-
Applying triangular correlation of angular deviation in muon scattering tomography for multi-block materials via GEANT4 simulations
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco
Abstract:
The scattering angle due to the target volume can be split into two interior angles in the tomographic setups based on the muon scattering, and we call this property as the triangular correlation where the sum of these two interior angles is equal to the scattering angle. In this study, we apply this triangular correlation for a multi-block material configuration that consist of concrete, stainles…
▽ More
The scattering angle due to the target volume can be split into two interior angles in the tomographic setups based on the muon scattering, and we call this property as the triangular correlation where the sum of these two interior angles is equal to the scattering angle. In this study, we apply this triangular correlation for a multi-block material configuration that consist of concrete, stainless steel, and uranium. By changing the order of this material set, we employ the GEANT4 simulations and we show that the triangular correlation is valid in the multi-block material setups, thereby providing the possibility of supportive information for the coarse prediction of the material order in such configurations.
△ Less
Submitted 29 December, 2022; v1 submitted 25 October, 2022;
originally announced December 2022.
-
Investigation of deflection angle for muon energy classification in muon scattering tomography via GEANT4 simulations
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco,
Mart Magi
Abstract:
In muon scattering tomography, the investigated materials are discriminated according to the scattering angle that mainly depends on the atomic number, the density, and the thickness of the medium at a given energy value. The scattering angles at different initial energies also provide the opportunity to classify the incoming muons into a number of energy groups. In this study, by employing the GE…
▽ More
In muon scattering tomography, the investigated materials are discriminated according to the scattering angle that mainly depends on the atomic number, the density, and the thickness of the medium at a given energy value. The scattering angles at different initial energies also provide the opportunity to classify the incoming muons into a number of energy groups. In this study, by employing the GEANT4 code, we show that the deflection angle exponentially decays as a function of energy, and the numerical values for the current configuration are below the detector accuracy except the initial energy bins owing to the low-Z, low density, and low thickness of the current plastic scintillators. This implies the necessity of additional components that provoke the muon scattering. Therefore, we introduce stainless steel surfaces into the top and bottom sections in order to amplify the deflection angle as well as to reduce the uncertainty, thereby improving the detector performance.
△ Less
Submitted 13 April, 2022;
originally announced April 2022.
-
DOME: Discrete oriented muon emission in GEANT4 simulations
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco
Abstract:
In this study, we exhibit a number elementary strategies that might be at disposal in diverse computational applications in the GEANT4 simulations with the purpose of hemispherical particle sources. To further detail, we initially generate random points on a spherical surface for a sphere of a practical radius by employing Gaussian distributions for the three components of the Cartesian coordinate…
▽ More
In this study, we exhibit a number elementary strategies that might be at disposal in diverse computational applications in the GEANT4 simulations with the purpose of hemispherical particle sources. To further detail, we initially generate random points on a spherical surface for a sphere of a practical radius by employing Gaussian distributions for the three components of the Cartesian coordinates, thereby obtaining a generating surface for the initial positions of the corresponding particles. Since we do not require the half bottom part of the produced spherical surface for our tomographic applications, we take the absolute value of the vertical component in the Cartesian coordinates by leading to a half-spherical shell, which is traditionally called a hemisphere. Last but not least, we direct the generated particles into the target material to be irradiated by favoring a selective momentum direction that is based on the vector construction between the random point on the hemispherical surface and the origin of the target material, hereby optimizing the particle loss through the source biasing. In the end, we incorporate our strategy by using G4ParticleGun in the GEANT4 code. Furthermore, we also exhibit a second scheme that is based on the coordinate transformation from the spherical coordinates to the Cartesian coordinates, thereby reducing the number of random number generators. While we plan to exert our strategy in the computational practices for muon scattering tomography, this source scheme might find its straightforward applications in different neighboring fields including but not limited to atmospheric sciences, space engineering, and astrophysics where a 3D particle source is a necessity for the modeling goals.
△ Less
Submitted 7 April, 2023; v1 submitted 18 February, 2022;
originally announced February 2022.
