-
Fully three-dimensional sound speed-corrected multi-wavelength photoacoustic breast tomography
Authors:
M. Dantuma,
F. Lucka,
S. C. Kruitwagen,
A. Javaherian,
L. Alink,
R. P. Pompe van Meerdervoort,
M. Nanninga,
T. J. P. M. Op 't Root,
B. De Santi,
J. Budisky,
G. Bordovsky,
E. Coffy,
M. Wilm,
T. Kasponas,
S. H. Aarnink,
L. F. de Geus-Oei,
F. Brochin,
T. Martinez,
A. Michailovas,
W. Muller Kobold,
J. Jaros,
J. Veltman,
B. Cox,
S. Manohar
Abstract:
Photoacoustic tomography is a contrast agent-free imaging technique capable of visualizing blood vessels and tumor-associated vascularization in breast tissue. While sophisticated breast imaging systems have been recently developed, there is yet much to be gained in imaging depth, image quality and tissue characterization capability before clinical translation is possible. In response, we have dev…
▽ More
Photoacoustic tomography is a contrast agent-free imaging technique capable of visualizing blood vessels and tumor-associated vascularization in breast tissue. While sophisticated breast imaging systems have been recently developed, there is yet much to be gained in imaging depth, image quality and tissue characterization capability before clinical translation is possible. In response, we have developed a hybrid photoacoustic and ultrasound-transmission tomographic system PAM3. The photoacoustic component has for the first time three-dimensional multi-wavelength imaging capability, and implements substantial technical advancements in critical hardware and software sub-systems. The ultrasound component enables for the first time, a three-dimensional sound speed map of the breast to be incorporated in photoacoustic reconstruction to correct for inhomogeneities, enabling accurate target recovery. The results demonstrate the deepest photoacoustic breast imaging to date namely 48 mm, with a more uniform field of view than hitherto, and an isotropic spatial resolution that rivals that of Magnetic Resonance Imaging. The in vivo performance achieved, and the diagnostic value of interrogating angiogenesis-driven optical contrast as well as tumor mass sound speed contrast, gives confidence in the system's clinical potential.
△ Less
Submitted 13 August, 2023;
originally announced August 2023.
-
Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models
Authors:
Jean-Francois Aubry,
Oscar Bates,
Christian Boehm,
Kim Butts Pauly,
Douglas Christensen,
Carlos Cueto,
Pierre Gelat,
Lluis Guasch,
Jiri Jaros,
Yun **g,
Rebecca Jones,
Ningrui Li,
Patrick Marty,
Hazael Montanaro,
Esra Neufeld,
Samuel Pichardo,
Gianmarco Pinton,
Aki Pulkkinen,
Antonio Stanziola,
Axel Thielscher,
Bradley Treeby,
Elwin van 't Wout
Abstract:
Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numeric…
▽ More
Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numerical benchmarks. Here, these benchmarks are presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexity are defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull. Two transducer configurations are considered (a focused bowl and a plane piston), giving a total of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmark results. The models span a wide range of numerical techniques, including the finite-difference time-domain method, angular-spectrum method, pseudospectral method, boundary-element method, and spectral-element method. Good agreement is found between the models, particularly for the position, size, and magnitude of the acoustic focus within the skull. When comparing results for each model with every other model in a cross comparison, the median values for each benchmark for the difference in focal pressure and position are less than 10\% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freely available to facilitate further comparisons.
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
Pseudospectral time-domain (PSTD) methods for the wave equation: Realising boundary conditions with discrete sine and cosine transforms
Authors:
E. S. Wise,
J. Jaros,
B. T. Cox,
B. E. Treeby
Abstract:
Pseudospectral time domain (PSTD) methods are widely used in many branches of acoustics for the numerical solution of the wave equation, including biomedical ultrasound and seismology. The use of the Fourier collocation spectral method in particular has many computational advantages. However, the use of a discrete Fourier basis is also inherently restricted to solving problems with periodic bounda…
▽ More
Pseudospectral time domain (PSTD) methods are widely used in many branches of acoustics for the numerical solution of the wave equation, including biomedical ultrasound and seismology. The use of the Fourier collocation spectral method in particular has many computational advantages. However, the use of a discrete Fourier basis is also inherently restricted to solving problems with periodic boundary conditions. Here, a family of spectral collocation methods based on the use of a sine or cosine basis is described. These retain the computational advantages of the Fourier collocation method but instead allow homogeneous Dirichlet (sound-soft) and Neumann (sound-hard) boundary conditions to be imposed. The basis function weights are computed numerically using the discrete sine and cosine transforms, which can be implemented using O(N log N) operations analogous to the fast Fourier transform. Practical details of how to implement spectral methods using discrete sine and cosine transforms are provided. The technique is then illustrated through the solution of the wave equation in a rectangular domain subject to different combinations of boundary conditions. The extension to boundaries with arbitrary real reflection coefficients or boundaries that are non-reflecting is also demonstrated using the weighted summation of the solutions with Dirichlet and Neumann boundary conditions.
