-
Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
Authors:
KamLAND,
Super-Kamiokande Collaborations,
:,
Seisho Abe,
Minori Eizuka,
Sawako Futagi,
Azusa Gando,
Yoshihito Gando,
Shun Goto,
Takahiko Hachiya,
Kazumi Hata,
Koichi Ichimura,
Sei Ieki,
Haruo Ikeda,
Kunio Inoue,
Koji Ishidoshiro,
Yuto Kamei,
Nanami Kawada,
Yasuhiro Kishimoto,
Masayuki Koga,
Maho Kurasawa,
Tadao Mitsui,
Haruhiko Miyake,
Daisuke Morita,
Takeshi Nakahata
, et al. (290 additional authors not shown)
Abstract:
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are ob…
▽ More
Preceding a core-collapse supernova, various processes produce an increasing amount of neutrinos of all flavors characterized by mounting energies from the interior of massive stars. Among them, the electron antineutrinos are potentially detectable by terrestrial neutrino experiments such as KamLAND and Super-Kamiokande via inverse beta decay interactions. Once these pre-supernova neutrinos are observed, an early warning of the upcoming core-collapse supernova can be provided. In light of this, KamLAND and Super-Kamiokande, both located in the Kamioka mine in Japan, have been monitoring pre-supernova neutrinos since 2015 and 2021, respectively. Recently, we performed a joint study between KamLAND and Super-Kamiokande on pre-supernova neutrino detection. A pre-supernova alert system combining the KamLAND detector and the Super-Kamiokande detector was developed and put into operation, which can provide a supernova alert to the astrophysics community. Fully leveraging the complementary properties of these two detectors, the combined alert is expected to resolve a pre-supernova neutrino signal from a 15 M$_{\odot}$ star within 510 pc of the Earth, at a significance level corresponding to a false alarm rate of no more than 1 per century. For a Betelgeuse-like model with optimistic parameters, it can provide early warnings up to 12 hours in advance.
△ Less
Submitted 1 July, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Second gadolinium loading to Super-Kamiokande
Authors:
K. Abe,
C. Bronner,
Y. Hayato,
K. Hiraide,
K. Hosokawa,
K. Ieki,
M. Ikeda,
J. Kameda,
Y. Kanemura,
R. Kaneshima,
Y. Kashiwagi,
Y. Kataoka,
S. Miki,
S. Mine,
M. Miura,
S. Moriyama,
Y. Nakano,
M. Nakahata,
S. Nakayama,
Y. Noguchi,
K. Sato,
H. Sekiya,
H. Shiba,
K. Shimizu,
M. Shiozawa
, et al. (225 additional authors not shown)
Abstract:
The first loading of gadolinium (Gd) into Super-Kamiokande in 2020 was successful, and the neutron capture efficiency on Gd reached 50\%. To further increase the Gd neutron capture efficiency to 75\%, 26.1 tons of $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was additionally loaded into Super-Kamiokande (SK) from May 31 to July 4, 2022. As the amount of loaded $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was do…
▽ More
The first loading of gadolinium (Gd) into Super-Kamiokande in 2020 was successful, and the neutron capture efficiency on Gd reached 50\%. To further increase the Gd neutron capture efficiency to 75\%, 26.1 tons of $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was additionally loaded into Super-Kamiokande (SK) from May 31 to July 4, 2022. As the amount of loaded $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$ was doubled compared to the first loading, the capacity of the powder dissolving system was doubled. We also developed new batches of gadolinium sulfate with even further reduced radioactive impurities. In addition, a more efficient screening method was devised and implemented to evaluate these new batches of $\rm Gd_2(\rm SO_4)_3\cdot \rm 8H_2O$. Following the second loading, the Gd concentration in SK was measured to be $333.5\pm2.5$ ppm via an Atomic Absorption Spectrometer (AAS). From the mean neutron capture time constant of neutrons from an Am/Be calibration source, the Gd concentration was independently measured to be 332.7 $\pm$ 6.8(sys.) $\pm$ 1.1(stat.) ppm, consistent with the AAS result. Furthermore, during the loading the Gd concentration was monitored continually using the capture time constant of each spallation neutron produced by cosmic-ray muons,and the final neutron capture efficiency was shown to become 1.5 times higher than that of the first loaded phase, as expected.
