-
A framework for experimental-data-driven assessment of Magnetized Liner Inertial Fusion stagnation image metrics
Authors:
William E. Lewis,
Eric C. Harding,
David A. Yager-Elorriaga,
Jeffrey R. Fein,
Patrick F. Knapp,
Kristian Beckwith,
David J. Ampleford
Abstract:
A variety of spherical crystal x-ray imager (SCXI) diagnostics have been developed and fielded on Magnetized Liner Inertial Fusion (MagLIF) experiments at the Sandia National Laboratories Z-facility. These different imaging modalities provide detailed insight into different physical phenomena such as mix of liner material into the hot fuel, cold liner emission, or reduce impact of liner opacity. H…
▽ More
A variety of spherical crystal x-ray imager (SCXI) diagnostics have been developed and fielded on Magnetized Liner Inertial Fusion (MagLIF) experiments at the Sandia National Laboratories Z-facility. These different imaging modalities provide detailed insight into different physical phenomena such as mix of liner material into the hot fuel, cold liner emission, or reduce impact of liner opacity. However, several practical considerations ranging from the lack of a consistent spatial fiducial for registration to different point-spread-functions and tuning crystals or using filters to highlight specific spectral regions make it difficult to develop broadly applicable metrics to compare experiments across our stagnation image database without making significant unverified assumptions. We leverage experimental data for a model-free assessment of sensitivities to instrumentation-based features for any specified image metric. In particular, we utilize a database of historical and recent MagLIF data including $N_{\text{scans}} = 139$ image plate scans gathered across $N_{\text{exp}} = 67$ different experiments to assess the impact of a variety of features in the experimental observations arising from uncertainties in registration as well as discrepancies in signal-to-noise ratio and instrument resolution. We choose a wavelet-based image metric known as the Mallat Scattering Transform for the study and highlight how alternate metric choices could also be studied. In particular, we demonstrate a capability to understand and mitigate the impact of signal-to-noise, image registration, and resolution difference between images. This is achieved by utilizing multiple scans of the same image plate, sampling random translations and rotations, and applying instrument specific point-spread-functions found by ray tracing to high-resolution datasets, augmenting our data in an effectively model-free fashion.
△ Less
Submitted 27 March, 2023;
originally announced March 2023.
-
Exploring the parameter space of MagLIF implosions using similarity scaling. II. Current scaling
Authors:
D. E. Ruiz,
P. F. Schmit,
D. A. Yager-Elorriaga,
M. R. Gomez,
M. R. Weis,
C. A. Jennings,
A. J. Harvey-Thompson,
P. F. Knapp,
S. A. Slutz,
D. J. Ampleford,
K. Beckwith,
M. K. Matzen
Abstract:
Magnetized Liner Inertial Fusion (MagLIF) is a magneto-inertial-fusion (MIF) concept, which is presently being studied on the Z Pulsed Power Facility. The MagLIF platform has achieved interesting plasma conditions at stagnation and produced significant fusion yields in the laboratory. Given the relative success of MagLIF, there is a strong interest to scale the platform to higher peak currents. Ho…
▽ More
Magnetized Liner Inertial Fusion (MagLIF) is a magneto-inertial-fusion (MIF) concept, which is presently being studied on the Z Pulsed Power Facility. The MagLIF platform has achieved interesting plasma conditions at stagnation and produced significant fusion yields in the laboratory. Given the relative success of MagLIF, there is a strong interest to scale the platform to higher peak currents. However, scaling MagLIF is not entirely straightforward due to the large dimensionality of the experimental input parameter space and the large number of distinct physical processes involved in MIF implosions. In this work, we propose a novel method to scale MagLIF loads to higher currents. Our method is based on similarity (or similitude) scaling and attempts to preserve much of the physics regimes already known or being studied on today's Z pulsed-power driver. By avoiding significant deviations into unexplored and/or less well-understood regimes, the risk of unexpected outcomes on future scaled-up experiments is reduced. Using arguments based on similarity scaling, we derive the scaling rules for the experimental input parameters characterizing a MagLIF load (as functions of the characteristic current driving the implosion). We then test the estimated scaling laws for various metrics measuring performance against results of 2D radiation--magneto-hydrodynamic HYDRA simulations. Agreement is found between the scaling theory and the simulation results.
