-
MRI-MECH: Mechanics-informed MRI to estimate esophageal health
Authors:
Sourav Halder,
Ethan M. Johnson,
Jun Yamasaki,
Peter J. Kahrilas,
Michael Markl,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Dynamic magnetic resonance imaging (MRI) is a popular medical imaging technique to generate image sequences of the flow of a contrast material inside tissues and organs. However, its application to imaging bolus movement through the esophagus has only been demonstrated in few feasibility studies and is relatively unexplored. In this work, we present a computational framework called mechanics-infor…
▽ More
Dynamic magnetic resonance imaging (MRI) is a popular medical imaging technique to generate image sequences of the flow of a contrast material inside tissues and organs. However, its application to imaging bolus movement through the esophagus has only been demonstrated in few feasibility studies and is relatively unexplored. In this work, we present a computational framework called mechanics-informed MRI (MRI-MECH) that enhances that capability thereby increasing the applicability of dynamic MRI for diagnosing esophageal disorders. Pineapple juice was used as the swallowed contrast material for the dynamic MRI and the MRI image sequence was used as input to the MRI-MECH. The MRI-MECH modeled the esophagus as a flexible one-dimensional tube and the elastic tube walls followed a linear tube law. Flow through the esophagus was then governed by one-dimensional mass and momentum conservation equations. These equations were solved using a physics-informed neural network (PINN). The PINN minimized the difference between the measurements from the MRI and model predictions ensuring that the physics of the fluid flow problem was always followed. MRI-MECH calculated the fluid velocity and pressure during esophageal transit and estimated the mechanical health of the esophagus by calculating wall stiffness and active relaxation. Additionally, MRI-MECH predicted missing information about the lower esophageal sphincter during the emptying process, demonstrating its applicability to scenarios with missing data or poor image resolution. In addition to potentially improving clinical decisions based on quantitative estimates of the mechanical health of the esophagus, MRI-MECH can also be enhanced for application to other medical imaging modalities to enhance their functionality as well.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.
-
Fluid-structure instability forecasts thoracic aortic aneurysm progression
Authors:
Tom Y. Zhao,
Ethan M. I. Johnson,
Guy Elisha,
Sourav Halder,
Ben C. Smith,
Bradley D. Allen,
Michael Markl,
Neelesh A. Patankar
Abstract:
The basic mechanism driving aneurysm growth is unknown. Currently, clinical diagnosis of an aneurysm is mainly informed by retrospective tracking of its size and growth rate. However, aneurysms can rupture before reactive criteria are met or remain stable when they are exceeded. Here, we identify a fluid-structure instability that is associated with abnormal aortic dilatation. Our analysis yields…
▽ More
The basic mechanism driving aneurysm growth is unknown. Currently, clinical diagnosis of an aneurysm is mainly informed by retrospective tracking of its size and growth rate. However, aneurysms can rupture before reactive criteria are met or remain stable when they are exceeded. Here, we identify a fluid-structure instability that is associated with abnormal aortic dilatation. Our analysis yields a measurable dimensionless number and its analytically derived critical threshold. This threshold pinpoints the transition from stable flow to unstable aortic fluttering as a function of the physiological properties composing the dimensionless number, like blood pressure and aortic compliance. A retrospective study was then conducted with 4D-flow MRI data from 117 patients indicated for cardiac imaging and 100 healthy volunteers recruited prospectively. The difference between the dimensionless number and its critical threshold was calculated for every subject from their earliest MRI data and used as an aneurysm physiomarker to forecast future growth. As a binary predictor for abnormal growth and subsequent surgical intervention reported from follow-up imaging, the aneurysm physiomarker yielded an AUC of 0.997 in a receiving operator characteristic analysis. Though validated here for thoracic ascending aortic aneurysms, this instability mechanism may be used to understand, predict and inform patient-specific treatment of aneurysms in any location without fundamental differences.
△ Less
Submitted 7 August, 2023; v1 submitted 18 November, 2021;
originally announced November 2021.
-
Least Squares Optimal Density Compensation for the Gridding Non-uniform Discrete Fourier Transform
Authors:
Nicholas Dwork,
Daniel O'Connor,
Ethan M. I. Johnson,
Corey A. Baron,
Jeremy W. Gordon,
John M. Pauly,
Peder E. Z. Larson
Abstract:
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measu…
▽ More
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measure 0) in the optimization. This manuscript presents the first density compensation algorithm for a general trajectory that takes into account the point spread function over a set of non-zero measure. We show that the images reconstructed with Gridding using the density compensation values of this method are of superior quality when compared to density compensation weights determined in other ways. Results are shown with a numerical phantom and with magnetic resonance images of the abdomen and the knee.
△ Less
Submitted 16 June, 2021; v1 submitted 11 June, 2021;
originally announced June 2021.