-
Single Particle Detection System for Strong-Field QED Experiments
Authors:
F. C. Salgado,
N. Cavanagh,
M. Tamburini,
D. W. Storey,
R. Beyer,
P. H. Bucksbaum,
Z. Chen,
A. Di Piazza,
E. Gerstmayr,
Harsh,
E. Isele,
A. R. Junghans,
C. H. Keitel,
S. Kuschel,
C. F. Nielsen,
D. A. Reis,
C. Roedel,
G. Sarri,
A. Seidel,
C. Schneider,
U. I. Uggerhøj,
J. Wulff,
V. Yakimenko,
C. Zepter,
S. Meuren
, et al. (1 additional authors not shown)
Abstract:
Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and $γ$-photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED inte…
▽ More
Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and $γ$-photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.
△ Less
Submitted 9 December, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
The new Felsenkeller 5 MV underground accelerator
Authors:
Daniel Bemmerer,
Thomas E. Cowan,
Alexander Domula,
Toralf Döring,
Marcel Grieger,
Sebastian Hammer,
Thomas Hensel,
Lisa Hübinger,
Arnd R. Junghans,
Felix Ludwig,
Stefan E. Müller,
Stefan Reinicke,
Bernd Rimarzig,
Konrad Schmidt,
Ronald Schwengner,
Klaus Stöckel,
Tamás Szücs,
Steffen Turkat,
Andreas Wagner,
Louis Wagner,
Kai Zuber
Abstract:
The field of nuclear astrophysics is devoted to the study of the creation of the chemical elements. By nature, it is deeply intertwined with the physics of the Sun. The nuclear reactions of the proton-proton cycle of hydrogen burning, including the 3He(α,γ)7Be reaction, provide the necessary nuclear energy to prevent the gravitational collapse of the Sun and give rise to the by now well-studied pp…
▽ More
The field of nuclear astrophysics is devoted to the study of the creation of the chemical elements. By nature, it is deeply intertwined with the physics of the Sun. The nuclear reactions of the proton-proton cycle of hydrogen burning, including the 3He(α,γ)7Be reaction, provide the necessary nuclear energy to prevent the gravitational collapse of the Sun and give rise to the by now well-studied pp, 7Be, and 8B solar neutrinos. The not yet measured flux of 13N, 15O, and 17F neutrinos from the carbon-nitrogen-oxygen cycle is affected in rate by the 14N(p,γ)15O reaction and in emission profile by the 12C(p,γ)13N reaction. The nucleosynthetic output of the subsequent phase in stellar evolution, helium burning, is controlled by the 12C(α,γ)16O reaction.
In order to properly interpret the existing and upcoming solar neutrino data, precise nuclear physics information is needed. For nuclear reactions between light, stable nuclei, the best available technique are experiments with small ion accelerators in underground, low-background settings. The pioneering work in this regard has been done by the LUNA collaboration at Gran Sasso/Italy, using a 0.4 MV accelerator.
The present contribution reports on a higher-energy, 5.0 MV, underground accelerator in the Felsenkeller underground site in Dresden/Germany. Results from γ-ray, neutron, and muon background measurements in the Felsenkeller underground site in Dresden, Germany, show that the background conditions are satisfactory for nuclear astrophysics purposes. The accelerator is in the commissioning phase and will provide intense, up to 50μA, beams of 1H+, 4He+ , and 12C+ ions, enabling research on astrophysically relevant nuclear reactions with unprecedented sensitivity.
△ Less
Submitted 14 November, 2018; v1 submitted 18 October, 2018;
originally announced October 2018.
-
Progress of the Felsenkeller shallow-underground accelerator for nuclear astrophysics
Authors:
D. Bemmerer,
F. Cavanna,
T. E. Cowan,
M. Grieger,
T. Hensel,
A. R. Junghans,
F. Ludwig,
S. E. Müller,
B. Rimarzig,
S. Reinicke,
S. Schulz,
R. Schwengner,
K. Stöckel,
T. Szücs,
M. P. Takács,
A. Wagner,
L. Wagner,
K. Zuber
Abstract:
Low-background experiments with stable ion beams are an important tool for putting the model of stellar hydrogen, helium, and carbon burning on a solid experimental foundation. The pioneering work in this regard has been done by the LUNA collaboration at Gran Sasso, using a 0.4 MV accelerator. In the present contribution, the status of the project for a higher-energy underground accelerator is rev…
▽ More
Low-background experiments with stable ion beams are an important tool for putting the model of stellar hydrogen, helium, and carbon burning on a solid experimental foundation. The pioneering work in this regard has been done by the LUNA collaboration at Gran Sasso, using a 0.4 MV accelerator. In the present contribution, the status of the project for a higher-energy underground accelerator is reviewed. Two tunnels of the Felsenkeller underground site in Dresden, Germany, are currently being refurbished for the installation of a 5 MV high-current Pelletron accelerator. Construction work is on schedule and expected to complete in August 2017. The accelerator will provide intense, 50 uA, beams of 1H+, 4He+, and 12C+ ions, enabling research on astrophysically relevant nuclear reactions with unprecedented sensitivity.
△ Less
Submitted 16 September, 2016;
originally announced September 2016.
-
Measurement of $α$-particle quenching in LAB based scintillator in independent small-scale experiments
Authors:
B. von Krosigk,
M. Chen,
S. Hans,
A. R. Junghans,
T. Kögler,
C. Kraus,
L. Kuckert,
X. Liu,
R. Nolte,
H. M. O'Keeffe,
H. S. Wan Chan Tseung,
J. R. Wilson,
A. Wright,
M. Yeh,
K. Zuber
Abstract:
The $α$-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, $α$-particles were produced in the scintillator via $^{12}$C($n$,$α$)$^9$Be reactions. In the second approach, the scintillator was loaded with 2% of $^{\mathrm{nat}}$Sm providing an $α$-emitter, $^{147}$Sm, as an internal…
▽ More
The $α$-particle light response of liquid scintillators based on linear alkylbenzene (LAB) has been measured with three different experimental approaches. In the first approach, $α$-particles were produced in the scintillator via $^{12}$C($n$,$α$)$^9$Be reactions. In the second approach, the scintillator was loaded with 2% of $^{\mathrm{nat}}$Sm providing an $α$-emitter, $^{147}$Sm, as an internal source. In the third approach, a scintillator flask was deployed into the water-filled SNO+ detector and the radioactive contaminants $^{222}$Rn, $^{218}$Po and $^{214}$Po provided the $α$-particle signal. The behavior of the observed $α$-particle light outputs are in agreement with each case successfully described by Birks' law. The resulting Birks parameter $kB$ ranges from $(0.0066\pm0.0016)$ cm/MeV to $(0.0076\pm0.0003)$ cm/MeV. In the first approach, the $α$-particle light response was measured simultaneously with the light response of recoil protons produced via neutron-proton elastic scattering. This enabled a first time a direct comparison of $kB$ describing the proton and the $α$-particle response of LAB based scintillator. The observed $kB$ values describing the two light response functions deviate by more than $5σ$. The presented results are valuable for all current and future detectors, using LAB based scintillator as target, since they depend on an accurate knowledge of the scintillator response to different particles.
△ Less
Submitted 13 March, 2016; v1 submitted 1 October, 2015;
originally announced October 2015.