△ Less
Submitted 2 December, 2020; v1 submitted 1 May, 2020;
originally announced May 2020.
-
Transurethral ultrasound therapy of the prostate in the presence of calcifications: A simulation study
Authors:
Visa Suomi,
Bradley Treeby,
Jiri Jaros,
Pietari Makela,
Mikael Anttinen,
Jani Saunavaara,
Teija Sainio,
Aida Kiviniemi,
Roberto Blanco
Abstract:
Purpose: Transurethral ultrasound therapy is an investigational treatment modality which could potentially be used for the localized treatment of prostate cancer. One of the limiting factors of this therapy is prostatic calcifications. These attenuate and reflect ultrasound and thus reduce the efficacy of the heating. The aim of this study is to investigate how prostatic calcifications affect ther…
▽ More
Purpose: Transurethral ultrasound therapy is an investigational treatment modality which could potentially be used for the localized treatment of prostate cancer. One of the limiting factors of this therapy is prostatic calcifications. These attenuate and reflect ultrasound and thus reduce the efficacy of the heating. The aim of this study is to investigate how prostatic calcifications affect therapeutic efficacy, and to identify the best sonication strategy when calcifications are present. Methods: Realistic computational models were used on clinical patient data in order to simulate different therapeutic situations with naturally occurring calcifications as well as artificial calcifications of different sizes (1-10 mm) and distances (5-15 mm). Furthermore, different sonication strategies were tested in order to deliver therapy to the untreated tissue regions behind the calcifications. Results: The presence of calcifications in front of the ultrasound field was found to increase the peak pressure by 100% on average while the maximum temperature only rose by 9% during a 20-s sonication. Losses in ultrasound energy were due to the relatively large acoustic impedance mismatch between the prostate tissue and the calcifications (1.63 vs 3.20 MRayl) and high attenuation coefficient (0.78 vs 2.64 dB/MHz^1.1/cm), which together left untreated tissue regions behind the calcifications. In addition, elevated temperatures were seen in the region between the transducer and the calcifications. Lower sonication frequencies (1-4 MHz) were not able to penetrate through the calcifications effectively, but longer sonication durations (20-60 s) with selective transducer elements were effective in treating the tissue regions behind the calcifications.
△ Less
Submitted 29 September, 2019;
originally announced September 2019.
-
The effect of tissue physiological variability on transurethral ultrasound therapy of the prostate
Authors:
Visa Suomi,
Bradley Treeby,
Jiri Jaros,
Jani Saunavaara,
Aida Kiviniemi,
Roberto Blanco
Abstract:
Therapeutic ultrasound is an investigational modality which could potentially be used for minimally invasive treatment of prostate cancer. Computational simulations were used to study the effect of natural physiological variations in tissue parameters on the efficacy of therapeutic ultrasound treatment in the prostate. The simulations were conducted on a clinical ultrasound therapy system using pa…
▽ More
Therapeutic ultrasound is an investigational modality which could potentially be used for minimally invasive treatment of prostate cancer. Computational simulations were used to study the effect of natural physiological variations in tissue parameters on the efficacy of therapeutic ultrasound treatment in the prostate. The simulations were conducted on a clinical ultrasound therapy system using patient computed tomography (CT) data. The values of attenuation, perfusion, specific heat capacity and thermal conductivity were changed within their biological ranges to determine their effect on peak temperature and thermal dose volume. Increased attenuation was found to have the biggest effect on peak temperature with a 6.9% rise. The smallest effect was seen with perfusion with +-0.2% variation in peak temperature. Thermal dose was mostly affected by specific heat capacity which showed a 20.7% increase in volume with reduced heat capacity. Thermal conductivity had the smallest effect on thermal dose with up to 2.1% increase in the volume with reduced thermal conductivity. These results can be used to estimate the interpatient variation during the therapeutic ultrasound treatment of the prostate.
