The Heavy Photon Search Test Detector
Authors:
Marco Battaglieri,
Sergey Boyarinov,
Stephen Bueltmann,
Volker Burkert,
Andrea Celentano,
Gabriel Charles,
William Cooper,
Chris Cuevas,
Natalia Dashyan,
Raffaella DeVita,
Camille Desnault,
Alexandre Deur,
Hovanes Egiyan,
Latifa Elouadrhiri,
Rouven Essig,
Vitaliy Fadeyev,
Clive Field,
Arne Freyberger,
Yuri Gershtein,
Nerses Gevorgyan,
Francois-Xavier Girod,
Norman Graf,
Mathew Graham,
Keith Griffioen,
Alexander Grillo
, et al. (39 additional authors not shown)
Abstract:
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm th…
▽ More
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm that the trigger rates and occupancies are as expected. This paper describes the HPS Test Run apparatus and readout electronics and its performance. In this setting, a heavy photon can be identified as a narrow peak in the e$^+$e$^-$ invariant mass spectrum, above the trident background or as a narrow invariant mass peak with a decay vertex displaced from the production target, so charged particle tracking and vertexing are needed for its detection. In the HPS Test Run, charged particles are measured with a compact forward silicon microstrip tracker inside a dipole magnet. Electromagnetic showers are detected in a PbW0$_{4}$ crystal calorimeter situated behind the magnet, and are used to trigger the experiment and identify electrons and positrons. Both detectors are placed close to the beam line and split top-bottom. This arrangement provides sensitivity to low-mass heavy photons, allows clear passage of the unscattered beam, and avoids the spray of degraded electrons coming from the target. The discrimination between prompt and displaced e$^+$e$^-$ pairs requires the first layer of silicon sensors be placed only 10~cm downstream of the target. The expected signal is small, and the trident background huge, so the experiment requires very large statistics. Accordingly, the HPS Test Run utilizes high-rate readout and data acquisition electronics and a fast trigger to exploit the essentially 100% duty cycle of the CEBAF accelerator at JLab.
△ Less
Submitted 4 June, 2015; v1 submitted 23 June, 2014;
originally announced June 2014.