-
Projected background and sensitivity of AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (81 additional authors not shown)
Abstract:
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located ap…
▽ More
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
-
Robust electrothermal switching of optical phase change materials through computer-aided adaptive pulse optimization
Authors:
Parth Garud,
Kiumars Aryana,
Cosmin Constantin Popescu,
Steven Vitale,
Rashi Sharma,
Kathleen Richardson,
Tian Gu,
Juejun Hu,
Hyun Jung Kim
Abstract:
Electrically tunable optical devices present diverse functionalities for manipulating electromagnetic waves by leveraging elements capable of reversibly switching between different optical states. This adaptability in adjusting their responses to electromagnetic waves after fabrication is crucial for develo** more efficient and compact optical systems for a broad range of applications including…
▽ More
Electrically tunable optical devices present diverse functionalities for manipulating electromagnetic waves by leveraging elements capable of reversibly switching between different optical states. This adaptability in adjusting their responses to electromagnetic waves after fabrication is crucial for develo** more efficient and compact optical systems for a broad range of applications including sensing, imaging, telecommunications, and data storage. Chalcogenide-based phase change materials (PCMs) have shown great promise due to their stable, non-volatile phase transition between amorphous and crystalline states. Nonetheless, optimizing the switching parameters of PCM devices and maintaining their stable operation over thousands of cycles with minimal variation can be challenging. In this paper, we report on the critical role of PCM pattern as well as electrical pulse form in achieving reliable and stable switching, extending the operational lifetime of the device beyond 13,000 switching events. To achieve this, we have developed a computer-aided algorithm that monitors optical changes in the device and adjusts the applied voltage in accordance with the phase transformation process, thereby significantly enhancing the lifetime of these reconfigurable devices. Our findings reveal that patterned PCM structures show significantly higher endurance compared to blanket PCM thin films.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
Measurements of low energy nuclear recoil quenching factors for Na and I recoils in the NaI(Tl) scintillator
Authors:
S. H. Lee,
H. W. Joo,
H. J. Kim,
K. W. Kim,
S. K. Kim,
Y. D. Kim,
Y. J. Ko,
H. S. Lee,
J. Y. Lee,
H. S. Park,
Y. S. Yoon
Abstract:
Elastic scattering off nuclei in target detectors, involving interactions with dark matter and coherent elastic neutrino nuclear recoil (CE$ν$NS), results in the deposition of low energy within the nuclei, dissipating rapidly through a combination of heat and ionization. The primary energy loss mechanism for nuclear recoil is heat, leading to consistently smaller measurable scintillation signals c…
▽ More
Elastic scattering off nuclei in target detectors, involving interactions with dark matter and coherent elastic neutrino nuclear recoil (CE$ν$NS), results in the deposition of low energy within the nuclei, dissipating rapidly through a combination of heat and ionization. The primary energy loss mechanism for nuclear recoil is heat, leading to consistently smaller measurable scintillation signals compared to electron recoils of the same energy. The nuclear recoil quenching factor (QF), representing the ratio of scintillation light yield produced by nuclear recoil to that of electron recoil at the same energy, is a critical parameter for understanding dark matter and neutrino interactions with nuclei. The low energy QF of NaI(Tl) crystals, commonly employed in dark matter searches and CE$ν$NS measurements, is of substantial importance. Previous low energy QF measurements were constrained by contamination from photomultiplier tube (PMT)-induced noise, resulting in an observed light yield of approximately 15 photoelectrons per keVee (kilo-electron-volt electron-equivalent energy) and nuclear recoil energy above 5 keVnr (kilo-electron-volt nuclear recoil energy). Through enhanced crystal encapsulation, an increased light yield of around 26 photoelectrons per keVee is achieved. This improvement enables the measurement of the nuclear recoil QF for sodium nuclei at an energy of 3.8 $\pm$ 0.6 keVnr with a QF of 11.2 $\pm$ 1.7%. Furthermore, a reevaluation of previously reported QF results is conducted, incorporating enhancements in low energy events based on waveform simulation. The outcomes are generally consistent with various recent QF measurements for sodium and iodine.
△ Less
Submitted 28 February, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
Nonproportionality of NaI(Tl) Scintillation Detector for Dark Matter Search Experiments
Authors:
S. M. Lee,
G. Adhikari,
N. Carlin,
J. Y. Cho,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Fran. a,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
S. W. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (37 additional authors not shown)
Abstract:
We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced…
▽ More
We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced by decays supported by both long and short-lived isotopes. Analyzing peaks from decays supported only by short-lived isotopes presented a unique challenge due to their limited statistics and overlap** energies, which was overcome by long-term data collection and a time-dependent analysis. A key achievement is the direct measurement of the 0.87 keV light yield, resulting from the cascade following electron capture decay of $^{22}$Na from internal contamination. This measurement, previously accessible only indirectly, deepens our understanding of NaI(Tl) scintillator behavior in the region of interest for dark matter searches. This study holds substantial implications for background modeling and the interpretation of dark matter signals in NaI(Tl) experiments.
△ Less
Submitted 10 May, 2024; v1 submitted 14 January, 2024;
originally announced January 2024.
-
Observation of the Magnonic Dicke Superradiant Phase Transition
Authors:
Dasom Kim,
Sohail Dasgupta,
Xiaoxuan Ma,
Joong-Mok Park,
Hao-Tian Wei,
Liang Luo,
Jacques Doumani,
Xinwei Li,
Wanting Yang,
Di Cheng,
Richard H. J. Kim,
Henry O. Everitt,
Shojiro Kimura,
Hiroyuki Nojiri,
Jigang Wang,
Shixun Cao,
Motoaki Bamba,
Kaden R. A. Hazzard,
Junichiro Kono
Abstract:
Two-level atoms coupled with single-mode cavity photons are predicted to exhibit a quantum phase transition when the coupling strength exceeds a critical value, entering a phase in which atomic polarization and photonic field are finite even at zero temperature and without external driving. However, this phenomenon, the superradiant phase transition (SRPT), is forbidden by a no-go theorem due to t…
▽ More
Two-level atoms coupled with single-mode cavity photons are predicted to exhibit a quantum phase transition when the coupling strength exceeds a critical value, entering a phase in which atomic polarization and photonic field are finite even at zero temperature and without external driving. However, this phenomenon, the superradiant phase transition (SRPT), is forbidden by a no-go theorem due to the existence of the diamagnetic term in the Hamiltonian. Here, we present spectroscopic evidence for a magnonic SRPT in ErFeO$_3$, where the role of the photonic mode (two-level atoms) in the photonic SRPT is played by an Fe$^{3+}$ magnon mode (Er$^{3+}$ spins). The absence of the diamagnetic term in the Fe$^{3+}$-Er$^{3+}$ exchange coupling ensures that the no-go theorem does not apply. Terahertz and gigahertz magnetospectroscopy experiments revealed the signatures of the SRPT -- a kink and a softening, respectively, of two spin-magnon hybridized modes at the critical point.
△ Less
Submitted 3 January, 2024;
originally announced January 2024.
-
Electrically reconfigurable phase-change transmissive metasurface
Authors:
Cosmin Constantin Popescu,
Kiumars Aryana,
Parth Garud,
Khoi Phuong Dao,
Steven Vitale,
Vladimir Liberman,
Hyung-Bin Bae,
Tae-Woo Lee,
Myungkoo Kang,
Kathleen A. Richardson,
Carlos A. Rios Ocampo,
Yifei Zhang,
Tian Gu,
Juejun Hu,
Hyun Jung Kim
Abstract:
Programmable and reconfigurable optics hold significant potential for transforming a broad spectrum of applications, spanning space explorations to biomedical imaging, gas sensing, and optical cloaking. The ability to adjust the optical properties of components like filters, lenses, and beam steering devices could result in dramatic reductions in size, weight, and power consumption in future optoe…
▽ More
Programmable and reconfigurable optics hold significant potential for transforming a broad spectrum of applications, spanning space explorations to biomedical imaging, gas sensing, and optical cloaking. The ability to adjust the optical properties of components like filters, lenses, and beam steering devices could result in dramatic reductions in size, weight, and power consumption in future optoelectronic devices. Among the potential candidates for reconfigurable optics, chalcogenide-based phase change materials (PCMs) offer great promise due to their non-volatile and analogue switching characteristics. Although PCM have found widespread use in electronic data storage, these memory devices are deeply sub-micron-sized. To incorporate phase change materials into free-space optical components, it is essential to scale them up to beyond several hundreds of microns while maintaining reliable switching characteristics. This study demonstrated a non-mechanical, non-volatile transmissive filter based on low-loss PCMs with a 200 $μ$m$ \times $200 $μ$m switching area. The device/metafilter can be consistently switched between low- and high-transmission states using electrical pulses with a switching contrast ratio of 5.5 dB. The device was reversibly switched for 1250 cycles before accelerated degradation took place. The work represents an important step toward realizing free-space reconfigurable optics based on PCMs.