△ Less
Submitted 18 June, 2024; v1 submitted 12 March, 2024;
originally announced March 2024.
-
Characterization of Charge Spreading and Gain of Encapsulated Resistive Micromegas Detectors for the Upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attie,
O. Ballester,
M. Batkiewicz-Kwasnia,
P. Billoir,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
D. D Ago,
C. Dalmazzon,
T. Daret,
A. Delbart,
A. De Lorenzis,
R. de Oliveira,
S. Dolan,
K. Dygnarowiczi,
J. Dumarchez,
S. Emery-Schren,
A. Ershova
, et al. (70 additional authors not shown)
Abstract:
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and relia…
▽ More
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and reliable operation of the detectors once installed. A dedicated X-ray test bench is used to characterize the detectors by scanning each pad individually and to precisely measure the uniformity of the gain and the deposited energy resolution over the pad plane. An energy resolution of about 10% is obtained. A detailed physical model has been developed to describe the charge dispersion phenomena in the resistive Micromegas anode. The detailed physical description includes initial ionization, electron drift, diffusion effects and the readout electronics effects. The model provides an excellent characterization of the charge spreading of the experimental measurements and allowed the simultaneous extraction of gain and RC information of the modules.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Lead perovskites as CE$ν$NS detectors
Authors:
César Jesús-Valls,
Federico Sánchez
Abstract:
The recent discovery of Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) has created new opportunities to detect and study neutrinos. The interaction cross-section in CE$ν$NS scales quadratically with the number of neutrons, making heavy-nuclei targets such as active lead-based detectors ideal. In this Letter, we discuss for the first time the potential of semiconductor lead perovskites for…
▽ More
The recent discovery of Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) has created new opportunities to detect and study neutrinos. The interaction cross-section in CE$ν$NS scales quadratically with the number of neutrons, making heavy-nuclei targets such as active lead-based detectors ideal. In this Letter, we discuss for the first time the potential of semiconductor lead perovskites for building neutrino detectors. Lead perovskites have emerged in the last decade as revolutionary materials for radiation detection due to their heavy and flexible element composition and their unique optoelectronic properties that result in an excellent energy resolution at an economic cost. While dedicated research and development will be necessary, we find great benefits and no inherent obstacles for the development of lead perovskites as CE$ν$NS detectors.
△ Less
Submitted 14 February, 2023; v1 submitted 3 February, 2023;
originally announced February 2023.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Analysis of test beam data taken with a prototype of TPC with resistive Micromegas for the T2K Near Detector upgrade
Authors:
D. Attié,
O. Ballester,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
C. Dalmazzone,
T. Daret,
A. Delbart,
A. De Lorenzis,
S. Dolan,
K. Dygnarowicz,
J. Dumarchez,
S. Emery-Schrenk,
A. Ershova,
G. Eurin
, et al. (59 additional authors not shown)
Abstract:
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection…
▽ More
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection of the charge emitted by ionization electrons over several pads, improving the determination of the track position. The TPC prototype has been equipped with the first ERAM module produced for T2K and with the HA-TPC readout electronics chain and it has been exposed to the DESY Test Beam in order to measure spatial and dE/dx resolution. In this paper we characterize the performances of the ERAM and, for the first time, we compare them with a newly developed simulation of the detector response. Spatial resolution better than 800 ${μ\rm m}$ and dE/dx resolution better than 10% are observed for all the incident angles and for all the drift distances of interest. All the main features of the data are correctly reproduced by the simulation and these performances fully fulfill the requirements for the HA-TPCs of T2K.