-
Towards energy discretization for muon scattering tomography in GEANT4 simulations: A discrete probabilistic approach
Authors:
Ahmet Ilker Topuz,
Madis Kiisk
Abstract:
In this study, by attempting to eliminate the disadvantageous complexity of the existing particle generators, we present a discrete probabilistic scheme adapted for the discrete energy spectra in the GEANT4 simulations. In our multi-binned approach, we initially compute the discrete probabilities for each energy bin, the number of which is flexible depending on the computational goal, and we solel…
▽ More
In this study, by attempting to eliminate the disadvantageous complexity of the existing particle generators, we present a discrete probabilistic scheme adapted for the discrete energy spectra in the GEANT4 simulations. In our multi-binned approach, we initially compute the discrete probabilities for each energy bin, the number of which is flexible depending on the computational goal, and we solely satisfy the imperative condition that requires the sum of the discrete probabilities to be the unity. Regarding the implementation in GEANT4, we construct a one-dimensional probability grid that consists of sub-cells equaling the number of the energy bin, and each cell represents the discrete probability of each energy bin by fulfilling the unity condition. Through uniformly generating random numbers between 0 and 1, we assign the discrete energy in accordance with the associated generated random number that corresponds to a specific cell in the probability grid. This probabilistic methodology does not only permits us to discretize the continuous energy spectra based on the Monte Carlo generators, but it also gives a unique access to utilize the experimental energy spectra measured at the distinct particle flux values. Ergo, we initially perform our simulations by discretizing the muon energy spectrum acquired via the CRY generator over the energy interval between 0 and 8 GeV along with the measurements from the BESS spectrometer and we determine the average scattering angle, the root-mean-square of the scattering angle, and the number of the muon absorption by using a series of slabs consisting of aluminum, copper, iron, lead, and uranium. Eventually, we express a computational strategy in the GEANT4 simulations that grants us the ability to verify as well as to modify the energy spectrum depending on the nature of the information source in addition to the exceptional tracking speed.
△ Less
Submitted 21 January, 2022;
originally announced January 2022.
-
Particle generation through restrictive planes in GEANT4 simulations for potential applications of cosmic ray muon tomography
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco
Abstract:
In this study, by attempting to resolve the angular complication during the particle generation for the muon tomography applications in the GEANT4 simulations, we exhibit an unconventional methodology that is hinged on the direction limitation via the vectorial construction from the generation location to the restriction area rather than using a certain angular distribution or interval. In other w…
▽ More
In this study, by attempting to resolve the angular complication during the particle generation for the muon tomography applications in the GEANT4 simulations, we exhibit an unconventional methodology that is hinged on the direction limitation via the vectorial construction from the generation location to the restriction area rather than using a certain angular distribution or interval. In other words, we favor a momentum direction that is determined by a vector constructed between an initial point randomly chosen on a generative point/plane and a latter point arbitrarily selected on a restrictive plane of the same dimensions with the basal cross section of the volume-of-interest (VOI). On account of setting out such a generation scheme, we optimize the particle loss by kee** an angular disparity that is directly dependent on the VOI geometry as well as the vertical position of the restrictive plane for a tomographic system of a finite size. We demonstrate our strategy for a set of target materials including aluminum, copper, iron, lead, and uranium with a dimension of 40$\times$10$\times$40 $\rm cm^{3}$ over three restrictive planes of different positions by using a discrete energy spectrum between 0.1 and 8 GeV and we compute the scattering angle, the number of absorption, and the particle loss. Upon our simulation outcomes, we show that the particle generation by means of restrictive planes is an effective strategy that is flexible towards a variety of computational objectives in the GEANT4 simulations.
△ Less
Submitted 20 January, 2022; v1 submitted 18 January, 2022;
originally announced January 2022.