△ Less
Submitted 16 December, 2023;
originally announced December 2023.
-
Scintillation characteristics of an undoped CsI crystal at low-temperature for dark matter search
Authors:
W. K. Kim,
H. Y. Lee,
K. W. Kim,
Y. J. Ko,
J. A. Jeon,
H. J. Kim,
H. S. Lee
Abstract:
The scintillation characteristics of an undoped CsI crystal with dimensions of 5.8 mm $\times$ 5.9 mm $\times$ 7.0 mm, corresponding to a weight of 1.0 g, were studied by directly coupling two silicon photomultipliers (SiPMs) over a temperature range from room temperature (300 K) to a low temperature of 86 K. The scintillation decay time and light output were measured using x-ray (23 keV) and gamm…
▽ More
The scintillation characteristics of an undoped CsI crystal with dimensions of 5.8 mm $\times$ 5.9 mm $\times$ 7.0 mm, corresponding to a weight of 1.0 g, were studied by directly coupling two silicon photomultipliers (SiPMs) over a temperature range from room temperature (300 K) to a low temperature of 86 K. The scintillation decay time and light output were measured using x-ray (23 keV) and gamma-ray (88 keV) peaks from a $^{109}$Cd radioactive source. An increase in decay time was observed as the temperature decreased from room temperature to 86 K, ranging from 76 ns to 605 ns. Correspondingly, the light output increased as well, reaching 37.9 $\pm$ 1.5 photoelectrons per keV electron-equivalent at 86 K, which is approximately 18 times higher than the light yield at room temperature. Leveraging the significantly enhanced scintillation light output of the undpoed CsI crystal at the low temperature, coupling it with SiPMs makes it a promising candidate for the future dark matter search detector, benefiting from the low threshold owing to the high light output. The odd proton numbers from both cesium and iodine provide an advantage for the WIMP-proton spin-dependent interaction. We evaluated the sensitivity of low-mass dark matter on WIMP-proton spin-dependent interaction with the Migdal process, assuming 200 kg of undoped CsI crystals for the dark matter search. We conclude that undoped CsI crystal detectors exhibit world-competitive sensitivities for low-mass dark matter detection, particularly for the WIMP-proton spin-dependent interaction.
△ Less
Submitted 13 December, 2023;
originally announced December 2023.
-
Assembling PNIPAM-Capped Gold Nanoparticles in Aqueous Solutions
Authors:
Binay P. Nayak,
Hyeong ** Kim,
Srikanth Nayak,
Wenjie Wang,
Wei Bu,
Surya K. Mallapragada,
David Vaknin
Abstract:
Employing small angle X-ray scattering (SAXS), we explore the conditions under which the assembly of gold nanoparticles (AuNPs) grafted with the thermo-sensitive polymer Poly(N-isopropylacrylamide) (PNIPAM) emerges. We find that short-range order assembly emerges by combining the addition of electrolytes or poly-electrolytes with raising the temperature of the suspensions above the lower-critical…
▽ More
Employing small angle X-ray scattering (SAXS), we explore the conditions under which the assembly of gold nanoparticles (AuNPs) grafted with the thermo-sensitive polymer Poly(N-isopropylacrylamide) (PNIPAM) emerges. We find that short-range order assembly emerges by combining the addition of electrolytes or poly-electrolytes with raising the temperature of the suspensions above the lower-critical solution temperature (LCST) of PNIPAM. Our results show that the longer the PNIPAM chain is, the better organization in the assembled clusters. Interestingly, without added electrolytes, there is no evidence of AuNP assembly as a function of temperature, although untethered PNIPAM is known to undergo a coil-to-globule transition above its LCST. This study demonstrates another approach to assembling potential thermo-sensitive nanostructures for devices by leveraging the unique properties of PNIPAM.
△ Less
Submitted 7 December, 2023;
originally announced December 2023.
-
Alpha backgrounds in NaI(Tl) crystals of COSINE-100
Authors:
G. Adhikari,
N. Carlin,
D. F. F. S. Cavalcante,
J. Y. Cho,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
S. W. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (38 additional authors not shown)
Abstract:
COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Ca…
▽ More
COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Carlo simulation results and activity quantification of the alpha decay components of the COSINE-100 NaI(Tl) crystals. The data strongly indicate that the alpha decays probabilistically undergo two possible quenching factors but require further investigation. The fitted results are consistent with independent measurements and improve the overall understanding of the COSINE-100 backgrounds. Furthermore, the half-life of 216Po has been measured to be 143.4 +/- 1.2 ms, which is consistent with and more precise than recent measurements.
△ Less
Submitted 30 January, 2024; v1 submitted 8 November, 2023;
originally announced November 2023.
-
Versatile spaceborne photonics with chalcogenide phase-change materials
Authors:
Hyun Jung Kim,
Matthew Julian,
Calum Williams,
David Bombara,
Juejun Hu,
Tian Gu,
Kiumars Aryana,
Godfrey Sauti,
William Humphreys
Abstract:
Recent growth in space systems has seen increasing capabilities packed into smaller and lighter Earth observation and deep space mission spacecraft. Phase-change materials (PCMs) are nonvolatile, reconfigurable, fast-switching, and have recently shown a high degree of space radiation tolerance, thereby making them an attractive materials platform for spaceborne photonics applications. They promise…
▽ More
Recent growth in space systems has seen increasing capabilities packed into smaller and lighter Earth observation and deep space mission spacecraft. Phase-change materials (PCMs) are nonvolatile, reconfigurable, fast-switching, and have recently shown a high degree of space radiation tolerance, thereby making them an attractive materials platform for spaceborne photonics applications. They promise robust, lightweight, and energy-efficient reconfigurable optical systems whose functions can be dynamically defined on-demand and on orbit to deliver enhanced science or mission support in harsh environments on lean power budgets. This comment aims to discuss the recent advances in rapidly growing PCM research and its potential to transition from conventional terrestrial optoelectronics materials platforms to versatile spaceborne photonic materials platforms for current and next-generation space and science missions. Materials International Space Station Experiment-14 (MISSE-14) mission-flown PCMs outside of the International Space Station (ISS) and key results and NASA examples are highlighted to provide strong evidence of the applicability of spaceborne photonics.
△ Less
Submitted 29 October, 2023;
originally announced October 2023.
-
Highly-Sensitive Resonance-Enhanced Organic Photodetectors for Shortwave Infrared Sensing
Authors:
Hoang Mai Luong,
Chokchai Kaiyasuan,
Ahra Yi,
Sangmin Chae,
Brian Minki Kim,
Patchareepond Panoy,
Hyo Jung Kim,
Vinich Promarak,
Yasuo Miyata,
Hidenori Nakayama,
Thuc-Quyen Nguyen
Abstract:
Shortwave infrared (SWIR) has various applications, including night vision, remote sensing, and medical imaging. SWIR organic photodetectors (OPDs) offer advantages such as flexibility, cost-effectiveness, and tunable properties, however, lower sensitivity and limited spectral coverage compared to inorganic counterparts are major drawbacks. Here, we propose a simple yet effective and widely applic…
▽ More
Shortwave infrared (SWIR) has various applications, including night vision, remote sensing, and medical imaging. SWIR organic photodetectors (OPDs) offer advantages such as flexibility, cost-effectiveness, and tunable properties, however, lower sensitivity and limited spectral coverage compared to inorganic counterparts are major drawbacks. Here, we propose a simple yet effective and widely applicable strategy to extend the wavelength detection range of OPD to a longer wavelength, using resonant optical microcavity. We demonstrate a proof-of-concept in PTB7-Th:COTIC-4F blend system, achieving external quantum efficiency (EQE) > 50 % over a broad spectrum 450 - 1100 nm with a peak specific detectivity (D*) of 1.1E13 Jones at 1100 nm, while cut-off bandwidth, speed, and linearity are preserved. By employing a novel small-molecule acceptor IR6, a record high EQE = 35 % and D* = 4.1E12 Jones are obtained at 1150 nm. This research emphasizes the importance of optical design in optoelectronic devices, presenting a considerably simpler method to expand the photodetection range compared to a traditional approach that involves develo** absorbers with narrow optical gaps.
△ Less
Submitted 13 September, 2023;
originally announced September 2023.
