A high-performance reconstruction method for partially coherent ptychography
Authors:
Wenhui Xu,
Shoucong Ning,
Pengju Sheng,
Huixiang Lin,
Angus I Kirkland,
Yong Peng,
Fucai Zhang
Abstract:
Ptychography is now integrated as a tool in mainstream microscopy allowing quantitative and high-resolution imaging capabilities over a wide field of view. However, its ultimate performance is inevitably limited by the available coherent flux when implemented using electrons or laboratory X-ray sources. We present a universal reconstruction algorithm with high tolerance to low coherence for both f…
▽ More
Ptychography is now integrated as a tool in mainstream microscopy allowing quantitative and high-resolution imaging capabilities over a wide field of view. However, its ultimate performance is inevitably limited by the available coherent flux when implemented using electrons or laboratory X-ray sources. We present a universal reconstruction algorithm with high tolerance to low coherence for both far-field and near-field ptychography. The approach is practical for partial temporal and spatial coherence and requires no prior knowledge of the source properties. Our initial visible-light and electron data show that the method can dramatically improve the reconstruction quality and accelerate the convergence rate of the reconstruction. The approach also integrates well into existing ptychographic engines. It can also improve mixed-state and numerical monochromatisation methods, requiring a smaller number of coherent modes or lower dimensionality of Krylov subspace while providing more stable and faster convergence. We propose that this approach could have significant impact on ptychography of weakly scattering samples.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Multi-Convergence-Angle Ptychography with Simultaneous Strong Contrast and High Resolution
Authors:
Wei Mao,
Weiyang Zhang,
Chen Huang,
Liqi Zhou,
Judy. S. Kim,
Si Gao,
Yu Lei,
Xiaopeng Wu,
Yiming Hu,
Xudong Pei,
Weina Fang,
Xiaoguo Liu,
**gdong Song,
Chunhai Fan,
Yuefeng Nie,
Angus. I. Kirkland,
Peng Wang
Abstract:
Advances in bioimaging methods and hardware facilities have revolutionised the determination of numerous biological structures at atomic or near-atomic resolution. Among these developments, electron ptychography has recently attracted considerable attention because of its superior resolution, remarkable sensitivity to light elements, and high electron dose efficiency. Here, we introduce an innovat…
▽ More
Advances in bioimaging methods and hardware facilities have revolutionised the determination of numerous biological structures at atomic or near-atomic resolution. Among these developments, electron ptychography has recently attracted considerable attention because of its superior resolution, remarkable sensitivity to light elements, and high electron dose efficiency. Here, we introduce an innovative approach called multi-convergence-angle (MCA) ptychography, which can simultaneously enhance both contrast and resolution with continuous information transfer across a wide spectrum of spatial frequency. Our work provides feasibility of future applications of MCA-ptychography in providing high-quality two-dimensional images as input to three-dimensional reconstruction methods, thereby facilitating more accurate determination of biological structures.
△ Less
Submitted 25 March, 2024;
originally announced March 2024.
-
Calibrating coordinate system alignment in a scanning transmission electron microscope using a digital twin
Authors:
Dieter Weber,
David Landers,
Chen Huang,
Emanuela Liberti,
Emiliya Poghosyan,
Matthew Bryan,
Alexander Clausen,
Daniel G. Stroppa,
Angus I. Kirkland,
Elisabeth Müller,
Andrew Stewart,
Rafal E. Dunin-Borkowski
Abstract:
In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured that the scan coordinate system of the beam is correctly calibrated relative to the detector coordinate system. Various simplified and approximate models are use…
▽ More
In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured that the scan coordinate system of the beam is correctly calibrated relative to the detector coordinate system. Various simplified and approximate models are used implicitly and explicitly for understanding and analyzing the recorded data, requiring translation between the physical reality of the instrument and the abstractions used in data interpretation. Here, we introduce a calibration method where interactive live data processing in combination with a digital twin is used to match a set of models and their parameters with the action of a real-world instrument.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.
