-
Evaluation of the performance of the event reconstruction algorithms in the JSNS$^2$ experiment using a $^{252}$Cf calibration source
Authors:
D. H. Lee,
M. K. Cheoun,
J. H. Choi,
J. Y. Choi,
T. Dodo,
J. Goh,
K. Haga,
M. Harada,
S. Hasegawa,
W. Hwang,
T. Iida,
H. I. Jang,
J. S. Jang,
K. K. Joo,
D. E. Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim,
J. Y. Kim,
S. B Kim,
W. Kim,
H. Kinoshita,
T. Konno,
I. T. Lim
, et al. (28 additional authors not shown)
Abstract:
JSNS$^2$ searches for short baseline neutrino oscillations with a baseline of 24~meters and a target of 17~tonnes of the Gd-loaded liquid scintillator. The correct algorithm on the event reconstruction of events, which determines the position and energy of neutrino interactions in the detector, are essential for the physics analysis of the data from the experiment. Therefore, the performance of th…
▽ More
JSNS$^2$ searches for short baseline neutrino oscillations with a baseline of 24~meters and a target of 17~tonnes of the Gd-loaded liquid scintillator. The correct algorithm on the event reconstruction of events, which determines the position and energy of neutrino interactions in the detector, are essential for the physics analysis of the data from the experiment. Therefore, the performance of the event reconstruction is carefully checked with calibrations using $^{252}$Cf source. This manuscript describes the methodology and the performance of the event reconstruction.
△ Less
Submitted 5 April, 2024;
originally announced April 2024.
-
Pulse Shape Discrimination in JSNS$^2$
Authors:
T. Dodo,
M. K. Cheoun,
J. H. Choi,
J. Y. Choi,
J. Goh,
K. Haga,
M. Harada,
S. Hasegawa,
W. Hwang,
T. Iida,
H. I. Jang,
J. S. Jang,
K. K. Joo,
D. E. Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim,
J. Y. Kim,
S. B. Kim,
W. Kim,
H. Kinoshita,
T. Konno,
D. H. Lee,
I. T. Lim
, et al. (29 additional authors not shown)
Abstract:
JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\barν_μ \rightarrow \barν_e$ appearance oscillations using neutrinos with muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS$^2$ detector is loca…
▽ More
JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\barν_μ \rightarrow \barν_e$ appearance oscillations using neutrinos with muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS$^2$ detector is located above ground, on the third floor of the building. We have achieved 95$\%$ rejection of neutron events while kee** 90$\%$ of signal, electron-like events using a data driven likelihood method.
△ Less
Submitted 28 March, 2024;
originally announced April 2024.
-
The acrylic vessel for JSNS$^{2}$-II neutrino target
Authors:
C. D. Shin,
S. Ajimura,
M. K. Cheoun,
J. H. Choi,
J. Y. Choi,
T. Dodo,
J. Goh,
K. Haga,
M. Harada,
S. Hasegawa,
T. Hiraiwa,
W. Hwang,
T. Iida,
H. I. Jang,
J. S. Jang,
H. Jeon,
S. Jeon,
K. K. Joo,
D. E. Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim,
J. Y. Kim,
S. B. Kim
, et al. (35 additional authors not shown)
Abstract:
The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS$^{2}$-II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume…
▽ More
The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS$^{2}$-II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. The specifications, design, and measured properties of the acrylic vessel are described.
△ Less
Submitted 11 December, 2023; v1 submitted 4 September, 2023;
originally announced September 2023.
-
Study on the accidental background of the JSNS$^2$ experiment
Authors:
D. H. Lee,
S. Ajimura,
M. K. Cheoun,
J. H. Choi,
J. Y. Choi,
T. Dodo,
J. Goh,
K. Haga,
M. Harada,
S. Hasegawa,
T. Hiraiwa,
W. Hwang,
H. I. Jang,
J. S. Jang,
H. Jeon,
S. Jeon,
K. K. Joo,
D. E. Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim,
J. Y. Kim,
S. B. Kim,
W. Kim
, et al. (33 additional authors not shown)
Abstract:
JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment which searches for sterile neutrinos via the observation of $\barν_μ \to \barν_{e}$ appearance oscillations using muon decay-at-rest neutrinos. The data taking of JSNS$^2$ have been performed from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental back…
▽ More
JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment which searches for sterile neutrinos via the observation of $\barν_μ \to \barν_{e}$ appearance oscillations using muon decay-at-rest neutrinos. The data taking of JSNS$^2$ have been performed from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental background is (9.29$\pm 0.39) \times 10^{-8}$ / spill with 0.75 MW beam power and comparable to the number of searching signals.
