-
Materials for High Temperature Digital Electronics
Authors:
Dhiren K. Pradhan,
David C. Moore,
A. Matt Francis,
Jacob Kupernik,
W. Joshua Kennedy,
Nicholas R. Glavin,
Roy H. Olsson III,
Deep Jariwala
Abstract:
Silicon microelectronics, consisting of complementary metal oxide semiconductor (CMOS) technology, have changed nearly all aspects of human life from communication to transportation, entertainment, and healthcare. Despite the widespread and mainstream use, current silicon-based devices suffer significant reliability issues at temperatures exceeding 125 °C. The emergent technological frontiers of s…
▽ More
Silicon microelectronics, consisting of complementary metal oxide semiconductor (CMOS) technology, have changed nearly all aspects of human life from communication to transportation, entertainment, and healthcare. Despite the widespread and mainstream use, current silicon-based devices suffer significant reliability issues at temperatures exceeding 125 °C. The emergent technological frontiers of space exploration, geothermal energy harvesting, nuclear energy, unmanned avionic systems, and autonomous driving will rely on control systems, sensors, and communication devices which operate at temperatures as high as 500 °C and beyond. At these extreme temperatures, active (heat exchanger, phase change cooling) or passive (fins and thermal interface materials) cooling strategies add significant mass and complication which is often infeasible. Thus, new material solutions beyond conventional silicon CMOS devices are necessary for high temperature, resilient electronic systems. Accomplishing this will require a united effort to explore development, integration, and ultimately manufacturing of non-silicon-based logic and memory technologies, non-traditional metals for interconnects, and ceramic packaging technology.
△ Less
Submitted 4 April, 2024;
originally announced April 2024.
-
Scalable and Stable Ferroelectric Non-Volatile Memory at > 500 $^\circ$C
Authors:
Dhiren K. Pradhan,
David C. Moore,
Gwangwoo Kim,
Yunfei He,
Pariasadat Musavigharavi,
Kwan-Ho Kim,
Nishant Sharma,
Zirun Han,
Xingyu Du,
Venkata S. Puli,
Eric A. Stach,
W. Joshua Kennedy,
Nicholas R. Glavin,
Roy H. Olsson III,
Deep Jariwala
Abstract:
Non-volatile memory (NVM) devices that reliably operate at temperatures above 300 $^\circ$C are currently non-existent and remains a critically unmet challenge in the development of high-temperature (T) resilient electronics, necessary for many emerging, complex computing and sensing in harsh environments. Ferroelectric Al$_x$Sc$_{1-x}$N exhibits strong potential for utilization in NVM devices ope…
▽ More
Non-volatile memory (NVM) devices that reliably operate at temperatures above 300 $^\circ$C are currently non-existent and remains a critically unmet challenge in the development of high-temperature (T) resilient electronics, necessary for many emerging, complex computing and sensing in harsh environments. Ferroelectric Al$_x$Sc$_{1-x}$N exhibits strong potential for utilization in NVM devices operating at very high temperatures (> 500 $^\circ$C) given its stable and high remnant polarization (PR) above 100 $μ$C/cm$^2$ with demonstrated ferroelectric transition temperature (TC) > 1000 $^\circ$C. Here, we demonstrate an Al$_{0.68}$Sc$_{0.32}$N ferroelectric diode based NVM device that can reliably operate with clear ferroelectric switching up to 600 $^\circ$C with distinguishable On and Off states. The coercive field (EC) from the Pulsed I-V measurements is found to be -5.84 (EC-) and +5.98 (EC+) (+/- 0.1) MV/cm at room temperature (RT) and found to decrease with increasing temperature up to 600 $^\circ$C. The devices exhibit high remnant polarizations (> 100 $μ$C/cm$^2$) which are stable at high temperatures. At 500 $^\circ$C, our devices show 1 million read cycles and stable On-Off ratio above 1 for > 6 hours. Finally, the operating voltages of our AlScN ferrodiodes are < 15 V at 600 $^\circ$C which is well matched and compatible with Silicon Carbide (SiC) based high temperature logic technology, thereby making our demonstration a major step towards commercialization of NVM integrated high-T computers.
△ Less
Submitted 8 September, 2023;
originally announced September 2023.
