-
Improving the low-energy muon beam quality of the LEM beamline at PSI: Characterisation of ultra-thin carbon foils
Authors:
Gianluca Janka,
Maria Mendes Martins,
Xiaojie Ni,
Zaher Salman,
Andreas Suter,
Thomas Prokscha
Abstract:
The Low-Energy Muon beamline (LEM) at the Paul Scherrer Institute currently stands as the world's only facility providing a continuous beam of low-energy muons with keV energies for conducting muon spin rotation experiments on a nanometer depth scale in heterostructures and near a sample's surface. As such, optimizing the beam quality to reach its full potential is of paramount importance. One of…
▽ More
The Low-Energy Muon beamline (LEM) at the Paul Scherrer Institute currently stands as the world's only facility providing a continuous beam of low-energy muons with keV energies for conducting muon spin rotation experiments on a nanometer depth scale in heterostructures and near a sample's surface. As such, optimizing the beam quality to reach its full potential is of paramount importance. One of the ongoing efforts is dedicated to improving the already applied technique of single muon tagging through the detection of secondary electrons emerging from an ultra-thin carbon foil. In this work, we present the results from installing a thinner foil with a nominal thickness of 0.5 $μg~cm^{-2}$ and compare its performance to that of the previously installed foil with a nominal thickness of 2.0 $μg~cm^{-2}$. Our findings indicate improved beam quality, characterized by smaller beam spots, reduced energy loss and straggling of the muons, and enhanced tagging efficiency. Additionally, we introduce a method utilizing blue laser irradiation for cleaning the carbon foil, further improving and maintaining its characteristics
△ Less
Submitted 23 February, 2024;
originally announced February 2024.
-
Development of wide range photon detection system for muonic X-ray spectroscopy
Authors:
R. Mizuno,
M. Niikura,
T. Y. Saito,
T. Matsuzaki,
H. Sakurai,
A. Amato,
S. Asari,
S. Biswas,
I. Chiu,
L. Gerchow,
Z. Guguchia,
G. Janka,
K. Ninomiya,
N. Ritjoho,
A. Sato,
K. von Schoeler,
D. Tomono,
K. Terada,
C. Wang
Abstract:
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durabi…
▽ More
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durability are studied with standard $γ$-ray sources and in-beam experiment using $^{27}\mathrm{Al}(p, γ){}^{28}\mathrm{Si}$ resonance reaction. The detection system was demonstrated at Paul Scherrer Institute. A calibration method for a photon detector at a muon facility using muonic X-rays of $^{197}$Au and $^{209}$Bi is proposed.
△ Less
Submitted 18 December, 2023; v1 submitted 31 August, 2023;
originally announced September 2023.
-
Pulsed CW laser for long-term spectroscopic measurements at high power in deep-UV
Authors:
Nikita Zhadnov,
Artem Golovizin,
Irene Cortinovis,
Ben Ohayon,
Lucas de Sousa Borges,
Gianluca Janka,
Paolo Crivelli
Abstract:
We present a novel technique for in-vacuum cavity-enhanced UV spectroscopy that allows nearly continuous measurements over several days, minimizing mirror degradation caused by high-power UV radiation. Our method relies on pulsing of the cavity's internal power, which increases the UV intensity to maximum only for short periods when the studied atom is within the cavity mode volume while kee** t…
▽ More
We present a novel technique for in-vacuum cavity-enhanced UV spectroscopy that allows nearly continuous measurements over several days, minimizing mirror degradation caused by high-power UV radiation. Our method relies on pulsing of the cavity's internal power, which increases the UV intensity to maximum only for short periods when the studied atom is within the cavity mode volume while kee** the average power low to prevent mirror degradation. Additionally, this method significantly decreases laser-induced background on charged particle detectors. The described 244 nm laser system is designed for 1S-2S two-photon CW spectroscopy of muonium in the Mu-MASS project. It was tested to provide intracavity powers above 20 W, requiring maintenance only a few times a day. The pulsing technique demonstrates minimal impact on the radiation frequency, with no observed shifts exceeding 15 kHz. Our approach represents a promising new technique for high-precision spectroscopy of atoms in harsh UV environments and demonstrates the feasibility of CW spectroscopy of muonium.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
Update of Muonium 1S-2S transition frequency
Authors:
Irene Cortinovis,
Ben Ohayon,
Lucas de Sousa Borges,
Gianluca Janka,
Artem Golovizin,
Nikita Zhadnov,
Paolo Crivelli
Abstract:
We present an updated value of the Muonium 1S-2S transition frequency, highlighting contributions from different QED corrections as well as the large uncertainty in the Dirac contribution, stemming from the uncertainty of the electron-to-muon mass ratio. Improving the measurement of this spectral line would allow to extract a more accurate determination of fundamental constants, such as the electr…
▽ More
We present an updated value of the Muonium 1S-2S transition frequency, highlighting contributions from different QED corrections as well as the large uncertainty in the Dirac contribution, stemming from the uncertainty of the electron-to-muon mass ratio. Improving the measurement of this spectral line would allow to extract a more accurate determination of fundamental constants, such as the electron-to-muon mass ratio or, combined with the Muonium hyperfine splitting, an independent value of the Rydberg constant. Furthermore we report on the current status of the Mu-MASS experiment, which aims at measuring the Muonium 1S-2S transition frequency at a 10 kHz uncertainty level.
