A 25-micron single photon sensitive kinetic inductance detector
Authors:
Peter K. Day,
Nicholas F. Cothard,
Christopher Albert,
Logan Foote,
Elijah Kane,
Byeong H. Eom,
Ritoban Basu Thakur,
Reinier M. J. Janssen,
Andrew Beyer,
Pierre Echternach,
Sven van Berkel,
Steven Hailey-Dunsheath,
Thomas R. Stevenson,
Shahab Dabironezare,
Jochem J. A. Baselmans,
Jason Glenn,
C. Matt Bradford,
Henry G. Leduc
Abstract:
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integ…
▽ More
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
△ Less
Submitted 14 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
High-sensitivity Kinetic Inductance Detector Arrays for the Probe Far-Infrared Mission for Astrophysics
Authors:
Logan Foote,
Chris Albert,
Jochem Baselmans,
Andrew Beyer,
Nicholas Cothard,
Peter Day,
Steven Hailey-Dunsheath,
Pierre Echternach,
Reinier Janssen,
Elijah Kane,
Henry Leduc,
Lun-Jun Liu,
Hien Nguyen,
Joanna Perido,
Jason Glenn,
Jonas Zmuidzinas,
Charles,
Bradford
Abstract:
Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe far-Infrared Mission for Astrophysics (PRIMA), which is currently under study, emphasizes low and moderate resolution spectroscopy throughout the far-IR. Full utili…
▽ More
Far-infrared (far-IR) astrophysics missions featuring actively cooled telescopes will offer orders of magnitude observing speed improvement at wavelengths where galaxies and forming planetary systems emit most of their light. The PRobe far-Infrared Mission for Astrophysics (PRIMA), which is currently under study, emphasizes low and moderate resolution spectroscopy throughout the far-IR. Full utilization of PRIMA's cold telescope requires far-IR detector arrays with per-pixel noise equivalent powers (NEPs) at or below 1 x 10-19 W/rtHz. We are develo** low-volume Aluminum kinetic inductance detector (KID) arrays to reach these sensitivities. We will present on the development of our long-wavelength (210 um) array approach, with a focus on multitone measurements of our 1,008-pixel arrays. We measure an NEP below 1 x 10-19 W/rtHz for 73 percent of our pixels.
△ Less
Submitted 29 May, 2024; v1 submitted 3 November, 2023;
originally announced November 2023.
-
Design of The Kinetic Inductance Detector Based Focal Plane Assembly for The Terahertz Intensity Mapper
Authors:
L. -J. Liu,
R. M. J. Janssen,
C. M. Bradford,
S. Hailey-Dunsheath,
J. Fu,
J. P. Filippini,
J. E. Aguirre,
J. S. Bracks,
A. J. Corso,
C. Groppi,
J. Hoh,
R. P. Keenan,
I. N. Lowe,
D. P. Marrone,
P. Mauskopf,
R. Nie,
J. Redford,
I. Trumper,
J. D. Vieira
Abstract:
We report on the kinetic inductance detector (KID) array focal plane assembly design for the Terahertz Intensity Mapper (TIM). Each of the 2 arrays consists of 4 wafer-sized dies (quadrants), and the overall assembly must satisfy thermal and mechanical requirements, while maintaining high optical efficiency and a suitable electromagnetic environment for the KIDs. In particular, our design manages…
▽ More
We report on the kinetic inductance detector (KID) array focal plane assembly design for the Terahertz Intensity Mapper (TIM). Each of the 2 arrays consists of 4 wafer-sized dies (quadrants), and the overall assembly must satisfy thermal and mechanical requirements, while maintaining high optical efficiency and a suitable electromagnetic environment for the KIDs. In particular, our design manages to strictly maintain a 50 $\mathrm{μm}$ air gap between the array and the horn block. We have prototyped and are now testing a sub-scale assembly which houses a single quadrant for characterization before integration into the full array. The initial test result shows a $>$95\% yield, indicating a good performance of our TIM detector packaging design.
△ Less
Submitted 17 November, 2022;
originally announced November 2022.
