Generation of Spatially Coherent Light at Extreme Ultraviolet Wavelengths
Authors:
Randy A. Bartels,
Ariel Paul,
Hans Green,
Henry C. Kapteyn,
Margaret M. Murnane,
Sterling Backus,
Ivan P. Christov,
Yanwei Liu,
David Attwood,
Chris Jacobsen
Abstract:
We present spatial coherence measurements of extreme-ultraviolet light generated using the process of high-harmonic upconversion of a femtosecond laser. Using a phase-matched hollow-fiber geometry, the generated beam is found to exhibit essentially full spatial coherence. The coherence of this laser-like EUV source is demonstrated by recording Gabor holograms of small objects. This work demonstrat…
▽ More
We present spatial coherence measurements of extreme-ultraviolet light generated using the process of high-harmonic upconversion of a femtosecond laser. Using a phase-matched hollow-fiber geometry, the generated beam is found to exhibit essentially full spatial coherence. The coherence of this laser-like EUV source is demonstrated by recording Gabor holograms of small objects. This work demonstrates the capability to do EUV holography using a tabletop experimental setup. Such an EUV source, with low divergence and high spatial coherence, can be used for experiments such as high-precision metrology, inspection of optical components for EUV lithography (1), and for microscopy and holography (2) with nanometer resolution. Furthermore, the short time duration of the EUV radiation (a few femtoseconds) will enable EUV microscopy and holography to be performed with ultrahigh time resolution.
△ Less
Submitted 28 March, 2024;
originally announced March 2024.
-
Enhancing Dynamical System Modeling through Interpretable Machine Learning Augmentations: A Case Study in Cathodic Electrophoretic Deposition
Authors:
Christian Jacobsen,
Jiayuan Dong,
Mehdi Khalloufi,
Xun Huan,
Karthik Duraisamy,
Maryam Akram,
Wanjiao Liu
Abstract:
We introduce a comprehensive data-driven framework aimed at enhancing the modeling of physical systems, employing inference techniques and machine learning enhancements. As a demonstrative application, we pursue the modeling of cathodic electrophoretic deposition (EPD), commonly known as e-coating. Our approach illustrates a systematic procedure for enhancing physical models by identifying their l…
▽ More
We introduce a comprehensive data-driven framework aimed at enhancing the modeling of physical systems, employing inference techniques and machine learning enhancements. As a demonstrative application, we pursue the modeling of cathodic electrophoretic deposition (EPD), commonly known as e-coating. Our approach illustrates a systematic procedure for enhancing physical models by identifying their limitations through inference on experimental data and introducing adaptable model enhancements to address these shortcomings. We begin by tackling the issue of model parameter identifiability, which reveals aspects of the model that require improvement. To address generalizability , we introduce modifications which also enhance identifiability. However, these modifications do not fully capture essential experimental behaviors. To overcome this limitation, we incorporate interpretable yet flexible augmentations into the baseline model. These augmentations are parameterized by simple fully-connected neural networks (FNNs), and we leverage machine learning tools, particularly Neural Ordinary Differential Equations (Neural ODEs), to learn these augmentations. Our simulations demonstrate that the machine learning-augmented model more accurately captures observed behaviors and improves predictive accuracy. Nevertheless, we contend that while the model updates offer superior performance and capture the relevant physics, we can reduce off-line computational costs by eliminating certain dynamics without compromising accuracy or interpretability in downstream predictions of quantities of interest, particularly film thickness predictions. The entire process outlined here provides a structured approach to leverage data-driven methods. Firstly, it helps us comprehend the root causes of model inaccuracies, and secondly, it offers a principled method for enhancing model performance.
△ Less
Submitted 16 January, 2024;
originally announced January 2024.