-
Emulating Expert Insight: A Robust Strategy for Optimal Experimental Design
Authors:
Matthew R. Carbone,
Hyeong ** Kim,
Chandima Fernando,
Shinjae Yoo,
Daniel Olds,
Howie Joress,
Brian DeCost,
Bruce Ravel,
Yugang Zhang,
Phillip M. Maffettone
Abstract:
The challenge of optimal design of experiments (DOE) pervades materials science, physics, chemistry, and biology. Bayesian optimization has been used to address this challenge in vast sample spaces, although it requires framing experimental campaigns through the lens of maximizing some observable. This framing is insufficient for epistemic research goals that seek to comprehensively analyze a samp…
▽ More
The challenge of optimal design of experiments (DOE) pervades materials science, physics, chemistry, and biology. Bayesian optimization has been used to address this challenge in vast sample spaces, although it requires framing experimental campaigns through the lens of maximizing some observable. This framing is insufficient for epistemic research goals that seek to comprehensively analyze a sample space, without an explicit scalar objective (e.g., the characterization of a wafer or sample library). In this work, we propose a flexible formulation of scientific value that recasts a dataset of input conditions and higher-dimensional observable data into a continuous, scalar metric. Intuitively, the scientific value function measures where observables change significantly, emulating the perspective of experts driving an experiment, and can be used in collaborative analysis tools or as an objective for optimization techniques. We demonstrate this technique by exploring simulated phase boundaries from different observables, autonomously driving a variable temperature measurement of a ferroelectric material, and providing feedback from a nanoparticle synthesis campaign. The method is seamlessly compatible with existing optimization tools, can be extended to multi-modal and multi-fidelity experiments, and can integrate existing models of an experimental system. Because of its flexibility, it can be deployed in a range of experimental settings for autonomous or accelerated experiments.
△ Less
Submitted 25 July, 2023;
originally announced July 2023.
-
Search for inelastic WIMP-iodine scattering with COSINE-100
Authors:
G. Adhikari,
N. Carlin,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
D. H. Lee
, et al. (34 additional authors not shown)
Abstract:
We report the results of a search for inelastic scattering of weakly interacting massive particles (WIMPs) off $^{127}$I nuclei using NaI(Tl) crystals with a data exposure of 97.7 kg$\cdot$years from the COSINE-100 experiment. The signature of inelastic WIMP-$^{127}$I scattering is a nuclear recoil accompanied by a 57.6 keV $γ$-ray from the prompt deexcitation, producing a more energetic signal co…
▽ More
We report the results of a search for inelastic scattering of weakly interacting massive particles (WIMPs) off $^{127}$I nuclei using NaI(Tl) crystals with a data exposure of 97.7 kg$\cdot$years from the COSINE-100 experiment. The signature of inelastic WIMP-$^{127}$I scattering is a nuclear recoil accompanied by a 57.6 keV $γ$-ray from the prompt deexcitation, producing a more energetic signal compared to the typical WIMP nuclear recoil signal. We found no evidence for this inelastic scattering signature and set a 90 $\%$ confidence level upper limit on the WIMP-proton spin-dependent, inelastic scattering cross section of $1.2 \times 10^{-37} {\rm cm^{2}}$ at the WIMP mass 500 ${\rm GeV/c^{2}}$.
△ Less
Submitted 30 October, 2023; v1 submitted 19 July, 2023;
originally announced July 2023.
-
An Open-Source Multi-functional Testing Platform for Optical Phase Change Materials
Authors:
Cosmin-Constantin Popescu,
Khoi Phuong Dao,
Luigi Ranno,
Brian Mills,
Louis Martin,
Yifei Zhang,
David Bono. Brian Neltner,
Tian Gu,
Juejun Hu,
Kiumars Aryana,
William M. Humphreys,
Hyun Jung Kim,
Steven Vitale,
Paul Miller,
Christopher Roberts,
Sarah Geiger,
Dennis Callahan,
Michael Moebius,
Myungkoo Kang,
Kathleen Richardson,
Carlos A. Ríos Ocampo
Abstract:
Owing to their unique tunable optical properties, chalcogenide phase change materials are increasingly being investigated for optics and photonics applications. However, in situ characterization of their phase transition characteristics is a capability that remains inaccessible to many researchers. In this article, we introduce a multi-functional silicon microheater platform capable of in situ mea…
▽ More
Owing to their unique tunable optical properties, chalcogenide phase change materials are increasingly being investigated for optics and photonics applications. However, in situ characterization of their phase transition characteristics is a capability that remains inaccessible to many researchers. In this article, we introduce a multi-functional silicon microheater platform capable of in situ measurement of structural, kinetic, optical, and thermal properties of these materials. The platform can be fabricated leveraging industry-standard silicon foundry manufacturing processes. We fully open-sourced this platform, including complete hardware design and associated software codes.
△ Less
Submitted 12 July, 2023;
originally announced July 2023.
-
Toward accurate thermal modeling of phase change material based photonic devices
Authors:
Kiumars Aryana,
Hyun Jung Kim,
Cosmin-Constantin Popescu,
Steven Vitale,
Hyung Bin Bae,
Taewoo Lee,
Tian Gu,
Juejun Hu
Abstract:
Reconfigurable or programmable photonic devices are rapidly growing and have become an integral part of many optical systems. The ability to selectively modulate electromagnetic waves through electrical stimuli is crucial in the advancement of a variety of applications from data communication and computing devices to environmental science and space explorations. Chalcogenide-based phase change mat…
▽ More
Reconfigurable or programmable photonic devices are rapidly growing and have become an integral part of many optical systems. The ability to selectively modulate electromagnetic waves through electrical stimuli is crucial in the advancement of a variety of applications from data communication and computing devices to environmental science and space explorations. Chalcogenide-based phase change materials (PCMs) are one of the most promising material candidates for reconfigurable photonics due to their large optical contrast between their different solid-state structural phases. Although significant efforts have been devoted to accurate simulation of PCM-based devices, in this paper, we highlight three important aspects which have often evaded prior models yet having significant impacts on the thermal and phase transition behavior of these devices: the enthalpy of fusion, the heat capacity change upon glass transition, as well as the thermal conductivity of liquid-phase PCMs. We further investigated the important topic of switching energy scaling in PCM devices, which also helps explain why the three above-mentioned effects have long been overlooked in electronic PCM memories but only become important in photonics. Our findings offer insight to facilitate accurate modeling of PCM-based photonic devices and can inform the development of more efficient reconfigurable optics.
△ Less
Submitted 23 May, 2023;
originally announced May 2023.
-
Search for bosonic super-weakly interacting massive particles at COSINE-100
Authors:
G. Adhikari,
N. Carlin,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
D. H. Lee
, et al. (34 additional authors not shown)
Abstract:
We present results of a search for bosonic super-weakly interacting massive particles (BSW) as keV scale dark matter candidates that is based on an exposure of 97.7 kg$\cdot$year from the COSINE experiment. In this search, we employ, for the first time, Compton-like as well as absorption processes for pseudoscalar and vector BSWs. No evidence for BSWs is found in the mass range from 10…
▽ More
We present results of a search for bosonic super-weakly interacting massive particles (BSW) as keV scale dark matter candidates that is based on an exposure of 97.7 kg$\cdot$year from the COSINE experiment. In this search, we employ, for the first time, Compton-like as well as absorption processes for pseudoscalar and vector BSWs. No evidence for BSWs is found in the mass range from 10 $\mathrm{keV/c}^2$ to 1 $\mathrm{MeV/c}^2$, and we present the exclusion limits on the dimensionless coupling constants to electrons $g_{ae}$ for pseudoscalar and $κ$ for vector BSWs at 90% confidence level. Our results show that these limits are improved by including the Compton-like process in masses of BSW, above $\mathcal{O}(100\,\mathrm{keV/c}^2)$.
△ Less
Submitted 27 August, 2023; v1 submitted 3 April, 2023;
originally announced April 2023.
-
Active metasurfaces: lighting the path to commercial success
Authors:
Tian Gu,
Hyun Jung Kim,
Clara Rivero-Baleine,
Juejun Hu
Abstract:
Active optical metasurfaces are rapidly emerging as a major frontier in photonics research, development, and commercialization. They promise compact, light-weight, and energy-efficient reconfigurable optical systems with unprecedented performance and functions that can be dynamically defined on-demand. Compared to their passive counterparts, the reconfiguration capacity of active metasurfaces also…
▽ More
Active optical metasurfaces are rapidly emerging as a major frontier in photonics research, development, and commercialization. They promise compact, light-weight, and energy-efficient reconfigurable optical systems with unprecedented performance and functions that can be dynamically defined on-demand. Compared to their passive counterparts, the reconfiguration capacity of active metasurfaces also set additional challenges in scalable design, manufacturing, and control toward their practical deployment. This perspective aims to review the state-of-the-art of active metasurface technologies and their applications while highlighting key research advances essential to enabling their transition from laboratory curiosity to commercial reality.
△ Less
Submitted 30 May, 2022; v1 submitted 27 May, 2022;
originally announced May 2022.
