-
Electromagnetic modeling and science reach of DMRadio-m$^3$
Authors:
DMRadio Collaboration,
A. AlShirawi,
C. Bartram,
J. N. Benabou,
L. Brouwer,
S. Chaudhuri,
H. -M. Cho,
J. Corbin,
W. Craddock,
A. Droster,
J. W. Foster,
J. T. Fry,
P. W. Graham,
R. Henning,
K. D. Irwin,
F. Kadribasic,
Y. Kahn,
A. Keller,
R. Kolevatov,
S. Kuenstner,
N. Kurita,
A. F. Leder,
D. Li,
J. L. Ouellet,
K. M. W. Pappas
, et al. (12 additional authors not shown)
Abstract:
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10-200 MHz (41 neV$/c^2$ - 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present…
▽ More
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10-200 MHz (41 neV$/c^2$ - 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m$^3$, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of two larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30-200 MHz can be achieved with a $3σ$ live scan time of 3.7 years.
△ Less
Submitted 27 February, 2023;
originally announced February 2023.
-
Quantum metrology of low frequency electromagnetic modes with frequency upconverters
Authors:
Stephen E. Kuenstner,
Elizabeth C. van Assendelft,
Saptarshi Chaudhuri,
Hsiao-Mei Cho,
Jason Corbin,
Shawn W. Henderson,
Fedja Kadribasic,
Dale Li,
Arran Phipps,
Nicholas M. Rapidis,
Maria Simanovskaia,
Jyotirmai Singh,
Cyndia Yu,
Kent D. Irwin
Abstract:
We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode…
▽ More
We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ($\sim$ 5GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory, and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use non-classical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc--VHF electromagnetic modes as quantum sensors with sensitivity better than the Standard Quantum Limit (SQL). We demonstrate signal upconversion from low frequencies to microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of $46.9$\;dB, which is a necessary step towards the realization of full BAE.
△ Less
Submitted 12 July, 2024; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Projected Sensitivity of DMRadio-m$^3$: A Search for the QCD Axion Below $1\,μ$eV
Authors:
DMRadio Collaboration,
L. Brouwer,
S. Chaudhuri,
H. -M. Cho,
J. Corbin,
W. Craddock,
C. S. Dawson,
A. Droster,
J. W. Foster,
J. T. Fry,
P. W. Graham,
R. Henning,
K. D. Irwin,
F. Kadribasic,
Y. Kahn,
A. Keller,
R. Kolevatov,
S. Kuenstner,
A. F. Leder,
D. Li,
J. L. Ouellet,
K. Pappas,
A. Phipps,
N. M. Rapidis,
B. R. Safdi
, et al. (9 additional authors not shown)
Abstract:
The QCD axion is one of the most compelling candidates to explain the dark matter abundance of the universe. With its extremely small mass ($\ll 1\,\mathrm{eV}/c^2$), axion dark matter interacts as a classical field rather than a particle. Its coupling to photons leads to a modification of Maxwell's equations that can be measured with extremely sensitive readout circuits. DMRadio-m$^3$ is a next-g…
▽ More
The QCD axion is one of the most compelling candidates to explain the dark matter abundance of the universe. With its extremely small mass ($\ll 1\,\mathrm{eV}/c^2$), axion dark matter interacts as a classical field rather than a particle. Its coupling to photons leads to a modification of Maxwell's equations that can be measured with extremely sensitive readout circuits. DMRadio-m$^3$ is a next-generation search for axion dark matter below $1\,μ$eV using a $>4$ T static magnetic field, a coaxial inductive pickup, a tunable LC resonator, and a DC-SQUID readout. It is designed to search for QCD axion dark matter over the range $20\,\mathrm{neV}\lesssim m_ac^2\lesssim 800\,\mathrm{neV}$ ($5\,\mathrm{MHz}<ν<200\,\mathrm{MHz}$). The primary science goal aims to achieve DFSZ sensitivity above $m_ac^2\approx 120$ neV (30 MHz), with a secondary science goal of probing KSVZ axions down to $m_ac^2\approx40\,\mathrm{neV}$ (10 MHz).
△ Less
Submitted 8 December, 2022; v1 submitted 28 April, 2022;
originally announced April 2022.