-
Disentangling Generative Factors of Physical Fields Using Variational Autoencoders
Authors:
Christian Jacobsen,
Karthik Duraisamy
Abstract:
The ability to extract generative parameters from high-dimensional fields of data in an unsupervised manner is a highly desirable yet unrealized goal in computational physics. This work explores the use of variational autoencoders (VAEs) for non-linear dimension reduction with the specific aim of {\em disentangling} the low-dimensional latent variables to identify independent physical parameters t…
▽ More
The ability to extract generative parameters from high-dimensional fields of data in an unsupervised manner is a highly desirable yet unrealized goal in computational physics. This work explores the use of variational autoencoders (VAEs) for non-linear dimension reduction with the specific aim of {\em disentangling} the low-dimensional latent variables to identify independent physical parameters that generated the data. A disentangled decomposition is interpretable, and can be transferred to a variety of tasks including generative modeling, design optimization, and probabilistic reduced order modelling. A major emphasis of this work is to characterize disentanglement using VAEs while minimally modifying the classic VAE loss function (i.e. the Evidence Lower Bound) to maintain high reconstruction accuracy. The loss landscape is characterized by over-regularized local minima which surround desirable solutions. We illustrate comparisons between disentangled and entangled representations by juxtaposing learned latent distributions and the true generative factors in a model porous flow problem. Hierarchical priors are shown to facilitate the learning of disentangled representations. The regularization loss is unaffected by latent rotation when training with rotationally-invariant priors, and thus learning non-rotationally-invariant priors aids in capturing the properties of generative factors, improving disentanglement. Finally, it is shown that semi-supervised learning - accomplished by labeling a small number of samples ($O(1\%)$) - results in accurate disentangled latent representations that can be consistently learned.
△ Less
Submitted 15 November, 2021; v1 submitted 15 September, 2021;
originally announced September 2021.
-
A matrix-free Levenberg-Marquardt algorithm for efficient ptychographic phase retrieval
Authors:
Saugat Kandel,
S. Maddali,
Youssef S G Nashed,
Stephan O Hruszkewycz,
Chris Jacobsen,
Marc Allain
Abstract:
The phase retrieval problem, where one aims to recover a complex-valued image from far-field intensity measurements, is a classic problem encountered in a range of imaging applications. Modern phase retrieval approaches usually rely on gradient descent methods in a nonlinear minimization framework. Calculating closed-form gradients for use in these methods is tedious work, and formulating second o…
▽ More
The phase retrieval problem, where one aims to recover a complex-valued image from far-field intensity measurements, is a classic problem encountered in a range of imaging applications. Modern phase retrieval approaches usually rely on gradient descent methods in a nonlinear minimization framework. Calculating closed-form gradients for use in these methods is tedious work, and formulating second order derivatives is even more laborious. Additionally, second order techniques often require the storage and inversion of large matrices of partial derivatives, with memory requirements that can be prohibitive for data-rich imaging modalities. We use a reverse-mode automatic differentiation (AD) framework to implement an efficient matrix-free version of the Levenberg-Marquardt (LM) algorithm, a longstanding method that finds popular use in nonlinear least-square minimization problems but which has seen little use in phase retrieval. Furthermore, we extend the basic LM algorithm so that it can be applied for general constrained optimization problems beyond just the least-square applications. Since we use AD, we only need to specify the physics-based forward model for a specific imaging application; the derivative terms are calculated automatically through matrix-vector products, without explicitly forming any large Jacobian or Gauss-Newton matrices. We demonstrate that this algorithm can be used to solve both the unconstrained ptychographic object retrieval problem and the constrained "blind" ptychographic object and probe retrieval problems, under both the Gaussian and Poisson noise models, and that this method outperforms best-in-class first-order ptychographic reconstruction methods: it provides excellent convergence guarantees with (in many cases) a superlinear rate of convergence, all with a computational cost comparable to, or lower than, the tested first-order algorithms.
△ Less
Submitted 26 February, 2021;
originally announced March 2021.