-
Three-year annual modulation search with COSINE-100
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
A. C. Ezeribe,
L. E. França,
C. Ha,
I. S. Hahn,
S. J. Hollick,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim
, et al. (34 additional authors not shown)
Abstract:
COSINE-100 is a direct detection dark matter experiment that aims to test DAMA/LIBRA's claim of dark matter discovery by searching for a dark matter-induced annual modulation signal with NaI(Tl) detectors. We present new constraints on the annual modulation signal from a dataset with a 2.82 yr livetime utilizing an active mass of 61.3 kg, for a total exposure of 173 kg$\cdot$yr. This new result fe…
▽ More
COSINE-100 is a direct detection dark matter experiment that aims to test DAMA/LIBRA's claim of dark matter discovery by searching for a dark matter-induced annual modulation signal with NaI(Tl) detectors. We present new constraints on the annual modulation signal from a dataset with a 2.82 yr livetime utilizing an active mass of 61.3 kg, for a total exposure of 173 kg$\cdot$yr. This new result features an improved event selection that allows for both lowering the energy threshold to 1 keV and a more precise time-dependent background model. In the 1-6 keV and 2-6 keV energy intervals, we observe best-fit values for the modulation amplitude of 0.0067$\pm$0.0042 and 0.0051$\pm$0.0047 counts/(day$\cdot$kg$\cdot$keV), respectively, with a phase fixed at 152.5 days.
△ Less
Submitted 28 October, 2022; v1 submitted 16 November, 2021;
originally announced November 2021.
-
Study on NaI(Tl) crystal at -35 C for dark matter detection
Authors:
S. H. Lee,
G. S. Kim,
H. J. Kim,
K. W. Kim,
J. Y. Lee,
H. S. Lee
Abstract:
We present the responses of a NaI(Tl) crystal in terms of the light yield and pulse shape characteristics of nuclear recoil events at two different temperatures: 22 C (room temperature) and -35 C (low temperature). The light yield is measured using 59.54 keV gamma-rays using a 241Am source relative to the mean charge of single photoelectrons. At the low temperature, we measure a 4.7 +/- 1.3% incre…
▽ More
We present the responses of a NaI(Tl) crystal in terms of the light yield and pulse shape characteristics of nuclear recoil events at two different temperatures: 22 C (room temperature) and -35 C (low temperature). The light yield is measured using 59.54 keV gamma-rays using a 241Am source relative to the mean charge of single photoelectrons. At the low temperature, we measure a 4.7 +/- 1.3% increase in the light yield compared to that at room temperature. A significantly increased decay time is also observed at the low temperature. The responses to nuclear recoil events are measured using neutrons from a 252Cf source and compared to those to electron recoil events. The measured pulse shape discrimination (PSD) power of the NaI(Tl) crystal at the low temperature is found to be improved in the entire energy range studied because of the increased light yield and the different scintillation characteristics. We also find an approximately 9% increased quenching factor of alpha-induced events, which is the light yield ratio of alpha recoil to electron recoil, at the low temperature. This supports the possibility of an increased quenching factor of the nuclear recoil events that are known to have similar processes of dark matter interaction. The increased light yield and the improved PSD power of nuclear recoil events enhance the sensitivity for dark matter detection via dark matter-nuclei interactions.
△ Less
Submitted 11 November, 2021; v1 submitted 5 November, 2021;
originally announced November 2021.
-
Alpha backgrounds in the AMoRE-Pilot experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
S. H. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. Gezhaev,
V. D. Grigoryeva,
V. Gurentsov,
D. H. Ha,
C. Ha,
E. J. Ha,
I. Hahn,
E. J. Jeon
, et al. (81 additional authors not shown)
Abstract:
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit…
▽ More
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.
△ Less
Submitted 5 December, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
The environmental monitoring system at the COSINE-100 experiment
Authors:
H. Kim,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
M. Djamal,
A. C. Ezeribe,
L. E. França,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
H. J. Kim,
K. W. Kim,
S. H. Kim,
S. K. Kim,
W. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
E. K. Lee
, et al. (28 additional authors not shown)
Abstract:
The COSINE-100 experiment is designed to test the DAMA experiment which claimed an observation of a dark matter signal from an annual modulation in their residual event rate. To measure the 1 %-level signal amplitude, it is crucial to control and monitor nearly all environmental quantities that might systematically mimic the signal. The environmental monitoring also helps ensure a stable operation…
▽ More
The COSINE-100 experiment is designed to test the DAMA experiment which claimed an observation of a dark matter signal from an annual modulation in their residual event rate. To measure the 1 %-level signal amplitude, it is crucial to control and monitor nearly all environmental quantities that might systematically mimic the signal. The environmental monitoring also helps ensure a stable operation of the experiment. Here, we describe the design and performance of the centralized environmental monitoring system for the COSINE-100 experiment.
△ Less
Submitted 28 November, 2021; v1 submitted 15 July, 2021;
originally announced July 2021.
-
Enhanced passive thermal stealth properties of VO$_2$ thin films via gradient W do**
Authors:
Hyuk ** Kim,
Young Hwan Choi,
Dong Kyu Lee,
In Hak Lee,
Byoung Ki Choi,
Soo-Hyun Phark,
Young Jun Chang
Abstract:
Thermal stealth and camouflage have been intensively studied for blending objects with their surroundings against remote thermal image detection. Adaptive control of infrared emissivity has been explored extensively as a promising way of thermal stealth, but it still requires an additional feedback control. Passive modulation of emissivity, however, has been remained as a great challenge which req…
▽ More
Thermal stealth and camouflage have been intensively studied for blending objects with their surroundings against remote thermal image detection. Adaptive control of infrared emissivity has been explored extensively as a promising way of thermal stealth, but it still requires an additional feedback control. Passive modulation of emissivity, however, has been remained as a great challenge which requires a precise engineering of emissivity over wide temperature range. Here, we report a drastic improvement of passive camouflage thin films capable of concealing thermal objects at near room temperature without any feedback control, which consists of a vanadium dioxide (VO2) layer with gradient tungsten (W) concentration. The gradient W-do** widens the metal-insulator transition width, accomplishing self-adaptive thermal stealth with a smooth change of emissivity. Our simple approach, applicable to other similar thermal camouflage materials for improving their passive cloaking, will find wide applications, such as passive thermal camouflage, urban energy-saving smart windows, and improved infrared sensors.
△ Less
Submitted 12 May, 2021;
originally announced May 2021.
-
Automated real-time spectral characterization of phase-change tunable optical filters using a linear variable filter and infrared camera
Authors:
David Bombara,
Calum Williams,
Stephen Borg,
Hyun Jung Kim
Abstract:
Actively tunable optical filters based on chalcogenide phase-change materials (PCMs) are an emerging technology with applications across chemical spectroscopy and thermal imaging. The refractive index of an embedded PCM thin film is modulated through an amorphous-to-crystalline phase transition induced through thermal stimulus. Performance metrics include transmittance, passband center wavelength…
▽ More
Actively tunable optical filters based on chalcogenide phase-change materials (PCMs) are an emerging technology with applications across chemical spectroscopy and thermal imaging. The refractive index of an embedded PCM thin film is modulated through an amorphous-to-crystalline phase transition induced through thermal stimulus. Performance metrics include transmittance, passband center wavelength (CWL), and bandwidth; ideally monitored during operation (in situ) or after a set number of tuning cycles to validate real-time operation. Measuring these aforementioned metrics in real-time is challenging. Fourier-transform infrared spectroscopy (FTIR) provides the gold-standard for performance characterization, yet is expensive and inflexible -- incorporating the PCM tuning mechanism is not straightforward, hence in situ electro-optical measurements are challenging. In this work, we implement an open-source MATLAB-controlled real-time performance characterization system consisting of an inexpensive linear variable filter (LVF) and mid-wave infrared camera, capable of switching the PCM-based filters while simultaneously recording in situ filter performance metrics and spectral filtering profile. These metrics are calculated through pixel intensity measurements and displayed on a custom-developed graphical user interface in real-time. The CWL is determined through spatial position of intensity maxima along the LVF's longitudinal axis. Furthermore, plans are detailed for a future experimental system that further reduces cost, is compact, and utilizes a near-infrared camera.
△ Less
Submitted 17 February, 2021;
originally announced February 2021.