-
Design and testing of Kinetic Inductance Detector package for the Terahertz Intensity Mapper
Authors:
L. -J. Liu,
R. M. J Janssen,
C. M. Bradford,
S. Hailey-Dunsheath,
J. P. Filippini,
J. E. Aguirre,
J. S. Bracks,
A. J. Corso,
J. Fu,
C. Groppi,
J. Hoh,
R. P. Keenan,
I. N. Lowe,
D. P. Marrone,
P. Mauskopf,
R. Nie,
J. Redford,
I. Trumper,
J. D. Vieira
Abstract:
The Terahertz Intensity Mapper (TIM) is designed to probe the star formation history in dust-obscured star-forming galaxies around the peak of cosmic star formation. This will be done via measurements of the redshifted 157.7 um line of singly ionized carbon ([CII]). TIM employs two R $\sim 250$ long-slit grating spectrometers covering 240-420 um. Each is equipped with a focal plane unit containing…
▽ More
The Terahertz Intensity Mapper (TIM) is designed to probe the star formation history in dust-obscured star-forming galaxies around the peak of cosmic star formation. This will be done via measurements of the redshifted 157.7 um line of singly ionized carbon ([CII]). TIM employs two R $\sim 250$ long-slit grating spectrometers covering 240-420 um. Each is equipped with a focal plane unit containing 4 wafer-sized subarrays of horn-coupled aluminum kinetic inductance detectors (KIDs). We present the design and performance of a prototype focal plane assembly for one of TIM's KID-based subarrays. Our design strictly maintain high optical efficiency and a suitable electromagnetic environment for the KIDs. The prototype detector housing in combination with the first flight-like quadrant are tested at 250 mK. Initial frequency scan shows that many resonances are affected by collisions and/or very shallow transmission dips as a result of a degraded internal quality factor (Q factor). This is attributed to the presence of an external magnetic field during cooldown. We report on a study of magnetic field dependence of the Q factor of our quadrant array. We implement a Helmholtz coil to vary the magnetic field at the detectors by (partially) nulling earth's. Our investigation shows that the earth magnetic field can significantly affect our KIDs' performance by degrading the Q factor by a factor of 2-5, well below those expected from the operational temperature or optical loading. We find that we can sufficiently recover our detectors' quality factor by tuning the current in the coils to generate a field that matches earth's magnetic field in magnitude to within a few uT. Therefore, it is necessary to employ a properly designed magnetic shield enclosing the TIM focal plane unit. Based on the results presented in this paper, we set a shielding requirement of |B| < 3 uT.
△ Less
Submitted 16 November, 2022;
originally announced November 2022.
-
Impact of Signalized Intersections on $CO_2$ and $NO_x$ Emissions of Heavy Duty Vehicles
Authors:
Nicolás Deschle,
Ernst Jan van Ark,
René van Gijlswijk,
Robbert Janssen
Abstract:
Pollutant emissions have been a topic of interest in the last decades. Not only environmentalists but also governments are taking rapid action to reduce emissions. As one of the main contributors, the transport sector is being subjected to strict scrutiny to ensure it complies with the short and long-term regulations. The measures imposed by the governments clearly involve, all the stakeholders in…
▽ More
Pollutant emissions have been a topic of interest in the last decades. Not only environmentalists but also governments are taking rapid action to reduce emissions. As one of the main contributors, the transport sector is being subjected to strict scrutiny to ensure it complies with the short and long-term regulations. The measures imposed by the governments clearly involve, all the stakeholders in the logistics sector, from road authorities and logistic operators to truck manufacturers. Improvement of traffic conditions is one of the perspectives in which the reduction of emissions is being addressed. Optimization of traffic flow, avoidance of unnecessary stops, control of the cruise speed, and coordination of trips in an energy-efficient way are necessary steps to remain compliant with the upcoming regulations. In this study, we have measured the $CO_2$ and $NO_x$ emissions in heavy-duty vehicles while traversing signalized intersections and we examined the differences between various scenarios. We found that avoiding a stop can reduce $CO_2$ and $NO_x$ emissions on 0.32 kg and 1.8 g, respectively. These results put traffic control in the main scene as a yet unexplored dimension to control pollutant emissions, enabling the authorities to more accurately estimate cost-benefit plans for traffic control system investments.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
Photon-momentum-induced molecular dynamics in photoionization of N$_2$ at $hν=40$ keV
Authors:
M. Kircher,
J. Rist,
F. Trinter,
S. Grundmann,
M. Waitz,
N. Melzer,
I. Vela-Perez,
T. Mletzko,
A. Pier,
N. Strenger,
J. Siebert,
R. Janssen,
V. Honkimäki,
J. Drnec,
Ph. V. Demekhin,
L. Ph. H. Schmidt,
M. S. Schöffler,
T. Jahnke,
R. Dörner
Abstract:
We investigate K-shell ionization of N$_2$ at 40 keV photon energy. Using a COLTRIMS reaction microscope we determine the vector momenta of the photoelectron, the Auger electron and both N$^+$ fragments. These fully differential data show that the dissociation process of the N$_2^{2+}$ ion is significantly modified not only by the recoil momentum of the photoelectron, but also by the photon moment…
▽ More
We investigate K-shell ionization of N$_2$ at 40 keV photon energy. Using a COLTRIMS reaction microscope we determine the vector momenta of the photoelectron, the Auger electron and both N$^+$ fragments. These fully differential data show that the dissociation process of the N$_2^{2+}$ ion is significantly modified not only by the recoil momentum of the photoelectron, but also by the photon momentum and the momentum of the emitted Auger electron. We find that the recoil energy introduced by the photon and the photoelectron momentum is partitioned with a ratio of approximately 30/70 between the Auger electron and fragment ion kinetic energies, respectively. We also observe that the photon momentum induces an additional rotation of the molecular ion.
