonal Boron Nitride (hBN) were recently reported to hol a homogeneous linewidth according to the Fourier-Transform limit up to room temperature. This unusual observation was traced back to decoupling from in-plane phonon modes which can arise if the emitter is located between two planes of the hBN host material. In this work, we investigate the origins for the mechanical de…
▽ More
Quantum emitters in hexagonal Boron Nitride (hBN) were recently reported to hol a homogeneous linewidth according to the Fourier-Transform limit up to room temperature. This unusual observation was traced back to decoupling from in-plane phonon modes which can arise if the emitter is located between two planes of the hBN host material. In this work, we investigate the origins for the mechanical decoupling. Improved sample preparation enabled a reduced background and a 70-fold decrease of spectral diffusion which was so far the major drawback of defect center in hBN and allowed us to reveal a gap in the electron-phonon spectral density for low phonon frequencies. This decoupling from phonons persists at room temperature and explains the observed Fourier Transform limited lines up to 300K. Furthermore, we investigate the dipole emission directionality and show a preferred photon emission through the side of the hBN flakes supporting the claim for an out-of-plane distortion of the defect center. Our work lays the foundation to a deeper understanding of the underlying physics for the persistence of Fourier-Transform limit lines up to room temperature. It furthermore provides a description on how to identify the mechanically isolated emitter within the large number of defect centers in hBN. Therefore, it paves the way for quantum optics applications with defect centers in hBN at room temperature.
△ Less
Submitted 22 April, 2020;
originally announced April 2020.
-
Model-based Learning for Quantitative Susceptibility Map**
Authors:
Juan Liu,
Kevin M. Koch
Abstract:
Quantitative susceptibility map** (QSM) is a magnetic resonance imaging (MRI) technique that estimates magnetic susceptibility of tissue from Larmor frequency offset measurements. The generation of QSM requires solving a challenging ill-posed field-to-source inversion problem. Inaccurate field-to-source inversion often causes large susceptibility estimation errors that appear as streaking artifa…
▽ More
Quantitative susceptibility map** (QSM) is a magnetic resonance imaging (MRI) technique that estimates magnetic susceptibility of tissue from Larmor frequency offset measurements. The generation of QSM requires solving a challenging ill-posed field-to-source inversion problem. Inaccurate field-to-source inversion often causes large susceptibility estimation errors that appear as streaking artifacts in the QSM, especially in massive hemorrhagic regions. Recently, several deep learning (DL) QSM techniques have been proposed and demonstrated impressive performance. Due to the inherent non-existent ground-truth QSM references, these DL techniques used either calculation of susceptibility through multiple orientation sampling (COSMOS) maps or synthetic data for network training. Therefore, they were constrained by the availability and accuracy of COSMOS maps, or suffered from performance drop when the training and testing domains were different. To address these limitations, we present a model-based DL method, denoted as uQSM. Without accessing to QSM labels, uQSM is trained using the well-established physical model. When evaluating on multi-orientation QSM datasets, uQSM achieves higher levels of quantitative accuracy compared to TKD, TV-FANSI, MEDI, and DIP approaches. When qualitatively evaluated on single-orientation datasets, uQSM outperforms other methods and reconstructed high quality QSM.
△ Less
Submitted 17 August, 2020; v1 submitted 13 April, 2020;
originally announced April 2020.
-
Optimization of hyperparameters for SMS reconstruction
Authors:
L. Tugan Muftuler,
Volkan Emre Arpinar,
Kevin Koch,
Sampada Bhave,
Baolian Yang,
Sivaram Kaushik,
Suchandrima Banerjee,
Andrew Nencka
Abstract:
Simultaneous multi-slice (SMS) imaging accelerates MRI data acquisition by exciting multiple image slices simultaneously. Overlap** slices are then separated using a mathematical model. Several parameters used in SMS reconstruction impact the quality of final images. Therefore, finding an optimal set of reconstruction parameters is critical to ensure that SMS acceleration does not significantly…
▽ More
Simultaneous multi-slice (SMS) imaging accelerates MRI data acquisition by exciting multiple image slices simultaneously. Overlap** slices are then separated using a mathematical model. Several parameters used in SMS reconstruction impact the quality of final images. Therefore, finding an optimal set of reconstruction parameters is critical to ensure that SMS acceleration does not significantly degrade resulting image quality.
