-
ML-based Calibration and Control of the GlueX Central Drift Chamber
Authors:
Thomas Britton,
Michael Goodrich,
Naomi Jarvis,
Torri Jeske,
Nikhil Kalra,
David Lawrence,
Diana McSpadden,
Kishan Rajput
Abstract:
The GlueX Central Drift Chamber (CDC) in Hall D at Jefferson Lab, used for detecting and tracking charged particles, is calibrated and controlled during data taking using a Gaussian process. The system dynamically adjusts the high voltage applied to the anode wires inside the chamber in response to changing environmental and experimental conditions such that the gain is stabilized. Control policie…
▽ More
The GlueX Central Drift Chamber (CDC) in Hall D at Jefferson Lab, used for detecting and tracking charged particles, is calibrated and controlled during data taking using a Gaussian process. The system dynamically adjusts the high voltage applied to the anode wires inside the chamber in response to changing environmental and experimental conditions such that the gain is stabilized. Control policies have been established to manage the CDC's behavior. These policies are activated when the model's uncertainty exceeds a configurable threshold or during human-initiated tests during normal production running. We demonstrate the system reduces the time detector experts dedicate to calibration of the data offline, leading to a marked decrease in computing resource usage without compromising detector performance.
△ Less
Submitted 3 July, 2024; v1 submitted 5 March, 2024;
originally announced March 2024.
-
AI Assisted Experiment Control and Calibration
Authors:
Thomas Britton,
Michael Goodrich,
Naomi Jarvis,
Torri Jeske,
Nikhil Kalra,
David Lawrence,
Diana McSpadden
Abstract:
Final report for the AI Assisted Experiment Control and Calibration project. This project integrated AI/ML into the controls and calibration of a production detector system in the GlueX spectrometer, a large scale Nuclear Physics detector in experimental Hall-D at Jefferson Lab. The AI/ML model predicted calibration constants for a Central Drift Chamber using environmental information available pr…
▽ More
Final report for the AI Assisted Experiment Control and Calibration project. This project integrated AI/ML into the controls and calibration of a production detector system in the GlueX spectrometer, a large scale Nuclear Physics detector in experimental Hall-D at Jefferson Lab. The AI/ML model predicted calibration constants for a Central Drift Chamber using environmental information available prior to taking the data. The device controls were then automatically adjusted so that the calibration values needed for post-processing of the data were much more stable and quicker to determine. Integration into a production system required guardrails and policy choices to ensure safety of the equipment and the data quality. The project sought to apply similar technology to other detectors. Those efforts are also described here. This documents many of the details of the project.
△ Less
Submitted 7 February, 2024;
originally announced February 2024.
-
AI for Experimental Controls at Jefferson Lab
Authors:
Torri Jeske,
Diana McSpadden,
Nikhil Kalra,
Thomas Britton,
Naomi Jarvis,
David Lawrence
Abstract:
The AI for Experimental Controls project is develo** an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Ch…
▽ More
The AI for Experimental Controls project is develo** an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a Sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
The Central Drift Chamber for GlueX
Authors:
N. S. Jarvis,
C. A. Meyer,
B. Zihlmann,
M. Staib,
A. Austregesilo,
F. Barbosa,
C. Dickover,
V. Razmyslovich,
S. Taylor,
Y. Van Haarlem,
G. Visser,
T. Whitlatch
Abstract:
The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as 0.25 GeV/c as well as to identify low-momentum protons via energy loss. The construction of the detector is described and its operation and calibration are discu…
▽ More
The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as 0.25 GeV/c as well as to identify low-momentum protons via energy loss. The construction of the detector is described and its operation and calibration are discussed in detail. The design goal of 150 microns in position resolution has been reached.
△ Less
Submitted 27 February, 2020; v1 submitted 16 October, 2019;
originally announced October 2019.