△ Less
Submitted 22 April, 2024; v1 submitted 4 August, 2023;
originally announced August 2023.
-
Neural KEM: A Kernel Method with Deep Coefficient Prior for PET Image Reconstruction
Authors:
Siqi Li,
Kuang Gong,
Ramsey D. Badawi,
Edward J. Kim,
**yi Qi,
Guobao Wang
Abstract:
Image reconstruction of low-count positron emission tomography (PET) data is challenging. Kernel methods address the challenge by incorporating image prior information in the forward model of iterative PET image reconstruction. The kernelized expectation-maximization (KEM) algorithm has been developed and demonstrated to be effective and easy to implement. A common approach for a further improveme…
▽ More
Image reconstruction of low-count positron emission tomography (PET) data is challenging. Kernel methods address the challenge by incorporating image prior information in the forward model of iterative PET image reconstruction. The kernelized expectation-maximization (KEM) algorithm has been developed and demonstrated to be effective and easy to implement. A common approach for a further improvement of the kernel method would be adding an explicit regularization, which however leads to a complex optimization problem. In this paper, we propose an implicit regularization for the kernel method by using a deep coefficient prior, which represents the kernel coefficient image in the PET forward model using a convolutional neural-network. To solve the maximum-likelihood neural network-based reconstruction problem, we apply the principle of optimization transfer to derive a neural KEM algorithm. Each iteration of the algorithm consists of two separate steps: a KEM step for image update from the projection data and a deep-learning step in the image domain for updating the kernel coefficient image using the neural network. This optimization algorithm is guaranteed to monotonically increase the data likelihood. The results from computer simulations and real patient data have demonstrated that the neural KEM can outperform existing KEM and deep image prior methods.
△ Less
Submitted 24 October, 2022; v1 submitted 4 January, 2022;
originally announced January 2022.
-
The JSNS^2 Detector
Authors:
S. Ajimura,
M. Botran,
J. H. Choi,
J. W. Choi,
M. K. Cheoun,
T. Dodo,
H. Furuta,
J. Goh,
K. Haga,
M. Harada,
S. Hasegawa,
Y. Hino,
T. Hiraiwa,
H. I. Jang,
J. S. Jang,
M. C. Jang,
H. Jeon,
S. Jeon,
K. K. Joo,
J. R. Jordan,
D. E. Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim
, et al. (41 additional authors not shown)
Abstract:
The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator det…
▽ More
The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.
△ Less
Submitted 24 August, 2021; v1 submitted 27 April, 2021;
originally announced April 2021.
-
The JSNS$^{2}$ data acquisition system
Authors:
J. S. Park,
S. Ajimura,
M. Botran,
M. K. Cheoun,
J. H. Choi,
T. Dodo,
H. Furuta,
P. Gwak,
M. Harada,
S. Hasegawa,
Y. Hino,
T. Hiraiwa,
H. I. Jang,
J. S. Jang,
M. Jang,
H. Jeon,
S. Jeon,
K. K. Joo,
J. R. Jordan,
D. E. Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim,
J. Y. Kim
, et al. (36 additional authors not shown)
Abstract:
The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate $γ$-catcher and an optically separated outer veto volumes. A…
▽ More
The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate $γ$-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with the flash analog-to-digital converters. We present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.
△ Less
Submitted 31 May, 2020;
originally announced June 2020.
-
Performance of PMTs for the JSNS2 experiment
Authors:
J. S. Park,
H. Furuta,
T. Maruyama,
S. Monjushiro,
K. Nishikawa,
M. Taira,
J. S. Jang,
K. K. Joo,
J. Y. Kim,
I. T. Lim,
D. H. Moon,
J. H. Seo,
C. D. Shin,
A. Zohaib,
P. Gwak,
M. Jang,
S. Ajimura,
T. Hiraiwa,
T. Nakano,
M. Nomachi,
T. Shima,
Y. Sugaya,
M. K. Cheoun,
J. H. Choi,
M. Y. Pac
, et al. (36 additional authors not shown)
Abstract:
The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24\,m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate $γ$-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons fro…
▽ More
The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24\,m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate $γ$-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were purchased around 10 years ago, therefore JSNS$^{2}$ did pre-calibration of the PMTs including the purchased PMTs. 123 PMTs demonstrated acceptable performance for the JSNS$^{2}$ experiment, and 120 PMTs were installed in the detector.