-
Adorym: A multi-platform generic x-ray image reconstruction framework based on automatic differentiation
Authors:
Ming Du,
Saugat Kandel,
Jun**g Deng,
Xiao**g Huang,
Arnaud Demortiere,
Tuan Tu Nguyen,
Remi Tucoulou,
Vincent De Andrade,
Qiaoling **,
Chris Jacobsen
Abstract:
We describe and demonstrate an optimization-based x-ray image reconstruction framework called Adorym. Our framework provides a generic forward model, allowing one code framework to be used for a wide range of imaging methods ranging from near-field holography to and fly-scan ptychographic tomography. By using automatic differentiation for optimization, Adorym has the flexibility to refine experime…
▽ More
We describe and demonstrate an optimization-based x-ray image reconstruction framework called Adorym. Our framework provides a generic forward model, allowing one code framework to be used for a wide range of imaging methods ranging from near-field holography to and fly-scan ptychographic tomography. By using automatic differentiation for optimization, Adorym has the flexibility to refine experimental parameters including probe positions, multiple hologram alignment, and object tilts. It is written with strong support for parallel processing, allowing large datasets to be processed on high-performance computing systems. We demonstrate its use on several experimental datasets to show improved image quality through parameter refinement.
△ Less
Submitted 22 December, 2020;
originally announced December 2020.
-
Relative merits and limiting factors for x-ray and electron microscopy of thick, hydrated organic materials (revised)
Authors:
Ming Du,
Chris Jacobsen
Abstract:
Electron and x-ray microscopes allow one to image the entire, unlabeled structure of hydrated materials at a resolution well beyond what visible light microscopes can achieve. However, both approaches involve ionizing radiation, so that radiation damage must be considered as one of the limits to imaging. Drawing upon earlier work, we describe here a unified approach to estimating the image contras…
▽ More
Electron and x-ray microscopes allow one to image the entire, unlabeled structure of hydrated materials at a resolution well beyond what visible light microscopes can achieve. However, both approaches involve ionizing radiation, so that radiation damage must be considered as one of the limits to imaging. Drawing upon earlier work, we describe here a unified approach to estimating the image contrast (and thus the required exposure and corresponding radiation dose) in both x-ray and electron microscopy. This approach accounts for factors such as plural and inelastic scattering, and (in electron microscopy) the use of energy filters to obtain so-called "zero loss" images. As expected, it shows that electron microscopy offers lower dose for specimens thinner than about 1 micron (such as for studies of macromolecules, viruses, bacteria and archaebacteria, and thin sectioned material), while x-ray microscopy offers superior characteristics for imaging thicker specimen such as whole eukaryotic cells, thick-sectioned tissues, and organs. The required radiation dose scales strongly as a function of the desired spatial resolution, allowing one to understand the limits of live and frozen hydrated specimen imaging. Finally, we consider the factors limiting x-ray microscopy of thicker materials, suggesting that specimens as thick as a whole mouse brain can be imaged with x-ray microscopes without significant image degradation should appropriate image reconstruction methods be identified. The as-published article [Ultramicroscopy 184, 293--309 (2018); doi:10.1016/j.ultramic.2017.10.003] had some minor mistakes that we correct here, with all changes from the as-published article shown in blue.
△ Less
Submitted 21 April, 2020;
originally announced April 2020.
-
Environment-assisted bosonic quantum communications
Authors:
Stefano Pirandola,
Carlo Ottaviani,
Christian S. Jacobsen,
Gaetana Spedalieri,
Samuel L. Braunstein,
Tobias Gehring,
Ulrik L. Andersen
Abstract:
We consider a quantum relay which is used by two parties to perform several continuous-variable protocols of quantum communication, from entanglement distribution (swap** and distillation), to quantum teleportation, and quantum key distribution. The theory of these protocols is suitably extended to a non-Markovian model of decoherence characterized by correlated Gaussian noise in the bosonic env…
▽ More
We consider a quantum relay which is used by two parties to perform several continuous-variable protocols of quantum communication, from entanglement distribution (swap** and distillation), to quantum teleportation, and quantum key distribution. The theory of these protocols is suitably extended to a non-Markovian model of decoherence characterized by correlated Gaussian noise in the bosonic environment. In the worst case scenario where bipartite entanglement is completely lost at the relay, we show that the various protocols can be reactivated by the assistance of classical (separable) correlations in the environment. In fact, above a critical amount, these correlations are able to guarantee the distribution of a weaker form of entanglement (quadripartite), which can be localized by the relay into a stronger form (bipartite) that is exploitable by the parties. Our findings are confirmed by a proof-of-principle experiment where we show, for the first time, that memory effects in the environment can drastically enhance the performance of a quantum relay, well beyond the single-repeater bound for quantum and private communications.