Gradient-echo echo planar imaging (EPI) data were acquired with a range of SMS acceleration factors from volunteers. Images were collected using two head coils (a 48-channel array and a smaller 32-channel array). Data from these coils were reconstructed offline using a range of coil compression factors and reconstruction kernel parameters. A hybrid space (ky-x), externally-calibrated coil-by-coil slice unaliasing approach was used for image reconstruction. The resulting SMS images were compared with identical EPI data acquired without SMS. A functional MRI (fMRI) experiment was also performed and group analysis results were compared between data sets reconstructed with different coil compression levels.
The 32-channel coil with smaller dimensions outperformed the larger 48-channel coil in our experiments. Generally, a large calibration region and small kernel sizes in ky direction improved image quality. Use of regularization in the kernel fitting procedure had a notable impact. With optimal selection of other hyperparameters in the hybrid space SMS unaliasing algorithm, coil compression caused small reduction in quality in SMS accelerated images. Similarly, group analysis of fMRI results did not show a significant influence of coil compression on resulting image quality.
Hyperparameters used in SMS reconstruction need to be fine-tuned once the experimental factors such as the RF receive coil and SMS factor have been determined.
△ Less
Submitted 10 April, 2020;
originally announced April 2020.
-
Meta-QSM: An Image-Resolution-Arbitrary Network for QSM Reconstruction
Authors:
Juan Liu,
Kevin M. Koch
Abstract:
Quantitative Susceptibility Map** (QSM) can estimate the underlying tissue magnetic susceptibility and reveal pathology. Current deep-learning-based approaches to solve the QSM inverse problem are restricted on fixed image resolution. They trained a specific model for each image resolution which is inefficient in computing. In this work, we proposed a novel method called Meta-QSM to firstly solv…
▽ More
Quantitative Susceptibility Map** (QSM) can estimate the underlying tissue magnetic susceptibility and reveal pathology. Current deep-learning-based approaches to solve the QSM inverse problem are restricted on fixed image resolution. They trained a specific model for each image resolution which is inefficient in computing. In this work, we proposed a novel method called Meta-QSM to firstly solve QSM reconstruction of arbitrary image resolution with a single model. In Meta-QSM, weight prediction was used to predict the weights of kernels by taking the image resolution as input. The proposed method was evaluated on synthetic data and clinical data with comparison to existing QSM reconstruction methods. The experimental results showed the Meta-QSM can effectively reconstruct susceptibility maps with different image resolution using one neural network training.
△ Less
Submitted 1 August, 2019;
originally announced August 2019.
-
Deep Quantitative Susceptibility Map** for Background Field Removal and Total Field Inversion
Authors:
Juan Liu,
Kevin M. Koch
Abstract:
Quantitative susceptibility map** (QSM) utilizes MRI signal phase to estimate local tissue susceptibility, which has been shown useful to provide novel image contrast and as biomarkers of abnormal tissue. QSM requires addressing a challenging post-processing problem: filtering of image phase estimates and inversion of the phase to susceptibility relationship. A wide variety of quantification err…
▽ More
Quantitative susceptibility map** (QSM) utilizes MRI signal phase to estimate local tissue susceptibility, which has been shown useful to provide novel image contrast and as biomarkers of abnormal tissue. QSM requires addressing a challenging post-processing problem: filtering of image phase estimates and inversion of the phase to susceptibility relationship. A wide variety of quantification errors, robustness limitations, and artifacts constraints QSM clinical translation. To overcome these limitations, a robust deep-learning-based QSM reconstruction approach is proposed to perform background field removal and susceptibility inversion simultaneously from input MRI phase images. Synthetic training data based on in-vivo data sources and physics simulations were used for training. The network was quantitatively tested using gold-standard in-silico labeled dataset against established background field removal and QSM inversion approaches. In addition, the algorithm was applied to a QSM challenge data and clinical susceptibility-weighted imaging (SWI) data. When quantitatively compared against gold-standard in-silico labels, the proposed algorithm outperformed the existing comparable background field removal approaches and QSM reconstruction algorithms. The QSM challenge data and clinical SWI data demonstrated that the proposed approach was able to robustly generate high quality local field and QSM with improved accuracy.