△ Less
Submitted 7 November, 2018;
originally announced November 2018.
-
Light Dark Matter eXperiment (LDMX)
Authors:
Torsten Åkesson,
Asher Berlin,
Nikita Blinov,
Owen Colegrove,
Giulia Collura,
Valentina Dutta,
Bertrand Echenard,
Joshua Hiltbrand,
David G. Hitlin,
Joseph Incandela,
John Jaros,
Robert Johnson,
Gordan Krnjaic,
Jeremiah Mans,
Takashi Maruyama,
Jeremy McCormick,
Omar Moreno,
Timothy Nelson,
Gavin Niendorf,
Reese Petersen,
Ruth Pöttgen,
Philip Schuster,
Natalia Toro,
Nhan Tran,
Andrew Whitbeck
Abstract:
We present an initial design study for LDMX, the Light Dark Matter Experiment, a small-scale accelerator experiment having broad sensitivity to both direct dark matter and mediator particle production in the sub-GeV mass region. LDMX employs missing momentum and energy techniques in multi-GeV electro-nuclear fixed-target collisions to explore couplings to electrons in uncharted regions that extend…
▽ More
We present an initial design study for LDMX, the Light Dark Matter Experiment, a small-scale accelerator experiment having broad sensitivity to both direct dark matter and mediator particle production in the sub-GeV mass region. LDMX employs missing momentum and energy techniques in multi-GeV electro-nuclear fixed-target collisions to explore couplings to electrons in uncharted regions that extend down to and below levels that are motivated by direct thermal freeze-out mechanisms. LDMX would also be sensitive to a wide range of visibly and invisibly decaying dark sector particles, thereby addressing many of the science drivers highlighted in the 2017 US Cosmic Visions New Ideas in Dark Matter Community Report. LDMX would achieve the required sensitivity by leveraging existing and develo** detector technologies from the CMS, HPS and Mu2e experiments. In this paper, we present our initial design concept, detailed GEANT-based studies of detector performance, signal and background processes, and a preliminary analysis approach. We demonstrate how a first phase of LDMX could expand sensitivity to a variety of light dark matter, mediator, and millicharge particles by several orders of magnitude in coupling over the broad sub-GeV mass range.
△ Less
Submitted 15 August, 2018;
originally announced August 2018.
-
Full modelling of high-intensity focused ultrasound and thermal heating in the kidney using realistic patient models
Authors:
Visa Suomi,
Jiri Jaros,
Bradley Treeby,
Robin Cleveland
Abstract:
Objective: High-intensity focused ultrasound (HIFU) therapy can be used for non-invasive treatment of kidney (renal) cancer, but the clinical outcomes have been variable. In this study, the efficacy of renal HIFU therapy was studied using nonlinear acoustic and thermal simulations in three patients. Methods: The acoustic simulations were conducted with and without refraction in order to investigat…
▽ More
Objective: High-intensity focused ultrasound (HIFU) therapy can be used for non-invasive treatment of kidney (renal) cancer, but the clinical outcomes have been variable. In this study, the efficacy of renal HIFU therapy was studied using nonlinear acoustic and thermal simulations in three patients. Methods: The acoustic simulations were conducted with and without refraction in order to investigate its effect on the shape, size and pressure distribution at the focus. The values for the attenuation, sound speed, perfusion and thermal conductivity of the kidney were varied over the reported ranges to determine the effect of variability on heating. Furthermore, the phase aberration was studied in order to quantify the underlying phase shifts using a second order polynomial function. Results: The ultrasound field intensity was found to drop on average 11.1 dB with refraction and 6.4 dB without refraction. Reflection at tissue interfaces was found to result in a loss less than 0.1 dB. Focal point splitting due to refraction significantly reduced the heating efficacy. Perfusion did not have a large effect on heating during short sonication durations. Small changes in temperature were seen with varying attenuation and thermal conductivity, but no visible changes were present with sound speed variations. The aberration study revealed an underlying trend in the spatial distribution of the phase shifts. Conclusion: The results show that the efficacy of HIFU therapy in the kidney could be improved with aberration correction. Significance: A method is proposed by which patient specific pre-treatment calculations could be used to overcome the aberration and therefore make ultrasound treatment possible.