-
On muon energy group structure based on deflection angle for application in muon scattering tomography: A Monte Carlo study through GEANT4 simulations
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco,
Mart Magi
Abstract:
The average deflection angle of the tracked muons in the muon scattering tomography exponentially declines in function of the initial kinetic energy, the angular dependence of which provides an opportunity to set out a binary relation between the initial kinetic energy and the average deflection angle, thereby leading to a coarse energy prediction founded on the mean deflection angle in the case o…
▽ More
The average deflection angle of the tracked muons in the muon scattering tomography exponentially declines in function of the initial kinetic energy, the angular dependence of which provides an opportunity to set out a binary relation between the initial kinetic energy and the average deflection angle, thereby leading to a coarse energy prediction founded on the mean deflection angle in the case of experimental incapabilities or limitations. In this study, we address the problem of the muon energy classification for a tomographic system consisting of 0.4-cm plastic scintillators manufactured from polyvinyl toluene and we explore a four-group structure besides a ternary partitioning between 0.25 and 8 GeV. In the first instance, we determine the deflection angles by tracking the hit locations in the detector layers on the sub-divided uniform energy intervals through the GEANT4 simulations. In the latter step, we express two misclassification probabilities where the first approach assumes a symmetrical linear propagation bounded by one standard deviation in one dimension, whereas the second procedure employs a positively defined modified Gaussian distribution that governs the overlap** area in two dimensions. In the final stage, we compare qualitatively and quantitatively the adjacent energy groups by using the computed misclassification probabilities. In the absence of any further data manipulation, we explicitly show that the misclassification probabilities increase when the number of energy groups augments. Furthermore, we also conclude that it is feasible to benefit from the mean deflection angle to roughly estimate the muon energies up to four energy groups by taking the misclassification probabilities into consideration, while the classification viability significantly diminishes when the partition number exceeds four on the basis of standard deviation.
△ Less
Submitted 10 December, 2021;
originally announced December 2021.
-
Unveiling triangular correlation of angular deviation in muon scattering tomography by means of GEANT4 simulations
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco,
Mart Magi
Abstract:
The angular deviation commonly represented by the scattering angle generally serves to provide the characteristic discrimination in the muon scattering tomography. The regular procedure to determine the scattering angle comprises the collection of exactly four hit locations in four detector layers among which two top detector layers are utilized to construct the first vector, whereas the second ve…
▽ More
The angular deviation commonly represented by the scattering angle generally serves to provide the characteristic discrimination in the muon scattering tomography. The regular procedure to determine the scattering angle comprises the collection of exactly four hit locations in four detector layers among which two top detector layers are utilized to construct the first vector, whereas the second vector is built by using two bottom detector layers. Although this procedure acts to classify the target volumes in the tomographic systems based on the muon scattering, the scattering angle obtained through the usual methodology founded on four detector layers is dubious for not yielding any information about the position of target volume. Nonetheless, the same set of four detector layers also imparts the possibility of splitting the scattering angle into two separate angles by creating a triangular correlation in such a way that the scattering angle is referred to an exterior angle, whereas the separate angles are considered the interior opposite angles that are not neighboring this exterior angle. In this study, we first show that a combination of three detector layers out of four fulfills the calculation of the interior opposite angles. Then, by employing the GEANT4 simulations over our tomographic configuration composed of three plastic scintillators in either section, we demonstrate that the interior opposite angles differ towards the vertical spatial variation, while the exterior angle approximately remains constant, thereby implying a beneficial feature to be used for the image reconstruction purposes.
△ Less
Submitted 2 December, 2021; v1 submitted 1 December, 2021;
originally announced December 2021.
-
Effect of passive metallic layers on muon energy estimation by means of deflection angle for muon scattering tomography: A comparative study based on GEANT4 simulations
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco,
Mart Magi
Abstract:
In the tomographic configurations based on the muon scattering, the angular variation with respect to the kinetic energy indirectly brings forth the ability to coarsely predict the kinetic energy by using the deflection angle owing to the detector layers. Nevertheless, the angular deviation due to the detector components is expected to be minuscule in addition to a relatively high uncertainty in t…
▽ More
In the tomographic configurations based on the muon scattering, the angular variation with respect to the kinetic energy indirectly brings forth the ability to coarsely predict the kinetic energy by using the deflection angle owing to the detector layers. Nevertheless, the angular deviation due to the detector components is expected to be minuscule in addition to a relatively high uncertainty in the case of the plastic scintillators. In the present study, we contrast our current tomographic prototype, which consists of the detector layers manufactured from polyvinyl toluene besides a detector accuracy of 1 mrad, with an alternative hodoscope scheme containing stainless steel layers by aiming to investigate the three-group energy structure. Initially, we determine the average deflection angles together with the corresponding standard deviations for our present setup as well as for the alternative scheme by means of the GEANT4 simulations. In the second place, we express a brace of misclassification probabilities founded on the standard deviations where the first procedure assumes a linear finite approximation, whereas the latter approach rests on a positively defined modified Gaussian distribution. Upon our simulation results, we demonstrate that the introduced stainless steel layers in the proposed hodoscope setup do not only serve to augment the average deflection angles, but they also diminish the misclassification probabilities, therewith reducing the classification uncertainty apart from an improved detection performance.