-
PCM-net: A refractive index database of chalcogenide phase change materials for tunable nanophotonic device modelling
Authors:
Hyun Jung Kim,
Jung-woo Sohn,
Nina Hong,
Calum Williams,
William Humphreys
Abstract:
Recently, chalcogenide glass based phase change materials (PCMs) have shown utility as a tuning material for a range of nanophotonic devices. Owing to their low loss, ultrafast switching speeds and wide waveband operation, PCMs are integrated in an increasing number of next generation tunable components, including integrated photonic switches, metasurface optics and tunable spectral filters. Nonet…
▽ More
Recently, chalcogenide glass based phase change materials (PCMs) have shown utility as a tuning material for a range of nanophotonic devices. Owing to their low loss, ultrafast switching speeds and wide waveband operation, PCMs are integrated in an increasing number of next generation tunable components, including integrated photonic switches, metasurface optics and tunable spectral filters. Nonetheless, modelling of PCM-based devices is challenging, both in terms of accurate representation of experimentally-derived material properties in different phase states, and standardization of results across the research community. In this work, we introduce PCMnet, an online database of the complex refractive indices of a variety of chalcogenide glass PCMs (such as GeSbTe), as an accessible and indexed repository for data sharing across the PCM community. Refractive indices (n) and extinction coefficients (k) between amorphous and crystalline states are directly extracted from experimentally-derived data in numerous academic research articles, and collated into the material resource database. Due to the inaccuracies associated with our data collection methods, this data is supplemented with additional computationally-generated data, obtained through WVASE, a commercial ellipsometry analysis software package. To demonstrate the utility of PCMnet, we provide a NASA application-driven device optimization example using the optical properties of PCMs collected with our database. We anticipate the database providing great use to the PCM community and coordinated research efforts enabled by PCMnet will promote the shared repository for the selection of appropriate PCMs for tunable nanophotonic device design for a range of applications.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
A Silicon Beam Tracker
Authors:
J. H. Han,
H. S. Ahn,
J. B. Bae,
H. J. Hyun,
S. W. Jung,
D. H. Kah,
C. H. Kim,
H. J. Kim,
K. C. Kim,
M. H. Lee,
L. Lutz,
A. Malinin,
H. Park,
S. Ryu,
E. S. Seo,
P. Walpole,
J. Wu,
J. H. Yoo,
Y. S. Yoon,
S. Y. Zinn
Abstract:
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT) was constructed with an active area of 32.0 x 32.0 mm2 to provide this capability for the beam calibration of the Cosmic Ray Energetics And Mass (CREAM) calori…
▽ More
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT) was constructed with an active area of 32.0 x 32.0 mm2 to provide this capability for the beam calibration of the Cosmic Ray Energetics And Mass (CREAM) calorimeter. The tracker consists of two modules, each comprised of two orthogonal layers of 380 μm thick silicon strip sensors. In one module each layer is a 64-channel AC-coupled single-sided silicon strip detector (SSD) with a 0.5 mm pitch. In the other, each layer is a 32-channel DC-coupled single-sided SSD with a 1.0 mm pitch. The signals from the 4 layers are read out using modified CREAM hodoscope front-end electronics with a USB 2.0 interface board to a Linux DAQ PC. In this paper, we present the construction of the SBT, along with its performance in radioactive source tests and in a CERN beam test in October 2006.
△ Less
Submitted 23 September, 2020;
originally announced September 2020.
-
Lowering the energy threshold in COSINE-100 dark matter searches
Authors:
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
M. Djamal,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
W. G. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
E. K. Lee,
H. S. Lee,
J. Lee,
J. Y. Lee
, et al. (21 additional authors not shown)
Abstract:
COSINE-100 is a dark matter detection experiment that uses NaI(Tl) crystal detectors operating at the Yangyang underground laboratory in Korea since September 2016. Its main goal is to test the annual modulation observed by the DAMA/LIBRA experiment with the same target medium. Recently DAMA/LIBRA has released data with an energy threshold lowered to 1 keV, and the persistent annual modulation beh…
▽ More
COSINE-100 is a dark matter detection experiment that uses NaI(Tl) crystal detectors operating at the Yangyang underground laboratory in Korea since September 2016. Its main goal is to test the annual modulation observed by the DAMA/LIBRA experiment with the same target medium. Recently DAMA/LIBRA has released data with an energy threshold lowered to 1 keV, and the persistent annual modulation behavior is still observed at 9.5$σ$. By lowering the energy threshold for electron recoils to 1 keV, COSINE-100 annual modulation results can be compared to those of DAMA/LIBRA in a model-independent way. Additionally, the event selection methods provide an access to a few to sub-GeV dark matter particles using constant rate studies. In this article, we discuss the COSINE-100 event selection algorithm, its validation, and efficiencies near the threshold.
△ Less
Submitted 21 March, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Measurement of the cosmic muon annual and diurnal flux variation with the COSINE-100 detector
Authors:
COSINE-100 Collaboration,
:,
H. Prihtiadi,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
M. Djamal,
A. C. Ezeribe,
L. E. França,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
W. G. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
E. K. Lee
, et al. (23 additional authors not shown)
Abstract:
We report measurements of annual and diurnal modulations of the cosmic-ray muon rate in the Yangyang underground laboratory (Y2L) using 952 days of COSINE-100 data acquired between September 2016 and July 2019. A correlation of the muon rate with the atmospheric temperature is observed and its amplitude on the muon rate is determined. The effective atmospheric temperature and muon rate variations…
▽ More
We report measurements of annual and diurnal modulations of the cosmic-ray muon rate in the Yangyang underground laboratory (Y2L) using 952 days of COSINE-100 data acquired between September 2016 and July 2019. A correlation of the muon rate with the atmospheric temperature is observed and its amplitude on the muon rate is determined. The effective atmospheric temperature and muon rate variations are positively correlated with a measured effective temperature coefficient of $α_{T}$ = 0.80 $\pm$ 0.11. This result is consistent with a model of meson production in the atmosphere. We also searched for a diurnal modulation in the underground muon rate by comparing one-hour intervals. No significant diurnal modulation of the muon rate was observed.
△ Less
Submitted 28 May, 2020; v1 submitted 27 May, 2020;
originally announced May 2020.
-
Growth and development of pure Li2MoO4 crystals for rare event experiment at CUP
Authors:
J. K. Son,
J. S. Choe,
O. Gileva,
I. S. Hahn,
W. G. Kang,
D. Y. Kim,
G. W. Kim,
H. J. Kim,
Y. D. Kim,
C. H. Lee,
E. K. Lee,
M. H. Lee,
D. S. Leonard,
H. K. Park,
S. Y. Park,
S. J. Ra,
K. A. Shin
Abstract:
The Center for Underground Physics (CUP) of the Institute for Basic Science (IBS) is searching for the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) of 100Mo in the molybdate crystals of the AMoRE experiment. The experiment requires pure scintillation crystals to minimize internal backgrounds that can affect the 0ν\b{eta}\b{eta} signal. For the last few years, we have been growing and studying…
▽ More
The Center for Underground Physics (CUP) of the Institute for Basic Science (IBS) is searching for the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) of 100Mo in the molybdate crystals of the AMoRE experiment. The experiment requires pure scintillation crystals to minimize internal backgrounds that can affect the 0ν\b{eta}\b{eta} signal. For the last few years, we have been growing and studying Li2MoO4 crystals in a clean-environment facility to minimize external contamination during the crystal growth. Before growing Li2100MoO4 crystal, we have studied Li2natMoO4 crystal growth by a conventional Czochralski (CZ) grower. We grew a few different kinds of Li2natMO4 crystals using different raw materials in a campaign to minimize impurities. We prepared the fused Al2O3 refractories for the growth of ingots. Purities of the grown crystals were measured with high purity germanium detectors and by inductively coupled plasma mass spectrometry. The results show that the Li2MoO4 crystal has purity levels suitable for rare-event experiments. In this study, we present the growth of Li2MoO4 crystals at CUP and their purities.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Purification and recovery of 100MoO3 in crystal production for AMoRE experiment
Authors:
O. Gileva,
J. S. Choe,
H. J. Kim,
Y. D. Kim,
M. H. Lee,
H. K. Park,
K. A. Shin
Abstract:
The AMoRE collaboration searches for the neutrinoless double-beta decay of 100Mo with ultra-radiopure molybdate crystals operated as low-temperature scintillating bolometers. For such a rare event search experiment, the techniques for investigating and reducing radioactive background contaminants in detector materials are extremely crucial. This paper discusses techniques for deep purification of…
▽ More
The AMoRE collaboration searches for the neutrinoless double-beta decay of 100Mo with ultra-radiopure molybdate crystals operated as low-temperature scintillating bolometers. For such a rare event search experiment, the techniques for investigating and reducing radioactive background contaminants in detector materials are extremely crucial. This paper discusses techniques for deep purification of enriched molybdenum for growing the crystals and the recovery of 100MoO3 from the residual melt left after growing lithium molybdate crystals. The purities of enriched molybdenum trioxide powders before and after the purification and that of the recovered powder were tested with ICP-MS; results of these tests are presented.
△ Less
Submitted 13 May, 2020;
originally announced May 2020.
