-
Integration of High-Tc Superconductors with High Q Factor Oxide Mechanical Resonators
Authors:
Nicola Manca,
Alexei Kalaboukhov,
Alejandro E. Plaza,
Leonélio Cichetto Jr,
Emilio Bellingeri,
Francesco Bisio,
Floriana Lombardi,
Daniele Marré,
Luca Pellegrino
Abstract:
Micro-mechanical resonators are building blocks of a variety of applications in basic science and applied electronics. This device technology is mainly based on well-established and reproducible silicon-based fabrication processes with outstanding performances in term of mechanical Q factor and sensitivity to external perturbations. Broadening the functionalities of MEMS by the integration of func…
▽ More
Micro-mechanical resonators are building blocks of a variety of applications in basic science and applied electronics. This device technology is mainly based on well-established and reproducible silicon-based fabrication processes with outstanding performances in term of mechanical Q factor and sensitivity to external perturbations. Broadening the functionalities of MEMS by the integration of functional materials is a key step for both applied and fundamental science. However, combining functional materials and silicon-based compounds is challenging. An alternative approach is fabricating MEMS based on complex heterostructures made of materials inherently showing a variety of physical properties such as transition metal oxides. Here, we report on the integration of a high-Tc superconductor YBa2Cu3O7 (YBCO) with high Q factor micro-bridge resonator made of a single-crystal LaAlO3 (LAO) thin film. LAO resonators are tensile strained, with a stress of 345 MPa, show Q factor in the range of tens of thousands, and have low roughness. The topmost YBCO layer deposited by Pulse Laser Deposition shows a superconducting transition starting at 90 K with zero resistance below 78 K. This result opens new possibilities towards the development of advanced transducers, such as bolometers or magnetic field detectors, as well as basic science experiments in solid state physics, material science, and quantum opto-mechanics.
△ Less
Submitted 23 January, 2024;
originally announced January 2024.
-
Strong in-plane magnetic anisotropy (Co0.15Fe0.85)5GeTe2/graphene van der Waals heterostructure spin-valve at room temperature
Authors:
Roselle Ngaloy,
Bing Zhao,
Soheil Ershadrad,
Rahul Gupta,
Masoumeh Davoudiniya,
Lakhan Bainsla,
Lars Sjöström,
Anamul M. Hoque,
Alexei Kalaboukhov,
Peter Svedlindh,
Biplab Sanyal,
Saroj P. Dash
Abstract:
Van der Waals (vdW) magnets are promising owing to their tunable magnetic properties with do** or alloy composition, where the strength of magnetic interactions, their symmetry, and magnetic anisotropy can be tuned according to the desired application. However, most of the vdW magnet based spintronic devices are so far limited to cryogenic temperatures with magnetic anisotropies favouring out-of…
▽ More
Van der Waals (vdW) magnets are promising owing to their tunable magnetic properties with do** or alloy composition, where the strength of magnetic interactions, their symmetry, and magnetic anisotropy can be tuned according to the desired application. However, most of the vdW magnet based spintronic devices are so far limited to cryogenic temperatures with magnetic anisotropies favouring out-of-plane or canted orientation of the magnetization. Here, we report room-temperature lateral spin-valve devices with strong in-plane magnetic anisotropy of the vdW ferromagnet (Co0.15Fe0.85)5GeTe2 (CFGT) in heterostructures with graphene. Magnetization measurements reveal above room-temperature ferromagnetism in CFGT with a strong in-plane magnetic anisotropy. Density functional theory calculations show that the magnitude of the anisotropy depends on the Co concentration and is caused by the substitution of Co in the outermost Fe layer. Heterostructures consisting of CFGT nanolayers and graphene were used to experimentally realize basic building blocks for spin valve devices such as efficient spin injection and detection. The spin transport and Hanle spin precession measurements prove a strong in-plane and negative spin polarization at the interface with graphene, which is supported by the calculated spin-polarized density of states of CFGT. The in-plane magnetization of CFGT at room temperature proves its usefulness in graphene lateral spin-valve devices, thus opening further opportunities for spintronic technologies.
△ Less
Submitted 30 October, 2023;
originally announced October 2023.
-
The role of kinetic inductance on the performance of YBCO SQUID magnetometers
Authors:
S. Ruffieux,
A. Kalaboukhov,
M. Xie,
M. Chukharkin,
C. Pfeiffer,
S. Sepehri,
J. F. Schneiderman,
D. Winkler
Abstract:
Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) because lower SQUID inductance $L$ leads to lower flux noise, but also weaker coupling to the pickup loop. In order to optimize the SQUID design, we combine inductance simulations and measureme…
▽ More
Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) because lower SQUID inductance $L$ leads to lower flux noise, but also weaker coupling to the pickup loop. In order to optimize the SQUID design, we combine inductance simulations and measurements to extract the different inductance contributions, and measure the dependence of the transfer function $V_Φ$ and flux noise $S_Φ^{1/2}$ on $L$. A comparison between two samples shows that the kinetic inductance contribution varies strongly with film quality, hence making inductance measurements a crucial part of the SQUID characterization. Thanks to the improved estimation of the kinetic inductance contribution, previously found discrepancies between theoretical estimates and measured values of $V_Φ$ and $S_Φ^{1/2}$ could to a large extent be avoided. We then use the measurements and improved theoretical estimations to optimize the SQUID geometry and reach a noise level of $S_B^{1/2}$ = 44 fT/$\sqrt{\textrm{Hz}}$ for the best SQUID magnetometer with a 8.6 mm $\times$ 9.2 mm directly coupled pickup loop. Lastly, we demonstrate a method for reliable one-time sensor calibration that is constant in a temperature range of several kelvin despite the presence of temperature dependent coupling contributions, such as the kinetic inductance. The found variability of the kinetic inductance contribution has implications not only for the design of YBCO SQUID magnetometers, but for all narrow linewidth SQUID-based devices operated close to their critical temperature.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.