-
Direct comparison of two spin squeezed optical clocks below the quantum projection noise limit
Authors:
John M Robinson,
Maya Miklos,
Yee Ming Tso,
Colin J. Kennedy,
Tobias Bothwell,
Dhruv Kedar,
James K. Thompson,
Jun Ye
Abstract:
Building scalable quantum systems that demonstrate genuine performance enhancement based on entanglement is a major scientific goal for fields including computing, networking, simulations, and metrology. The tremendous challenge arises from the fragility of entanglement in increasingly larger sized quantum systems. Optical atomic clocks utilizing a large number of atoms have pushed the frontier of…
▽ More
Building scalable quantum systems that demonstrate genuine performance enhancement based on entanglement is a major scientific goal for fields including computing, networking, simulations, and metrology. The tremendous challenge arises from the fragility of entanglement in increasingly larger sized quantum systems. Optical atomic clocks utilizing a large number of atoms have pushed the frontier of measurement science, building on precise engineering of quantum states and control of atomic interactions. However, today's state-of-the-art optical atomic clocks are limited by the quantum projection noise (QPN) defined by many uncorrelated atoms. Pioneering work on producing spin squeezed states of atoms has shown a path towards integrating entanglement into the best performing clocks. However, to directly demonstrate advantage of quantum entanglement in a working clock we must prevent backaction effects that degrade quantum coherence and introduce uncontrolled perturbations, as well as minimize the influence of technical noise arising from the interrogating clock laser. Here we present a new optical clock platform integrated with collective strong-coupling cavity QED for quantum non-demolition (QND) measurement. Optimizing the competition between spin measurement precision and loss of coherence, we measure a Wineland parameter of -1.8(7) dB for 1.9x10$^4$ atoms, thus verifying the presence of entanglement. Furthermore, a moving lattice allows the cavity to individually address two independent sub-ensembles, enabling us to spin squeeze two clock ensembles successively and compare their performance. This differential comparison between the two squeezed clocks directly verifies enhanced clock stability of 2.0(3) dB below QPN, and 0.6(3) dB above the standard quantum limit (SQL), at the measurement precision level of 10$^{-17}$, without subtracting any technical noise contributions.
△ Less
Submitted 16 November, 2022; v1 submitted 15 November, 2022;
originally announced November 2022.
-
How is model-related uncertainty quantified and reported in different disciplines?
Authors:
Emily G. Simmonds,
Kwaku Peprah Adjei,
Christoffer Wold Andersen,
Janne Cathrin Hetle Aspheim,
Claudia Battistin,
Nicola Bulso,
Hannah Christensen,
Benjamin Cretois,
Ryan Cubero,
Ivan A. Davidovich,
Lisa Dickel,
Benjamin Dunn,
Etienne Dunn-Sigouin,
Karin Dyrstad,
Sigurd Einum,
Donata Giglio,
Haakon Gjerlow,
Amelie Godefroidt,
Ricardo Gonzalez-Gil,
Soledad Gonzalo Cogno,
Fabian Grosse,
Paul Halloran,
Mari F. Jensen,
John James Kennedy,
Peter Egge Langsaether
, et al. (18 additional authors not shown)
Abstract:
How do we know how much we know? Quantifying uncertainty associated with our modelling work is the only way we can answer how much we know about any phenomenon. With quantitative science now highly influential in the public sphere and the results from models translating into action, we must support our conclusions with sufficient rigour to produce useful, reproducible results. Incomplete considera…
▽ More
How do we know how much we know? Quantifying uncertainty associated with our modelling work is the only way we can answer how much we know about any phenomenon. With quantitative science now highly influential in the public sphere and the results from models translating into action, we must support our conclusions with sufficient rigour to produce useful, reproducible results. Incomplete consideration of model-based uncertainties can lead to false conclusions with real world impacts. Despite these potentially damaging consequences, uncertainty consideration is incomplete both within and across scientific fields. We take a unique interdisciplinary approach and conduct a systematic audit of model-related uncertainty quantification from seven scientific fields, spanning the biological, physical, and social sciences. Our results show no single field is achieving complete consideration of model uncertainties, but together we can fill the gaps. We propose opportunities to improve the quantification of uncertainty through use of a source framework for uncertainty consideration, model type specific guidelines, improved presentation, and shared best practice. We also identify shared outstanding challenges (uncertainty in input data, balancing trade-offs, error propagation, and defining how much uncertainty is required). Finally, we make nine concrete recommendations for current practice (following good practice guidelines and an uncertainty checklist, presenting uncertainty numerically, and propagating model-related uncertainty into conclusions), future research priorities (uncertainty in input data, quantifying uncertainty in complex models, and the importance of missing uncertainty in different contexts), and general research standards across the sciences (transparency about study limitations and dedicated uncertainty sections of manuscripts).