△ Less
Submitted 8 October, 2018; v1 submitted 9 August, 2017;
originally announced August 2017.
-
The Heavy Photon Search beamline and its performance
Authors:
N. Baltzell,
H. Egiyan,
M. Ehrhart,
C. Field,
A. Freyberger,
F. -X. Girod,
M. Holtrop,
J. Jaros,
G. Kalicy,
T. Maruyama,
B. McKinnon,
K. Moffeit,
T. Nelson,
A. Odian,
M. Oriunno,
R. Paremuzyan,
S. Stepanyan,
M. Tiefenback,
S. Uemura,
M. Ungaro,
H. Vance
Abstract:
The Heavy Photon Search (HPS) is an experiment to search for a hidden sector photon, aka a heavy photon or dark photon, in fixed target electroproduction at the Thomas Jefferson National Accelerator Facility (JLab). The HPS experiment searches for the e$^+$e$^-$ decay of the heavy photon with bump hunt and detached vertex strategies using a compact, large acceptance forward spectrometer, consistin…
▽ More
The Heavy Photon Search (HPS) is an experiment to search for a hidden sector photon, aka a heavy photon or dark photon, in fixed target electroproduction at the Thomas Jefferson National Accelerator Facility (JLab). The HPS experiment searches for the e$^+$e$^-$ decay of the heavy photon with bump hunt and detached vertex strategies using a compact, large acceptance forward spectrometer, consisting of a silicon microstrip detector (SVT) for tracking and vertexing, and a PbWO$_4$ electromagnetic calorimeter for energy measurement and fast triggering. To achieve large acceptance and good vertexing resolution, the first layer of silicon detectors is placed just 10 cm downstream of the target with the sensor edges only 500 $μ$m above and below the beam. Placing the SVT in such close proximity to the beam puts stringent requirements on the beam profile and beam position stability. As part of an approved engineering run, HPS took data in 2015 and 2016 at 1.05 GeV and 2.3 GeV beam energies, respectively. This paper describes the beam line and its performance during that data taking.
△ Less
Submitted 22 December, 2016;
originally announced December 2016.
-
Nonlinear 3-D simulation of high-intensity focused ultrasound therapy in the kidney
Authors:
Visa Suomi,
Jiri Jaros,
Bradley Treeby,
Robin Cleveland
Abstract:
Kidney cancer is a severe disease which can be treated non-invasively using high-intensity focused ultrasound (HIFU) therapy. However, tissue in front of the transducer and the deep location of kidney can cause significant losses to the efficiency of the treatment. The effect of attenuation, refraction and reflection due to different tissue types on HIFU therapy of the kidney was studied using a n…
▽ More
Kidney cancer is a severe disease which can be treated non-invasively using high-intensity focused ultrasound (HIFU) therapy. However, tissue in front of the transducer and the deep location of kidney can cause significant losses to the efficiency of the treatment. The effect of attenuation, refraction and reflection due to different tissue types on HIFU therapy of the kidney was studied using a nonlinear ultrasound simulation model. The geometry of the tissue was derived from a computed tomography (CT) dataset of a patient which had been segmented for water, bone, soft tissue, fat and kidney. The combined effect of inhomogeneous attenuation and sound-speed was found to result in an 11.0 dB drop in spatial peak-temporal average (SPTA) intensity in the kidney compared to pure water. The simulation without refraction effects showed a 6.3 dB decrease indicating that both attenuation and refraction contribute to the loss in focal intensity. The losses due to reflections at soft tissue interfaces were less than 0.1 dB. Focal point shifting due to refraction effects resulted in -1.3, 2.6 and 1.3 mm displacements in x-, y- and z-directions respectively. Furthermore, focal point splitting into several smaller subvolumes was observed. The total volume of the secondary focal points was approximately 46% of the largest primary focal point. This could potentially lead to undesired heating outside the target location and longer therapy times.
△ Less
Submitted 31 August, 2016;
originally announced August 2016.