△ Less
Submitted 16 May, 2023; v1 submitted 13 December, 2022;
originally announced December 2022.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Scintillator ageing of the T2K near detectors from 2010 to 2021
Authors:
The T2K Collaboration,
K. Abe,
N. Akhlaq,
R. Akutsu,
A. Ali,
C. Alt,
C. Andreopoulos,
M. Antonova,
S. Aoki,
T. Arihara,
Y. Asada,
Y. Ashida,
E. T. Atkin,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
D. Barrow,
M. Batkiewicz-Kwasniak,
F. Bench,
V. Berardi,
L. Berns,
S. Bhadra,
A. Blanchet,
A. Blondel
, et al. (333 additional authors not shown)
Abstract:
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9--2.2\% per year. Extrapolation of the degradation…
▽ More
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9--2.2\% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
Total Neutron Cross-section Measurement on CH with a Novel 3D-projection Scintillator Detector
Authors:
A. Agarwal,
H. Budd,
J. Capo,
J. Chaves,
P. Chong,
G. Christodoulou,
M. Danilov,
A. Dergacheva,
A. De Roeck,
N. Dokania,
D. Douqa,
K. Dugas,
S. Fedotov,
S. Gwon,
R. Howell,
K. Iwamoto,
C. Jesus-Valls,
C. K. Jung,
S. P. Kasetti,
M. Khabibullin,
A. Khotjantsev,
T. Kikawa,
U. Kose,
Y. Kudenko,
S. Kuribayashi
, et al. (37 additional authors not shown)
Abstract:
In order to extract neutrino oscillation parameters, precision long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the ne…
▽ More
In order to extract neutrino oscillation parameters, precision long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 $\pm$ 0.05 barn.
△ Less
Submitted 23 June, 2023; v1 submitted 28 June, 2022;
originally announced July 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
SuperFGD prototype time resolution studies
Authors:
I. Alekseev,
T. Arihara,
V. Baranov,
L. Bartoszek,
L. Bernardi,
A. Blondel,
A. V. Boikov,
M. Buizza-Avanzini,
F. Cadoux,
J. Capó,
J. Cayo,
J. Chakrani,
P. S. Chong,
A. Chvirova,
M. Danilov,
Yu. I. Davydov,
A. Dergacheva,
N. Dokania,
D. Douqa,
O. Drapier,
A. Eguchi,
Y. Favre,
D. Fedorova,
S. Fedotov,
Y. Fujii
, et al. (65 additional authors not shown)
Abstract:
The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the f…
▽ More
The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.
△ Less
Submitted 18 January, 2023; v1 submitted 21 June, 2022;
originally announced June 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Data-driven detector signal characterization with constrained bottleneck autoencoders
Authors:
César Jesús-Valls,
Thorsten Lux,
Federico Sánchez
Abstract:
A common technique in high energy physics is to characterize the response of a detector by means of models tunned to data which build parametric maps from the physical parameters of the system to the expected signal of the detector. When the underlying model is unknown it is difficult to apply this method, and often, simplifying assumptions are made introducing modeling errors. In this article, us…
▽ More
A common technique in high energy physics is to characterize the response of a detector by means of models tunned to data which build parametric maps from the physical parameters of the system to the expected signal of the detector. When the underlying model is unknown it is difficult to apply this method, and often, simplifying assumptions are made introducing modeling errors. In this article, using a waveform toy model we present how deep learning in the form of constrained bottleneck autoencoders can be used to learn the underlying unknown detector response model directly from data. The results show that excellent performance results can be achieved even when the signals are significantly affected by random noise. The trained algorithm can be used simultaneously to perform estimations on the physical parameters of the model, simulate the detector response with high fidelity and to denoise detector signals.
△ Less
Submitted 27 April, 2022; v1 submitted 9 March, 2022;
originally announced March 2022.