△ Less
Submitted 4 January, 2023; v1 submitted 29 September, 2022;
originally announced September 2022.
-
The data-driven future of high energy density physics
Authors:
Peter W. Hatfield,
Jim A. Gaffney,
Gemma J. Anderson,
Suzanne Ali,
Luca Antonelli,
Suzan Başeğmez du Pree,
Jonathan Citrin,
Marta Fajardo,
Patrick Knapp,
Brendan Kettle,
Bogdan Kustowski,
Michael J. MacDonald,
Derek Mariscal,
Madison E. Martin,
Taisuke Nagayama,
Charlotte A. J. Palmer,
J. Luc Peterson,
Steven Rose,
J J Ruby,
Carl Shneider,
Matt J. V. Streeter,
Will Trickey,
Ben Williams
Abstract:
The study of plasma physics under conditions of extreme temperatures, densities and electromagnetic field strengths is significant for our understanding of astrophysics, nuclear fusion and fundamental physics. These extreme physical systems are strongly non-linear and very difficult to understand theoretically or optimize experimentally. Here, we argue that machine learning models and data-driven…
▽ More
The study of plasma physics under conditions of extreme temperatures, densities and electromagnetic field strengths is significant for our understanding of astrophysics, nuclear fusion and fundamental physics. These extreme physical systems are strongly non-linear and very difficult to understand theoretically or optimize experimentally. Here, we argue that machine learning models and data-driven methods are in the process of resha** our exploration of these extreme systems that have hitherto proven far too non-linear for human researchers. From a fundamental perspective, our understanding can be helped by the way in which machine learning models can rapidly discover complex interactions in large data sets. From a practical point of view, the newest generation of extreme physics facilities can perform experiments multiple times a second (as opposed to ~daily), moving away from human-based control towards automatic control based on real-time interpretation of diagnostic data and updates of the physics model. To make the most of these emerging opportunities, we advance proposals for the community in terms of research design, training, best practices, and support for synthetic diagnostics and data analysis.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
Quantification of MagLIF morphology using the Mallat Scattering Transformation
Authors:
Michael E. Glinsky,
Thomas W. Moore,
William E. Lewis,
Matthew R. Weis,
Christopher A. Jennings,
David J. Ampleford,
Patrick F. Knapp,
Eric C. Harding,
Matthew R. Gomez,
Adam J. Harvey-Thompson
Abstract:
The morphology of the stagnated plasma resulting from Magnetized Liner Inertial Fusion (MagLIF) is measured by imaging the self-emission x-rays coming from the multi-keV plasma. Equivalent diagnostic response can be generated by integrated radiation-magnetohydrodynamic (rad-MHD) simulations from programs such as HYDRA and GORGON. There have been only limited quantitative ways to compare the image…
▽ More
The morphology of the stagnated plasma resulting from Magnetized Liner Inertial Fusion (MagLIF) is measured by imaging the self-emission x-rays coming from the multi-keV plasma. Equivalent diagnostic response can be generated by integrated radiation-magnetohydrodynamic (rad-MHD) simulations from programs such as HYDRA and GORGON. There have been only limited quantitative ways to compare the image morphology, that is the texture, of simulations and experiments. We have developed a metric of image morphology based on the Mallat Scattering Transformation (MST), a transformation that has proved to be effective at distinguishing textures, sounds, and written characters. This metric is designed, demonstrated, and refined by classifying ensembles (i.e., classes) of synthetic stagnation images, and by regressing an ensemble of synthetic stagnation images to the morphology (i.e., model) parameters used to generate the synthetic images. We use this metric to quantitatively compare simulations to experimental images, experimental images to each other, and to estimate the morphological parameters of the experimental images with uncertainty. This coordinate space has proved very adept at doing a sophisticated relative background subtraction in the MST space. This was needed to compare the experimental self emission images to the rad-MHD simulation images.
△ Less
Submitted 15 October, 2020; v1 submitted 13 April, 2020;
originally announced May 2020.