△ Less
Submitted 1 July, 2022; v1 submitted 24 June, 2022;
originally announced June 2022.
-
Hamiltonian engineering of spin-orbit coupled fermions in a Wannier-Stark optical lattice clock
Authors:
Alexander Aeppli,
Anjun Chu,
Tobias Bothwell,
Colin J. Kennedy,
Dhruv Kedar,
Peiru He,
Ana Maria Rey,
Jun Ye
Abstract:
Engineering a Hamiltonian system with tunable interactions provides opportunities to optimize performance for quantum sensing and explore emerging phenomena of many-body systems. An optical lattice clock based on partially delocalized Wannier-Stark states in a gravity-tilted shallow lattice supports superior quantum coherence and adjustable interactions via spin-orbit coupling, thus presenting a p…
▽ More
Engineering a Hamiltonian system with tunable interactions provides opportunities to optimize performance for quantum sensing and explore emerging phenomena of many-body systems. An optical lattice clock based on partially delocalized Wannier-Stark states in a gravity-tilted shallow lattice supports superior quantum coherence and adjustable interactions via spin-orbit coupling, thus presenting a powerful spin model realization. The relative strength of the on-site and off-site interactions can be tuned to achieve a zero density shift at a `magic' lattice depth. This mechanism, together with a large number of atoms, enables the demonstration of the most stable atomic clock while minimizing a key systematic uncertainty related to atomic density. Interactions can also be maximized by driving off-site Wannier-Stark transitions, realizing a ferromagnetic to paramagnetic dynamical phase transition.
△ Less
Submitted 15 January, 2022;
originally announced January 2022.
-
Preparation of the spin-Mott state: a spinful Mott insulator of repulsively bound pairs
Authors:
Julius de Hond,
**ggang Xiang,
Woo Chang Chung,
Enid Cruz-Colón,
Wenlan Chen,
William Cody Burton,
Colin J. Kennedy,
Wolfgang Ketterle
Abstract:
We observe and study a special ground state of bosons with two spin states in an optical lattice: the spin-Mott insulator, a state that consists of repulsively bound pairs which is insulating for both spin and charge transport. Because of the pairing gap created by the interaction anisotropy, it can be prepared with low entropy and can serve as a starting point for adiabatic state preparation. We…
▽ More
We observe and study a special ground state of bosons with two spin states in an optical lattice: the spin-Mott insulator, a state that consists of repulsively bound pairs which is insulating for both spin and charge transport. Because of the pairing gap created by the interaction anisotropy, it can be prepared with low entropy and can serve as a starting point for adiabatic state preparation. We find that the stability of the spin-Mott state depends on the pairing energy, and observe two qualitatively different decay regimes, one of which exhibits protection by the gap.
△ Less
Submitted 5 October, 2021; v1 submitted 1 October, 2021;
originally announced October 2021.
-
Resolving the gravitational redshift within a millimeter atomic sample
Authors:
Tobias Bothwell,
Colin J. Kennedy,
Alexander Aeppli,
Dhruv Kedar,
John M. Robinson,
Eric Oelker,
Alexander Staron,
Jun Ye
Abstract:
Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and q…
▽ More
Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and quantum mechanics once they become sensitive to the finite wavefunction of quantum objects oscillating in curved spacetime. Towards this regime, we measure a linear frequency gradient consistent with the gravitational redshift within a single millimeter scale sample of ultracold strontium. Our result is enabled by improving the fractional frequency measurement uncertainty by more than a factor of 10, now reaching 7.6$\times 10^{-21}$. This heralds a new regime of clock operation necessitating intra-sample corrections for gravitational perturbations.
△ Less
Submitted 24 September, 2021;
originally announced September 2021.