△ Less
Submitted 17 March, 2023; v1 submitted 30 January, 2023;
originally announced January 2023.
-
GermanIum Array for Non-destructive Testing (GIANT) setup for Muon Induced X-ray Emission (MIXE) at the Paul Scherrer Institute
Authors:
Lars Gerchow,
Sayani Biswas,
Gianluca Janka,
Carlos Vigo,
Andreas Knecht,
Stergiani Marina Vogiatzi,
Narongrit Ritjoho,
Thomas Prokscha,
Hubertus Luetkens,
Alex Amato
Abstract:
The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission (MIXE) technique for a non-destructive assessment of elemental compositions. In the recent years, this method has seen a rebirth, improvement and adoption at most mu…
▽ More
The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission (MIXE) technique for a non-destructive assessment of elemental compositions. In the recent years, this method has seen a rebirth, improvement and adoption at most muon facilities around the world. Hereby, the PSI offers unique capabilities with its high-rate continuous muon beam at the Swiss Muon Source (S$μ$S). We report here the decision making, construction and commissioning of a dedicated MIXE spectrometer at PSI, the GermanIum Array for Non-destructive Testing (GIANT) setup. Multiple campaigns highlighted the outstanding capabilities of MIXE at PSI, e.g. resolving down to 1 at% elemental concentrations with as little as 1 h data taking, measuring isotopic ratios for elements from iron to lead, and characterizing gamma rays induced by muon nuclear capture. On-target beamspots were characterized with a dedicated charged particle tracker to be 22.06$\pm$0.18 and 14.45$\pm$0.06 mm for 25 and 45 MeV/c, respectively. Advanced analysis of the High Purity Germanium (HPGe) signals further allows to improve energy and timing resolutions to ~1 keV and 20 ns at 1 MeV, respectively. Within the GIANT setup, an average detector has a photopeak efficiency of $\overline{ε_E}$ =0.11% and an energy resolution of $\overline{σ_E}$ = 0.8 keV at E=1000 keV. The overall performance of the GIANT setup at S$μ$S allowed to start a rich user program with archaeological samples, Li-ion battery research, and collaboration with industry. Future improvements will include a simulation based analysis and a higher degree of automation, e.g. automatic scans of a series of muon momenta and automatic sample changing.
△ Less
Submitted 28 October, 2022;
originally announced October 2022.
-
Measurement of the $2S_{1/2},F$=$0 \rightarrow 2P_{1/2},F$=$1$ transition in Muonium
Authors:
G. Janka,
B. Ohayon,
I. Cortinovis,
Z. Burkley,
L. de Sousa Borges,
E. Depero,
A. Golovizin,
X. Ni,
Z. Salman,
A. Suter,
T. Prokscha,
P. Crivelli
Abstract:
Muons are puzzling physicists since their discovery when they were first thought to be the meson predicted by Yukawa to mediate the strong force. The recent results at Fermilab on the muon g-2 anomaly puts the muonic sector once more under the spotlight and calls for new measurements with this fascinating particle. Here we present the results of the first measurement of the $2S_{1/2},F$=…
▽ More
Muons are puzzling physicists since their discovery when they were first thought to be the meson predicted by Yukawa to mediate the strong force. The recent results at Fermilab on the muon g-2 anomaly puts the muonic sector once more under the spotlight and calls for new measurements with this fascinating particle. Here we present the results of the first measurement of the $2S_{1/2},F$=$0 \rightarrow 2P_{1/2},F$=$1$ transition in Muonium, the hydrogen-like bound state of a positive muon and an electron. The measured value of 580.6 $\pm$6.8 MHz is in agreement with the theoretical calculations. From this measurement a value of the Lamb shift of 1045.5 $\pm$6.8 MHz is extracted, compatible with previous experiments. We also determine for the first time the $2S$ hyperfine splitting in Muonium to be 559.6$\pm$7.2 MHz. The measured transition being isolated from the other hyperfine levels holds the promise to provide an improved determination of the Muonium Lamb shift at a level where bound state QED recoil corrections not accessible in hydrogen could be tested. Such a measurement will also be sensitive to new physics in the muonic sector, e.g. to new bosons which might provide an explanation of the g-2 muon anomaly or Lorentz and CPT violation. We also present the first observation of Muonium in the $n = 3$ excited state opening up the possibility of new precise microwave measurements as realized in hydrogen.