-
Quantification of MagLIF morphology using the Mallat Scattering Transformation
Authors:
Michael E. Glinsky,
Thomas W. Moore,
William E. Lewis,
Matthew R. Weis,
Christopher A. Jennings,
David A. Ampleford,
Eric C. Harding,
Patrick F. Knapp,
Matthew. R. Gomez,
Sophia E. Lussiez
Abstract:
The morphology of the stagnated plasma resulting from Magnetized Liner Inertial Fusion (MagLIF) is measured by imaging the self-emission x-rays coming from the multi-keV plasma, and the evolution of the imploding liner is measured by radiographs. Equivalent diagnostic response can be derived from integrated rad-MHD simulations from programs such as Hydra and Gorgon. There have been only limited qu…
▽ More
The morphology of the stagnated plasma resulting from Magnetized Liner Inertial Fusion (MagLIF) is measured by imaging the self-emission x-rays coming from the multi-keV plasma, and the evolution of the imploding liner is measured by radiographs. Equivalent diagnostic response can be derived from integrated rad-MHD simulations from programs such as Hydra and Gorgon. There have been only limited quantitative ways to compare the image morphology, that is the texture, of simulations and experiments. We have developed a metric of image morphology based on the Mallat Scattering Transformation (MST), a transformation that has proved to be effective at distinguishing textures, sounds, and written characters. This metric has demonstrated excellent performance in classifying ensembles of synthetic stagnation images. We use this metric to quantitatively compare simulations to experimental images, cross experimental images, and to estimate the parameters of the images with uncertainty via a linear regression of the synthetic images to the parameters used to generate them. This coordinate space has proved very adept at doing a sophisticated relative background subtraction in the MST space. This was needed to compare the experimental self emission images to the rad-MHD simulation images. We have also developed theory that connects the transformation to the causal dynamics of physical systems. This has been done from the classical kinetic perspective and from the field theory perspective, where the MST is the generalized Green's function, or S-matrix of the field theory in the scale basis. From both perspectives the first order MST is the current state of the system, and the second order MST are the transition rates from one state to another. An efficient, GPU accelerated, Python implementation of the MST was developed. Future applications are discussed.
△ Less
Submitted 14 February, 2024; v1 submitted 1 November, 2019;
originally announced November 2019.
-
Exploring magnetized liner inertial fusion with a semi-analytic model
Authors:
R. D. McBride,
S. A. Slutz,
R. A. Vesey,
M. R. Gomez,
A. B. Sefkow,
S. B. Hansen,
P. F. Knapp,
P. F. Schmit,
M. Geissel,
A. J. Harvey-Thompson,
C. A. Jennings,
E. C. Harding,
T. J. Awe,
D. C. Rovang,
K. D. Hahn,
M. R. Martin,
K. R. Cochrane,
K. J. Peterson,
G. A. Rochau,
J. L. Porter,
W. A. Stygar,
E. M. Campbell,
C. W. Nakhleh,
M. C. Herrmann,
M. E. Cuneo
, et al. (1 additional authors not shown)
Abstract:
In this paper, we explore magnetized liner inertial fusion (MagLIF) [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] using a semi-analytic model [R. D. McBride and S. A. Slutz, Phys. Plasmas 22, 052708 (2015)]. Specifically, we present simulation results from this model that: (a) illustrate the parameter space, energetics, and overall system efficiencies of MagLIF; (b) demonstrate the depende…
▽ More
In this paper, we explore magnetized liner inertial fusion (MagLIF) [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] using a semi-analytic model [R. D. McBride and S. A. Slutz, Phys. Plasmas 22, 052708 (2015)]. Specifically, we present simulation results from this model that: (a) illustrate the parameter space, energetics, and overall system efficiencies of MagLIF; (b) demonstrate the dependence of radiative loss rates on the radial fraction of the fuel that is preheated; (c) explore some of the recent experimental results of the MagLIF program at Sandia National Laboratories [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)]; (d) highlight the experimental challenges presently facing the MagLIF program; and (e) demonstrate how increases to the preheat energy, fuel density, axial magnetic field, and drive current could affect future MagLIF performance.
△ Less
Submitted 13 January, 2016; v1 submitted 25 November, 2015;
originally announced November 2015.