△ Less
Submitted 3 December, 2021; v1 submitted 22 September, 2021;
originally announced September 2021.
-
Non-destructive interrogation of nuclear waste barrels through muon tomography: A Monte Carlo study based on dual-parameter analysis via GEANT4 simulations
Authors:
Ahmet Ilker Topuz,
Madis Kiisk,
Andrea Giammanco
Abstract:
In this study, we employ the Monte Carlo simulations by using the GEANT4 code to demonstrate the capability of muon tomography based on the dual-parameter analysis in the examination of the nuclear waste barrels. Our current hodoscope setup consists of three top and three bottom plastic scintillators made of polyvinyl toluene with the thickness of 0.4 cm, and the composite target material is a cyl…
▽ More
In this study, we employ the Monte Carlo simulations by using the GEANT4 code to demonstrate the capability of muon tomography based on the dual-parameter analysis in the examination of the nuclear waste barrels. Our current hodoscope setup consists of three top and three bottom plastic scintillators made of polyvinyl toluene with the thickness of 0.4 cm, and the composite target material is a cylindrical nuclear waste drum with the height of 96 cm and the radius of 29.6 cm where the outermost layer is stainless steel with the lateral thickness of 3.2 cm and the filling material is ordinary concrete that encapsulates the nuclear materials of dimensions 20$\times$20$\times$20 cm$^{3}$. By simulating with a narrow planar muon beam of 1$\times$1 cm$^{2}$ over the uniform energy interval between 0.1 and 8 GeV, we determine the variation of the average scattering angle together with the standard deviation by utilizing a 0.5-GeV bin length, the counts of the scattering angle by using a 1-mrad step, and the number of the absorption events for the five prevalent nuclear materials starting from cobalt and ending in plutonium. Via the duo-parametric analysis that is founded on the scattering angle as well as the absorption in the present study, we show that the presence of the nuclear materials in the waste barrels is numerically visible in comparison with the concrete-filled waste drum without any nuclear material, and the muon tomography is capable of distinguishing these nuclear materials by coupling the information about the scattering angle and the number of absorption in the cases where one of these two parameters yields strong similarity for certain nuclear materials.
△ Less
Submitted 18 October, 2022; v1 submitted 27 June, 2021;
originally announced June 2021.
-
Atmospheric ray tomography for low-Z materials: implementing new methods on a proof-of-concept tomograph
Authors:
Gholamreza Anbarjafari,
Aivo Anier,
Egils Avots,
Anzori Georgadze,
Andi Hektor,
Madis Kiisk,
Marius Kutateladze,
Tõnu Lepp,
Märt Mägi,
Vitali Pastsuk,
Hannes Plinte,
Sander Suurpere
Abstract:
Cosmic rays interacting with the atmosphere result in a flux of secondary particles including muons and electrons. Atmospheric ray tomography (ART) uses the muons and electrons for detecting objects and their composition. This paper presents new methods and a proof-of-concept tomography system developed for the ART of low-Z materials. We introduce the Particle Track Filtering (PTF) and Multi-Modal…
▽ More
Cosmic rays interacting with the atmosphere result in a flux of secondary particles including muons and electrons. Atmospheric ray tomography (ART) uses the muons and electrons for detecting objects and their composition. This paper presents new methods and a proof-of-concept tomography system developed for the ART of low-Z materials. We introduce the Particle Track Filtering (PTF) and Multi-Modality Tomographic Reconstruction (MMTR) methods. Based on Geant4 models we optimized the tomography system, the parameters of PTF and MMTR. Based on plastic scintillating fiber arrays we achieved the spatial resolution 120 $μ$m and 1 mrad angular resolution in the track reconstruction. We developed a novel edge detection method to separate the logical volumes of scanned object. We show its effectiveness on single (e.g. water, aluminum) and double material (e.g. explosive RDX in flesh) objects. The tabletop tomograph we built showed excellent agreement between simulations and measurements. We are able to increase the discriminating power of ART on low-Z materials significantly. This work opens up new routes for the commercialization of ART tomography.
△ Less
Submitted 1 March, 2021; v1 submitted 24 February, 2021;
originally announced February 2021.