△ Less
Submitted 5 May, 2021;
originally announced May 2021.
-
Recoil-Induced Asymmetry of Nondipole Molecular Frame Photoelectron Angular Distributions in the Hard X-ray Regime
Authors:
M. Kircher,
J. Rist,
F. Trinter,
S. Grundmann,
M. Waitz,
N. Melzer,
I. Vela-Perez,
T. Mletzko,
A. Pier,
N. Strenger,
J. Siebert,
R. Janssen,
L. Ph. H. Schmidt,
A. N. Artemyev,
M. S. Schöffler,
T. Jahnke,
R. Dörner,
Ph. V. Demekhin
Abstract:
We investigate angular emission distributions of the 1s-photoelectrons of N$_2$ ionized by linearly polarized synchrotron radiation at $h ν=40$ keV. As expected, nondipole contributions cause a very strong forward-backward asymmetry in the measured emission distributions. In addition, we observe an unexpected asymmetry with respect to the polarization direction, which depends on the direction of t…
▽ More
We investigate angular emission distributions of the 1s-photoelectrons of N$_2$ ionized by linearly polarized synchrotron radiation at $h ν=40$ keV. As expected, nondipole contributions cause a very strong forward-backward asymmetry in the measured emission distributions. In addition, we observe an unexpected asymmetry with respect to the polarization direction, which depends on the direction of the molecular fragmentation. In particular, photoelectrons are predominantly emitted in the direction of the forward nitrogen atom. This observation cannot be explained via asymmetries introduced by the initial bound and final continuum electronic states of the oriented molecule. The present simulations assign this asymmetry to a novel nontrivial effect of the recoil imposed to the nuclei by the fast photoelectrons and high-energy photons, which results in a propensity for the ions to break up along the axis of the recoil momentum. The results are of particular importance for the interpretation of future experiments at XFELs operating in the few tens of keV regime, where such nondipole and recoil effects will be essential.
△ Less
Submitted 5 May, 2021;
originally announced May 2021.
-
A new pulse shape description for $α$ particle pulses in a highly-sensitive sub-Kelvin bolometer
Authors:
S. L. Stever,
F. Couchot,
N. Coron,
R. M. J. Janssen,
B. Maffei
Abstract:
The next generation of cosmology space missions will be sensitive to parasitic signals arising from cosmic rays. Using a composite bolometer, we have investigated pulses produced by $α$ particles in order to understand the movement of energy produced by ionising radiation. Using a series of measurements at 100 mK, we have compared the typical fitting algorithm (a mathematical model) with a second…
▽ More
The next generation of cosmology space missions will be sensitive to parasitic signals arising from cosmic rays. Using a composite bolometer, we have investigated pulses produced by $α$ particles in order to understand the movement of energy produced by ionising radiation. Using a series of measurements at 100 mK, we have compared the typical fitting algorithm (a mathematical model) with a second method of pulse interpretation by convolving the detector's thermal response function with a starting profile of thermalised athermal phonons, taking into account the effects of heat propagation. Using this new fitting method, we have eliminated the need for a non-physical quadratic nonlinearity factor produced using more common methods, and we find a pulse form in good agreement with known aspects of thermal physics. This work is carried forward in the effort to produce a physical model for energy deposition in this detector. The modelling is motivated by the reproduction of statistical features in the experimental dataset, and the new interpretation of $α$ pulse shapes represents an improvement in the current understanding of the energy propagation mechanisms in this detector.