-
A novel range telescope concept for proton CT
Authors:
Marc Granado-González,
César Jesús-Valls,
Thorsten Lux,
Tony Price,
Federico Sánchez
Abstract:
Proton beam therapy can potentially offer improved treatment for cancers of the head and neck and in paediatric patients. There has been a sharp uptake of proton beam therapy in recent years as improved delivery techniques and patient benefits are observed. However, treatments are currently planned using conventional x-ray CT images due to the absence of devices able to perform high quality proton…
▽ More
Proton beam therapy can potentially offer improved treatment for cancers of the head and neck and in paediatric patients. There has been a sharp uptake of proton beam therapy in recent years as improved delivery techniques and patient benefits are observed. However, treatments are currently planned using conventional x-ray CT images due to the absence of devices able to perform high quality proton computed tomography (pCT) under realistic clinical conditions. A new plastic-scintillator-based range telescope concept, named ASTRA, is proposed here to measure the proton's energy loss in a pCT system. Simulations conducted using GEANT4 yield an expected energy resolution of 0.7\%. If calorimetric information is used the energy resolution could be further improved to about $0.5\%$. In addition, the ability of ASTRA to track multiple protons simultaneously is presented. Due to its fast components, ASTRA is expected to reach unprecedented data collection rates, similar to $10^8$ protons/s. The performance of ASTRA has also been tested by simulating the imaging of phantoms. The results show excellent image contrast and relative stop** power reconstruction.
△ Less
Submitted 26 November, 2021; v1 submitted 8 September, 2021;
originally announced September 2021.
-
Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1132 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on t…
▽ More
The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3$σ$ (5$σ$) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3$σ$ level with a 100 kt-MW-yr exposure for the maximally CP-violating values $δ_{\rm CP}} = \pmπ/2$. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1158 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA.…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, USA. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of $7\times 6\times 7.2$~m$^3$. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components.
△ Less
Submitted 23 September, 2021; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Characterization of resistive Micromegas detectors for the upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attié,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
D. Calvet,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
A. Delbart,
J. Dumarchez,
S. Emery-Schrenk,
M. Feltre,
C. Giganti,
F. Gramegna,
M. Grassi,
M. Guigue,
P. Hamacher-Baumann,
S. Hassani,
F. Iacob,
C. Jesús-Valls,
R. Kurjata
, et al. (36 additional authors not shown)
Abstract:
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure u…
▽ More
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure uses a resistive anode to spread the charges over several pads to improve the space point resolution. This innovative technique is combined with the bulk-Micromegas technology to compose the "Encapsulated Resistive Anode Micromegas" detector. A prototype has been designed, built and exposed to an electron beam at the DESY II test beam facility.
The data have been used to characterize the charge spreading and to produce a RC map. Spatial resolution better than 600 $μ$m and energy resolution better than 9% are obtained for all incident angles. These performances fulfil the requirements for the upgrade of the ND280 TPC.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.
-
Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report
Authors:
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
N. Anfimov,
A. Ankowski,
M. Antonova,
S. Antusch
, et al. (1041 additional authors not shown)
Abstract:
This report describes the conceptual design of the DUNE near detector
This report describes the conceptual design of the DUNE near detector
△ Less
Submitted 25 March, 2021;
originally announced March 2021.
-
Graph neural network for 3D classification of ambiguities and optical crosstalk in scintillator-based neutrino detectors
Authors:
Saúl Alonso-Monsalve,
Dana Douqa,
César Jesús-Valls,
Thorsten Lux,
Sebastian Pina-Otey,
Federico Sánchez,
Davide Sgalaberna,
Leigh H. Whitehead
Abstract:
Deep learning tools are being used extensively in high energy physics and are becoming central in the reconstruction of neutrino interactions in particle detectors. In this work, we report on the performance of a graph neural network in assisting with particle flow event reconstruction. The three-dimensional reconstruction of particle tracks produced in neutrino interactions can be subject to ambi…
▽ More
Deep learning tools are being used extensively in high energy physics and are becoming central in the reconstruction of neutrino interactions in particle detectors. In this work, we report on the performance of a graph neural network in assisting with particle flow event reconstruction. The three-dimensional reconstruction of particle tracks produced in neutrino interactions can be subject to ambiguities due to high multiplicity signatures in the detector or leakage of signal between neighboring active detector volumes. Graph neural networks potentially have the capability of identifying all these features to boost the reconstruction performance. As an example case study, we tested a graph neural network, inspired by the GraphSAGE algorithm, on a novel 3D-granular plastic-scintillator detector, that will be used to upgrade the near detector of the T2K experiment. The developed neural network has been trained and tested on diverse neutrino interaction samples, showing very promising results: the classification of particle track voxels produced in the detector can be done with efficiencies and purities of 94-96% per event and most of the ambiguities can be identified and rejected, while being robust against systematic effects.