△ Less
Submitted 20 March, 2020;
originally announced March 2020.
-
A Compact, Mobile, Low-Threshold Squeezed Light Source
Authors:
Jens Arnbak,
Christian Scheffmann Jacobsen,
Rayssa Bruzaca de Andrade,
Xueshi Guo,
Jonas Schou Neergaard-Nielsen,
Ulrik Lund Andersen,
Tobias Gehring
Abstract:
Strongly squeezed light finds many important applications within the fields of quantum metrology, quantum communication and quantum computation. However, due to the bulkiness and complexity of most squeezed light sources of today, they are still not a standard tool in quantum optics labs. We have taken the first steps in realizing a compact, high-performance 1550 nm squeezing source based on comme…
▽ More
Strongly squeezed light finds many important applications within the fields of quantum metrology, quantum communication and quantum computation. However, due to the bulkiness and complexity of most squeezed light sources of today, they are still not a standard tool in quantum optics labs. We have taken the first steps in realizing a compact, high-performance 1550 nm squeezing source based on commercially available fiber components combined with a free-space double-resonant parametric down-conversion source. The whole setup, including single-pass second-harmonic generation in a waveguide, fits on a small breadboard and produces 9.3 dB of squeezing at a 5 MHz sideband-frequency. The setup is currently limited by phase noise, but further optimization and development should allow for a 19" sized turn-key squeezing source capable of delivering more than 10 dB of squeezing.
△ Less
Submitted 3 September, 2019;
originally announced September 2019.
-
Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging
Authors:
Ming Du,
Doga Gursoy,
Chris Jacobsen
Abstract:
Different studies in x-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. We present here a numerical study on the dose efficiency of near-field holography (NFH), near-field ptychography (NFP), and far-field ptycho…
▽ More
Different studies in x-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. We present here a numerical study on the dose efficiency of near-field holography (NFH), near-field ptychography (NFP), and far-field ptychography (FFP), where ptychography involves multiple overlap** finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging (CDI), which involves recording a single far-field diffraction pattern, we find that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near, or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.
△ Less
Submitted 11 March, 2020; v1 submitted 16 August, 2019;
originally announced August 2019.
-
Three dimensions, two microscopes, one code: automatic differentiation for x-ray nanotomography beyond the depth of focus limit
Authors:
Ming Du,
Youssef S. G. Nashed,
Saugat Kandel,
Doga Gursoy,
Chris Jacobsen
Abstract:
Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading towards the violation of these assumptions, by combining the high penetration power of x-rays which enables thick specimens to be imaged, with improved spatial resolution which…
▽ More
Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading towards the violation of these assumptions, by combining the high penetration power of x-rays which enables thick specimens to be imaged, with improved spatial resolution which decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation, and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy, and for coherent scanning techniques like ptychography. Our implementation utilizes the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, which demonstrates a much straightforward way to solve optimization problems in computational imaging, and endows our program great flexibility and portability.
△ Less
Submitted 24 May, 2019;
originally announced May 2019.
-
Using Automatic Differentiation as a General Framework for Ptychographic Reconstruction
Authors:
Saugat Kandel,
S. Maddali,
Marc Allain,
Stephan O. Hruszkewycz,
Chris Jacobsen,
Youssef S G Nashed
Abstract:
Coherent diffraction imaging methods enable imaging beyond lens-imposed resolution limits. In these methods, the object can be recovered by minimizing an error metric that quantifies the difference between diffraction patterns as observed, and those calculated from a present guess of the object. Efficient minimization methods require analytical calculation of the derivatives of the error metric, w…
▽ More
Coherent diffraction imaging methods enable imaging beyond lens-imposed resolution limits. In these methods, the object can be recovered by minimizing an error metric that quantifies the difference between diffraction patterns as observed, and those calculated from a present guess of the object. Efficient minimization methods require analytical calculation of the derivatives of the error metric, which is not always straightforward. This limits our ability to explore variations of basic imaging approaches. In this paper, we propose to substitute analytical derivative expressions with the automatic differentiation method, whereby we can achieve object reconstruction by specifying only the physics-based experimental forward model. We demonstrate the generality of the proposed method through straightforward object reconstruction for a variety of complex ptychographic experimental models.
