Evaluation of a method for time-of-flight, wavelength and distance calibration for neutron scattering instruments by means of a mini-chopper and standard neutron monitors
Authors:
L. Vergara,
M. Arai,
R. Woracek,
M. Olsson,
A. Quintanilla,
S. Alcock,
J. Nilsson,
K. Kanaki,
P. M. Kadletz,
O. Kirstein,
R. Hall-Wilton,
N. Tsapatsaris
Abstract:
Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the absolute wavelength after any change must always be performed. Inspired by the manner with which neutron spectrometers determine the absolute wavelength, we ev…
▽ More
Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the absolute wavelength after any change must always be performed. Inspired by the manner with which neutron spectrometers determine the absolute wavelength, we evaluate for the first time, in the author's knowledge, a commonly used method for converting TOF to neutron wavelength, the distance of a monitor from the source of neutrons and we analytically calculate the uncertainty contributions that limit the precision of the conversion. The method was evaluated at the V20 test beamline at the Helmholtz Zentrum Berlin (HZB), emulating the ESS source with a pulse of 2.86 ms length and 14 Hz repetition rate, by using a mini-chopper operated at 140 Hz, beam monitors (BMs) and data acquisition infrastructure. The mini-chopper created well-defined neutron pulses and the BM was placed at two positions, enabling the average wavelength of each of the pulses created to be determined. The used experimental setup resulted in absolute wavelength determination at the monitor positions with a $δλ_{mean} / λ_{mean}$ of $\sim$1.8% for $λ>4$ Å. With a modest increase of the distance between the reference monitor positions a $δλ_{mean} / λ_{mean}$ of below 0.5% can be achieved. Further improvements are possible by using a thinner monitor, smaller chopper disc openings and a higher rotational speed chopper. The method requires only two neutron measurements and doesn't necessitate the use of crystals or complex fitting, and could constitute a suitable addition to imaging, diffraction, reflectometers and small angle neutron scattering instruments, at spallation sources, that do not normally utilise fast choppers.
△ Less
Submitted 3 November, 2022;
originally announced November 2022.
-
Spectroscopic Neutron Imaging for Resolving Hydrogen Dynamics Changes in Battery Electrolytes
Authors:
E. R. Carreón Ruiz,
J. Lee,
J. I. Márquez Damián,
M. Strobl,
G. Burca,
R. Woracek,
M. Cochet,
M. -O. Ebert,
L. Höltschi,
P. M. Kadletz,
A. S. Tremsin,
E. Winter,
M. Zlobinski,
L. Gubler,
P. Boillat
Abstract:
We present spectroscopic neutron imaging (SNI), a bridge between imaging and scattering techniques, for the analysis of hydrogenated molecules in lithium-ion cells. The scattering information of CHn-based organic solvents and electrolytes was mapped in two-dimensional space by investigating the wavelength-dependent property of hydrogen atoms through time-of-flight imaging. Our investigation demons…
▽ More
We present spectroscopic neutron imaging (SNI), a bridge between imaging and scattering techniques, for the analysis of hydrogenated molecules in lithium-ion cells. The scattering information of CHn-based organic solvents and electrolytes was mapped in two-dimensional space by investigating the wavelength-dependent property of hydrogen atoms through time-of-flight imaging. Our investigation demonstrates a novel approach to detect physical and chemical changes in hydrogenated liquids, which extends, but not limits, the use of SNI to relevant applications in electrochemical devices, e.g., the study of electrolytes in Li-ion batteries.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
Time- and energy-resolved effects in the boron-10 based Multi-Grid and helium-3 based thermal neutron detectors
Authors:
A. Backis,
A. Khaplanov,
R. Al Jebali,
R. Ammer,
I. Apostolidis,
J. Birch,
C. -C. Lai,
P. P. Deen,
M. Etxegarai,
N. de Ruette,
J. Freita Ramos,
D. F. Förster,
E. Haettner,
R. Hall-Wilton,
D. Hamilton,
C. Höglund,
P. M. Kadletz,
K. Kanaki,
E. Karnickis,
O. Kirstein,
S. Kolya,
Z. Kraujalyte,
A. Laloni,
K. Livingston,
O. Löhman
, et al. (11 additional authors not shown)
Abstract:
The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few $μ$eV, while comparing…
▽ More
The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few $μ$eV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of ~ $μ$s short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of $μ$s wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.