△ Less
Submitted 4 February, 2021; v1 submitted 1 September, 2020;
originally announced September 2020.
-
The SuperFGD Prototype Charged Particle Beam Tests
Authors:
A. Blondel,
M. Bogomilov,
S. Bordoni,
F. Cadoux,
D. Douqa,
K. Dugas,
T. Ekelof,
Y. Favre,
S. Fedotov,
K. Fransson,
R. Fujita,
E. Gramstad,
A. K. Ichikawa,
S. Ilieva,
K. Iwamoto,
C. Jesus-Valls,
C. K. Jung,
S. P. Kasetti,
M. Khabibullin,
A. Khotjantsev,
A. Korzenev,
A. Kostin,
Y. Kudenko,
T. Kutter,
T. Lux
, et al. (25 additional authors not shown)
Abstract:
A novel scintillator detector, the SuperFGD, has been selected as the main neutrino target for an upgrade of the T2K experiment ND280 near detector. The detector design will allow nearly 4π coverage for neutrino interactions at the near detector and will provide lower energy thresholds, significantly reducing systematic errors for the experiment. The SuperFGD is made of optically-isolated scintill…
▽ More
A novel scintillator detector, the SuperFGD, has been selected as the main neutrino target for an upgrade of the T2K experiment ND280 near detector. The detector design will allow nearly 4π coverage for neutrino interactions at the near detector and will provide lower energy thresholds, significantly reducing systematic errors for the experiment. The SuperFGD is made of optically-isolated scintillator cubes of size 10x10x10 mm^3, providing the required spatial and energy resolution to reduce systematic uncertainties for future T2K runs. The SuperFGD for T2K will have close to two million cubes in a 1920x560x1840 mm^3 volume. A prototype made of 24x8x48 cubes was tested at a charged particle beamline at the CERN PS facility. The SuperFGD Prototype was instrumented with readout electronics similar to the future implementation for T2K. Results on electronics and detector response are reported in this paper, along with a discussion of the 3D reconstruction capabilities of this type of detector. Several physics analyses with the prototype data are also discussed, including a study of stop** protons.
△ Less
Submitted 7 September, 2020; v1 submitted 20 August, 2020;
originally announced August 2020.
-
Supernova Neutrino Burst Detection with the Deep Underground Neutrino Experiment
Authors:
DUNE collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (949 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The gen…
▽ More
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The general capabilities of DUNE for neutrino detection in the relevant few- to few-tens-of-MeV neutrino energy range will be described. As an example, DUNE's ability to constrain the $ν_e$ spectral parameters of the neutrino burst will be considered.
△ Less
Submitted 29 May, 2021; v1 submitted 15 August, 2020;
originally announced August 2020.
-
First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform
Authors:
DUNE Collaboration,
B. Abi,
A. Abed Abud,
R. Acciarri,
M. A. Acero,
G. Adamov,
M. Adamowski,
D. Adams,
P. Adrien,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga
, et al. (970 additional authors not shown)
Abstract:
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of $7.2\times 6.0\times 6.9$ m$^3$. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV$/c$ to 7 GeV/$c$. Beam line instrumentation provides accurate momentum measurements…
▽ More
The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of $7.2\times 6.0\times 6.9$ m$^3$. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV$/c$ to 7 GeV/$c$. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, $dE/dx$ calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.
△ Less
Submitted 3 June, 2021; v1 submitted 13 July, 2020;
originally announced July 2020.