△ Less
Submitted 28 May, 2019;
originally announced May 2019.
-
MRI Tissue Magnetism Quantification through Total Field Inversion with Deep Neural Networks
Authors:
Juan Liu,
Kevin M. Koch
Abstract:
Quantitative susceptibility map** (QSM) utilizes MRI signal phase to infer estimates of local tissue magnetism (magnetic susceptibility), which has been shown useful to provide novel image contrast and as biomarkers of abnormal tissue. QSM requires addressing a challenging post-processing problem: filtering of image phase estimates and inversion of the phase to susceptibility relationship. A wid…
▽ More
Quantitative susceptibility map** (QSM) utilizes MRI signal phase to infer estimates of local tissue magnetism (magnetic susceptibility), which has been shown useful to provide novel image contrast and as biomarkers of abnormal tissue. QSM requires addressing a challenging post-processing problem: filtering of image phase estimates and inversion of the phase to susceptibility relationship. A wide variety of quantification errors, robustness limitations, and artifacts plague QSM algorithms. To overcome these limitations, a robust deep-learning-based single-step QSM reconstruction approach is proposed and demonstrated. This neural network was trained using magnetostatic physics simulations based on in-vivo data sources. Random perturbations were added to the physics simulations to provide sufficient input-label pairs for the training purposes. The network was quantitatively tested using gold-standard in-silico labeled datasets against established QSM total field inversion approaches. In addition, the algorithm was applied to susceptibility-weighted imaging (SWI) data collected on a cohort of clinical subjects with brain hemmhorage. When quantitatively compared against gold-standard in-silico labels, the proposed algorithm outperformed the existing comparable approaches. High quality QSM were consistently estimated from clinical susceptibility-weighted data on 100 subjects without any noticeable inversion failures. The proposed approach was able to robustly generate high quality QSM with improved accuracy in in-silico gold-standard experiments. QSM produced by the proposed method can be generated in real-time on existing MRI scanner platforms and provide enhanced visualization and quantification of magnetism-based tissue contrasts.
△ Less
Submitted 11 April, 2019;
originally announced April 2019.