-
Precision Metrology Meets Cosmology: Improved Constraints on Ultralight Dark Matter from Atom-Cavity Frequency Comparisons
Authors:
Colin J. Kennedy,
Eric Oelker,
John M. Robinson,
Tobias Bothwell,
Dhruv Kedar,
William R. Milner,
G. Edward Marti,
Andrei Derevianko,
Jun Ye
Abstract:
We conduct frequency comparisons between a state-of-the-art strontium optical lattice clock, a cryogenic crystalline silicon cavity, and a hydrogen maser to set new bounds on the coupling of ultralight dark matter to Standard Model particles and fields in the mass range of $10^{-16}$ $-$ $10^{-21}$ eV. The key advantage of this two-part ratio comparison is the differential sensitivities to time va…
▽ More
We conduct frequency comparisons between a state-of-the-art strontium optical lattice clock, a cryogenic crystalline silicon cavity, and a hydrogen maser to set new bounds on the coupling of ultralight dark matter to Standard Model particles and fields in the mass range of $10^{-16}$ $-$ $10^{-21}$ eV. The key advantage of this two-part ratio comparison is the differential sensitivities to time variation of both the fine-structure constant and the electron mass, achieving a substantially improved limit on the moduli of ultralight dark matter, particularly at higher masses than typical atomic spectroscopic results. Furthermore, we demonstrate an extension of the search range to even higher masses by use of dynamical decoupling techniques. These results highlight the importance of using the best performing atomic clocks for fundamental physics applications as all-optical timescales are increasingly integrated with, and will eventually supplant, existing microwave timescales.
△ Less
Submitted 20 August, 2020;
originally announced August 2020.
-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Demonstration of a time scale based on a stable optical carrier
Authors:
William R. Milner,
John M. Robinson,
Colin J. Kennedy,
Tobias Bothwell,
Dhruv Kedar,
Dan G. Matei,
Thomas Legero,
Uwe Sterr,
Fritz Riehle,
Holly Leopardi,
Tara M. Fortier,
Jeffrey A. Sherman,
Judah Levine,
Jian Yao,
Jun Ye,
Eric Oelker
Abstract:
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even wh…
▽ More
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even when they are steered to optical frequency standards. Our analysis indicates that this time scale is capable of reaching a stability below $1\times10^{-17}$ after a few months of averaging, making timekee** at the $10^{-18}$ level a realistic prospect.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
JILA SrI Optical Lattice Clock with Uncertainty of $2.0 \times 10^{-18}$
Authors:
Tobias Bothwell,
Dhruv Kedar,
Eric Oelker,
John M. Robinson,
Sarah L. Bromley,
Weston L. Tew,
Jun Ye,
Colin J. Kennedy
Abstract:
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reducti…
▽ More
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to $2.0 \times 10^{-18}$. A seven-fold improvement in clock stability, reaching $4.8 \times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds, allows the clock to average to its systematic uncertainty in under 10 minutes. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the Boulder Area Clock Optical Network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.
-
Optical clock intercomparison with $6\times 10^{-19}$ precision in one hour
Authors:
E. Oelker,
R. B. Hutson,
C. J. Kennedy,
L. Sonderhouse,
T. Bothwell,
A. Goban,
D. Kedar,
C. Sanner,
J. M. Robinson,
G. E. Marti,
D. G. Matei,
T. Legero,
M. Giunta,
R. Holzwarth,
F. Riehle,
U. Sterr,
J. Ye
Abstract:
Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the challenge of performing spectroscopy on their ultra-narrow linewidth clock transitions. Advances in laser stabilization have thus enabled rapid progress in clock preci…
▽ More
Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the challenge of performing spectroscopy on their ultra-narrow linewidth clock transitions. Advances in laser stabilization have thus enabled rapid progress in clock precision. A new class of ultrastable lasers based on cryogenic silicon reference cavities has recently demonstrated the longest optical coherence times to date. In this work we utilize such a local oscillator, along with a state-of-the-art frequency comb for coherence transfer, with two Sr optical lattice clocks to achieve an unprecedented level of clock stability. Through an anti-synchronous comparison, the fractional instability of both clocks is assessed to be $4.8\times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds. Synchronous interrogation reveals a quantum projection noise dominated instability of $3.5(2)\times10^{-17}/\sqrtτ$, resulting in a precision of $5.8(3)\times 10^{-19}$ after a single hour of averaging. The ability to measure sub-$10^{-18}$ level frequency shifts in such short timescales will impact a wide range of applications for clocks in quantum sensing and fundamental physics. For example, this precision allows one to resolve the gravitational red shift from a 1 cm elevation change in only 20 minutes.
