Performance of the GridPix detector quad
Authors:
Cornelis Ligtenberg,
Yevgen Bilevych,
Klaus Desch,
Harry van der Graaf,
Markus Gruber,
Fred Hartjes,
Kevin Heijhoff,
Jochen Kaminski,
Peter M. Kluit,
Naomi van der Kolk,
Gerhard Raven,
Tobias Schiffer,
Jan Timmermans
Abstract:
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation elec…
▽ More
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation electrons, which enable to make a precise track position measurement. A quad module was installed in a small time projection chamber and measurements of 2.5 GeV electrons were performed at the ELSA accelerator in Bonn, where a silicon telescope was used to provide a reference track. The error on the track position measurement, both in the pixel plane and drift direction, is dominated by diffusion. The quad was designed to have minimum electrical field inhomogeneities and distortions, achieving systematics of better than 13 $μ$m in the pixel plane. The resolution of the setup is 41 $μ$m, where the total systematic error of the quad detector is 24 $μ$m.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
Performance of a GridPix TPC readout based on the Timepix3 chip
Authors:
C. Ligtenberg,
K. Heijhoff,
Y. Bilevych,
K. Desch,
H. van der Graaf,
M. Gruber,
F. Hartjes,
J. Kaminski,
N. van der Kolk,
P. M. Kluit,
G. Raven,
L. Scharenberg,
T. Schiffer,
S. Schmidt,
J. Timmermans
Abstract:
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the reado…
▽ More
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the readout plane is dominated by diffusion. Systematic uncertainties are limited to below 10 $μ$m. The GridPix can detect single ionization electrons with high efficiency, which allows for energy loss measurements and particle identification. From a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m. Using the same type of chips, a Quad module was developed that can be tiled to cover a TPC readout plane at the ILC. Simulation studies show that a pixel readout can improve the momentum resolution of a TPC at the ILC by about 20%.
△ Less
Submitted 5 February, 2019;
originally announced February 2019.
-
Performance of a GridPix detector based on the Timepix3 chip
Authors:
C. Ligtenberg,
K. Heijhoff,
Y. Bilevych,
K. Desch,
H. van der Graaf,
F. Hartjes,
J. Kaminski,
P. M. Kluit,
G. Raven,
T. Schiffer,
J. Timmermans
Abstract:
A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification grid. Its performance is studied in a test beam with 2.5 GeV electrons. The GridPix detector detects single ionization electrons with high efficiency. The Timepix…
▽ More
A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification grid. Its performance is studied in a test beam with 2.5 GeV electrons. The GridPix detector detects single ionization electrons with high efficiency. The Timepix3 chip allowed for high sample rates and time walk corrections. Diffusion is found to be the dominating error on the track position measurement both in the pixel plane and in the drift direction, and systematic distortions in the pixel plane are below 10 $μ$m. Using a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m.
△ Less
Submitted 22 August, 2018; v1 submitted 14 August, 2018;
originally announced August 2018.