ECFA Detector R&D Panel, Review Report
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
P. Bambade,
L. Bortko,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
A. Dragone,
L. Dumitru,
K. Elsener,
I. Emeliantchik,
E. Firu,
J. Fischer,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
G. Grzelak,
G. Haller,
H. Henschel
, et al. (46 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
△ Less
Submitted 19 November, 2014; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Luminometer for the future International Linear Collider - simulation and beam test results
Authors:
J. A. Aguilar,
S. Kulis,
W. Wierba,
L. Zawiejski,
E. Kielar,
M. Chrzaszcz,
O. Novgorodova,
H. Henschel,
W. Lohmann,
S. Schuwalow,
K. Afanaciev,
A. Ignatenko,
S. Kollowa,
I. Levy,
M. Idzik,
J. Kotula,
A. Moszczynski,
K. Oliwa,
B. Pawlik,
W. Daniluk
Abstract:
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter module…
▽ More
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter modules placed symmetrically on opposite sides of the interaction point. To meet these goals, the energy resolution of the calorimeter must be better than 1.5% at high energies. LumiCal has been designed as a 30-layer sampling calorimeter with tungsten as the passive material and silicon as the active material. Monte Carlo simulation using the Geant4 software framework has been used to identify design elements which adversely impact energy resolution and correct for them without loss of statistics. BeamCal, covering polar angles smaller than LumiCal, will serve for beam tuning, luminosity optimisation and high energy electron detection. Secondly, prototypes of the sensors and electronics for both detectors have been evaluated during beam tests, the results of which are also presented here.
△ Less
Submitted 22 November, 2011;
originally announced November 2011.
-
Forward Instrumentation for ILC Detectors
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstantin Afanaciev,
Jonathan Aguilar,
Prasoon Ambalathankandy,
Philip Bambade,
Matthias Bergholz,
Ivanka Bozovic-Jelisavcic,
Elena Castro,
Georgy Chelkov,
Cornelia Coca,
Witold Daniluk,
Angelo Dragone,
Laurentiu Dumitru,
Konrad Elsener,
Igor Emeliantchik,
Tomasz Fiutowski,
Mikhail Gostkin,
Christian Grah,
Grzegorz Grzelak,
Gunter Haller,
Hans Henschel,
Alexandr Ignatenko,
Marek Idzik,
Kazutoshi Ito
, et al. (33 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.
△ Less
Submitted 3 November, 2010; v1 submitted 13 September, 2010;
originally announced September 2010.