-
Non-locally Encoder-Decoder Convolutional Network for Whole Brain QSM Inversion
Authors:
Juan Liu,
Kevin M. Koch
Abstract:
Quantitative Susceptibility Map** (QSM) reconstruction is a challenging inverse problem driven by ill conditioning of its field-to -susceptibility transformation. State-of-art QSM reconstruction methods either suffer from image artifacts or long computation times, which limits QSM clinical translation efforts. To overcome these limitations, a non-locally encoder-decoder gated convolutional neura…
▽ More
Quantitative Susceptibility Map** (QSM) reconstruction is a challenging inverse problem driven by ill conditioning of its field-to -susceptibility transformation. State-of-art QSM reconstruction methods either suffer from image artifacts or long computation times, which limits QSM clinical translation efforts. To overcome these limitations, a non-locally encoder-decoder gated convolutional neural network is trained to infer whole brain susceptibility map, using the local field and brain mask as the inputs. The performance of the proposed method is evaluated relative to synthetic data, a publicly available challenge dataset, and clinical datasets. The proposed approach can outperform existing methods on quantitative metrics and visual assessment of image sharpness and streaking artifacts. The estimated susceptibility maps can preserve conspicuity of fine features and suppress streaking artifacts. The demonstrated methods have potential value in advancing QSM clinical research and aiding in the translation of QSM to clinical operations.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
Quantitative Susceptibility Inversion Through Parcellated Multiresolution Neural Networks and K-Space Substitution
Authors:
Juan Liu,
Andrew S. Nencka,
L. Tugan Muftuler,
Brad Swearingen,
Robin Karr,
Kevin M. Koch
Abstract:
Purpose: Quantitative Susceptibility Map** (QSM) reconstruction is a challenging inverse problem driven by poor conditioning of the field to susceptibility transformation. State-of-art QSM reconstruction methods either suffer from image artifacts or long computation times, which limits QSM clinical translation efforts. To overcome these limitations, a deep-learning-based approach is proposed and…
▽ More
Purpose: Quantitative Susceptibility Map** (QSM) reconstruction is a challenging inverse problem driven by poor conditioning of the field to susceptibility transformation. State-of-art QSM reconstruction methods either suffer from image artifacts or long computation times, which limits QSM clinical translation efforts. To overcome these limitations, a deep-learning-based approach is proposed and demonstrated. Methods: An encoder-decoder neural network was trained to infer susceptibility maps on volume parcellated regions. The training data consisted of fabricated susceptibility distributions modeled to mimic the spatial frequency patterns of in-vivo brain susceptibility distributions. Inferred volume parcels were recombined to form composite QSM. This approach is denoted as ASPEN, standing for Approximated Susceptibility through Parcellated Encoder-decoder Networks. ASPEN performance was evaluated relative to several well-established approaches on a gold-standard challenge dataset and on cohort of 200 study subjects. Results: ASPEN provided similar levels of quantitative accuracy compared to the evaluated established approaches on the gold standard ISMRM Challenge dataset, but qualitatively showed marked reductions in streaking artifacts and map blurring. On the large-cohort dataset, ASPEN achieved the highest score compared with other methods in a multi-rater evaluation of streaking artifacts and map resolution. Conclusion: The proposed ASPEN approach can robustly infer susceptibility maps in near real-time on routine computational hardware. This preliminary study establishes ASPEN's parity with existing approaches for quantitative accuracy on a well-curated gold standard dataset and further demonstrates its robustness to streaking artifacts across a large cohort of subjects.
△ Less
Submitted 12 March, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Disordered Anderson Localization Optical Fibers for Image Transport - A Review
Authors:
Arash Mafi,
John Ballato,
Karl W. Koch,
Axel Schulzgen
Abstract:
Disordered optical fibers show novel waveguiding properties, enabled by the transverse Anderson localization of light, and are used for image transport. The strong transverse scattering from the transversely disordered refractive index structure results in transversely confined modes that can freely propagate in the longitudinal direction. In some sense, an Anderson localization disordered fiber b…
▽ More
Disordered optical fibers show novel waveguiding properties, enabled by the transverse Anderson localization of light, and are used for image transport. The strong transverse scattering from the transversely disordered refractive index structure results in transversely confined modes that can freely propagate in the longitudinal direction. In some sense, an Anderson localization disordered fiber behave like a large-core multimode optical fiber, with the advantage, that most modes are highly localized in the transverse plane, so any point in the cross section of the fiber can be used for localized beam transport. This property has been used for high-quality transportation of intensity patterns and images in these optical fibers. This review covers the basics and the history of the transverse Anderson localization in disordered optical fibers and captures the recent progress in imaging applications using these optical fibers.
△ Less
Submitted 1 February, 2019;
originally announced February 2019.
