-
Spatial coherence of synchrotron radiation degraded by grating monochromators
Authors:
Ruslan Khubbutdinov,
Gianluca Geloni,
Evgeny Saldin,
Kai Bagschik
Abstract:
In this work, we present a physical and theoretical description of the significant degradation of X-ray spatial coherence properties due to the use of grating monochromators at synchrotron facilities. We present a comprehensive study of the effects of spatial coherence degradation as a function of grating parameters under different focusing and propagation conditions. The focus is on the effect of…
▽ More
In this work, we present a physical and theoretical description of the significant degradation of X-ray spatial coherence properties due to the use of grating monochromators at synchrotron facilities. We present a comprehensive study of the effects of spatial coherence degradation as a function of grating parameters under different focusing and propagation conditions. The focus is on the effect of spatial coherence degradation caused by the grating alone, starting from a fully coherent incident photon beam generated by a filament source. The mathematical description and theoretical analysis of the spatial coherence degradation is presented in the framework of statistical optics.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Statistical analysis of hard X-ray radiation at PAL-XFEL facility performed by Hanbury Brown and Twiss interferometry
Authors:
Young Yong Kim,
Ruslan Khubbutdinov,
Jerome Carnis,
Sangsoo Kim,
Daewoong Nam,
Inhyuk Nam,
Gyu** Kim,
Chi Hyun Shim,
Haeryong Yang,
Myunghoon Cho,
Chang-Ki Min,
Changbum Kim,
Heung-Sik Kang,
Ivan Vartanyants
Abstract:
Hanbury Brown and Twiss interferometry experiment based on second-order correlations was performed at PAL-XFEL facility. The statistical properties of the X-ray radiation were studied within this experiment. Measurements were performed at NCI beamline at 10 keV photon energy in various operation conditions: Self-Amplified Spontaneous Emission (SASE), SASE with a monochromator, and self-seeding reg…
▽ More
Hanbury Brown and Twiss interferometry experiment based on second-order correlations was performed at PAL-XFEL facility. The statistical properties of the X-ray radiation were studied within this experiment. Measurements were performed at NCI beamline at 10 keV photon energy in various operation conditions: Self-Amplified Spontaneous Emission (SASE), SASE with a monochromator, and self-seeding regimes at 120 pC, 180 pC, and 200 pC electron bunch charge, respectively. Statistical analysis showed short average pulse duration from 6 fs to 9 fs depending on operation conditions. A high spatial degree of coherence of about 70-80% was determined in spatial domain for the SASE beams with the monochromator and self-seeding regime of operation. The obtained values describe the statistical properties of the beams generated at PAL-XFEL facility.
△ Less
Submitted 25 March, 2022;
originally announced March 2022.
-
High spatial coherence and short pulse duration revealed by the Hanbury Brown and Twiss interferometry at the European XFEL
Authors:
Ruslan Khubbutdinov,
Natalia Gerasimova,
Giuseppe Mercurio,
Dameli Assalauova,
Jerome Carnis,
Luca Gelisio,
Loïc le Guyader,
Alexandr Ignatenko,
Young Yong Kim,
Benjamin van Kuiken,
Ruslan P. Kurta,
Dmitry Lapkin,
Martin Teichmann,
Alexander Yaroslavtsev,
Oleg Gorobtsov,
Aleksey P. Menushenkov,
Matthias Scholz,
Andreas Scherz,
Ivan A. Vartanyants
Abstract:
Second-order intensity interferometry was employed to study the spatial and temporal properties of the European X-ray Free-Electron Laser (EuXFEL). Measurements were performed at the soft X-ray SASE3 undulator beamline at a photon energy of 1.2 keV in the Self-Amplified Spontaneous Emission (SASE) mode. Two high-power regimes of the SASE3 undulator settings, i.e. linear and quadratic tapering at s…
▽ More
Second-order intensity interferometry was employed to study the spatial and temporal properties of the European X-ray Free-Electron Laser (EuXFEL). Measurements were performed at the soft X-ray SASE3 undulator beamline at a photon energy of 1.2 keV in the Self-Amplified Spontaneous Emission (SASE) mode. Two high-power regimes of the SASE3 undulator settings, i.e. linear and quadratic tapering at saturation, were studied in detail and compared with the linear gain regime. The statistical analysis showed an exceptionally high degree of spatial coherence up to 90% for the linear undulator tapering. Analysis of the measured data in spectral and spatial domains provided an average pulse duration of about 10 fs in our measurements. The obtained results will be valuable for the experiments requiring and exploiting short pulse duration and utilizing high coherence properties of the EuXFEL.