-
Neutrino interaction classification with a convolutional neural network in the DUNE far detector
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (951 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure $CP$-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electr…
▽ More
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure $CP$-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electron neutrino (antineutrino) selection efficiency peaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between 2-5 GeV. The muon neutrino (antineutrino) event selection is found to have a maximum efficiency of 96% (97%) and exceeds 90% (95%) efficiency for reconstructed neutrino energies above 2 GeV. When considering all electron neutrino and antineutrino interactions as signal, a selection purity of 90% is achieved. These event selections are critical to maximize the sensitivity of the experiment to $CP$-violating effects.
△ Less
Submitted 10 November, 2020; v1 submitted 26 June, 2020;
originally announced June 2020.
-
Performances of two resistive MicroMegas prototypes for the Time Projection Chambers of the T2K Near Detector upgrade
Authors:
C. Jesús-Valls
Abstract:
T2K is a long baseline neutrino experiment that has been operating since 2009 providing some of the world-wide leading measurements for neutrino oscillation parameters. An upgrade for the Near Detector, ND280, of T2K has been proposed. It includes the installation of two new Time Projection Chambers (TPC) based on a new read-out technology: the resistive anode MicroMegas (RMM). This technology is…
▽ More
T2K is a long baseline neutrino experiment that has been operating since 2009 providing some of the world-wide leading measurements for neutrino oscillation parameters. An upgrade for the Near Detector, ND280, of T2K has been proposed. It includes the installation of two new Time Projection Chambers (TPC) based on a new read-out technology: the resistive anode MicroMegas (RMM). This technology is expected to reduce the number of electronic channels while maintaining or improving the current ND280 TPCs' bulk MicroMegas perfomance. A series of tests have been performed and further studies are ongoing to validate this approach. Two RMM prototypes were studied in dedicated beamtests. All results so far, some of them still preliminary, indicate that a better performance can be achieved, even with larger pads, thanks to the advantages of RMM.
△ Less
Submitted 12 May, 2020;
originally announced May 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume IV: Far Detector Single-phase Technology
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-clas…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
Central to achieving DUNE's physics program is a far detector that combines the many tens-of-kiloton fiducial mass necessary for rare event searches with sub-centimeter spatial resolution in its ability to image those events, allowing identification of the physics signatures among the numerous backgrounds. In the single-phase liquid argon time-projection chamber (LArTPC) technology, ionization charges drift horizontally in the liquid argon under the influence of an electric field towards a vertical anode, where they are read out with fine granularity. A photon detection system supplements the TPC, directly enhancing physics capabilities for all three DUNE physics drivers and opening up prospects for further physics explorations.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume IV presents an overview of the basic operating principles of a single-phase LArTPC, followed by a description of the DUNE implementation. Each of the subsystems is described in detail, connecting the high-level design requirements and decisions to the overriding physics goals of DUNE.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume III: DUNE Far Detector Technical Coordination
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Exper…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed.
This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-clas…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based.
This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized.
This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large.
△ Less
Submitted 25 March, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume I: Introduction to DUNE
Authors:
B. Abi,
R. Acciarri,
Mario A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
J. Anthony,
M. Antonova,
S. Antusch,
A. Aranda Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (941 additional authors not shown)
Abstract:
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Exper…
▽ More
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. This TDR is intended to justify the technical choices for the far detector that flow down from the high-level physics goals through requirements at all levels of the Project. Volume I contains an executive summary that introduces the DUNE science program, the far detector and the strategy for its modular designs, and the organization and management of the Project. The remainder of Volume I provides more detail on the science program that drives the choice of detector technologies and on the technologies themselves. It also introduces the designs for the DUNE near detector and the DUNE computing model, for which DUNE is planning design reports.
Volume II of this TDR describes DUNE's physics program in detail. Volume III describes the technical coordination required for the far detector design, construction, installation, and integration, and its organizational structure. Volume IV describes the single-phase far detector technology. A planned Volume V will describe the dual-phase technology.
△ Less
Submitted 8 September, 2020; v1 submitted 7 February, 2020;
originally announced February 2020.