-
Performance of the ISS-CREAM calorimeter in a calibration beam test
Authors:
H. G. Zhang,
D. Angelaszek,
M. Copley,
J. H. Han,
H. G. Huh,
Y. S. Hwang,
H. J. Hyun,
J. A. Jeon,
K. C. Kim,
M. H. Kim,
H. J. Kim,
K. Kwashnak,
H. Y. Lee,
J. Lee,
M. H. Lee,
J. Lundquist,
L. Lutz,
A. Malinin,
H. Park,
J. M. Park,
N. Picot-Clemente,
E. S. Seo,
J. Smith,
J. Wu,
Z. Y. Yin
, et al. (1 additional authors not shown)
Abstract:
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers…
▽ More
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers of secondary particles develop in the calorimeter. The energy deposition in the calorimeter is proportional to the particle energy.
As a predecessor to ISS-CREAM, the balloon-borne CREAM instrument was successfully flown seven times over Antarctica for a cumulative exposure of 191 days. The CREAM calorimeter demonstrated its capability to measure energies of cosmic-ray particles, and the ISS-CREAM calorimeter is expected to have a similar performance. Before the launch, an engineering-unit calorimeter was shipped to CERN for calibration and performance tests. This beam test included position, energy, and angle scans of electron and pion beams together with a high-voltage scan for calibration and characterization. Additionally, an attenuation effect in the scintillating fibers was studied. In this paper, beam test results, including corrections for the attenuation effect, are presented.
△ Less
Submitted 9 June, 2021; v1 submitted 21 April, 2020;
originally announced April 2020.
-
The COSINE-100 Liquid Scintillator Veto System
Authors:
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
M. Djamal,
A. C. Ezeribe,
L. E. Franca,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
W. G. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
E. K. Lee,
H. S. Lee,
J. Lee,
J. Y. Lee
, et al. (21 additional authors not shown)
Abstract:
This paper describes the liquid scintillator veto system for the COSINE-100 dark matter experiment and its performance. The COSINE-100 detector consists of eight NaI(Tl) crystals immersed in 2200~L of linear alkylbenzene-based liquid scintillator. The liquid scintillator tags between 65 and 75\% of the internal $^{40}$K background in the 2--6 keV energy region. We also describe the background mode…
▽ More
This paper describes the liquid scintillator veto system for the COSINE-100 dark matter experiment and its performance. The COSINE-100 detector consists of eight NaI(Tl) crystals immersed in 2200~L of linear alkylbenzene-based liquid scintillator. The liquid scintillator tags between 65 and 75\% of the internal $^{40}$K background in the 2--6 keV energy region. We also describe the background model for the liquid scintillator, which is primarily used to assess its energy calibration and threshold.
△ Less
Submitted 14 May, 2021; v1 submitted 5 April, 2020;
originally announced April 2020.
-
Tunable mid-wave infrared Fabry-Perot bandpass filters using phase-change GeSbTe
Authors:
Calum Williams,
Nina Hong,
Matthew Julian,
Stephen Borg,
Hyun Jung Kim
Abstract:
We demonstrate spectrally-tunable Fabry-Perot bandpass filters operating across the MWIR by utilizing the phase-change material GeSbTe (GST) as a tunable cavity medium between two (Ge:Si) distributed Bragg reflectors. The induced refractive index modulation of GST increases the cavity's optical path length, red-shifting the passband. Our filters have spectral-tunability of ~300 nm, transmission ef…
▽ More
We demonstrate spectrally-tunable Fabry-Perot bandpass filters operating across the MWIR by utilizing the phase-change material GeSbTe (GST) as a tunable cavity medium between two (Ge:Si) distributed Bragg reflectors. The induced refractive index modulation of GST increases the cavity's optical path length, red-shifting the passband. Our filters have spectral-tunability of ~300 nm, transmission efficiencies of 60-75% and narrowband FWHMs of 50-65 nm (Q-factor ~70-90). We further show multispectral thermal imaging and gas sensing. By matching the filter's initial passband to a CO$_{2}$ vibrational-absorption mode (~4.25 $μ$m), tunable atmospheric CO$_{2}$ sensing and dynamic plume visualization of added CO$_{2}$ is realized.
△ Less
Submitted 14 February, 2020;
originally announced February 2020.
-
All-optical continuous tuning of phase-change plasmonic metasurfaces for multispectral thermal imaging
Authors:
Matthew N. Julian,
Calum Williams,
Stephen Borg,
Scott Bartram,
Hyun Jung Kim
Abstract:
Actively tunable, narrowband spectral filtering across arbitrary optical wavebands is highly desirable in a plethora of applications, from chemical sensing, hyperspectral imaging to infrared astronomy. Yet, the ability to actively reconfigure the optical properties of a solid-state narrowband filter remains elusive. Existing solutions require either moving parts, have slow response times or provid…
▽ More
Actively tunable, narrowband spectral filtering across arbitrary optical wavebands is highly desirable in a plethora of applications, from chemical sensing, hyperspectral imaging to infrared astronomy. Yet, the ability to actively reconfigure the optical properties of a solid-state narrowband filter remains elusive. Existing solutions require either moving parts, have slow response times or provide limited spectral coverage. Here, we demonstrate a continuously tunable, spectrally-agnostic, all-solid-state, narrowband phase-change metasurface filter based on a GeSbTe (GST)-embedded plasmonic nanohole array. The passband of the presented tunable filter is ~74 nm with ~70% transmittance and operates across 3 - 5 $μ$m; the thermal imaging waveband. Continuous, reconfigurable tuning is achieved by exploiting intermediate GST phases via optical switching with a single nanosecond laser pulse and material stability is verified through multiple switching cycles. We further demonstrate multispectral thermal imaging in the mid-wave infrared using our phase-change metasurfaces. Our results pave the way for highly functional, reduced power, compact hyperspectral imaging systems and optical filters.
△ Less
Submitted 17 December, 2019;
originally announced December 2019.
-
Physics driven reduced order model for real time blood flow simulations
Authors:
Sethuraman Sankaran,
David Lesage,
Rhea Tombropoulos,
Nan Xiao,
Hyun ** Kim,
David Spain,
Michiel Schaap,
Charles A. Taylor
Abstract:
Predictive modeling of blood flow and pressure have numerous applications ranging from non-invasive assessment of functional significance of disease to planning invasive procedures. While several such predictive modeling techniques have been proposed, their use in the clinic has been limited due in part to the significant time required to perform virtual interventions and compute the resultant cha…
▽ More
Predictive modeling of blood flow and pressure have numerous applications ranging from non-invasive assessment of functional significance of disease to planning invasive procedures. While several such predictive modeling techniques have been proposed, their use in the clinic has been limited due in part to the significant time required to perform virtual interventions and compute the resultant changes in hemodynamic conditions. We propose a fast hemodynamic assessment method based on first constructing an exploration space of geometries, tailored to each patient, and subsequently building a physics driven reduced order model in this space. We demonstrate that this method can predict fractional flow reserve derived from coronary computed tomography angiography in response to changes to a patient-specific lumen geometry in real time while achieving high accuracy when compared to computational fluid dynamics simulations. We validated this method on over 1300 patients that received a coronary CT scan and demonstrated a correlation coefficient of 0.98 with an error of 0.005 +- 0.015 (95% confidence interval: (-0.020, 0.031)) as compared to three-dimensional blood flow calculations.
△ Less
Submitted 4 November, 2019;
originally announced November 2019.
-
EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes
Authors:
P. Ahlburg,
S. Arfaoui,
J. -H. Arling,
H. Augustin,
D. Barney,
M. Benoit,
T. Bisanz,
E. Corrin,
D. Cussans,
D. Dannheim,
J. Dreyling-Eschweiler,
T. Eichhorn,
A. Fiergolski,
I. -M. Gregor,
J. Grosse-Knetter,
D. Haas,
L. Huth,
A. Irles,
H. Jansen,
J. Janssen,
M. Keil,
J. S. Keller,
M. Kiehn,
H. J. Kim,
J. Kroll
, et al. (32 additional authors not shown)
Abstract:
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed…
▽ More
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.
△ Less
Submitted 18 November, 2019; v1 submitted 30 September, 2019;
originally announced September 2019.