△ Less
Submitted 7 February, 2019;
originally announced February 2019.
-
Coherence Times of Bose-Einstein Condensates beyond the Shot-Noise Limit via Superfluid Shielding
Authors:
William Cody Burton,
Colin J. Kennedy,
Woo Chang Chung,
Samarth Vadia,
Wenlan Chen,
Wolfgang Ketterle
Abstract:
We demonstrate a new way to extend the coherence time of separated Bose-Einstein condensates that involves immersion into a superfluid bath. When both the system and the bath have similar scattering lengths, immersion in a superfluid bath cancels out inhomogeneous potentials either imposed by external fields or inherent in density fluctuations due to atomic shot noise. This effect, which we call s…
▽ More
We demonstrate a new way to extend the coherence time of separated Bose-Einstein condensates that involves immersion into a superfluid bath. When both the system and the bath have similar scattering lengths, immersion in a superfluid bath cancels out inhomogeneous potentials either imposed by external fields or inherent in density fluctuations due to atomic shot noise. This effect, which we call superfluid shielding, allows for coherence lifetimes beyond the projection noise limit. We probe the coherence between separated condensates in different sites of an optical lattice by monitoring the contrast and decay of Bloch oscillations. Our technique demonstrates a new way that interactions can improve the performance of quantum devices.
△ Less
Submitted 30 November, 2016; v1 submitted 26 October, 2016;
originally announced October 2016.
-
Observation of Bose-Einstein Condensation in a Strong Synthetic Magnetic Field
Authors:
Colin J. Kennedy,
William Cody Burton,
Woo Chang Chung,
Wolfgang Ketterle
Abstract:
Extensions of Berry's phase and the quantum Hall effect have led to the discovery of new states of matter with topological properties. Traditionally, this has been achieved using gauge fields created by magnetic fields or spin orbit interactions which couple only to charged particles. For neutral ultracold atoms, synthetic magnetic fields have been created which are strong enough to realize the Ha…
▽ More
Extensions of Berry's phase and the quantum Hall effect have led to the discovery of new states of matter with topological properties. Traditionally, this has been achieved using gauge fields created by magnetic fields or spin orbit interactions which couple only to charged particles. For neutral ultracold atoms, synthetic magnetic fields have been created which are strong enough to realize the Harper-Hofstadter model. Despite many proposals and major experimental efforts, so far it has not been possible to prepare the ground state of this system. Here we report the observation of Bose-Einstein condensation for the Harper-Hofstadter Hamiltonian with one-half flux quantum per lattice unit cell. The diffraction pattern of the superfluid state directly shows the momentum distribution on the wavefuction, which is gauge-dependent. It reveals both the reduced symmetry of the vector potential and the twofold degeneracy of the ground state. We explore an adiabatic many-body state preparation protocol via the Mott insulating phase and observe the superfluid ground state in a three-dimensional lattice with strong interactions.
△ Less
Submitted 27 March, 2015;
originally announced March 2015.
-
Optical hyperpolarization and NMR detection of $^{129}$Xe on a microfluidic chip
Authors:
Ricardo Jimenez-Martinez,
Daniel J. Kennedy,
Michael Rosenbluh,
Elizabeth A. Donley,
Svenja Knappe,
Scott J. Seltzer,
Hattie L. Ring,
Vikram S. Bajaj,
John Kitching
Abstract:
Optically hyperpolarized $^{129}$Xe gas has become a powerful contrast agent in nuclear magnetic resonance (NMR) spectroscopy and imaging, with applications ranging from studies of the human lung to the targeted detection of biomolecules. Equally attractive is its potential use to enhance the sensitivity of microfluidic NMR experiments, in which small sample volumes yield poor sensitivity. Unfortu…
▽ More
Optically hyperpolarized $^{129}$Xe gas has become a powerful contrast agent in nuclear magnetic resonance (NMR) spectroscopy and imaging, with applications ranging from studies of the human lung to the targeted detection of biomolecules. Equally attractive is its potential use to enhance the sensitivity of microfluidic NMR experiments, in which small sample volumes yield poor sensitivity. Unfortunately, most $^{129}$Xe polarization systems are large and non-portable. Here we present a microfabricated chip that optically polarizes $^{129}$Xe gas. We have achieved $^{129}$Xe polarizations greater than 0.5$\%$ at flow rates of several microliters per second, compatible with typical microfluidic applications. We employ in situ optical magnetometry to sensitively detect and characterize the $^{129}$Xe polarization at magnetic fields of 1 $μ$T. We construct the device using standard microfabrication techniques, which will facilitate its integration with existing microfluidic platforms. This device may enable the implementation of highly sensitive $^{129}$Xe NMR in compact, low-cost, portable devices.
