Imaging the 511 keV positron annihilation sky with COSI
Authors:
Thomas Siegert,
Steven E. Boggs,
John A. Tomsick,
Andreas Zoglauer,
Carolyn Kierans,
Clio Sleator,
Jacqueline Beechert,
Theresa Brandt,
Pierre Jean,
Hadar Lazar,
Alex Lowell,
Jarred M. Roberts,
Peter von Ballmoos
Abstract:
The balloon-borne Compton Spectrometer and Imager (COSI) had a successful 46-day flight in 2016. The instrument is sensitive to photons in the energy range $0.2$-$5$ MeV. Compton telescopes have the advantage of a unique imaging response and provide the possibility of strong background suppression. With its high-purity germanium detectors, COSI can precisely map $γ$-ray line emission. The stronges…
▽ More
The balloon-borne Compton Spectrometer and Imager (COSI) had a successful 46-day flight in 2016. The instrument is sensitive to photons in the energy range $0.2$-$5$ MeV. Compton telescopes have the advantage of a unique imaging response and provide the possibility of strong background suppression. With its high-purity germanium detectors, COSI can precisely map $γ$-ray line emission. The strongest persistent and diffuse $γ$-ray line signal is the 511 keV emission line from the annihilation of electrons with positrons from the direction of the Galactic centre. While many sources have been proposed to explain the amount of positrons, $\dot{N}_{\mathrm{e^+}} \sim 10^{50}\,\mathrm{e^+\,yr^{-1}}$, the true contributions remain unsolved. In this study, we aim at imaging the 511 keV sky with COSI and pursue a full-forward modelling approach, using a simulated and binned imaging response. For the strong instrumental background, we describe an empirical approach to take the balloon environment into account. We perform two alternative methods to describe the signal: Richardson-Lucy deconvolution, an iterative method towards the maximum likelihood solution, and model fitting with pre-defined emission templates. Consistently with both methods, we find a 511 keV bulge signal with a flux between $0.9$ and $3.1 \times 10^{-3}\,\mathrm{ph\,cm^{-2}\,s^{-1}}$, confirming earlier measurements, and also indications of more extended emission. The upper limit we find for the 511 keV disk, $< 4.3 \times 10^{-3}\,\mathrm{ph\,cm^{-2}\,s^{-1}}$, is consistent with previous detections. For large-scale emission with weak gradients, coded aperture mask instruments suffer from their inability to distinguish isotropic emission from instrumental background, while Compton-telescopes provide a clear imaging response, independent of the true emission.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.
-
Design and characterization of a single photoelectron calibration system for the NectarCAM camera of the medium-sized telescopes of the Cherenkov Telescope Array
Authors:
Barbara Biasuzzi,
Kevin Pressard,
Jonathan Biteau,
Brice Geoffroy,
Carlos Domingues Goncalves,
Giulia Hull,
Miktat Imre,
Michael Josselin,
Alain Maroni,
Bernard Mathon,
Lucien Seminor,
Tiina Suomijarvi,
Thi Nguyen Trung,
Laurent Vatrinet,
Patrick Brun,
Sami Caroff,
Stephen Fegan,
Oscar Ferreira,
Pierre Jean,
Sonia Karkar,
Jean-François Olive,
Stéphane Rivoire,
Patrick Sizun,
Floris Thiant,
Adellain Tsiahina
, et al. (2 additional authors not shown)
Abstract:
In this work, we describe the optical properties of the single photoelectron (SPE) calibration system designed for NectarCAM, a camera proposed for the Medium Sized Telescopes (MST) of the Cherenkov Telescope Array (CTA). One of the goals of the SPE system, as integral part of the NectarCAM camera, consists in measuring with high accuracy the gain of its photo-detection chain. The SPE system is ba…
▽ More
In this work, we describe the optical properties of the single photoelectron (SPE) calibration system designed for NectarCAM, a camera proposed for the Medium Sized Telescopes (MST) of the Cherenkov Telescope Array (CTA). One of the goals of the SPE system, as integral part of the NectarCAM camera, consists in measuring with high accuracy the gain of its photo-detection chain. The SPE system is based on a white painted screen where light pulses are injected through a fishtail light guide from a dedicated flasher. The screen - placed 15 mm away from the focal plane - is mounted on an XY motorization that allows movements over all the camera plane. This allows in-situ measurements of the SPE spectra via a complete scan of the 1855 photo-multiplier tubes (PMTs) of NectarCAM. This calibration process will enable the reduction of the systematic uncertainties on the energy reconstruction of $γ$-rays coming from distant astronomical sources and detected by CTA.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
-
Dual Time Step** Algorithms With the High Order Harmonic Balance Method for Contact Interfaces With Fretting-Wear
Authors:
Loic Salles,
Laurent Blanc,
Alexandre Gouskov,
Pierrick Jean,
Fabrice Thouverez
Abstract:
Contact interfaces with dry friction are frequently used in turbomachinery. Dry friction dam** produced by the sliding surfaces of these interfaces reduces the amplitude of bladed-disk vibration. The relative displacements at these interfaces lead to fretting-wear which reduces the average life expectancy of the structure. Frequency response functions are calculated numerically by using the mult…
▽ More
Contact interfaces with dry friction are frequently used in turbomachinery. Dry friction dam** produced by the sliding surfaces of these interfaces reduces the amplitude of bladed-disk vibration. The relative displacements at these interfaces lead to fretting-wear which reduces the average life expectancy of the structure. Frequency response functions are calculated numerically by using the multi-harmonic balance method (mHBM). The dynamic Lagrangian frequency-time method is used to calculate contact forces in the frequency domain. A new strategy for solving nonlinear systems based on dual time step** is applied. This method is faster than using Newton solvers. It was used successfully for solving Nonlinear CFD equations in the frequency domain. This new approach allows identifying the steady state of worn systems by integrating wear rate equations a on dual time scale. The dual time equations are integrated by an implicit scheme. Of the different orders tested, the first order scheme provided the best results.
△ Less
Submitted 9 April, 2014;
originally announced May 2014.
-
Reflexion Mössbauer analysis of the in situ oxidation products hydroxycarbonate green rust
Authors:
Sebastien Naille,
Mustapha Abdelmoula,
Didier Louber,
Paul Moulin Jean,
Christian Ruby
Abstract:
The purpose of this study is to determine the nature of the oxidation products of FeII-III hydroxycarbonate FeII4FeIII2(OH)12CO3~3H2O (green rust GR(CO32-)) by using the miniaturised Mössbauer spectrometer MIMOS II. Two Mössbauer measurements methods are used: method (i) with green rust pastes coated with glycerol and spread into Plexiglas sample holders, and method (ii) with green rust pastes in…
▽ More
The purpose of this study is to determine the nature of the oxidation products of FeII-III hydroxycarbonate FeII4FeIII2(OH)12CO3~3H2O (green rust GR(CO32-)) by using the miniaturised Mössbauer spectrometer MIMOS II. Two Mössbauer measurements methods are used: method (i) with green rust pastes coated with glycerol and spread into Plexiglas sample holders, and method (ii) with green rust pastes in the same sample holders but introduced into a gas-tight cell with a beryllium window under a continuous nitrogen flow. Method (ii) allows us to follow the continuous deprotonation of GR(CO32-) into the fully ferric deprotonated form FeIII6O4(OH)8CO3~3H2O by adding the correct amount of H2O2, without any further oxidation or degradation of the samples.
△ Less
Submitted 19 October, 2010;
originally announced October 2010.