△ Less
Submitted 14 January, 2021; v1 submitted 2 June, 2020;
originally announced June 2020.
-
Revisiting neutron propagation-based phase contrast imaging and tomography: use of phase retrieval to amplify the effective degree of brilliance
Authors:
David M. Paganin,
Morten Sales,
Peter M. Kadletz,
Winfried Kockelmann,
Mario A. Beltran,
Henning F. Poulsen,
Søren Schmidt
Abstract:
Propagation-based neutron phase-contrast tomography was demonstrated using the ISIS pulsed spallation source. The proof-of-concept tomogram with Paganin-type phase-retrieval filter applied exhibited an effective net boost of $23\pm 1$ in the signal-to-noise ratio as compared to an attenuation-based tomogram, implying a boost in the effective degree of neutron brilliance of over two orders of magni…
▽ More
Propagation-based neutron phase-contrast tomography was demonstrated using the ISIS pulsed spallation source. The proof-of-concept tomogram with Paganin-type phase-retrieval filter applied exhibited an effective net boost of $23\pm 1$ in the signal-to-noise ratio as compared to an attenuation-based tomogram, implying a boost in the effective degree of neutron brilliance of over two orders of magnitude. This comparison is for phase retrieval versus conventional absorption with no additional collimation in place. Expressions are provided for the optimal phase-contrast geometry as well as conditions for the validity of the method. The underpinning theory is derived under the assumption of the sample being composed of a single material. The effective boost in brilliance may be employed to give reduced acquisition time, or may instead be used to keep exposure times fixed while improving the measured contrast.
△ Less
Submitted 11 October, 2022; v1 submitted 22 September, 2019;
originally announced September 2019.
-
Time-of-Flight Three Dimensional Neutron Diffraction in Transmission Mode for Map** Crystal Grain Structures
Authors:
Alberto Cereser,
Markus Strobl,
Stephen Hall,
Axel Steuwer,
Ryoji Kiyanagi,
Anton Tremsin,
Erik Bergbäck Knudsen,
Takenao Shinohara,
Peter Willendrup,
Alice Bastos da Silva Fanta,
Srinivasan Iyengar,
Peter Mahler Larsen,
Takayasu Hanashima,
Taketo Moyoshi,
Peter M. Kadletz,
Philip Krooß,
Thomas Niendorf,
Morten Sales,
Wolfgang W. Schmahl,
Søren Schmidt
Abstract:
The physical properties of polycrystalline materials depend on their microstructure, which is the nano-to-centimeter-scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study bulk samples with s…
▽ More
The physical properties of polycrystalline materials depend on their microstructure, which is the nano-to-centimeter-scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study bulk samples with sizes in the cm range with a resolution of hundred micrometers: time-of-flight three-dimensional neutron diffraction (ToF 3DND). Compared to existing analogous X-ray diffraction techniques, ToF 3DND enables studies of samples that can be both larger in size and made of heavier elements. Moreover, ToF 3DND facilitates the use of complicated sample environments. The basic ToF 3DND setup, utilizing an imaging detector with high spatial and temporal resolution, can easily be implemented at a time-of-flight neutron beamline. The technique was developed and tested with data collected at the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Complex (J-PARC) for an iron sample. We successfully reconstructed the shape of 108 grains and developed an indexing procedure. The reconstruction algorithms have been validated by reconstructing two stacked Co-Ni-Ga single crystals and by comparison with a grain map obtained by post-mortem electron backscatter diffraction (EBSD).
△ Less
Submitted 20 April, 2017;
originally announced April 2017.