-
Build-A-FLAIR: Synthetic T2-FLAIR Contrast Generation through Physics Informed Deep Learning
Authors:
Andrew S. Nencka,
Andrew Klein,
Kevin M. Koch,
Sean D. McGarry,
Peter S. LaViolette,
Eric S. Paulson,
Nikolai J. Mickevicius,
L. Tugan Muftuler,
Brad Swearingen,
Michael A. McCrea
Abstract:
Purpose: Magnetic resonance imaging (MRI) exams include multiple series with varying contrast and redundant information. For instance, T2-FLAIR contrast is based upon tissue T2 decay and the presence of water, also present in T2- and diffusion-weighted contrasts. T2-FLAIR contrast can be hypothetically modeled through deep learning models trained with diffusion- and T2-weighted acquisitions.
Met…
▽ More
Purpose: Magnetic resonance imaging (MRI) exams include multiple series with varying contrast and redundant information. For instance, T2-FLAIR contrast is based upon tissue T2 decay and the presence of water, also present in T2- and diffusion-weighted contrasts. T2-FLAIR contrast can be hypothetically modeled through deep learning models trained with diffusion- and T2-weighted acquisitions.
Methods: Diffusion-, T2-, T2-FLAIR-, and T1-weighted brain images were acquired in 15 individuals. A convolutional neural network was developed to generate a T2-FLAIR image from other contrasts. Two datasets were withheld from training for validation.
Results: Inputs with physical relationships to T2-FLAIR contrast most significantly impacted performance. The best model yielded results similar to acquired T2-FLAIR images, with a structural similarity index of 0.909, and reproduced pathology excluded from training. Synthetic images qualitatively exhibited lower noise and increased smoothness compared to acquired images.
Conclusion: This suggests that with optimal inputs, deep learning based contrast generation performs well with creating synthetic T2-FLAIR images. Feature engineering on neural network inputs, based upon the physical basis of contrast, impacts the generation of synthetic contrast images. A larger, prospective clinical study is needed.
△ Less
Submitted 15 January, 2019;
originally announced January 2019.
-
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban
, et al. (62 additional authors not shown)
Abstract:
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background…
▽ More
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (60 additional authors not shown)
Abstract:
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six…
▽ More
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
△ Less
Submitted 3 February, 2015; v1 submitted 10 September, 2014;
originally announced September 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.
-
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (55 additional authors not shown)
Abstract:
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll…
▽ More
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
△ Less
Submitted 20 December, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
Image transport through a disordered optical fiber mediated by transverse Anderson localization
Authors:
Salman Karbasi,
Ryan J. Frazier,
Karl W. Koch,
Thomas Hawkins,
John Ballato,
Arash Mafi
Abstract:
Transverse Anderson localization of light allows localized optical-beam-transport through a transversely-disordered and longitudinally-invariant medium. Its successful implementation in disordered optical fibers recently resulted in the propagation of localized beams of radii comparable with that of conventional optical fibers. We present what is, to the best of our knowledge, the first demonstrat…
▽ More
Transverse Anderson localization of light allows localized optical-beam-transport through a transversely-disordered and longitudinally-invariant medium. Its successful implementation in disordered optical fibers recently resulted in the propagation of localized beams of radii comparable with that of conventional optical fibers. We present what is, to the best of our knowledge, the first demonstration of optical image transport using transverse Anderson localization of light. The image transport quality obtained in the polymer disordered optical fiber is comparable with or better than some of the best commercially available multicore image fibers with less pixelation and higher contrast. It is argued that considerable improvement in image transport quality can be obtained in a disordered fiber made from a glass matrix with near wavelength-size randomly distributed air-holes with an air-hole fill-fraction of $50\%$. Our results open the way to device-level implementation of the transverse Anderson localization of light with potential applications in biological and medical imaging.
△ Less
Submitted 12 December, 2013; v1 submitted 16 July, 2013;
originally announced July 2013.
-
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
E. Do Couto E Silva,
T. Doughty,
L. Esteban,
S. Fallows,
E. Figueroa-Feliciano
, et al. (66 additional authors not shown)
Abstract:
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste…
▽ More
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
△ Less
Submitted 4 October, 2013; v1 submitted 10 May, 2013;
originally announced May 2013.