△ Less
Submitted 21 May, 2019; v1 submitted 8 February, 2019;
originally announced February 2019.
-
Processing of X-ray Microcalorimeter Data with Pulse Shape Variation using Principal Component Analysis
Authors:
Daikang Yan,
Thomas Cecil,
Lisa Gades,
Chris Jacobsen,
Timothy Madden,
Antonino Miceli
Abstract:
We present a method using principal component analysis (PCA) to process x-ray pulses with severe shape variation where traditional optimal filter methods fail. We demonstrate that PCA is able to noise-filter and extract energy information from x-ray pulses despite their different shapes. We apply this method to a dataset from an x-ray thermal kinetic inductance detector which has severe pulse shap…
▽ More
We present a method using principal component analysis (PCA) to process x-ray pulses with severe shape variation where traditional optimal filter methods fail. We demonstrate that PCA is able to noise-filter and extract energy information from x-ray pulses despite their different shapes. We apply this method to a dataset from an x-ray thermal kinetic inductance detector which has severe pulse shape variation arising from position-dependent absorption.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.
-
MDI-QKD: Continuous- versus discrete-variables at metropolitan distances
Authors:
Stefano Pirandola,
Carlo Ottaviani,
Gaetana Spedalieri,
Christian Weedbrook,
Samuel L. Braunstein,
Seth Lloyd,
Tobias Gehring,
Christian S. Jacobsen,
Ulrik L. Andersen
Abstract:
In a comment, Xu, Curty, Qi, Qian, and Lo claimed that discrete-variable (DV) measurement device independent (MDI) quantum key distribution (QKD) would compete with its continuous-variable (CV) counterpart at metropolitan distances. Actually, Xu et al.'s analysis supports exactly the opposite by showing that the experimental rate of our CV protocol (achieved with practical room-temperature devices…
▽ More
In a comment, Xu, Curty, Qi, Qian, and Lo claimed that discrete-variable (DV) measurement device independent (MDI) quantum key distribution (QKD) would compete with its continuous-variable (CV) counterpart at metropolitan distances. Actually, Xu et al.'s analysis supports exactly the opposite by showing that the experimental rate of our CV protocol (achieved with practical room-temperature devices) remains one order of magnitude higher than their purely-numerical and over-optimistic extrapolation for qubits, based on nearly-ideal parameters and cryogenic detectors (unsuitable solutions for a realistic metropolitan network, which is expected to run on cheap room-temperature devices, potentially even mobile). The experimental rate of our protocol (expressed as bits per relay use) is confirmed to be two-three orders of magnitude higher than the rate of any realistic simulation of practical DV-MDI-QKD over short-medium distances. Of course this does not mean that DV-MDI-QKD networks should not be investigated or built, but increasing their rate is a non-trivial practical problem clearly beyond the analysis of Xu et al. Finally, in order to clarify the facts, we also refute a series of incorrect arguments against CV-MDI-QKD and, more generally, CV-QKD, which were made by Xu et al. with the goal of supporting their thesis.
△ Less
Submitted 1 August, 2015; v1 submitted 22 June, 2015;
originally announced June 2015.