△ Less
Submitted 22 April, 2021;
originally announced April 2021.
-
Theoretical Analysis of Hanbury Brown and Twiss Interferometry at Soft X-ray Free-Electron Lasers
Authors:
Ivan A. Vartanyants,
Ruslan Khubbutdinov
Abstract:
In this work we provide theoretical background for the analysis of second-order correlation functions in experiments performed at the soft x-ray free-electron lasers (XFELs). Typically, soft x-ray beamlines at XFELs are equipped by the variable line spacing (VLS) monochromators. We perform examination of the beam propagation through such VLS monochromator taking specially into account the interpla…
▽ More
In this work we provide theoretical background for the analysis of second-order correlation functions in experiments performed at the soft x-ray free-electron lasers (XFELs). Typically, soft x-ray beamlines at XFELs are equipped by the variable line spacing (VLS) monochromators. We perform examination of the beam propagation through such VLS monochromator taking specially into account the interplay between the finite monochromator resolution and the exit slits width. We then provide general analysis of the second-order correlation intensities in spectral and spatial domains. Finally, we connect these functions with the statistical properties of the beam incoming to the monochromator unit in the limit of Gaussian Schell-model pulses.
△ Less
Submitted 9 April, 2021;
originally announced April 2021.
-
An advanced workflow for single particle imaging with the limited data at an X-ray free-electron laser
Authors:
Dameli Assalauova,
Young Yong Kim,
Sergey Bobkov,
Ruslan Khubbutdinov,
Max Rose,
Roberto Alvarez,
Jakob Andreasson,
Eugeniu Balaur,
Alice Contreras,
Hasan DeMirci,
Luca Gelisio,
Janos Hajdu,
Mark S. Hunter,
Ruslan P. Kurta,
Haoyuan Li,
Matthew McFadden,
Reza Nazari,
Peter Schwander,
Anton Teslyuk,
Peter Walter,
P. Lourdu Xavier,
Chun Hong Yoon,
Sahba Zaared,
Viacheslav A. Ilyin,
Richard A. Kirian
, et al. (3 additional authors not shown)
Abstract:
An improved analysis for single particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the AMO instrument at the Linac Coherent Light Source (LCLS) as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from the half…
▽ More
An improved analysis for single particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the AMO instrument at the Linac Coherent Light Source (LCLS) as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from the half of the detector and small fraction of single hits. General SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus structure determination step. The presented processing pipeline allowed us to determine the three-dimensional structure of the bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.
△ Less
Submitted 15 June, 2020;
originally announced June 2020.