△ Less
Submitted 25 May, 2020; v1 submitted 4 May, 2020;
originally announced May 2020.
-
Slow control and monitoring system at the JSNS$^{2}$
Authors:
J. S. Park,
S. Ajimura,
M. Botran,
J. H. Choi,
J. W. Choi,
M. K. Cheoun,
T. Dodo,
H. Furuta,
J. Goh,
M. Harada,
S. Hasegawa,
Y. Hino,
T. Hiraiwa,
H. I. Jang,
J. S. Jang,
M. C. Jang,
H. Jeon,
S. Jeon,
K. K. Joo,
J. R. Jordan,
D. E Jung,
S. K. Kang,
Y. Kasugai,
T. Kawasaki,
E. J. Kim
, et al. (37 additional authors not shown)
Abstract:
The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitor…
▽ More
The JSNS$^2$ experiment is aimed to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1\% gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage (HV) of the photomultiplier tubes (PMTs), the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in June 2020. In this paper, we present a description of the assembly and installation of the SCMS and its performance.
△ Less
Submitted 7 April, 2021; v1 submitted 4 May, 2020;
originally announced May 2020.
-
Approximate analytic solution of the potential flow around a rectangle
Authors:
Eunice J. Kim,
Ildoo Kim
Abstract:
In undergraduate classes, the potential flow that goes around a circular cylinder is designed for complemental understanding of mathematical technique to handle the Laplace equation with Neumann boundary conditions and the physical concept of the multipolar expansion. The simplicity of the standard problem is suited for the introductory level, however, it has a drawback. The discussion of higher o…
▽ More
In undergraduate classes, the potential flow that goes around a circular cylinder is designed for complemental understanding of mathematical technique to handle the Laplace equation with Neumann boundary conditions and the physical concept of the multipolar expansion. The simplicity of the standard problem is suited for the introductory level, however, it has a drawback. The discussion of higher order multipoles is often missed because the exact analytic solution contains only the dipole term. In this article, we present a modified problem of the potential flow around a rectangle as an advanced problem. Although the exact solution of this case is intractable, the approximate solution can be obtained by the discretization and the optimization using multiple linear regression. The suggested problem is expected to deepen the students' insight on the concept of multipoles and also provides an opportunity to discuss the formalism of the regression analysis, which in many physics curricula is lacking even though it has a significant importance in experimental physics.
△ Less
Submitted 28 June, 2019; v1 submitted 23 October, 2017;
originally announced October 2017.
-
Technical Design Report (TDR): Searching for a Sterile Neutrino at J-PARC MLF (E56, JSNS2)
Authors:
S. Ajimura,
M. K. Cheoun,
J. H. Choi,
H. Furuta,
M. Harada,
S. Hasegawa,
Y. Hino,
T. Hiraiwa,
E. Iwai,
S. Iwata,
J. S. Jang,
H. I. Jang,
K. K. Joo,
J. Jordan,
S. K. Kang,
T. Kawasaki,
Y. Kasugai,
E. J. Kim,
J. Y. Kim,
S. B. Kim,
W. Kim,
K. Kuwata,
E. Kwon,
I. T. Lim,
T. Maruyama
, et al. (28 additional authors not shown)
Abstract:
In this document, the technical details of the JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment are described.
The search for sterile neutrinos is currently one of the hottest topics in neutrino physics. The JSNS$^2$ experiment aims to search for the existence of neutrino oscillations with $Δm^2$ near 1 eV$^2$ at the J-PARC Materials and Life Science Exper…
▽ More
In this document, the technical details of the JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment are described.
The search for sterile neutrinos is currently one of the hottest topics in neutrino physics. The JSNS$^2$ experiment aims to search for the existence of neutrino oscillations with $Δm^2$ near 1 eV$^2$ at the J-PARC Materials and Life Science Experimental Facility (MLF). A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense neutrino beam from muon decay at rest. Neutrinos come predominantly from $μ^+$ decay: $μ^{+} \to e^{+} + \barν_μ + ν_{e}$. The experiment will search for $\barν_μ$ to $\barν_{e}$ oscillations which are detected by the inverse beta decay interaction $\barν_{e} + p \to e^{+} + n$, followed by gammas from neutron capture on Gd. The detector has a fiducial volume of 17 tons and is located 24 meters away from the mercury target. JSNS$^2$ offers the ultimate direct test of the LSND anomaly.
In addition to the sterile neutrino search, the physics program includes cross section measurements with neutrinos with a few 10's of MeV from muon decay at rest and with monochromatic 236 MeV neutrinos from kaon decay at rest. These cross sections are relevant for our understanding of supernova explosions and nuclear physics.
