-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
A Search for Charged Lepton Flavor Violation in the Mu2e Experiment
Authors:
Manolis Kargiantoulakis
Abstract:
The Mu2e experiment will search for the neutrino-less conversion of a muon into an electron in the field of an aluminum nucleus. An observation would be the first signal of charged lepton flavor violation and de facto evidence for new physics beyond the Standard Model. The clean signature of the conversion process offers an opportunity for a powerful search: Mu2e will probe four orders of magnitud…
▽ More
The Mu2e experiment will search for the neutrino-less conversion of a muon into an electron in the field of an aluminum nucleus. An observation would be the first signal of charged lepton flavor violation and de facto evidence for new physics beyond the Standard Model. The clean signature of the conversion process offers an opportunity for a powerful search: Mu2e will probe four orders of magnitude beyond current limits, with real discovery potential over a wide range of well motivated new physics models. This goal requires an integrated system of solenoids that will create the most intense muon beam in the world, and suppression of all possible background sources. The Mu2e components are currently being constructed, with the experiment planned to begin operations in the Fermilab Muon Campus within the next few years.
△ Less
Submitted 1 April, 2020; v1 submitted 27 March, 2020;
originally announced March 2020.
-
Reduction of coherent betatron oscillations in a muon g-2 storage ring experiment using RF fields
Authors:
On Kim,
SeungPyo Chang,
Jihoon Choi,
Selcuk Haciomeroglu,
Young-Im Kim,
Yuri F. Orlov,
Yannis K. Semertzidis,
Meghna Bhattacharya,
Jason D. Crnkovic,
Sudeshna Ganguly,
Manolis Kargiantoulakis,
Soohyung Lee,
William M. Morse,
Hogan Nguyen,
B. Lee Roberts,
Vladimir Tishchenko,
Nam H. Tran,
Esra Barlas Yucel
Abstract:
This work demonstrates that two systematic errors, coherent betatron oscillations (CBO) and muon losses can be reduced through application of radio frequency (RF) electric fields, which ultimately increases the sensitivity of the muon $g-2$ experiments. As the ensemble of polarized muons goes around a weak focusing storage ring, their spin precesses, and when they decay through the weak interactio…
▽ More
This work demonstrates that two systematic errors, coherent betatron oscillations (CBO) and muon losses can be reduced through application of radio frequency (RF) electric fields, which ultimately increases the sensitivity of the muon $g-2$ experiments. As the ensemble of polarized muons goes around a weak focusing storage ring, their spin precesses, and when they decay through the weak interaction, $μ^+ \rightarrow e^+ ν_e \bar{ν_μ}$, the decay positrons are detected by electromagnetic calorimeters. In addition to the expected exponential decay in the positron time spectrum, the weak decay asymmetry causes a modulation in the number of positrons in a selected energy range at the difference frequency between the spin and cyclotron frequencies, $ω_\text{a}$. This frequency is directly proportional to the magnetic anomaly $a_μ=(g-2)/2$, where $g$ is the g-factor of the muon, which is slightly greater than 2. The detector acceptance depends on the radial position of the muon decay, so the CBO of the muon bunch following injection into the storage ring modulate the measured muon signal with the frequency $ω_\text{CBO}$. In addition, the muon populations at the edge of the beam hit the walls of the vacuum chamber before decaying, which also affects the signal. Thus, reduction of CBO and unwanted muon loss increases the $a_μ$ measurement sensitivity. Numerical and experimental studies with RF electric fields yield more than a magnitude reduction of the CBO, with muon losses comparable to the conventional method.
△ Less
Submitted 26 February, 2020; v1 submitted 8 February, 2019;
originally announced February 2019.
-
Expression of Interest for Evolution of the Mu2e Experiment
Authors:
F. Abusalma,
D. Ambrose,
A. Artikov,
R. Bernstein,
G. C. Blazey,
C. Bloise,
S. Boi,
T. Bolton,
J. Bono,
R. Bonventre,
D. Bowring,
D. Brown,
D. Brown,
K. Byrum,
M. Campbell,
J. -F. Caron,
F. Cervelli,
D. Chokheli,
K. Ciampa,
R. Ciolini,
R. Coleman,
D. Cronin-Hennessy,
R. Culbertson,
M. A. Cummings,
A. Daniel
, et al. (103 additional authors not shown)
Abstract:
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the fores…
▽ More
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the foreseeable future. Mu2e-II will use as much of the Mu2e infrastructure as possible, providing, where required, improvements to the Mu2e apparatus to accommodate the increased beam intensity and cope with the accompanying increase in backgrounds.
△ Less
Submitted 7 February, 2018;
originally announced February 2018.
-
The Q_weak Experimental Apparatus
Authors:
Qweak Collaboration,
T. Allison,
M. Anderson,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
T. D. Averett,
R. Averill,
J. Balewski,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Bessuille,
J. Birchall,
E. Bonnell,
J. Bowman,
P. Brindza,
D. B. Brown,
R. D. Carlini,
G. D. Cates,
B. Cavness,
G. Clark,
J. C. Cornejo,
S. Covrig Dusa
, et al. (104 additional authors not shown)
Abstract:
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry…
▽ More
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.
△ Less
Submitted 6 January, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.