-
Direct observation of Dirac states in Bi2Te3 nanoplatelets by 125Te NMR
Authors:
Wassilios Papawassiliou,
Aleksander Jaworski,
Andrew J. Pell,
Jae Hyuck Jang,
Yeonho Kim,
Sang-Chul Lee,
Hae ** Kim,
Yasser Alwahedi,
Saeed Alhassan,
Ahmed Subrati,
Michael Fardis,
Marina Karagianni,
Nikolaos Panopoulos,
Janez Dolinsek,
Georgios Papavassiliou
Abstract:
Detection of the metallic Dirac electronic states on the surface of Topological Insulators (TIs) is a tribune for a small number of experimental techniques the most prominent of which is Angle Resolved Photoemission Spectroscopy. However, there is no experimental method showing at atomic scale resolution how the Dirac electrons extend inside TI systems. This is a critical issue in the study of imp…
▽ More
Detection of the metallic Dirac electronic states on the surface of Topological Insulators (TIs) is a tribune for a small number of experimental techniques the most prominent of which is Angle Resolved Photoemission Spectroscopy. However, there is no experimental method showing at atomic scale resolution how the Dirac electrons extend inside TI systems. This is a critical issue in the study of important surface quantum properties, especially topological quasiparticle excitations. Herein, by applying advanced DFT-assisted solid-state 125Te Nuclear Magnetic Resonance on Bi2Te3 nanoplatelets, we succeeded in uncovering the hitherto invisible NMR signals with magnetic shielding influenced by the Dirac electrons, and subsequently showed how Dirac electrons spread and interact with the bulk interior of the nanoplatelets.
△ Less
Submitted 25 September, 2019;
originally announced September 2019.
-
A Study of NaI(Tl) crystal Encapsulation using Organic scintillators for the Dark Matter Search
Authors:
J. Y. Lee,
G. Adhikari,
C. Ha,
H. J. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
H. S. Lee
Abstract:
Scintillating NaI(Tl) crystals are used for various rare decay experiments, such as dark matter searches. The hygroscopicity of NaI(Tl) crystal makes the construction of crystal detectors in these experiments challenging and requires a tight encapsulation to prevent from air contact. More importantly, in a low radioactivity measurement, identification of external radiations and surface contaminati…
▽ More
Scintillating NaI(Tl) crystals are used for various rare decay experiments, such as dark matter searches. The hygroscopicity of NaI(Tl) crystal makes the construction of crystal detectors in these experiments challenging and requires a tight encapsulation to prevent from air contact. More importantly, in a low radioactivity measurement, identification of external radiations and surface contamination is crucial to characterize the origin of total crystal radioactivities. Studies for NaI(Tl) crystal encapsulation with active organic scintillator vetoes have been performed to mitigate the above-mentioned issues simultaneously. A bare crystal is directly coupled with liquid and plastic scintillators to tag external radiations that penetrate from the outer part of the crystal. We report the pulse shape discrimination for organic scintillator pulses from those of the crystal scintillator in a single detector setup which makes external gammas identifiable and long-term stability tests of the detector setup.
△ Less
Submitted 12 August, 2019;
originally announced August 2019.
-
Comparison between DAMA/LIBRA and COSINE-100 in the light of Quenching Factors
Authors:
Y. J. Ko,
K. W. Kim,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
J. J. Choi,
S. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
W. G. Kang,
M. Kauer,
G. S. Kim,
H. Kim,
H. J. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
E. K. Lee,
H. S. Lee
, et al. (24 additional authors not shown)
Abstract:
There is a long standing debate about whether or not the annual modulation signal reported by the DAMA/LIBRA collaboration is induced by Weakly Interacting Massive Particles~(WIMP) in the galaxy's dark matter halo scattering from nuclides in their NaI(Tl) crystal target/detector. This is because regions of WIMP-mass vs. WIMP-nucleon cross-section parameter space that can accommodate the DAMA/LIBRA…
▽ More
There is a long standing debate about whether or not the annual modulation signal reported by the DAMA/LIBRA collaboration is induced by Weakly Interacting Massive Particles~(WIMP) in the galaxy's dark matter halo scattering from nuclides in their NaI(Tl) crystal target/detector. This is because regions of WIMP-mass vs. WIMP-nucleon cross-section parameter space that can accommodate the DAMA/LIBRA-phase1 modulation signal in the context of the standard WIMP dark matter galactic halo and isospin-conserving~(canonical), spin-independent~(SI) WIMP-nucleon interactions have been excluded by many of other dark matter search experiments including COSINE-100, which uses the same NaI(Tl) target/detector material.
Moreover, the recently released DAMA/LIBRA-phase2 results are inconsistent with an interpretation as WIMP-nuclide scattering via the canonical SI interaction and prefer, instead, isospin-violating or spin-dependent interactions.
Dark matter interpretations of the DAMA/LIBRA signal are sensitive to the NaI(Tl) scintillation efficiency for nuclear recoils, which is characterized by so-called quenching factors~(QF), and the QF values used in previous studies differ significantly from recently reported measurements, which may have led to incorrect interpretations of the DAMA/LIBRA signal. In this article, the compatibility of the DAMA/LIBRA and COSINE-100 results, in light of the new QF measurements is examined for different possible types of WIMP-nucleon interactions. The resulting allowed parameter space regions associated with the DAMA/LIBRA signal are explicitly compared with 90\% confidence level upper limits from the initial 59.5~day COSINE-100 exposure. With the newly measured QF values, the allowed 3$σ$ regions from the DAMA/LIBRA data are still generally excluded by the COSINE-100 data.
△ Less
Submitted 23 October, 2019; v1 submitted 10 July, 2019;
originally announced July 2019.
-
Search for a Dark Matter-Induced Annual Modulation Signal in NaI(Tl) with the COSINE-100 Experiment
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. Kang,
M. Kauer,
G. S. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim
, et al. (25 additional authors not shown)
Abstract:
We present new constraints on the dark matter-induced annual modulation signal using 1.7 years, of COSINE-100 data with a total exposure of 97.7 kg$\cdot$years. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl)…
▽ More
We present new constraints on the dark matter-induced annual modulation signal using 1.7 years, of COSINE-100 data with a total exposure of 97.7 kg$\cdot$years. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl) target. The crystal data show a 2.7 cpd/kg/keV background rate on average in the 2--6 keV energy region of interest. Using a $χ$-squared minimization method we observe best fit values for modulation amplitude and phase of 0.0092$\pm$0.0067 cpd/kg/keV and 127.2$\pm$45 d, respectively.
△ Less
Submitted 25 July, 2019; v1 submitted 24 March, 2019;
originally announced March 2019.
-
First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
D. M. Chernyak,
J. S. Choe,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. D. Grigoryeva,
V. I. Gurentsov,
O. Gylova,
C. Ha,
D. H. Ha
, et al. (84 additional authors not shown)
Abstract:
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-de…
▽ More
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.
△ Less
Submitted 7 May, 2019; v1 submitted 22 March, 2019;
originally announced March 2019.
-
The First Direct Search for Inelastic Boosted Dark Matter with COSINE-100
Authors:
C. Ha,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
M. Djamal,
A. C. Ezeribe,
I. S. Hahn,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. Kang,
M. Kauer,
G. S. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
V. A. Kudryavtsev
, et al. (23 additional authors not shown)
Abstract:
A search for inelastic boosted dark matter (iBDM) using the COSINE-100 detector with 59.5 days of data is presented. This relativistic dark matter is theorized to interact with the target material through inelastic scattering with electrons, creating a heavier state that subsequently produces standard model particles, such as an electron-positron pair. In this study, we search for this electron-po…
▽ More
A search for inelastic boosted dark matter (iBDM) using the COSINE-100 detector with 59.5 days of data is presented. This relativistic dark matter is theorized to interact with the target material through inelastic scattering with electrons, creating a heavier state that subsequently produces standard model particles, such as an electron-positron pair. In this study, we search for this electron-positron pair in coincidence with the initially scattered electron as a signature for an iBDM interaction. No excess over the predicted background event rate is observed. Therefore, we present limits on iBDM interactions under various hypotheses, one of which allows us to explore an area of the experimental search for iBDM using a terrestrial detector.
△ Less
Submitted 30 January, 2019; v1 submitted 22 November, 2018;
originally announced November 2018.
-
The COSINE-100 Data Acquisition System
Authors:
COSINE-100 Collaboration,
:,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
W. S. Kang,
M. Kauer,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim
, et al. (23 additional authors not shown)
Abstract:
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital co…
▽ More
COSINE-100 is a dark matter direct detection experiment designed to test the annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100 consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid scintillator veto, and 37 muon detector panels. We present details of the data acquisition system of COSINE-100, including waveform storage using flash analog-to-digital converters for crystal events and integrated charge storage using charge-sensitive analog-to-digital converters for liquid scintillator and plastic scintillator muon veto events. We also discuss several trigger conditions developed in order to distinguish signal events from photomultiplier noise events. The total trigger rate observed for the crystal/liquid scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
△ Less
Submitted 26 June, 2018;
originally announced June 2018.