△ Less
Submitted 24 May, 2017;
originally announced May 2017.
-
Teaching Data Science
Authors:
Robert J. Brunner,
Edward J. Kim
Abstract:
We describe an introductory data science course, entitled Introduction to Data Science, offered at the University of Illinois at Urbana-Champaign. The course introduced general programming concepts by using the Python programming language with an emphasis on data preparation, processing, and presentation. The course had no prerequisites, and students were not expected to have any programming exper…
▽ More
We describe an introductory data science course, entitled Introduction to Data Science, offered at the University of Illinois at Urbana-Champaign. The course introduced general programming concepts by using the Python programming language with an emphasis on data preparation, processing, and presentation. The course had no prerequisites, and students were not expected to have any programming experience. This introductory course was designed to cover a wide range of topics, from the nature of data, to storage, to visualization, to probability and statistical analysis, to cloud and high performance computing, without becoming overly focused on any one subject. We conclude this article with a discussion of lessons learned and our plans to develop new data science courses.
△ Less
Submitted 25 April, 2016;
originally announced April 2016.
-
Long-lived neutral-kaon flux measurement for the KOTO experiment
Authors:
T. Masuda,
J. K. Ahn,
S. Banno,
M. Campbell,
J. Comfort,
Y. T. Duh,
T. Hineno,
Y. B. Hsiung,
T. Inagaki,
E. Iwai,
N. Kawasaki,
E. J. Kim,
Y. J. Kim,
J. W. Ko,
T. K. Komatsubara,
A. S. Kurilin,
G. H. Lee,
J. W. Lee,
S. K. Lee,
G. Y. Lim,
J. Ma,
D. MacFarland,
Y. Maeda,
T. Matsumura,
R. Murayama
, et al. (32 additional authors not shown)
Abstract:
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$,…
▽ More
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.
△ Less
Submitted 7 January, 2016; v1 submitted 11 September, 2015;
originally announced September 2015.
-
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
J. Schlereth,
L. Xia,
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
G. Eigen,
Y. Mikami,
T. Price,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
C. Cârloganu,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh
, et al. (127 additional authors not shown)
Abstract:
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable ove…
▽ More
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
△ Less
Submitted 8 May, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
Non-specific cellular uptake of surface-functionalized quantum dots
Authors:
T A Kelf,
V K A Sreenivasan,
J Sun,
E J Kim,
E M Goldys,
A V Zvyagin
Abstract:
We report a systematic empirical study of nanoparticle internalization into cells via non-specific pathways. The nanoparticles were comprised of commercial quantum dots (QDs) that were highly visible under a fluorescence confocal microscope. Surface-modified QDs with basic biologically-significant moieties, e.g. carboxyl, amino, streptavidin were used, in combination with the surface derivatizatio…
▽ More
We report a systematic empirical study of nanoparticle internalization into cells via non-specific pathways. The nanoparticles were comprised of commercial quantum dots (QDs) that were highly visible under a fluorescence confocal microscope. Surface-modified QDs with basic biologically-significant moieties, e.g. carboxyl, amino, streptavidin were used, in combination with the surface derivatization with polyethylene glycol (PEG) in a range of immortalized cell lines. Internalization rates were derived from image analysis and a detailed discussion about the effect of nanoparticle size, charge and surface groups is presented. We find that PEG-derivatization dramatically suppresses the non-specific uptake while PEG-free carboxyl and amine functional groups promote QD internalization. These uptake variations displayed a remarkable consistency across different cell types. The reported results are important for experiments concerned with cellular uptake of surface-functionalized nanomaterials, both when non-specific internalization is undesirable and also when it is intended for material to be internalized as efficiently as possible.
Published article at: http://iopscience.iop.org/0957-4484/21/28/285105/
△ Less
Submitted 28 June, 2010;
originally announced June 2010.
-
Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Ribon,
V. Uzhinskiy,
M. Benyamna,
C. Cârloganu,
F. Fehr,
P. Gay,
G. C. Blazey,
D. Chakraborty
, et al. (133 additional authors not shown)
Abstract:
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the…
▽ More
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.
△ Less
Submitted 28 April, 2010;
originally announced April 2010.
-
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
A. Brandt,
H. Brown,
K. De,
C. Medina,
J. Smith,
J. Li,
M. Sosebee,
A. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada
, et al. (205 additional authors not shown)
Abstract:
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.…
▽ More
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.
△ Less
Submitted 12 March, 2010;
originally announced March 2010.