-
Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter
Authors:
M. Aehle,
J. Alme,
C. Arata,
I. Arsene,
I. Bearden,
T. Bodova,
V. Borshchov,
O. Bourrion,
M. Bregant,
A. van den Brink,
V. Buchakchiev,
A. Buhl,
T. Chujo,
L. Dufke,
V. Eikeland,
M. Fasel,
N. Gauger,
A. Gautam,
A. Ghimouz,
Y. Goto,
R. Guernane,
T. Hachiya,
H. Hassan,
L. He,
H. Helstrup
, et al. (50 additional authors not shown)
Abstract:
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS a…
▽ More
We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
Relations Between Generalized JST Algorithm and Kalman Filtering Algorithm for Time Scale Generation
Authors:
Yuyue Yan,
Takahiro Kawaguchi,
Yuichiro Yano,
Yuko Hanado,
Takayuki Ishizaki
Abstract:
In this paper, we present a generalized Japan Standard Time algorithm (JST-algo) for higher-order atomic clock ensembles and mathematically clarify the relations of the (generalized) JST-algo and the conventional Kalman filtering algorithm (CKF-algo) in the averaged atomic time and the clock residuals for time scale generation. In particular, we reveal the fact that the averaged atomic time of the…
▽ More
In this paper, we present a generalized Japan Standard Time algorithm (JST-algo) for higher-order atomic clock ensembles and mathematically clarify the relations of the (generalized) JST-algo and the conventional Kalman filtering algorithm (CKF-algo) in the averaged atomic time and the clock residuals for time scale generation. In particular, we reveal the fact that the averaged atomic time of the generalized JST-algo does not depend on the observation noise even though the measurement signal is not filtered in the algorithm. Furthermore, the prediction error of CKF- algo is rigorously shown by using the prediction error regarding an observable state space. It is mathematically shown that when the covariance matrices of system noises are identical for all atomic clocks, considering equal averaging weights for the clocks is a necessary and sufficient condition to ensure equivalence between the generalized JST-algo and CKF-algo in averaged atomic time. In such homogeneous systems, a necessary and sufficient condition for observation noises is presented to determine which algorithm can generate the clock residuals with smaller variances. A couple of numerical examples comparing the generalized JST-algo and CKF-algo are provided to illustrate the efficacy of the results.
△ Less
Submitted 24 August, 2023;
originally announced August 2023.
-
A novel technique for the measurement of the avalanche fluctuations of a GEM stack using a gating foil
Authors:
M. Kobayashi,
K. Yumino,
T. Ogawa,
A. Shoji,
Y. Aoki,
K. Ikematsu,
P. Gros,
T. Kawaguchi,
D. Arai,
M. Iwamura,
K. Katsuki,
A. Koto,
M. Yoshikai,
K. Fujii,
T. Fusayasu,
Y. Kato,
S. Kawada,
T. Matsuda,
T. Mizuno,
J. Nakajima,
S. Narita,
K. Negishi,
H. Qi,
R. D. Settles,
A. Sugiyama
, et al. (4 additional authors not shown)
Abstract:
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment (ILD-TPC). In addition to the gating function, the gating foil is capable of controlling the average fraction of drift electrons detected after gas amplificatio…
▽ More
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment (ILD-TPC). In addition to the gating function, the gating foil is capable of controlling the average fraction of drift electrons detected after gas amplification. The signal charge width and shape (skewness) for electron-ion pairs created by a pulsed UV laser as a function of the transmission rate of the gating foil can be used to determine the relative variance of gas gain for single electrons. We present the measurement principle and the result obtained using a stack of gas electron multipliers (GEMs) operated in a gas mixture of Ar-CF$_4$(3%)-isobutane(2%) at atmospheric pressure. Also discussed is the influence of the avalanche fluctuations on the spatial resolution of the ILD-TPC.
△ Less
Submitted 2 July, 2022;
originally announced July 2022.
-
Studying Internal Compositions of Binary Alloy Pd-Rh Nanoparticles Using Bragg Coherent Diffraction Imaging
Authors:
Tomoya Kawaguchi,
Wonsuk Cha,
Vitalii Latyshev,
Serhii Vorobiov,
Vladimir Komanicky,
Hoydoo You
Abstract:
Bragg coherent diffraction imaging (BCDI), the well-established technique for imaging internal strain of nanoparticles, was used to image the internal compositional distribution of binary alloys in thermal equilibrium. The images experimentally obtained for Pd-Rh alloy nanoparticles are presented and discussed. The direct correspondence between the lattice strain and the compositional deviation is…
▽ More
Bragg coherent diffraction imaging (BCDI), the well-established technique for imaging internal strain of nanoparticles, was used to image the internal compositional distribution of binary alloys in thermal equilibrium. The images experimentally obtained for Pd-Rh alloy nanoparticles are presented and discussed. The direct correspondence between the lattice strain and the compositional deviation is discussed in the derivation of the BCDI displacement field aided by illustrations.
△ Less
Submitted 8 July, 2019; v1 submitted 15 June, 2019;
originally announced June 2019.
-
Measurement of the electron transmission rate of the gating foil for the TPC of the ILC experiment
Authors:
M. Kobayashi,
T. Ogawa,
A. Shoji,
Y. Aoki,
K. Ikematsu,
P. Gros,
T. Kawaguchi,
D. Arai,
M. Iwamura,
K. Katsuki,
A. Koto,
M. Yoshikai,
K. Fujii,
T. Fusayasu,
Y. Kato,
S. Kawada,
T. Matsuda,
S. Narita,
K. Negishi,
H. Qi,
R. D. Settles,
A. Sugiyama,
T. Takahashi,
J. Tian,
T. Watanabe
, et al. (1 additional authors not shown)
Abstract:
We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture ratio and functions as an ion gate without gas amplification. The transmission rate for electrons was measured in a counting mode for a wide range of the voltag…
▽ More
We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture ratio and functions as an ion gate without gas amplification. The transmission rate for electrons was measured in a counting mode for a wide range of the voltages applied across the foil using an $^{55}$Fe source and a laser in the absence of a magnetic field. The blocking power of the foil against positive ions was estimated from the electron transmissions.
△ Less
Submitted 1 May, 2019; v1 submitted 5 March, 2019;
originally announced March 2019.
-
A novel technique for the measurement of the avalanche fluctuation of gaseous detectors
Authors:
Makoto Kobayashi,
Tomohisa Ogawa,
Tomohiko Kawaguchi,
Keisuke Fujii,
Takahiro Fusayasu,
Katsumasa Ikematsu,
Yukihiro Kato,
Shin-ichi Kawada,
Takeshi Matsuda,
Ronald Dean Settles,
Akira Sugiyama,
Tohru Takahashi,
Jun** Tian,
Takashi Watanabe,
Ryo Yonamine
Abstract:
We have developed a novel technique for the measurement of the avalanche fluctuation of gaseous detectors using a UV laser. The technique is simple and requires a short data-taking time of about ten minutes. Furthermore, it is applicable for relatively low gas gains. Our experimental setup as well as the measurement principle, and the results obtained with a stack of Gas Electron Multipliers (GEMs…
▽ More
We have developed a novel technique for the measurement of the avalanche fluctuation of gaseous detectors using a UV laser. The technique is simple and requires a short data-taking time of about ten minutes. Furthermore, it is applicable for relatively low gas gains. Our experimental setup as well as the measurement principle, and the results obtained with a stack of Gas Electron Multipliers (GEMs) operated in several gas mixtures are presented.
△ Less
Submitted 21 March, 2023; v1 submitted 3 July, 2016;
originally announced July 2016.