-
Large-mass single-electron-resolution detector for dark matter and neutrino elastic interaction searches
Authors:
V. Iyer,
N. Mirabolfathi,
G. Agnolet,
H. Chen,
A. Jastram,
F. Kadribasic,
V. K. S. Kashyap,
A. Kubik,
M. Lee,
R. Mahapatra,
B. Mohanty,
H. Neog,
M. Platt
Abstract:
Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$ν$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the or…
▽ More
Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$ν$NS). Here, we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of $\sim 1 e^{-}/h^{+}$ pair and a leakage current on the order of $10^{-16}$ A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CE$ν$NS like searches.
△ Less
Submitted 3 August, 2021; v1 submitted 4 November, 2020;
originally announced November 2020.
-
Crystal Defects: A Portal To Dark Matter Detection
Authors:
Fedja Kadribasic,
Nader Mirabolfathi,
Kai Nordlund,
Flyura Djurabekova
Abstract:
We propose to use the defect creation energy loss in commonly used high energy physics solid state detectors as a tool to statistically identify dark matter signal from background. We simulate the energy loss in the process of defect creation using density functional theory and molecular dynamics methods and calculate the corresponding expected dark matter spectra. We show that in phonon-mediated…
▽ More
We propose to use the defect creation energy loss in commonly used high energy physics solid state detectors as a tool to statistically identify dark matter signal from background. We simulate the energy loss in the process of defect creation using density functional theory and molecular dynamics methods and calculate the corresponding expected dark matter spectra. We show that in phonon-mediated solid state detectors, the energy loss due to defect creation convolved with the expected dark matter interaction signal results in a significant change in the expected spectra for common detector materials. With recent progress towards $\sim$10 eV threshold low-mass dark matter searches, this variation in expected dark matter spectrum can be used as a direct signature of dark matter interactions with atomic nuclei.
△ Less
Submitted 11 February, 2020; v1 submitted 9 February, 2020;
originally announced February 2020.
-
Directional Sensitivity In Light-Mass Dark Matter Searches With Single-Electron Resolution Ionization Detectors
Authors:
Fedja Kadribasic,
Nader Mirabolfathi,
Kai Nordlund,
Andrea E. Sand,
E. Holmström,
Flyura Djurabekova
Abstract:
We propose a method using solid state detectors with directional sensitivity to dark matter interactions to detect low-mass Weakly Interacting Massive Particles (WIMPs) originating from galactic sources. In spite of a large body of literature for high-mass WIMP detectors with directional sensitivity, no available technique exists to cover WIMPs in the mass range <1 GeV. We argue that single-electr…
▽ More
We propose a method using solid state detectors with directional sensitivity to dark matter interactions to detect low-mass Weakly Interacting Massive Particles (WIMPs) originating from galactic sources. In spite of a large body of literature for high-mass WIMP detectors with directional sensitivity, no available technique exists to cover WIMPs in the mass range <1 GeV. We argue that single-electron resolution semiconductor detectors allow for directional sensitivity once properly calibrated. We examine commonly used semiconductor material response to these low-mass WIMP interactions.
△ Less
Submitted 19 March, 2018; v1 submitted 15 March, 2017;
originally announced March 2017.
-
Background Studies for the MINER Coherent Neutrino Scattering Reactor Experiment
Authors:
MINER Collaboration,
G. Agnolet,
W. Baker,
D. Barker,
R. Beck,
T. J. Carroll,
J. Cesar,
P. Cushman,
J. B. Dent,
S. De Rijck,
B. Dutta,
W. Flanagan,
M. Fritts,
Y. Gao,
H. R. Harris,
C. C. Hays,
V. Iyer,
A. Jastram,
F. Kadribasic,
A. Kennedy,
A. Kubik,
I. Ogawa,
K. Lang,
R. Mahapatra,
V. Mandic
, et al. (25 additional authors not shown)
Abstract:
The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 meters) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering proce…
▽ More
The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 meters) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering process and the proposed experimental proximity to the reactor, as many as 5 to 20 events/kg/day are expected. We discuss the status of preliminary measurements to characterize the main backgrounds for the proposed experiment. Both in situ measurements at the experimental site and simulations using the MCNP and GEANT4 codes are described. A strategy for monitoring backgrounds during data taking is briefly discussed.
△ Less
Submitted 7 September, 2016;
originally announced September 2016.