-
Machine Learning based tool for CMS RPC currents quality monitoring
Authors:
E. Shumka,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
K. Mota Amarilo,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov
, et al. (83 additional authors not shown)
Abstract:
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly m…
▽ More
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly monitored and the detector is regularly maintained to ensure stable operation. The main monitorable characteristics are dark current, efficiency for muon detection, noise rate etc. Herein we describe an automated tool for CMS RPC current monitoring which uses Machine Learning techniques. We further elaborate on the dedicated generalized linear model proposed already and add autoencoder models for self-consistent predictions as well as hybrid models to allow for RPC current predictions in a distant future.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.
-
RPC based tracking system at CERN GIF++ facility
Authors:
K. Mota Amarilo,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov
, et al. (83 additional authors not shown)
Abstract:
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system…
▽ More
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Performance of the Electromagnetic Pixel Calorimeter Prototype EPICAL-2
Authors:
J. Alme,
R. Barthel,
A. van Bochove,
V. Borshchov,
R. Bosley,
A. van den Brink,
E. Broeils,
H. Büsching,
V. N. Eikeland,
O. S. Groettvik,
Y. H. Han,
N. van der Kolk,
J. H. Kim,
T. J. Kim,
Y. Kwon,
M. Mager,
Q. W. Malik,
E. Okkinga,
T. Y. Park,
T. Peitzmann,
F. Pliquett,
M. Protsenko,
F. Reidt,
S. van Rijk,
K. Røed
, et al. (9 additional authors not shown)
Abstract:
The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$μ$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are…
▽ More
The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$μ$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are critical for physics studies are measured: electromagnetic shower response, energy resolution and linearity. The stochastic energy resolution is comparable with the state-of-the art resolution for a Si-W calorimeter, with data described well by a simulation model using GEANT and Allpix$^2$. The performance achieved makes this technology a good candidate for use in the ALICE FoCal upgrade, and in general demonstrates the strong potential for future applications in high-energy physics.
△ Less
Submitted 28 December, 2022; v1 submitted 6 September, 2022;
originally announced September 2022.
-
Results from the EPICAL-2 Ultra-High Granularity Electromagnetic Calorimeter Prototype
Authors:
T. Peitzmann,
J. Alme,
R. Barthel,
A. van Bochove,
V. Borshchov,
R. Bosley,
A. van den Brink,
E. Broeils,
H. Büsching,
V. N. Eikeland,
O. S. Groettvik,
Y. H. Han,
N. van der Kolk,
J. H. Kim,
T. J. Kim,
Y. Kwon,
M. Mager,
Q. W. Malik,
E. Okkinga,
T. Y. Park,
F. Pliquett,
M. Protsenko,
F. Reidt,
S. van Rijk,
K. Røed
, et al. (9 additional authors not shown)
Abstract:
A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, μ\mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and w…
▽ More
A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, μ\mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and with test beams at DESY and the CERN SPS. We report on performance results obtained at DESY, showing good energy resolution and linearity, and compare to detailed MC simulations. Also shown are preliminary results of the high-energy performance as measured at the SPS. The two-shower separation capabilities are discussed.
△ Less
Submitted 27 September, 2022; v1 submitted 5 July, 2022;
originally announced July 2022.
-
Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
Authors:
A. Samalan,
M. Tytgat,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. DaCosta,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal,
A. Cabrera
, et al. (86 additional authors not shown)
Abstract:
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solen…
▽ More
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.
△ Less
Submitted 2 November, 2021; v1 submitted 29 September, 2021;
originally announced September 2021.
-
Maximum-Entropy Revisited
Authors:
Long V. Le,
Tae J. Kim,
Young D. Kim,
D. E. Aspnes
Abstract:
For over five decades the procedure termed maximum-entropy (M-E) has been used to sharpen structure in spectra, optical and otherwise. However, this is a contradiction: by modifying data, this approach violates the fundamental M-E principle, which is to extend, in a model-independent way, trends established by low-index Fourier coefficients into the white-noise region. The Burg derivation, and ind…
▽ More
For over five decades the procedure termed maximum-entropy (M-E) has been used to sharpen structure in spectra, optical and otherwise. However, this is a contradiction: by modifying data, this approach violates the fundamental M-E principle, which is to extend, in a model-independent way, trends established by low-index Fourier coefficients into the white-noise region. The Burg derivation, and indirectly the prediction-error equations on which sharpening is based, both lead to the correct solution, although this has been consistently overlooked. For a single Lorentzian line these equations can be solved analytically. The resultant lineshape is an exact autoregressive model-1 (AR(1)) replica of the original, demonstrating how the M-E reconstruction extends low-index Fourier coefficients to the digital limit and illustrating why this approach works so well for lineshapes resulting from first-order decay processes. By simultaneously retaining low-index coefficients exactly and eliminating Gibbs oscillations, M-E noise filtering is quantitatively superior to that achieved by any linear method, including the high-performance filters recently proposed. Examples are provided.