-
The Potential of Subsampling and Inpainting for Fast Low-Dose Cryo FIB-SEM Imaging and Tomography
Authors:
Daniel Nicholls,
Maryna Kobylysnka,
Jack Wells,
Zoe Broad,
Alex W. Robinson,
Damien McGrouther,
Amirafshar Moshtaghpour,
Angus I. Kirkland,
Roland A. Fleck,
Nigel D. Browning
Abstract:
Traditional image acquisition for cryo focused ion-beam scanning electron microscopy tomography often sees thousands of images being captured over a period of many hours, with immense data sets being produced. When imaging beam sensitive materials, these images are often compromised by additional constraints related to beam damage and the devitrification of the material during imaging, which rende…
▽ More
Traditional image acquisition for cryo focused ion-beam scanning electron microscopy tomography often sees thousands of images being captured over a period of many hours, with immense data sets being produced. When imaging beam sensitive materials, these images are often compromised by additional constraints related to beam damage and the devitrification of the material during imaging, which renders data acquisition both costly and unreliable. Subsampling and inpainting are proposed as solutions for both of these aspects, allowing fast and low-dose imaging to take place in the FIB-SEM without an appreciable low in image quality. In this work, experimental data is presented which validates subsampling and inpainting as a useful tool for convenient and reliable data acquisition in a FIB-SEM, with new methods of handling 3-dimensional data being employed in context of dictionary learning and inpainting algorithms using a newly developed microscope control software and data recovery algorithm.
△ Less
Submitted 27 October, 2023; v1 submitted 18 September, 2023;
originally announced September 2023.
-
Scan Coil Dynamics Simulation for Subsampled Scanning Transmission Electron Microscopy
Authors:
Daniel Nicholls,
Jack Wells,
Alex W. Robinson,
Amirafshar Moshtaghpour,
Angus I. Kirkland,
Nigel D. Browning
Abstract:
Subsampling and fast scanning in the scanning transmission electron microscope is problematic due to scan coil hysteresis - the mismatch between the actual and assumed location of the electron probe beam as a function of the history of the scan. Hysteresis limits the resolution of the microscope and can induce artefacts in our images, particularly during flyback. In this work, we aim to provide in…
▽ More
Subsampling and fast scanning in the scanning transmission electron microscope is problematic due to scan coil hysteresis - the mismatch between the actual and assumed location of the electron probe beam as a function of the history of the scan. Hysteresis limits the resolution of the microscope and can induce artefacts in our images, particularly during flyback. In this work, we aim to provide insights on the effects of hysteresis during image formation. To accomplish this, a simulation has been developed to model a scanning system as a damped double-harmonic oscillator, with the simulation being capable of managing many microscope dependant parameters to study the effect on the resultant scan trajectories. The model developed shows that the trajectory of the electron beam probe is not obvious and the relationship between scanning pattern and probe trajectory is complex.
△ Less
Submitted 17 July, 2023;
originally announced July 2023.
-
In silico Ptychography of Lithium-ion Cathode Materials from Subsampled 4-D STEM Data
Authors:
Alex W. Robinson,
Amirafshar Moshtaghpour,
Jack Wells,
Daniel Nicholls,
Zoe Broad,
Angus I. Kirkland,
Beata L. Mehdi,
Nigel D. Browning
Abstract:
High quality scanning transmission electron microscopy (STEM) data acquisition and analysis has become increasingly important due to the commercial demand for investigating the properties of complex materials such as battery cathodes; however, multidimensional techniques (such as 4-D STEM) which can improve resolution and sample information are ultimately limited by the beam-damage properties of t…
▽ More
High quality scanning transmission electron microscopy (STEM) data acquisition and analysis has become increasingly important due to the commercial demand for investigating the properties of complex materials such as battery cathodes; however, multidimensional techniques (such as 4-D STEM) which can improve resolution and sample information are ultimately limited by the beam-damage properties of the materials or the signal-to-noise ratio of the result. subsampling offers a solution to this problem by retaining high signal, but distributing the dose across the sample such that the damage can be reduced. It is for these reasons that we propose a method of subsampling for 4-D STEM, which can take advantage of the redundancy within said data to recover functionally identical results to the ground truth. We apply these ideas to a simulated 4-D STEM data set of a LiMnO2 sample and we obtained high quality reconstruction of phase images using 12.5% subsampling.
△ Less
Submitted 12 July, 2023;
originally announced July 2023.