-
Limits on Interactions between Weakly Interacting Massive Particles and Nucleons Obtained with NaI(Tl) crystal Detectors
Authors:
K. W. Kim,
G. Adhikari,
P. Adhikari,
S. Choi,
C. Ha,
I. S. Hahn,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
H. J. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
Y. J. Ko,
H. S. Lee,
J. S. Lee,
J. Y. Lee,
M. H. Lee,
D. S. Leonard,
S. L. Olsen,
B. J. Park,
H. K. Park,
H. S. Park,
K. S. Park
Abstract:
Limits on the cross section for weakly interacting massive particles (WIMPs) scattering off nucleons in the NaI(Tl) detectors at the Yangyang Underground Laboratory are obtained with a 2967.4 kg*day data exposure. Nuclei recoiling are identified by the pulse shape of scintillating photon signals. Data are consistent with no nuclear recoil hypothesis, and 90% confidence level upper limits are set.…
▽ More
Limits on the cross section for weakly interacting massive particles (WIMPs) scattering off nucleons in the NaI(Tl) detectors at the Yangyang Underground Laboratory are obtained with a 2967.4 kg*day data exposure. Nuclei recoiling are identified by the pulse shape of scintillating photon signals. Data are consistent with no nuclear recoil hypothesis, and 90% confidence level upper limits are set. These limits partially exclude the DAMA/LIBRA region of WIMP-sodium interaction with the same NaI(Tl) target detector. This 90% confidence level upper limit on WIMP-nucleon spin-independent cross section is 3.26*10^-4 pb for a WIMP mass at 10 GeV/c^2.
△ Less
Submitted 21 January, 2019; v1 submitted 18 June, 2018;
originally announced June 2018.
-
Background model for the NaI(Tl) crystals in COSINE-100
Authors:
P. Adhikari,
G. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Q. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. G. Kang,
M. Kauer,
W. S. Kang,
B. H. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim
, et al. (24 additional authors not shown)
Abstract:
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmog…
▽ More
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2-6) keV energy interval. The dominant contributors in this energy region are found to be $^{210}$Pb and $^3$H.
△ Less
Submitted 11 June, 2018; v1 submitted 14 April, 2018;
originally announced April 2018.
-
Muon detector for the COSINE-100 experiment
Authors:
COSINE-100 Collaboration,
:,
H. Prihtiadi,
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Q. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. Kang,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
N. Y. Kim
, et al. (28 additional authors not shown)
Abstract:
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impa…
▽ More
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance test of each module have been performed at a ground laboratory. The installation of the detector in Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$ 10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector and the results from the analysis are presented.
△ Less
Submitted 5 December, 2017;
originally announced December 2017.
-
Initial Performance of the COSINE-100 Experiment
Authors:
G. Adhikari,
P. Adhikari,
E. Barbosa de Souza,
N. Carlin,
S. Choi,
W. Q. Choi,
M. Djamal,
A. C. Ezeribe,
C. Ha,
I. S. Hahn,
A. J. F. Hubbard,
E. J. Jeon,
J. H. Jo,
H. W. Joo,
W. Kang,
W. G. Kang,
M. Kauer,
B. H. Kim,
H. Kim,
H. J. Kim,
K. W. Kim,
M. C. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim
, et al. (27 additional authors not shown)
Abstract:
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and wil…
▽ More
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least two years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment.
△ Less
Submitted 11 February, 2018; v1 submitted 15 October, 2017;
originally announced October 2017.
-
The Characterization of new Eu2+ doped TlSr2I5 Scintillator Crystals
Authors:
H. J. Kim,
Gul Rooh,
Arshad Khan,
H. Park,
Sunghwan Kim
Abstract:
TlSr2I5: Eu2+ is a newly discovered scintillator and show promising scintillation properties for X- and γ-rays spectroscopy applications. Two zones vertical Bridgman technique is used for the growth of this scintillator. Luminescence properties of the grown crystals are measured under X-ray excitation at room temperature. Pure and Eu2+ doped crystals contained broad emission bands between 445-670…
▽ More
TlSr2I5: Eu2+ is a newly discovered scintillator and show promising scintillation properties for X- and γ-rays spectroscopy applications. Two zones vertical Bridgman technique is used for the growth of this scintillator. Luminescence properties of the grown crystals are measured under X-ray excitation at room temperature. Pure and Eu2+ doped crystals contained broad emission bands between 445-670 nm peaking at 528 nm and 430-600 nm peaking at 463 nm, respectively. Energy resolution, light yield and decay time profiles are studied under 662 keV γ-ray excitation using 137Cs radioactive source. Energy resolution of 4.2 % (FWHM) is obtained for 3 mol% Eu2+ doped crystal. For the same sample, light yield of 70,000 ph/MeV is also obtained. Three and two decay constants are observed for the pure and Eu2+ doped samples, respectively at room temperature. Effective Z-number and density are found to be 61 and 5.30 g/cm3, respectively.
△ Less
Submitted 9 September, 2017;
originally announced September 2017.
-
New Tl2LaBr5: Ce3+ Crystal Scintillator for γ-Rays Detection
Authors:
H. J. Kim,
Gul Rooh,
Arshad Khan,
Sunghwan Kim
Abstract:
In this study we present our preliminary report on the scintillation properties of new Ce-doped Tl2LaBr5 single crystal. Two zones vertical Bridgman technique is used for the growth of this compound. Pure and Ce-doped samples showed maximum emission peaks at 435 nm and 415 nm, respectively. Best light yield of 43,000+-4300 ph/MeV with 6.3% (FWHM) energy resolution is obtained for 5% Ce-doped sampl…
▽ More
In this study we present our preliminary report on the scintillation properties of new Ce-doped Tl2LaBr5 single crystal. Two zones vertical Bridgman technique is used for the growth of this compound. Pure and Ce-doped samples showed maximum emission peaks at 435 nm and 415 nm, respectively. Best light yield of 43,000+-4300 ph/MeV with 6.3% (FWHM) energy resolution is obtained for 5% Ce-doped sample under γ-ray excitation. Single exponential decay time constant of 25 ns is observed for 5% Ce doped sample. Effective Z-number is found to be 67, therefore efficient detection of X- and γ-ray will be possible. Preliminary results revealed that this compound will be an ideal candidate for the medical imaging techniques. Further investigations are under way for the determination of optimized conditions of this compound.
△ Less
Submitted 9 December, 2016;
originally announced December 2016.
-
Physics Potentials with the Second Hyper-Kamiokande Detector in Korea
Authors:
Hyper-Kamiokande proto-collaboration,
:,
K. Abe,
Ke. Abe,
S. H. Ahn,
H. Aihara,
A. Aimi,
R. Akutsu,
C. Andreopoulos,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
Y. Ashida,
V. Aushev,
M. Barbi,
G. J. Barker,
G. Barr,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
L. Berns,
T. Berry,
S. Bhadra,
D. Bravo-Bergu no
, et al. (331 additional authors not shown)
Abstract:
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are sev…
▽ More
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are several candidate sites in Korea with baselines of 1,000$\sim$1,300~km and OAAs of 1$^{\textrm{o}}$$\sim$3$^{\textrm{o}}$. We conducted sensitivity studies on neutrino oscillation physics for a second detector, either in Japan (JD $\times$ 2) or Korea (JD + KD) and compared the results with a single detector in Japan. Leptonic CP violation sensitivity is improved especially when the CP is non-maximally violated. The larger matter effect at Korean candidate sites significantly enhances sensitivities to non-standard interactions of neutrinos and mass ordering determination. Current studies indicate the best sensitivity is obtained at Mt. Bisul (1,088~km baseline, $1.3^\circ$ OAA). Thanks to a larger (1,000~m) overburden than the first detector site, clear improvements to sensitivities for solar and supernova relic neutrino searches are expected.
△ Less
Submitted 26 March, 2018; v1 submitted 18 November, 2016;
originally announced November 2016.
-
Sterile neutrino search at NEOS Experiment
Authors:
Y. J. Ko,
B. R. Kim,
J. Y. Kim,
B. Y. Han,
C. H. Jang,
E. J. Jeon,
K. K. Joo,
H. J. Kim,
H. S. Kim,
Y. D. Kim,
Jaison Lee,
J. Y. Lee,
M. H. Lee,
Y. M. Oh,
H. K. Park,
H. S. Park,
K. S. Park,
K. M. Seo,
Kim Siyeon,
G. M. Sun
Abstract:
An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of abou…
▽ More
An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of about 22. The shape of the antineutrino energy spectrum obtained from eight-month data-taking period is compared with a hypothesis of oscillations due to active-sterile antineutrino mixing. It is found to be consistent with no oscillation. An excess around 5 MeV prompt energy range is observed as seen in existing longer baseline experiments. The parameter space of $\sin^{2}2θ_{14}$ down below 0.1 for $Δm^{2}_{41}$ ranging from 0.2 eV$^{2}$ to 2.3 eV$^{2}$ and the optimum point for the previously reported reactor antineutrino anomaly are excluded with a confidence level higher than 90%.
△ Less
Submitted 21 March, 2017; v1 submitted 17 October, 2016;
originally announced October 2016.