-
Characteristics of unconventional Rb magneto-optical traps
Authors:
K. N. Jarvis,
B. E. Sauer,
M. R. Tarbutt
Abstract:
We study several new magneto-optical trap** configurations in $^{87}$Rb. These unconventional MOTs all use type-II transitions, where the angular momentum of the ground state is greater than or equal to that of the excited state, and they may use either red-detuned or blue-detuned light. We describe the conditions under which each new MOT forms. The various MOTs exhibit an enormous range of life…
▽ More
We study several new magneto-optical trap** configurations in $^{87}$Rb. These unconventional MOTs all use type-II transitions, where the angular momentum of the ground state is greater than or equal to that of the excited state, and they may use either red-detuned or blue-detuned light. We describe the conditions under which each new MOT forms. The various MOTs exhibit an enormous range of lifetimes, temperatures and density distributions. At the detunings where they are maximized, the lifetimes of the various MOTs vary from 0.1 to 15 s. One MOT forms large ring-like structures with no density at the centre. The temperature in the red-detuned MOTs can be three orders of magnitude higher than in the blue-detuned MOTs. We present measurements of the capture velocity of a blue-detuned MOT, and we study how the loss rate due to ultracold collisions depends on laser intensity and detuning.
△ Less
Submitted 19 July, 2018;
originally announced July 2018.
-
Blue-detuned magneto-optical trap
Authors:
K. N. Jarvis,
J. A. Devlin,
T. E. Wall,
B. E. Sauer,
M. R. Tarbutt
Abstract:
We present the properties and advantages of a new magneto-optical trap (MOT) where blue-detuned light drives `type-II' transitions that have dark ground states. Using $^{87}$Rb, we reach a radiation-pressure-limited density exceeding $10^{11}$cm$^{-3}$ and a temperature below 30$μ$K. The phase-space density is higher than in normal atomic MOTs, and a million times higher than comparable red-detune…
▽ More
We present the properties and advantages of a new magneto-optical trap (MOT) where blue-detuned light drives `type-II' transitions that have dark ground states. Using $^{87}$Rb, we reach a radiation-pressure-limited density exceeding $10^{11}$cm$^{-3}$ and a temperature below 30$μ$K. The phase-space density is higher than in normal atomic MOTs, and a million times higher than comparable red-detuned type-II MOTs, making it particularly attractive for molecular MOTs which rely on type-II transitions. The loss of atoms from the trap is dominated by ultracold collisions between Rb atoms. For typical trap** conditions, we measure a loss rate of $1.8(4)\times10^{-10}$cm$^{3}$s$^{-1}$.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
First Results from The GlueX Experiment
Authors:
The GlueX Collaboration,
H. Al Ghoul,
E. G. Anassontzis,
F. Barbosa,
A. Barnes,
T. D. Beattie,
D. W. Bennett,
V. V. Berdnikov,
T. Black,
W. Boeglin,
W. K. Brooks,
B. Cannon,
O. Chernyshov,
E. Chudakov,
V. Crede,
M. M. Dalton,
A. Deur,
S. Dobbs,
A. Dolgolenko,
M. Dugger,
H. Egiyan,
P. Eugenio,
A. M. Foda,
J. Frye,
S. Furletov
, et al. (86 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and…
▽ More
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and $ω$ mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the $ρ$ has been observed.
△ Less
Submitted 14 January, 2016; v1 submitted 11 December, 2015;
originally announced December 2015.
-
A study of decays to strange final states with GlueX in Hall D using components of the BaBar DIRC
Authors:
The GlueX Collaboration,
M. Dugger,
B. Ritchie,
I. Senderovich,
E. Anassontzis,
P. Ioannou,
C. Kourkoumeli,
G. Vasileiadis,
G. Voulgaris,
N. Jarvis,
W. Levine,
P. Mattione,
W. McGinley,
C. A. Meyer,
R. Schumacher,
M. Staib,
F. Klein,
D. Sober,
N. Sparks,
N. Walford,
D. Doughty,
A. Barnes,
R. Jones,
J. McIntyre,
F. Mokaya
, et al. (82 additional authors not shown)
Abstract:
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studi…
▽ More
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studies of kaon final states are essential for inferring the quark flavor content of hybrid and conventional mesons. The GlueX FDIRC would reuse one-third of the synthetic fused silica bars that were utilized in the BaBar DIRC. A new focussing photon camera, read out with large area photodetectors, would be developed. We propose operating the enhanced GlueX detector in Hall D for a total of 220 days at an average intensity of 5x10^7 γ/s, a program that was conditionally approved by PAC39
△ Less
Submitted 1 August, 2014;
originally announced August 2014.