△ Less
Submitted 25 July, 2018;
originally announced July 2018.
-
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
Authors:
R. M. J. Janssen,
J. J. A. Baselmans,
A. Endo,
L. Ferrari,
S. J. C. Yates,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid mi…
▽ More
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range $0.09 < ν< 1.1$ THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
△ Less
Submitted 14 August, 2014;
originally announced August 2014.
-
Equivalence of Optical and Electrical Noise Equivalent Power of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors
Authors:
R. M. J. Janssen,
A. Endo,
P. J. de Visser,
T. M. Klapwijk,
J. J. A. Baselmans
Abstract:
We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on the resonance feature of hybrid MKIDs. We determine an electrical NEP from the measured temperature responsivity, quasiparticle recombination time, superconduc…
▽ More
We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on the resonance feature of hybrid MKIDs. We determine an electrical NEP from the measured temperature responsivity, quasiparticle recombination time, superconducting transition temperature and noise spectrum, all of which can be measured in a dark environment. For the two hybrid NbTiN-Al MKIDs studied in detail the electrical NEP is within a factor of two of the optical NEP, which is measured directly using a blackbody source.
△ Less
Submitted 17 November, 2014; v1 submitted 14 August, 2014;
originally announced August 2014.
-
Power-aware applications for scientific cluster and distributed computing
Authors:
David Abdurachmanov,
Peter Elmer,
Giulio Eulisse,
Paola Grosso,
Curtis Hillegas,
Burt Holzman,
Ruben L. Janssen,
Sander Klous,
Robert Knight,
Shahzad Muzaffar
Abstract:
The aggregate power use of computing hardware is an important cost factor in scientific cluster and distributed computing systems. The Worldwide LHC Computing Grid (WLCG) is a major example of such a distributed computing system, used primarily for high throughput computing (HTC) applications. It has a computing capacity and power consumption rivaling that of the largest supercomputers. The comput…
▽ More
The aggregate power use of computing hardware is an important cost factor in scientific cluster and distributed computing systems. The Worldwide LHC Computing Grid (WLCG) is a major example of such a distributed computing system, used primarily for high throughput computing (HTC) applications. It has a computing capacity and power consumption rivaling that of the largest supercomputers. The computing capacity required from this system is also expected to grow over the next decade. Optimizing the power utilization and cost of such systems is thus of great interest.
A number of trends currently underway will provide new opportunities for power-aware optimizations. We discuss how power-aware software applications and scheduling might be used to reduce power consumption, both as autonomous entities and as part of a (globally) distributed system. As concrete examples of computing centers we provide information on the large HEP-focused Tier-1 at FNAL, and the Tigress High Performance Computing Center at Princeton University, which provides HPC resources in a university context.
△ Less
Submitted 22 October, 2014; v1 submitted 28 April, 2014;
originally announced April 2014.
-
High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
Authors:
R. M. J. Janssen,
J. J. A. Baselmans,
A. Endo,
L. Ferrari,
S. J. C. Yates,
A. M. Baryshev,
T. M. Klapwijk
Abstract:
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a sing…
▽ More
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.
△ Less
Submitted 11 November, 2013;
originally announced November 2013.
-
Power Handling and Responsivity of Submicron Wide Superconducting Coplanar Waveguide Resonators
Authors:
R. M. J. Janssen,
A. Endo,
J. J. A. Baselmans,
P. J. de Visser,
R. Barends,
T. M. Klapwijk
Abstract:
The sensitivity of microwave kinetic inductance detectors (MKIDs) based on coplanar waveguides (CPWs) needs to be improved by at least an order of magnitude to satisfy the requirements for space-based terahertz astronomy. Our aim is to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (> 1 μm). CPW resonators w…
▽ More
The sensitivity of microwave kinetic inductance detectors (MKIDs) based on coplanar waveguides (CPWs) needs to be improved by at least an order of magnitude to satisfy the requirements for space-based terahertz astronomy. Our aim is to investigate if this can be achieved by reducing the width of the CPW to much below what has typically been made using optical lithography (> 1 μm). CPW resonators with a central line width as narrow as 300 nm were made in NbTiN using electron beam lithography and reactive ion etching. In a systematic study of quarter-wave CPW resonators with varying widths it is shown that the behavior of responsivity, noise and power handling as a function of width continues down to 300 nm. This encourages the development of narrow KIDs using Al in order to improve their sensitivity.
△ Less
Submitted 4 June, 2012;
originally announced June 2012.