△ Less
Submitted 9 March, 2021;
originally announced March 2021.
-
Static Rashba Effect by Surface Reconstruction and Photon Recycling in the Dynamic Indirect Gap of APbBr3 (A = Cs, CH3NH3) Single Crystals
Authors:
Hongsun Ryu,
Dae Young Park,
K. McCall,
Hye Ryung Byun,
Yongjun Lee,
Tae Jung Kim,
Mun Seok Jeong,
Jeongyong Kim,
Mercouri G. Kanatzidis,
Joon I. Jang
Abstract:
Recently, halide perovskites have gained significant attention from the perspective of efficient spintronics owing to Rashba effect. This effect occurs as a consequence of strong spin-orbit coupling under noncentrosymmetric environment, which can be dynamic and/or static. However, there exist intense debates on the origin of broken inversion symmetry since the halide perovskites typically crystall…
▽ More
Recently, halide perovskites have gained significant attention from the perspective of efficient spintronics owing to Rashba effect. This effect occurs as a consequence of strong spin-orbit coupling under noncentrosymmetric environment, which can be dynamic and/or static. However, there exist intense debates on the origin of broken inversion symmetry since the halide perovskites typically crystallize into a centrosymmetric structure. In order to clarify the issue, we examine both dynamic and static effects in the all-inorganic CsPbBr3 and organic-inorganic CH3NH3PbBr3 (MAPbBr3) perovskite single crystals by employing temperature- and polarization-dependent photoluminescence excitation spectroscopy. The perovskite single crystals manifest the dynamic effect by photon recycling in the indirect Rashba gap, causing dual peaks in the photoluminescence. But the effect vanishes in CsPbBr3 at low temperatures (< 50 K), accompanied by a striking color change of the crystal, arising presumably from lower degrees of freedom for inversion symmetry breaking associated with the thermal motion of the spherical Cs cation, compared with the polar MA cation in MAPbBr3. We also show that static Rashba effect occurs only in MAPbBr3 below 90 K due to surface reconstruction via MA-cation ordering, which likely extends across a few layers from the crystal surface to the interior. We further demonstrate that this static Rashba effect can be completely suppressed upon surface treatment with poly methyl methacrylate (PMMA) coating. We believe that our results provide a rationale for the Rashba effects in halide perovskites.
△ Less
Submitted 25 August, 2020; v1 submitted 22 July, 2020;
originally announced July 2020.
-
CMS RPC Background -- Studies and Measurements
Authors:
R. Hadjiiska,
A. Samalan,
M. Tytgat,
N. Zaganidis,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. Da Costa,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal
, et al. (84 additional authors not shown)
Abstract:
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be upd…
▽ More
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.
△ Less
Submitted 13 December, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
Overlimiting current in non-uniform arrays of microchannels
Authors:
Hyekyung Lee,
Shima Alizadeh,
Tae ** Kim,
Seung-min Park,
Hyongsok Tom Soh,
Ali Mani,
Sung Jae Kim
Abstract:
Overlimiting current (OLC) through electrolytes interfaced with perm-selective membranes has been extensively researched in recent years for understanding the fundamental mechanisms of transport and develo** efficient applications from electrochemistry to sample analysis and separation. Predominant mechanisms responsible for OLC include surface conduction, convection by electro-osmotic flow, and…
▽ More
Overlimiting current (OLC) through electrolytes interfaced with perm-selective membranes has been extensively researched in recent years for understanding the fundamental mechanisms of transport and develo** efficient applications from electrochemistry to sample analysis and separation. Predominant mechanisms responsible for OLC include surface conduction, convection by electro-osmotic flow, and electro-osmotic instability depending on input parameters such as surface charge and geometric constrictions. This work studies how a network of microchannels in a non-uniform array, which mimicks a natural pore configuration, can contribute to OLC. To this end, micro/nanofluidic devices are fabricated with arrays of parallel microchannels with non-uniform size distributions. All cases maintain the same surface and bulk conduction to allow probing the sensitivity only by the non-uniformity of the channels. Both experimental and theoretical current-voltage relations demonstrate that OLCs increase with increasing non-uniformity. Furthermore, the visualization of internal recirculating flows indicates that the non-uniform arrays induce flow loops across the network enhancing advective transport. These evidences confirm a new driving mechanism of OLC, inspired by natural micro/nanoporous materials with random geometric structure. Therefore, this result can advance not only the fundamental understanding of nanoelectrokinetics but also the design rule of engineering applications of electrochemical membrane.
