Skip to main content

Showing 1–6 of 6 results for author: Kim, B R

Searching in archive physics. Search in all archives.
.
  1. arXiv:1610.05134  [pdf, other

    hep-ex physics.ins-det

    Sterile neutrino search at NEOS Experiment

    Authors: Y. J. Ko, B. R. Kim, J. Y. Kim, B. Y. Han, C. H. Jang, E. J. Jeon, K. K. Joo, H. J. Kim, H. S. Kim, Y. D. Kim, Jaison Lee, J. Y. Lee, M. H. Lee, Y. M. Oh, H. K. Park, H. S. Park, K. S. Park, K. M. Seo, Kim Siyeon, G. M. Sun

    Abstract: An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of abou… ▽ More

    Submitted 21 March, 2017; v1 submitted 17 October, 2016; originally announced October 2016.

    Comments: 6 pages, 4 figures. 1 supplemental material (Fig. S1). Version published in Physical Review Letters

    Journal ref: Phys. Rev. Lett. 118, 121802 (2017)

  2. arXiv:1610.05111  [pdf, other

    physics.ins-det nucl-ex

    Measurement of Fast Neutron Rate for NEOS Experiment

    Authors: Y. J. Ko, J. Y. Kim, B. Y. Han, C. H. Jang, E. J. Jeon, K. K. Joo, B. R. Kim, H. J. Kim, H. S. Kim, Y. D. Kim, Jaison Lee, J. Y. Lee, M. H. Lee, Y. M. Oh, H. K. Park, H. S. Park, K. S. Park, K. M. Seo, Kim Siyeon, G. M. Sun

    Abstract: The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day fo… ▽ More

    Submitted 17 October, 2016; originally announced October 2016.

    Comments: To be submitted to JKPS

  3. arXiv:1610.04326  [pdf, other

    hep-ex physics.ins-det

    Spectral Measurement of the Electron Antineutrino Oscillation Amplitude and Frequency using 500 Live Days of RENO Data

    Authors: S. H. Seo, W. Q. Choi, H. Seo, J. H. Choi, Y. Choi, H. I. Jang, J. S. Jang, K. K. Joo, B. R. Kim, H. S. Kim, J. Y. Kim, S. B. Kim, S. Y. Kim, W. Kim, E. Kwon, D. H. Lee, Y. C. Lee, I. T. Lim, M. Y. Pac, I. G. Park, J. S. Park, R. G. Park, Y. G. Seon, C. D. Shin, J. H. Yang , et al. (3 additional authors not shown)

    Abstract: The Reactor Experiment for Neutrino Oscillation (RENO) has been taking electron antineutrino ($\overlineν_{e}$) data from the reactors in Yonggwang, Korea, using two identical detectors since August 2011. Using roughly 500 live days of data through January 2013 we observe 290,775 (31,514) reactor $\overlineν_{e}$ candidate events with 2.8 (4.9)% background in the near (far) detector. The observed… ▽ More

    Submitted 16 May, 2018; v1 submitted 14 October, 2016; originally announced October 2016.

    Comments: 24 pages, 30 figures. Submitted to PRD. Total detection efficiency change from 76.44% to 76.47%. Some modifications of text to improve readability and clarification of the paper

    Journal ref: Phys. Rev. D 98, 012002 (2018)

  4. arXiv:1609.09483  [pdf, other

    physics.ins-det hep-ex

    In-Situ Measurement of Relative Attenuation Length of Gadolinium-Loaded Liquid Scintillator Using Source Data at RENO Experiment

    Authors: H. S. Kim, S. Y. Kim, J. H. Choi, W. Q. Choi, Y. Choi, H. I. Jang, J. S. Jang, K. K. Joo, B. R. Kim, J. Y. Kim, S. B. Kim, W. Kim, E. Kwon, D. H. Lee, I. T. Lim, M. Y. Pac, I. G. Park, J. S. Park, R. G. Park, H. Seo, S. H. Seo, Y. G. Seon, C. D. Shin, I. S. Yeo, I. Yu

    Abstract: We present in situ measurements of the relative attenuation length of the gadolinium loaded liquid scintillator in the RENO (Reactor Experiment Neutrino Oscillation) detectors using radioactive source calibration data. We observed a steady decrease in the attenuation length of the Gd-LS in the RENO detectors by 50% in about four years since the commissioning of the detectors.

    Submitted 22 May, 2023; v1 submitted 29 September, 2016; originally announced September 2016.

    Comments: 11 pages, 5 figures

  5. arXiv:1511.05551  [pdf

    physics.ins-det hep-ex

    Development and Mass Production of a Mixture of LAB- and DIN-based Gadolinium-loaded Liquid Scintillator for the NEOS Short-baseline Neutrino Experiment

    Authors: Ba Ro Kim, Boyoung Han, Eun-ju Jeon, Kyung Kwang Joo, H. J. Kim, Hyunsoo Kim, **yu Kim, Yeongduk Kim, Youngju Ko, Jaison Lee, Jooyoung Lee, Moohyun Lee, Kyungju Ma, Yoomin Oh, Hyangkyu Park, Kang-soon Park, Kyungmin Seo, Gwang-Min Seon, Kim Siyeon

    Abstract: A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base… ▽ More

    Submitted 16 November, 2015; originally announced November 2015.

  6. arXiv:1307.0908  [pdf, other

    physics.ins-det hep-ex

    Slow Control Systems of the Reactor Experiment for Neutrino Oscillation

    Authors: J. H. Choi, H. I. Jang, W. Q. Choi, Y. Choi, J. S. Jang, E. J. Jeon, K. K. Joo, B. R. Kim, H. S. Kim, J. Y. Kim, S. B. Kim, S. Y. Kim, W. Kim, Y. D. Kim, Y. J. Ko, J. K. Lee, I. T. Lim, M. Y. Pac, I. G. Park, J. S. Park, R. G. Park, H. K. Seo, C. D. Shin, K. Siyeon, I. S. Yeo , et al. (1 additional authors not shown)

    Abstract: The RENO experiment has been in operation since August 2011 to measure reactor antineutrino disappearance using identical near and far detectors. For accurate measurements of neutrino mixing parameters and efficient data taking, it is crucial to monitor and control the detector in real time. Environmental conditions also need to be monitored for stable operation of detectors as well as for safety… ▽ More

    Submitted 9 December, 2015; v1 submitted 2 July, 2013; originally announced July 2013.