△ Less
Submitted 30 December, 2013;
originally announced January 2014.
-
Realizing the Harper Hamiltonian with Laser-Assisted Tunneling in Optical Lattices
Authors:
Hirokazu Miyake,
Georgios A. Siviloglou,
Colin J. Kennedy,
William Cody Burton,
Wolfgang Ketterle
Abstract:
We experimentally implement the Harper Hamiltonian for neutral particles in optical lattices using laser-assisted tunneling and a potential energy gradient provided by gravity or magnetic field gradients. This Hamiltonian describes the motion of charged particles in strong magnetic fields. Laser-assisted tunneling processes are characterized by studying the expansion of the atoms in the lattice. T…
▽ More
We experimentally implement the Harper Hamiltonian for neutral particles in optical lattices using laser-assisted tunneling and a potential energy gradient provided by gravity or magnetic field gradients. This Hamiltonian describes the motion of charged particles in strong magnetic fields. Laser-assisted tunneling processes are characterized by studying the expansion of the atoms in the lattice. The band structure of this Hamiltonian should display Hofstadter's butterfly. For fermions, this scheme should realize the quantum Hall effect and chiral edge states.
△ Less
Submitted 12 August, 2013; v1 submitted 6 August, 2013;
originally announced August 2013.
-
Correction of Optical Aberrations in Elliptic Neutron Guides
Authors:
Phillip M. Bentley,
Shane J. Kennedy,
Ken H. Andersen,
Damian Martin Rodriguez,
David F. R. Mildner
Abstract:
Modern, nonlinear ballistic neutron guides are an attractive concept in neutron beam delivery and instrumentation, because they offer increased performance over straight or linearly tapered guides. However, like other ballistic geometries they have the potential to create significantly non-trivial instrumental resolution functions. We address the source of the most prominent optical aberration, na…
▽ More
Modern, nonlinear ballistic neutron guides are an attractive concept in neutron beam delivery and instrumentation, because they offer increased performance over straight or linearly tapered guides. However, like other ballistic geometries they have the potential to create significantly non-trivial instrumental resolution functions. We address the source of the most prominent optical aberration, namely coma, and we show that for extended sources the off-axis rays have a different focal length from on-axis rays, leading to multiple reflections in the guide system. We illustrate how the interplay between coma, sources of finite size, and mirrors with non-perfect reflectivity can therefore conspire to produce uneven distributions in the neutron beam divergence, the source of complicated resolution functions. To solve these problems, we propose a hybrid elliptic-parabolic guide geometry. Using this new kind of neutron guide shape, it is possible to condition the neutron beam and remove almost all of the aberrations, whilst providing the same performance in beam current as a standard elliptic neutron guide. We highlight the positive implications for a number of neutron scattering instrument types that this new shape can bring.
△ Less
Submitted 20 January, 2012;
originally announced January 2012.
-
Room Temperature Operation of a Radiofrequency Diamond Magnetometer near the Shot Noise Limit
Authors:
Chang S. Shin,
Claudia E. Avalos,
Mark C. Butler,
David R. Trease,
Scott J. Seltzer,
J. Peter Mustonen,
Daniel J. Kennedy,
Victor M. Acosta,
Dmitry Budker,
Alexander Pines,
Vikram S. Bajaj
Abstract:
We operate a nitrogen vacancy (NV-) diamond magnetometer at ambient temperatures and study the dependence of its bandwidth on experimental parameters including optical and microwave excitation powers. We introduce an analytical theory that yields an explicit formula for the response of an ensemble of NV- spins to an oscillating magnetic field, such as in NMR applications. We measure a detection ba…
▽ More
We operate a nitrogen vacancy (NV-) diamond magnetometer at ambient temperatures and study the dependence of its bandwidth on experimental parameters including optical and microwave excitation powers. We introduce an analytical theory that yields an explicit formula for the response of an ensemble of NV- spins to an oscillating magnetic field, such as in NMR applications. We measure a detection bandwidth of 1.6 MHz and a sensitivity of 4.6 nT/Hz^(1/2), unprecedented in a detector with this active volume and close to the photon shot noise limit of our experiment.