△ Less
Submitted 21 October, 2019;
originally announced October 2019.
-
High Rate RPC detector for LHC
Authors:
F. Lagarde,
A. Fagot,
M. Gul,
C. Roskas,
M. Tytgat,
N. Zaganidis,
S. Fonseca De Souza,
A. Santoro,
F. Torres Da Silva De Araujo,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
D. Han,
W. Yi,
C. Avila,
A. Cabrera
, et al. (77 additional authors not shown)
Abstract:
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The…
▽ More
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\
{\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.
△ Less
Submitted 16 July, 2018;
originally announced July 2018.
-
Calculating magnetic interactions in organic electrides
Authors:
Taek Jung Kim,
Hongkee Yoon,
Myung Joon Han
Abstract:
We present our calculation results for organic magnetic electrides. In order to identify the `cavity' electrons, we use maximally-localized Wannier functions and `empty atom' technique. The estimation of magnetic coupling is then performed based on magnetic force linear response theory. Both short- and long-range magnetic interactions are calculated with a single self-consistent calculation of a p…
▽ More
We present our calculation results for organic magnetic electrides. In order to identify the `cavity' electrons, we use maximally-localized Wannier functions and `empty atom' technique. The estimation of magnetic coupling is then performed based on magnetic force linear response theory. Both short- and long-range magnetic interactions are calculated with a single self-consistent calculation of a primitive cell. With this scheme we investigate four different organic electrides whose magnetic properties have been partly unknown or under debate. Our calculation results unveil the nature of magnetic moment and their interactions, and justify or defy the validity of preassumed spin models. Our work not only provides useful insight to understand magnetic electrides but also suggests a new paradigm to study the related materials.
△ Less
Submitted 10 June, 2018; v1 submitted 14 April, 2018;
originally announced April 2018.
-
Physics Potentials with the Second Hyper-Kamiokande Detector in Korea
Authors:
Hyper-Kamiokande proto-collaboration,
:,
K. Abe,
Ke. Abe,
S. H. Ahn,
H. Aihara,
A. Aimi,
R. Akutsu,
C. Andreopoulos,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
Y. Ashida,
V. Aushev,
M. Barbi,
G. J. Barker,
G. Barr,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
L. Berns,
T. Berry,
S. Bhadra,
D. Bravo-Bergu no
, et al. (331 additional authors not shown)
Abstract:
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are sev…
▽ More
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are several candidate sites in Korea with baselines of 1,000$\sim$1,300~km and OAAs of 1$^{\textrm{o}}$$\sim$3$^{\textrm{o}}$. We conducted sensitivity studies on neutrino oscillation physics for a second detector, either in Japan (JD $\times$ 2) or Korea (JD + KD) and compared the results with a single detector in Japan. Leptonic CP violation sensitivity is improved especially when the CP is non-maximally violated. The larger matter effect at Korean candidate sites significantly enhances sensitivities to non-standard interactions of neutrinos and mass ordering determination. Current studies indicate the best sensitivity is obtained at Mt. Bisul (1,088~km baseline, $1.3^\circ$ OAA). Thanks to a larger (1,000~m) overburden than the first detector site, clear improvements to sensitivities for solar and supernova relic neutrino searches are expected.
△ Less
Submitted 26 March, 2018; v1 submitted 18 November, 2016;
originally announced November 2016.
-
Implementation of Particle Flow Algorithm and Muon Identification
Authors:
M. J. Charles,
U. Mallik,
T. J. Kim
Abstract:
We present the implementation of the Particle Flow Algorithm and the result of the muon identification developed at the University of Iowa. We use Monte Carlo samples generated for the benchmark LOI process with the Silicon Detector design at the International Linear Collider. With the muon identification, an improved jet energy resolution, good muon efficiency and purity are achieved.
We present the implementation of the Particle Flow Algorithm and the result of the muon identification developed at the University of Iowa. We use Monte Carlo samples generated for the benchmark LOI process with the Silicon Detector design at the International Linear Collider. With the muon identification, an improved jet energy resolution, good muon efficiency and purity are achieved.
△ Less
Submitted 28 January, 2009;
originally announced January 2009.