-
Non-Markovian Reactivation of Quantum Relays
Authors:
Stefano Pirandola,
Carlo Ottaviani,
Christian S. Jacobsen,
Gaetana Spedalieri,
Samuel L. Braunstein,
Tobias Gehring,
Ulrik L. Andersen
Abstract:
We consider a quantum relay which is used by two parties to perform several continuous-variable protocols: Entanglement swap**, distillation, quantum teleportation, and quantum key distribution. The theory of these protocols is extended to a non-Markovian model of decoherence characterized by correlated Gaussian noise. Even if bipartite entanglement is completely lost at the relay, we show that…
▽ More
We consider a quantum relay which is used by two parties to perform several continuous-variable protocols: Entanglement swap**, distillation, quantum teleportation, and quantum key distribution. The theory of these protocols is extended to a non-Markovian model of decoherence characterized by correlated Gaussian noise. Even if bipartite entanglement is completely lost at the relay, we show that the various protocols can progressively be reactivated by the separable noise-correlations of the environment. In fact, above a critical amount, these correlations are able to restore the distribution of quadripartite entanglement, which can be localized into an exploitable bipartite form by the action of the relay. Our findings are confirmed by a proof-of-principle experiment and show the potential advantages of non-Markovian effects in a quantum network architecture.
△ Less
Submitted 27 May, 2015;
originally announced May 2015.
-
High-rate quantum cryptography in untrusted networks
Authors:
Stefano Pirandola,
Carlo Ottaviani,
Gaetana Spedalieri,
Christian Weedbrook,
Samuel L. Braunstein,
Seth Lloyd,
Tobias Gehring,
Christian S. Jacobsen,
Ulrik L. Andersen
Abstract:
We extend the field of continuous-variable quantum cryptography to a network formulation where two honest parties connect to an untrusted relay by insecure quantum links. To generate secret correlations, they transmit coherent states to the relay where a continuous-variable Bell detection is performed and the outcome broadcast. Even though the detection could be fully corrupted and the links subje…
▽ More
We extend the field of continuous-variable quantum cryptography to a network formulation where two honest parties connect to an untrusted relay by insecure quantum links. To generate secret correlations, they transmit coherent states to the relay where a continuous-variable Bell detection is performed and the outcome broadcast. Even though the detection could be fully corrupted and the links subject to optimal coherent attacks, the honest parties can still extract a secret key, achieving high rates when the relay is proximal to one party, as typical in public networks with access points or proxy servers. Our theory is confirmed by an experiment generating key-rates which are orders of magnitude higher than those achievable with discrete-variable protocols. Thus, using the cheapest possible quantum resources, we experimentally show the possibility of high-rate quantum key distribution in network topologies where direct links are missing between end-users and intermediate relays cannot be trusted.
△ Less
Submitted 1 August, 2014; v1 submitted 14 December, 2013;
originally announced December 2013.
-
Progress in Three-Dimensional Coherent X-Ray Diffraction Imaging
Authors:
S. Marchesini,
H. N. Chapman,
A. Barty,
A. Noy,
S. P. Hau-Riege,
J. M. Kinney,
C. Cui,
M. R. Howells,
R. Rosen,
J. C. H. Spence,
U. Weierstall,
D. Shapiro,
T. Beetz,
C. Jacobsen,
E. Lima,
A. M. Minor,
H. He
Abstract:
The Fourier inversion of phased coherent diffraction patterns offers images without the resolution and depth-of-focus limitations of lens-based tomographic systems. We report on our recent experimental images inverted using recent developments in phase retrieval algorithms, and summarize efforts that led to these accomplishments. These include ab-initio reconstruction of a two-dimensional test p…
▽ More
The Fourier inversion of phased coherent diffraction patterns offers images without the resolution and depth-of-focus limitations of lens-based tomographic systems. We report on our recent experimental images inverted using recent developments in phase retrieval algorithms, and summarize efforts that led to these accomplishments. These include ab-initio reconstruction of a two-dimensional test pattern, infinite depth of focus image of a thick object, and its high-resolution (~10 nm resolution) three-dimensional image. Developments on the structural imaging of low density aerogel samples are discussed.
△ Less
Submitted 6 October, 2005; v1 submitted 4 October, 2005;
originally announced October 2005.