△ Less
Submitted 12 May, 2022;
originally announced May 2022.
-
Positron accumulation in the GBAR experiment
Authors:
P. Blumer,
M. Charlton,
M. Chung,
P. Clade,
P. Comini,
P. Crivelli,
O. Dalkarov,
P. Debu,
L. Dodd,
A. Douillet,
S. Guellati,
P. -A Hervieux,
L. Hilico,
P. Indelicato,
G. Janka,
S. Jonsell,
J. -P. Karr,
B. H. Kim,
E. S. Kim,
S. K. Kim,
Y. Ko,
T. Kosinski,
N. Kuroda,
B. M. Latacz,
B. Lee
, et al. (45 additional authors not shown)
Abstract:
We present a description of the GBAR positron (e+) trap** apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), whic…
▽ More
We present a description of the GBAR positron (e+) trap** apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), which has been cooled to a low temperature, and observing the subsequent H annihilation following free fall. To produce one H+ ion, about 10^10 positrons, efficiently converted into positronium (Ps), together with about 10^7 antiprotons (p), are required. The positrons, produced from an electron linac-based system, are accumulated first in the BGT whereafter they are stacked in the ultra-high vacuum HFT, where we have been able to trap 1.4(2) x 10^9 positrons in 1100 seconds.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
-
Muonium Lamb shift: theory update and experimental prospects
Authors:
Gianluca Janka,
Ben Ohayon,
Paolo Crivelli
Abstract:
We review the theory of the Lamb shift for muonium, provide an updated numerical value and present the prospects of the Mu-MASS collaboration at PSI to improve upon their recent measurement. Due to its smaller nuclear mass, the contributions of the higher-order recoil corrections (160kHz level) and nucleus self-energy 40kHz level) are enhanced for muonium compared to hydrogen where those are below…
▽ More
We review the theory of the Lamb shift for muonium, provide an updated numerical value and present the prospects of the Mu-MASS collaboration at PSI to improve upon their recent measurement. Due to its smaller nuclear mass, the contributions of the higher-order recoil corrections (160kHz level) and nucleus self-energy 40kHz level) are enhanced for muonium compared to hydrogen where those are below the level of the latest measurement performed by Hessels et al. and thus could not be tested yet. The ongoing upgrades to the Mu-MASS setup will open up the possibility to probe these contributions and improve the sensitivity of this measurement to searches for new physics in the muonic sector.
△ Less
Submitted 27 November, 2021;
originally announced November 2021.
-
Precision measurement of the Lamb shift in Muonium
Authors:
B. Ohayon,
G. Janka,
I. Cortinovis,
Z. Burkley,
L. de Sousa Bourges,
E. Depero,
A. Golovizin,
X. Ni,
Z. Salman,
A. Suter,
C. Vigo,
T. Prokscha,
P. Crivelli
Abstract:
We report a new measurement of the $n=2$ Lamb shift in Muonium using microwave spectroscopy. Our result of $1047.2(2.3)_\textrm{stat}(1.1)_\textrm{syst}$ MHz comprises an order of magnitude improvement upon the previous best measurement. This value matches the theoretical calculation within one standard deviation allowing us to set limits on CPT violation in the muonic sector, as well as on new ph…
▽ More
We report a new measurement of the $n=2$ Lamb shift in Muonium using microwave spectroscopy. Our result of $1047.2(2.3)_\textrm{stat}(1.1)_\textrm{syst}$ MHz comprises an order of magnitude improvement upon the previous best measurement. This value matches the theoretical calculation within one standard deviation allowing us to set limits on CPT violation in the muonic sector, as well as on new physics coupled to muons and electrons which could provide an explanation of the muon $g-2$ anomaly.
△ Less
Submitted 30 September, 2021; v1 submitted 29 August, 2021;
originally announced August 2021.