-
Oleylamine aging of PtNi nanoparticles giving enhanced functionality for the oxygen reduction reaction
Authors:
Gerard M Leteba,
Yi-Chi Wang,
Thomas J A Slater,
Rongsheng Cai,
Conor Byrne,
Christopher P Race,
David R G Mitchell,
Pieter B J Levecque,
Neil P Young,
Alex Walton,
Angus I Kirkland,
Sarah J Haigh,
Candace I Lang
Abstract:
We report a rapid solution-phase strategy to synthesize alloyed PtNi nanoparticles which demonstrate outstanding functionality for the oxygen reduction reaction (ORR). This one-pot co-reduction colloidal synthesis results in a monodisperse population of single-crystal nanoparticles of rhombic dodecahedral morphology, with Pt enriched edges and compositions close to Pt1Ni2. We use nanoscale 3D comp…
▽ More
We report a rapid solution-phase strategy to synthesize alloyed PtNi nanoparticles which demonstrate outstanding functionality for the oxygen reduction reaction (ORR). This one-pot co-reduction colloidal synthesis results in a monodisperse population of single-crystal nanoparticles of rhombic dodecahedral morphology, with Pt enriched edges and compositions close to Pt1Ni2. We use nanoscale 3D compositional analysis to reveal for the first time that oleylamine (OAm)-aging of the rhombic dodecahedral Pt1Ni2 particles results in Ni leaching from surface facets, producing aged particles with concave faceting, an exceptionally high surface area and a composition of Pt2Ni1. We show that the modified atomic nanostructures catalytically outperform the original PtNi rhombic dodecahedral particles by more than 2-fold and also yield improved cycling durability. Their functionality for the ORR far exceeds commercially available Pt/C nanoparticle electrocatalysts, both in terms of mass-specific activities (up to a 25-fold increase) and intrinsic area-specific activities (up to a 27-fold increase).
△ Less
Submitted 26 November, 2021;
originally announced November 2021.
-
Quantifying the Performance of a Hybrid Pixel Detector with GaAs:Cr Sensor for Transmission Electron Microscopy
Authors:
Kirsty A. Paton,
Matthew C. Veale,
Xiaoke Mu,
Christopher S. Allen,
Dzmitry Maneuski,
Christian Kübel,
Val O'Shea,
Angus I. Kirkland,
Damien McGrouther
Abstract:
Hybrid pixel detectors (HPDs) have been shown to be highly effective for diffraction-based and time-resolved studies in transmission electron microscopy, but their performance is limited by the fact that high-energy electrons scatter over long distances in their thick Si sensors. An advantage of HPDs compared to monolithic active pixel sensors (MAPS) is that their sensor does not need to be fabric…
▽ More
Hybrid pixel detectors (HPDs) have been shown to be highly effective for diffraction-based and time-resolved studies in transmission electron microscopy, but their performance is limited by the fact that high-energy electrons scatter over long distances in their thick Si sensors. An advantage of HPDs compared to monolithic active pixel sensors (MAPS) is that their sensor does not need to be fabricated from Si. We have compared the performance of the Medipix3 HPD with a Si sensor and with a GaAs:Cr sensor using primary electrons in the energy range of 60 - 300keV. We describe the measurement and calculation of the detectors' modulation transfer function (MTF) and detective quantum efficiency (DQE), which show that the performance of the GaAs:Cr device is markedly superior to that of the Si device for high-energy electrons.
△ Less
Submitted 30 September, 2020;
originally announced September 2020.
-
Medipix3 Demonstration and understanding of near ideal detector performance for 60 & 80 keV electrons
Authors:
J. A. Mir,
R. Clough,
R. MacInnes,
C. Gough,
R. Plackett,
I. Shipsey,
H. Sawada,
I. MacLaren,
R. Ballabriga,
D. Maneuski,
V. O'Shea,
D. McGrouther,
A. I. Kirkland
Abstract:
In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize…
▽ More
In our article we report first quantitative measurements of imaging performance for the current generation of hybrid pixel detector, Medipix3, as direct electron detector. Utilising beam energies of 60 & 80 keV, measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) have revealed that, in single pixel mode (SPM), energy threshold values can be chosen to maximize either the MTF or DQE, obtaining values near to, or even exceeding, those for an ideal detector. We have demonstrated that the Medipix3 charge summing mode (CSM) can deliver simultaneous, near ideal values of both MTF and DQE. To understand direct detection performance further we have characterized the detector response to single electron events, building an empirical model which can predict detector MTF and DQE performance based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance, recording a fully exposed electron diffraction pattern at 24-bit depth and images in SPM and CSM modes. Taken together our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous and alternative architecture for direct electron imaging
△ Less
Submitted 26 August, 2016;
originally announced August 2016.