-
Sequentially Deposited versus Conventional Nonfullerene Organic Solar Cells: Interfacial Trap States, Vertical Stratification, and Exciton Dissociation
Authors:
Jiangbin Zhang,
Moritz H. Futscher,
Vincent Lami,
Felix U. Kosasih,
Changsoon Cho,
Qinying Gu,
Aditya Sadhanala,
Andrew J. Pearson,
Bin Kan,
Giorgio Divitini,
Xiangjian Wan,
Daniel Credgington,
Neil C. Greenham,
Yongsheng Chen,
Caterina Ducati,
Bruno Ehrler,
Yana Vaynzof,
Richard H. Friend,
Artem A. Bakulin
Abstract:
Bulk-heterojunction (BHJ) non-fullerene organic solar cells prepared from sequentially deposited donor and acceptor layers (sq-BHJ) have recently been promising to be highly efficient, environmentally friendly, and compatible with large area and roll-to-toll fabrication. However, the related photophysics at donor-acceptor interface and the vertical heterogeneity of donor-acceptor distribution, cri…
▽ More
Bulk-heterojunction (BHJ) non-fullerene organic solar cells prepared from sequentially deposited donor and acceptor layers (sq-BHJ) have recently been promising to be highly efficient, environmentally friendly, and compatible with large area and roll-to-toll fabrication. However, the related photophysics at donor-acceptor interface and the vertical heterogeneity of donor-acceptor distribution, critical for exciton dissociation and device performance, are largely unexplored. Herein, steady-state and time-resolved optical and electrical techniques are employed to characterize the interfacial trap states. Correlation with the luminescent efficiency of interfacial states and its non-radiative recombination, interfacial trap states are characterized to be about 50% more populated in the sq-BHJ than as-cast BHJ (c-BHJ), which probably limits the device voltage output. Cross-sectional energy-dispersive X-ray spectroscopy and ultraviolet photoemission spectroscopy depth profiling directly vizualize the donor-acceptor vertical stratification with a precision of 1-2 nm. From the proposed "needle" model, the high exciton dissociation efficiency is rationalized. Our study highlights the promise of sequential deposition to fabricate efficient solar cells, and points towards improving the voltage output and overall device performance via eliminating interfacial trap states.
△ Less
Submitted 30 July, 2020;
originally announced July 2020.
-
Universal coupling between the photonics and phononics in a 3D graphene sponge
Authors:
M. Shalaby,
C. Vicario,
F. Giorgianni,
M. A. Gaspar,
P. Craievich,
Y. Chen,
B. Kan,
S. Lupi,
C. P. Hauri
Abstract:
Photon-phonon coupling holds strong potential for sound and temperature control with light, opening new horizons in detector technology, remote sound generation and signal broadcasting. Here, we report on a novel stereoscopic ultralight converter based on a three dimensional graphene structure 3G-sponge, which exhibits very high absorption, near-to-air density, low inertia, and negligible effectiv…
▽ More
Photon-phonon coupling holds strong potential for sound and temperature control with light, opening new horizons in detector technology, remote sound generation and signal broadcasting. Here, we report on a novel stereoscopic ultralight converter based on a three dimensional graphene structure 3G-sponge, which exhibits very high absorption, near-to-air density, low inertia, and negligible effective heat capacity. We studied the heat and sound generation under the excitation of electromagnetic waves. 3G-sponge shows exceptional photon to heat and sound transduction efficiency over an enormous frequency range from MHz to PHz. As an application, we present an audio receiver based on a 3G-sponge amplitude demodulation. Our results will lead to a wide range of applications from light-controlled sound sources to broadband high-frequency graphene electronics.
△ Less
Submitted 22 June, 2019;
originally announced June 2019.
-
JUNO Conceptual Design Report
Authors:
T. Adam,
F. An,
G. An,
Q. An,
N. Anfimov,
V. Antonelli,
G. Baccolo,
M. Baldoncini,
E. Baussan,
M. Bellato,
L. Bezrukov,
D. Bick,
S. Blyth,
S. Boarin,
A. Brigatti,
T. Brugière,
R. Brugnera,
M. Buizza Avanzini,
J. Busto,
A. Cabrera,
H. Cai,
X. Cai,
A. Cammi,
D. Cao,
G. Cao
, et al. (372 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the dete…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$σ$, and determine neutrino oscillation parameters $\sin^2θ_{12}$, $Δm^2_{21}$, and $|Δm^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.
△ Less
Submitted 28 September, 2015; v1 submitted 28 August, 2015;
originally announced August 2015.