-
Full-wave nonlinear ultrasound simulation on distributed clusters with applications in high-intensity focused ultrasound
Authors:
Jiri Jaros,
Alistair P. Rendell,
Bradley E. Treeby
Abstract:
Model-based treatment planning and exposimetry for high-intensity focused ultrasound (HIFU) requires the numerical simulation of nonlinear ultrasound propagation through heterogeneous and absorbing media. This is a computationally demanding problem due to the large distances travelled by the ultrasound waves relative to the wavelength of the highest frequency harmonic. Here, the k-space pseudospec…
▽ More
Model-based treatment planning and exposimetry for high-intensity focused ultrasound (HIFU) requires the numerical simulation of nonlinear ultrasound propagation through heterogeneous and absorbing media. This is a computationally demanding problem due to the large distances travelled by the ultrasound waves relative to the wavelength of the highest frequency harmonic. Here, the k-space pseudospectral method is used to solve a set of coupled partial differential equations equivalent to a generalised Westervelt equation. The model is implemented in C++ and parallelised using the message passing interface (MPI) for solving large-scale problems on distributed clusters. The domain is partitioned using a 1D slab decomposition, and global communication is performed using a sparse communication pattern. Operations in the spatial frequency domain are performed in transposed space to reduce the communication burden imposed by the 3D fast Fourier transform. The performance of the model is evaluated using grid sizes up to 4096 x 2048 x 2048 grid points distributed over a cluster using up to 1024 compute cores. Given the global nature of the gradient calculation, the model shows good strong scaling behaviour, with a speed-up of 1.7x whenever the number of cores is doubled. This means large-scale simulations can be distributed across high numbers of cores on a cluster to minimise execution times with a relatively small computational overhead. The efficacy of the model is demonstrated by simulating the ultrasound beam pattern for a HIFU sonication of the kidney.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
The Heavy Photon Search Test Detector
Authors:
Marco Battaglieri,
Sergey Boyarinov,
Stephen Bueltmann,
Volker Burkert,
Andrea Celentano,
Gabriel Charles,
William Cooper,
Chris Cuevas,
Natalia Dashyan,
Raffaella DeVita,
Camille Desnault,
Alexandre Deur,
Hovanes Egiyan,
Latifa Elouadrhiri,
Rouven Essig,
Vitaliy Fadeyev,
Clive Field,
Arne Freyberger,
Yuri Gershtein,
Nerses Gevorgyan,
Francois-Xavier Girod,
Norman Graf,
Mathew Graham,
Keith Griffioen,
Alexander Grillo
, et al. (39 additional authors not shown)
Abstract:
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm th…
▽ More
The Heavy Photon Search (HPS), an experiment to search for a hidden sector photon in fixed target electroproduction, is preparing for installation at the Thomas Jefferson National Accelerator Facility (JLab) in the Fall of 2014. As the first stage of this project, the HPS Test Run apparatus was constructed and operated in 2012 to demonstrate the experiment's technical feasibility and to confirm that the trigger rates and occupancies are as expected. This paper describes the HPS Test Run apparatus and readout electronics and its performance. In this setting, a heavy photon can be identified as a narrow peak in the e$^+$e$^-$ invariant mass spectrum, above the trident background or as a narrow invariant mass peak with a decay vertex displaced from the production target, so charged particle tracking and vertexing are needed for its detection. In the HPS Test Run, charged particles are measured with a compact forward silicon microstrip tracker inside a dipole magnet. Electromagnetic showers are detected in a PbW0$_{4}$ crystal calorimeter situated behind the magnet, and are used to trigger the experiment and identify electrons and positrons. Both detectors are placed close to the beam line and split top-bottom. This arrangement provides sensitivity to low-mass heavy photons, allows clear passage of the unscattered beam, and avoids the spray of degraded electrons coming from the target. The discrimination between prompt and displaced e$^+$e$^-$ pairs requires the first layer of silicon sensors be placed only 10~cm downstream of the target. The expected signal is small, and the trident background huge, so the experiment requires very large statistics. Accordingly, the HPS Test Run utilizes high-rate readout and data acquisition electronics and a fast trigger to exploit the essentially 100% duty cycle of the CEBAF accelerator at JLab.
△ Less
Submitted 4 June, 2015; v1 submitted 23 June, 2014;
originally announced June 2014.
-
ILC Reference Design Report Volume 4 - Detectors
Authors:
Ties Behnke,
Chris Damerell,
John Jaros,
Akya Myamoto
Abstract:
This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise th…
▽ More
This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.
△ Less
Submitted 14 December, 2007;
originally announced December 2007.