-
A new method for an improved anti-neutrino energy reconstruction with charged-current interactions in next-generation detectors
Authors:
L. Munteanu,
S. Suvorov,
S. Dolan,
D. Sgalaberna,
S. Bolognesi,
S. Manly,
G. Yang,
C. Giganti,
K. Iwamoto,
C. Jesús-Valls
Abstract:
We propose and validate a method of anti-neutrino energy reconstruction for charged-current meson-less interactions on composite fully active targets containing hydrogen (such as hydrocarbon scintillator), which is largely free of the poorly understood nuclear effects that usually distort and bias attempts to measure neutrino energy. The method is based on the precise event-by-event measurement of…
▽ More
We propose and validate a method of anti-neutrino energy reconstruction for charged-current meson-less interactions on composite fully active targets containing hydrogen (such as hydrocarbon scintillator), which is largely free of the poorly understood nuclear effects that usually distort and bias attempts to measure neutrino energy. The method is based on the precise event-by-event measurement of the outgoing neutron kinetic energy and the subsequent assessment of the momentum imbalance on the plane transverse to the incoming anti-neutrino direction. For an anti-neutrino flux peaked at around 600 MeV measured using a finely grained $2\times2\times2$ m$^3$ 3D scintillator tracker the neutrino energy resolution is expected to be around 7%, compared to the 15% expected using traditional neutrino energy reconstruction techniques. Analogous results can be obtained for other detectors with similar characteristics.
△ Less
Submitted 3 December, 2019;
originally announced December 2019.
-
Performances of a resistive MicroMegas module for the Time Projection Chambers of the T2K Near Detector upgrade
Authors:
D. Attie,
M. Batkiewicz-Kwasniak,
J. Boix,
S. Bolognesi,
S. Bordoni,
D. Calvet,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
A. Dabrowska,
A. Delbart,
J. Dumarchez,
S. Emery-Schrenk,
C. Giganti,
F. Gramegna,
M. Guigue,
P. Hamacher-Baumann,
F. Iacob,
C. Jesus-Valls,
U. Kosed,
R. Kurjataj,
N. Lacalamita,
M. Lamoureux
, et al. (31 additional authors not shown)
Abstract:
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CE…
▽ More
An upgrade of the Near Detector of the T2K long baseline neutrino oscillation experiment, ND280, has been proposed. This upgrade will include two new Time Projection Chambers, each equipped with 16 resistive MicroMegas modules for gas amplification. A first prototype of resistive MicroMegas has been designed, built, installed in the HARP field cage, and exposed to a beam of charged particles at CERN. The data have been used to characterize the performances of the resistive MicroMegas module. A spatial resolution of 300 $μm$ and a deposited energy resolution of 9% were observed for horizontal electrons crossing the TPCs at 30 cm from the anode. Such performances fully satisfy the requirements for the upgrade of the ND280 TPC.
△ Less
Submitted 9 December, 2019; v1 submitted 16 July, 2019;
originally announced July 2019.
-
T2K ND280 Upgrade -- Technical Design Report
Authors:
K. Abe,
H. Aihara,
A. Ajmi,
C. Andreopoulos,
M. Antonova,
S. Aoki,
Y. Asada,
Y. Ashida,
A. Atherton,
E. Atkin,
D. Attié,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz,
A. Beloshapkin,
V. Berardi,
L. Berns,
S. Bhadra,
J. Bian,
S. Bienstock,
A. Blondel,
J. Boix,
S. Bolognesi
, et al. (359 additional authors not shown)
Abstract:
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve…
▽ More
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve the physics reach of the T2K-II project. This goal is achieved by modifying the upstream part of the detector, adding a new highly granular scintillator detector (Super-FGD), two new TPCs (High-Angle TPC) and six TOF planes. Details about the detector concepts, design and construction methods are presented, as well as a first look at the test-beam data taken in Summer 2018. An update of the physics studies is also presented.
△ Less
Submitted 14 October, 2020; v1 submitted 11 January, 2019;
originally announced January 2019.