-
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
E. Do Couto E Silva
, et al. (66 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206P…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
△ Less
Submitted 11 October, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
A modal perspective on the transverse Anderson localization of light in disordered optical lattices
Authors:
Salman Karbasi,
Karl W. Koch,
Arash Mafi
Abstract:
We frame the transverse Anderson localization of light in a one-dimensional disordered optical lattice in the language of localized propagating eigenmodes. The modal analysis allows us to explore localization behavior of a disordered lattice independent of the properties of the external excitation. Various localization-related phenomena, such as the periodic revival of a propagating Anderson-local…
▽ More
We frame the transverse Anderson localization of light in a one-dimensional disordered optical lattice in the language of localized propagating eigenmodes. The modal analysis allows us to explore localization behavior of a disordered lattice independent of the properties of the external excitation. Various localization-related phenomena, such as the periodic revival of a propagating Anderson-localized beam are easily explained in modal language. We characterize the localization strength by the average width of the guided modes and carry out a detailed analysis of localization behavior as a function of the optical and geometrical parameters of the disordered lattice. We also show that in order to obtain a minimum average mode width, the average width of the individual random sites in the disordered lattice must be larger than the wavelength of the light by approximately a factor of two or more, and the optimum site width for the maximum localization depends on the design parameters of the disordered lattice.
△ Less
Submitted 10 January, 2013;
originally announced January 2013.
-
Multiple-beam Propagation in an Anderson Localized Optical Fiber
Authors:
Salman Karbasi,
Karl W. Koch,
Arash Mafi
Abstract:
We investigate the simultaneous propagation of multiple beams in a disordered Anderson localized optical fiber. The profiles of each beam fall off exponentially, enabling multiple channels at high-density. We examine the influence of fiber bends on the movement of the beam positions, which we refer to as drift. We investigate the extent of the drift of localized beams induced by macro-bending and…
▽ More
We investigate the simultaneous propagation of multiple beams in a disordered Anderson localized optical fiber. The profiles of each beam fall off exponentially, enabling multiple channels at high-density. We examine the influence of fiber bends on the movement of the beam positions, which we refer to as drift. We investigate the extent of the drift of localized beams induced by macro-bending and show that it is possible to design Anderson localized optical fibers that can be used for practical beam-multiplexing applications.
△ Less
Submitted 4 January, 2013; v1 submitted 19 November, 2012;
originally announced November 2012.
-
Electron penetration in the nucleus and its effect on the quadrupole interaction
Authors:
Katrin Koch,
Klaus Koepernik,
Dimitri Van Neck,
Helge Rosner,
Stefaan Cottenier
Abstract:
A series expansion of the interaction between a nucleus and its surrounding electron distribution provides terms that are well-known in the study of hyperfine interactions: the familiar quadrupole interaction and the less familiar hexadecapole interaction. If the penetration of electrons into the nucleus is taken into account, various corrections to these multipole interactions appear. The best…
▽ More
A series expansion of the interaction between a nucleus and its surrounding electron distribution provides terms that are well-known in the study of hyperfine interactions: the familiar quadrupole interaction and the less familiar hexadecapole interaction. If the penetration of electrons into the nucleus is taken into account, various corrections to these multipole interactions appear. The best known one is a scalar correction related to the isotope shift and the isomer shift. This paper discusses a related tensor correction, which modifies the quadrupole interaction if electrons penetrate the nucleus: the quadrupole shift. We describe the mathematical formalism and provide first-principles calculations of the quadrupole shift for a large set of solids. Fully relativistic calculations that explicitly take a finite nucleus into account turn out to be mandatory. Our analysis shows that the quadrupole shift becomes appreciably large for heavy elements. Implications for experimental high-precision studies of quadrupole interactions and quadrupole moment ratios are discussed. A literature review of other small quadrupole-like effects is presented as well.
△ Less
Submitted 28 August, 2009;
originally announced August 2009.