-
Positron production using a 9 MeV electron linac for the GBAR experiment
Authors:
M. Charlton,
J. J. Choi,
M. Chung,
P. Clade,
P. Comini,
P-P. Crepin,
P. Crivelli,
O. Dalkarov,
P. Debu,
L. Dodd,
A. Douillet,
S. Guellati-Khelifa,
P-A. Hervieux,
L. Hilico,
A. Husson,
P. Indelicato,
G. Janka,
S. Jonsell,
J-P. Karr,
B. H. Kim,
E-S. Kim,
S. K. Kim,
Y. Ko,
T. Kosinski,
N. Kuroda
, et al. (45 additional authors not shown)
Abstract:
For the GBAR (Gravitational Behaviour of Antihydrogen at Rest) experiment at CERN's Antiproton Decelerator (AD) facility we have constructed a source of slow positrons, which uses a low-energy electron linear accelerator (linac). The driver linac produces electrons of 9 MeV kinetic energy that create positrons from bremsstrahlung-induced pair production. Staying below 10 MeV ensures no persistent…
▽ More
For the GBAR (Gravitational Behaviour of Antihydrogen at Rest) experiment at CERN's Antiproton Decelerator (AD) facility we have constructed a source of slow positrons, which uses a low-energy electron linear accelerator (linac). The driver linac produces electrons of 9 MeV kinetic energy that create positrons from bremsstrahlung-induced pair production. Staying below 10 MeV ensures no persistent radioactive activation in the target zone and that the radiation level outside the biological shield is safe for public access. An annealed tungsten-mesh assembly placed directly behind the target acts as a positron moderator. The system produces $5\times10^7$ slow positrons per second, a performance demonstrating that a low-energy electron linac is a superior choice over positron-emitting radioactive sources for high positron flux.
△ Less
Submitted 6 October, 2020; v1 submitted 10 June, 2020;
originally announced June 2020.
-
Intense beam of metastable Muonium
Authors:
G. Janka,
B. Ohayon,
Z. Burkley,
L. Gerchow,
N. Kuroda,
X. Ni,
R. Nishi,
Z. Salman,
A. Suter,
M. Tuzi,
C. Vigo,
T. Prokscha,
P. Crivelli
Abstract:
Precision spectroscopy of the Muonium Lamb shift and fine structure requires a robust source of 2S Muonium. To date, the beam-foil technique is the only demonstrated method for creating such a beam in vacuum. Previous experiments using this technique were statistics limited, and new measurements would benefit tremendously from the efficient 2S production at a low energy muon ($<20$ keV) facility.…
▽ More
Precision spectroscopy of the Muonium Lamb shift and fine structure requires a robust source of 2S Muonium. To date, the beam-foil technique is the only demonstrated method for creating such a beam in vacuum. Previous experiments using this technique were statistics limited, and new measurements would benefit tremendously from the efficient 2S production at a low energy muon ($<20$ keV) facility. Such a source of abundant low energy $\mathrm{μ^+}$ has only become available in recent years, e.g. at the Low-Energy Muon beamline at the Paul Scherrer Institute. Using this source, we report on the successful creation of an intense, directed beam of metastable Muonium. We find that even though the theoretical Muonium fraction is maximal in the low energy range of $2-5$ keV, scattering by the foil and transport characteristics of the beamline favor slightly higher $\mathrm{μ^+}$ energies of $7-10$ keV. We estimate that an event detection rate of a few events per second for a future Lamb shift measurement is feasible, enabling an increase in precision by two orders of magnitude over previous determinations.
△ Less
Submitted 6 May, 2020; v1 submitted 5 April, 2020;
originally announced April 2020.
-
Multiple hit reconstruction in large area multiplexed detectors
Authors:
B. Radics,
G. Janka,
D. A. Cooke,
S. Procureur,
P. Crivelli
Abstract:
A novel approach is presented to unfold particle hit positions in tracking detectors with multiplexed readout representing an underdetermined system of linear equations. The method does not use any prior information about the hit positions, the only assumption in the procedure is that isolated hit signals generated on consecutive detector strips follow a smooth distribution. Ambiguities introduced…
▽ More
A novel approach is presented to unfold particle hit positions in tracking detectors with multiplexed readout representing an underdetermined system of linear equations. The method does not use any prior information about the hit positions, the only assumption in the procedure is that isolated hit signals generated on consecutive detector strips follow a smooth distribution. Ambiguities introduced by charge sharing from multiplexing are reduced by using a regularization technique. We have tested this method on a multiplexed 50x50 cm$^{2}$ Micromegas detector with 1037 strips and only 61 readout channels, using cosmic rays, and we have found that single and multiple clusters of hits can be reconstructed with high efficiency.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.