-
High-resolution ab initio three-dimensional X-ray diffraction microscopy
Authors:
H. N. Chapman,
A. Barty,
S. Marchesini,
A. Noy,
C. Cui,
M. R. Howells,
R. Rosen,
H. He,
J. C. H. Spence,
U. Weierstall,
T. Beetz,
C. Jacobsen,
D. Shapiro
Abstract:
Coherent X-ray diffraction microscopy is a method of imaging non-periodic isolated objects at resolutions only limited, in principle, by the largest scattering angles recorded. We demonstrate X-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the 3D diffraction data u…
▽ More
Coherent X-ray diffraction microscopy is a method of imaging non-periodic isolated objects at resolutions only limited, in principle, by the largest scattering angles recorded. We demonstrate X-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the 3D diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a non-periodic object. We also construct 2D images of thick objects with infinite depth of focus (without loss of transverse spatial resolution). These methods can be used to image biological and materials science samples at high resolution using X-ray undulator radiation, and establishes the techniques to be used in atomic-resolution ultrafast imaging at X-ray free-electron laser sources.
△ Less
Submitted 8 September, 2005;
originally announced September 2005.
-
An assessment of the resolution limitation due to radiation-damage in x-ray diffraction microscopy
Authors:
M. R. Howells,
T. Beetz,
H. N. Chapman,
C. Cui,
J. M. Holton,
C. J. Jacobsen,
J. Kirz E. Lima,
S. Marchesini,
H. Miao,
D. Sayre,
D. A. Shapiro,
J. C. H. Spence
Abstract:
X-ray diffraction microscopy (XDM) is a new form of x-ray imaging that is being practiced at several third-generation synchrotron-radiation x-ray facilities. Although only five years have elapsed since the technique was first introduced, it has made rapid progress in demonstrating high-resolution threedimensional imaging and promises few-nm resolution with much larger samples than can be imaged…
▽ More
X-ray diffraction microscopy (XDM) is a new form of x-ray imaging that is being practiced at several third-generation synchrotron-radiation x-ray facilities. Although only five years have elapsed since the technique was first introduced, it has made rapid progress in demonstrating high-resolution threedimensional imaging and promises few-nm resolution with much larger samples than can be imaged in the transmission electron microscope. Both life- and materials-science applications of XDM are intended, and it is expected that the principal limitation to resolution will be radiation damage for life science and the coherent power of available x-ray sources for material science. In this paper we address the question of the role of radiation damage. We use a statistical analysis based on the so-called "dose fractionation theorem" of Hegerl and Hoppe to calculate the dose needed to make an image of a lifescience sample by XDM with a given resolution. We conclude that the needed dose scales with the inverse fourth power of the resolution and present experimental evidence to support this finding. To determine the maximum tolerable dose we have assembled a number of data taken from the literature plus some measurements of our own which cover ranges of resolution that are not well covered by reports in the literature. The tentative conclusion of this study is that XDM should be able to image frozen-hydrated protein samples at a resolution of about 10 nm with "Rose-criterion" image quality.
△ Less
Submitted 10 February, 2005;
originally announced February 2005.
-
Low-loss photonic crystal fibers for transmission systems and their dispersion properties
Authors:
M. D. Nielsen,
C. Jacobsen,
N. A. Mortensen,
J. R. Folkenberg,
H. R. Simonsen
Abstract:
We report on a single-mode photonic crystal fiber with attenuation and effective area at 1550 nm of 0.48 dB/km and 130 square-micron, respectively. This is, to our knowledge, the lowest loss reported for a PCF not made from VAD prepared silica and at the same time the largest effective area for a low-loss (< 1 dB/km) PCF. We briefly discuss the future applications of PCFs for data transmission a…
▽ More
We report on a single-mode photonic crystal fiber with attenuation and effective area at 1550 nm of 0.48 dB/km and 130 square-micron, respectively. This is, to our knowledge, the lowest loss reported for a PCF not made from VAD prepared silica and at the same time the largest effective area for a low-loss (< 1 dB/km) PCF. We briefly discuss the future applications of PCFs for data transmission and show for the first time, both numerically and experimentally, how the group velocity dispersion is related to the mode field diameter
△ Less
Submitted 26 March, 2004;
originally announced March 2004.