△ Less
Submitted 15 January, 2012;
originally announced January 2012.
-
Frequency Multiplexed SQUID Readout of Large Bolometer Arrays for Cosmic Microwave Background Measurements
Authors:
M. A. Dobbs,
M. Lueker,
K. A. Aird,
A. N. Bender,
B. A. Benson,
L. E. Bleem,
J. E. Carlstrom,
C. L. Chang,
H. -M. Cho,
J. Clarke,
T. M. Crawford,
A. T. Crites,
D. I. Flanigan,
T. de Haan,
E. M. George,
N. W. Halverson,
W. L. Holzapfel,
J. D. Hrubes,
B. R. Johnson,
J. Joseph,
R. Keisler,
J. Kennedy,
Z. Kermish,
T. M. Lanting,
A. T. Lee
, et al. (22 additional authors not shown)
Abstract:
A technological milestone for experiments employing Transition Edge Sensor (TES) bolometers operating at sub-kelvin temperature is the deployment of detector arrays with 100s--1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout syste…
▽ More
A technological milestone for experiments employing Transition Edge Sensor (TES) bolometers operating at sub-kelvin temperature is the deployment of detector arrays with 100s--1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ~MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with Superconducting Quantum Interference Devices (SQUIDs) operating at 4 K. Room-temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.
△ Less
Submitted 17 July, 2012; v1 submitted 18 December, 2011;
originally announced December 2011.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
An imaging time-of-propagation system for charged particle identification at a super B factory
Authors:
K. Nishimura,
T. Browder,
H. Hoedlmoser,
B. Jacobson,
J. Kennedy,
M. Rosen,
L. Ruckman,
G. Varner,
A. Wong,
W. Yen
Abstract:
Super B factories that will further probe the flavor sector of the Standard Model and physics beyond will demand excellent charged particle identification (PID), particularly K/pi separation, for momenta up to 4 GeV/c, as well as the ability to operate under beam backgrounds significantly higher than current B factory experiments. We describe an Imaging Time-of-Propagation (iTOP) detector which…
▽ More
Super B factories that will further probe the flavor sector of the Standard Model and physics beyond will demand excellent charged particle identification (PID), particularly K/pi separation, for momenta up to 4 GeV/c, as well as the ability to operate under beam backgrounds significantly higher than current B factory experiments. We describe an Imaging Time-of-Propagation (iTOP) detector which shows significant potential to meet these requirements. Photons emitted from charged particle interactions in a Cerenkov radiator bar are internally reflected to the end of the bar, where they are collected on a compact image plane using photodetectors with fine spatial segmentation in two dimensions. Precision measurements of photon arrival time are used to enhance the two dimensional imaging, allowing the system to provide excellent PID capabilities within a reduced detector envelope. Results of the ongoing optimization of the geometric and physical properties of such a detector are presented, as well as simulated PID performance. Validation of simulations is being performed using a prototype in a cosmic ray test stand at the University of Hawaii.
△ Less
Submitted 3 September, 2009;
originally announced September 2009.
-
BES3 time of flight monitoring system
Authors:
F. A. Harris,
J. W. Kennedy,
Q. Liu,
L. Nguyen,
S. L. Olsen,
M. Rosen,
C. P. Shen,
G. S. Varner,
Y. K. Heng,
Z. J. Sun,
K. J. Zhu,
Q. An,
C. Q. Feng,
S. B. Liu
Abstract:
A Time of Flight monitoring system has been developed for BES3.
The light source is a 442-443 nm laser diode, which is stable and provides a pulse width as narrow as 50 ps and a peak power as large as 2.6 W. Two optical-fiber bundles with a total of 512 optical fibers, including spares, are used to distribute the light pulses to the Time of Flight counters. The design, operation, and performan…
▽ More
A Time of Flight monitoring system has been developed for BES3.
The light source is a 442-443 nm laser diode, which is stable and provides a pulse width as narrow as 50 ps and a peak power as large as 2.6 W. Two optical-fiber bundles with a total of 512 optical fibers, including spares, are used to distribute the light pulses to the Time of Flight counters. The design, operation, and performance of the system are described.
△ Less
Submitted 26 April, 2008;
originally announced April 2008.