-
Coherence properties of the high-energy fourth-generation X-ray synchrotron sources
Authors:
R. Khubbutdinov,
A. P. Menushenkov,
I. A. Vartanyants
Abstract:
We performed an analysis of coherence properties of the 4-th generation high-energy storage rings with emittance values of 10 pmrad. It is presently expected that a storage ring with these low emittance values will reach diffraction limit at hard X-rays. Simulations of coherence properties were performed with the XRT software and analytical approach for different photon energies from 500 eV to 50…
▽ More
We performed an analysis of coherence properties of the 4-th generation high-energy storage rings with emittance values of 10 pmrad. It is presently expected that a storage ring with these low emittance values will reach diffraction limit at hard X-rays. Simulations of coherence properties were performed with the XRT software and analytical approach for different photon energies from 500 eV to 50 keV. It was demonstrated that a minimum photon emittance (diffraction limit) reached at such storage rings is λ/2π. Using mode decomposition we showed that at the parameters of the storage ring considered in this work, diffraction limit will be reached for soft X-ray energies of 500 eV. About ten modes will contribute to the radiation field at 12 keV photon energy and even more modes give a contribution at higher photon energies. Energy spread effects of the electron beam in a low emittance storage ring were analysed in detail. Simulations were performed at different relative energy spread values from zero to 0.2%. We observed a decrease of the degree of coherence with an increase of the relative energy spread value. Our analysis shows that to reach diffraction limit for high photon energies electron beam emittance should go down to 1 pmrad and below.
△ Less
Submitted 8 July, 2019;
originally announced July 2019.
-
Ghost Imaging at an XUV Free-Electron Laser
Authors:
Young Yong Kim,
Luca Gelisio,
Giuseppe Mercurio,
Siarhei Dziarzhytski,
Martin Beye,
Lars Bocklage,
Anton Classen,
Christian David,
Oleg Yu. Gorobtsov,
Ruslan Khubbutdinov,
Sergey Lazarev,
Nastasia Mukharamova,
Yury N. Obukhov,
Benedikt Roesner,
Kai Schlage,
Ivan A. Zaluzhnyy,
Guenter Brenner,
Ralf Roehlsberger,
Joachim von Zanthier,
Wilfried Wurth,
Ivan A. Vartanyants
Abstract:
Radiation damage is one of the most severe resolution limiting factors in x-ray imaging, especially relevant to biological samples. One way of circumventing this problem is to exploit correlation-based methods developed in quantum imaging. Among these, there is ghost imaging (GI) in which the image is formed by radiation that has never interacted with the sample. Here, we demonstrate GI at an XUV…
▽ More
Radiation damage is one of the most severe resolution limiting factors in x-ray imaging, especially relevant to biological samples. One way of circumventing this problem is to exploit correlation-based methods developed in quantum imaging. Among these, there is ghost imaging (GI) in which the image is formed by radiation that has never interacted with the sample. Here, we demonstrate GI at an XUV free-electron laser by utilizing correlation techniques. We discuss the experimental challenges, optimal setup, and crucial ingredients to maximize the achievable resolution.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Effects of energy spread on Brightness and Coherence of undulator sources
Authors:
Gianluca Geloni,
Svitozar Serkez,
Ruslan Khubbutdinov,
Vitali Kocharyan,
Evgeni Saldin
Abstract:
The (spectral) brightness for partially transverse coherent sources as Synchrotron Radiation (SR) and Free-Electron Laser (FEL) sources can be defined as the maximum of the Wigner distribution. Then, the brightness includes information on both coherence and wavefront characteristics of the radiation field. For undulator sources, it is customary to approximate the single-electron electric field at…
▽ More
The (spectral) brightness for partially transverse coherent sources as Synchrotron Radiation (SR) and Free-Electron Laser (FEL) sources can be defined as the maximum of the Wigner distribution. Then, the brightness includes information on both coherence and wavefront characteristics of the radiation field. For undulator sources, it is customary to approximate the single-electron electric field at resonance with a Gaussian beam, leading to great simplifications. Attempts to account for the modified spatial and angular profile of the undulator radiation in the presence of detuning due to energy spread currently build on the simplified brightness expression derived under the assumption of Gaussian beams. The influence of energy spread on undulator radiation properties is becoming important in view of diffraction-limited rings with ultralow emittance coming on-line. Here we discuss the effects of energy spread on the brightness of undulator radiation at resonance, as well as relevant relations with coherence properties.
△ Less
Submitted 15 August, 2018;
originally announced August 2018.