-
Time-Dependent Density Functional Theory Simulation for Analyzing Neutralization Process of Hydrogen Ion Injected onto Tungsten Surfaces
Authors:
Yuto Toda,
Arimichi Takayama,
Atsushi M. Ito
Abstract:
We have performed time-dependent density functional theory simulations for the neutralization process of a hydrogen ion injected at 100eV onto the (110) surface of tungsten material. We have also proposed a method for evaluating the detection probability of electrons in a small region. This probability is interpreted as that of detecting hydrogen in each state: positive ion, neutral atom, and nega…
▽ More
We have performed time-dependent density functional theory simulations for the neutralization process of a hydrogen ion injected at 100eV onto the (110) surface of tungsten material. We have also proposed a method for evaluating the detection probability of electrons in a small region. This probability is interpreted as that of detecting hydrogen in each state: positive ion, neutral atom, and negative ion. As a result, the probabilities of detecting hydrogen after a collision as a positive ion, neutral atom, and negative ion were approximately 30 percent, 50 percent, and 20 percent, respectively.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
Quantum Electron Dynamics in Helium Ion Injection onto Tungsten Surfaces by Time-Dependent Density Functional Theory
Authors:
Atsushi M. Ito,
Yuto Toda,
Arimichi Takayama
Abstract:
The neutralization process of an ion particle on a surface is key issue of the plasma-wall interaction (PWI). We investigated helium (He) ion injection onto a tungsten surface using time-dependent density functional theory (TDDFT) simulation. We developed the TDDFT code QUMASUN for this study, simulating the process of electron transfer from the surface to the He nucleus by solving the time evolut…
▽ More
The neutralization process of an ion particle on a surface is key issue of the plasma-wall interaction (PWI). We investigated helium (He) ion injection onto a tungsten surface using time-dependent density functional theory (TDDFT) simulation. We developed the TDDFT code QUMASUN for this study, simulating the process of electron transfer from the surface to the He nucleus by solving the time evolution of electron wave function and the classical motion of nuclei simultaneously. Our results show that the probabilities of injected $\text{He}^{2+}$ changing into $\text{He}^{1+}$ and $\text{He}^{0}$ on the surface are approximately 40 percent and 13 percent, respectively. The captured electrons by $\text{He}^{1+}$ and $\text{He}^{0}$ predominantly occupy the 2s and 2p orbitals, corresponding to excited states. In addition, we stated some challenges for applying TDDFT to plasma-wall interactions.
△ Less
Submitted 2 July, 2024;
originally announced July 2024.
-
YAP:Ce scintillator as an absolute ultracold neutron detector
Authors:
M. Krivoš,
Z. Tang,
N. Floyd,
C. L. Morris,
M. Blatnik,
C. Cude-Woods,
S. M. Clayton,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
M. Makela,
I. F. Martinez,
A. S. C. Navazo,
C. M. O'Shaughnessy,
E. L. Renner,
R. W. Pattie,
A. R. Young
Abstract:
The upcoming UCNProBe experiment at Los Alamos National Laboratory will measure the $β$-decay rate of free neutrons with different systematic uncertainties than previous beam-based neutron lifetime experiments. We have developed a new $^{10}$B-coated YAP:Ce scintillator whose properties are presented. The advantage of the YAP:Ce scintillator is its high Fermi potential, which reduces the probabili…
▽ More
The upcoming UCNProBe experiment at Los Alamos National Laboratory will measure the $β$-decay rate of free neutrons with different systematic uncertainties than previous beam-based neutron lifetime experiments. We have developed a new $^{10}$B-coated YAP:Ce scintillator whose properties are presented. The advantage of the YAP:Ce scintillator is its high Fermi potential, which reduces the probability for upscattering of ultracold neutrons, and its short decay time, which is important at high counting rates. Birks' coefficient of YAP:Ce was measured to be ($5.56^{+0.05}_{-0.30})\times 10^{-4}$ cm/MeV and light losses due to 120 nm of $^{10}$B-coating to be about 60%. The loss of light from YAP:Ce due to transmission through deuterated polystyrene scintillator was about 50%. The efficiency for counting neutrons that are captured on the $^{10}$B coating is (86.82 $\pm$ 2.61)%. Measurement with ultracold neutrons showed that YAP:Ce crystal counted 8% to 28% more UCNs compared to ZnS screen. This may be due to an uneven coating of $^{10}$B on the rough surface.
△ Less
Submitted 27 March, 2024;
originally announced May 2024.
-
Development of Two-Dimensional Neutron Imager with a Sandwich Configuration
Authors:
Y. Kamiya,
R. Nishimura,
S. Mitsui,
Z. Wang,
C. L. Morris,
M. Makela,
S. M. Clayton,
J. K. Baldwin,
T. M. Ito,
S. Akamatsu,
H. Iwase,
Y. Arai,
J. Murata,
S. Asai
Abstract:
We have developed a two-dimensional neutron imager based on a semiconductor pixelated sensor, especially designed for experiments measuring of a spatial and a temporal behavior of quantum bound states of ultra-cold neutrons. Through these measurements, we expect to measure the ratio between the inertial and gravitational masses of neutrons and to test the equivalence principle in the quantum regim…
▽ More
We have developed a two-dimensional neutron imager based on a semiconductor pixelated sensor, especially designed for experiments measuring of a spatial and a temporal behavior of quantum bound states of ultra-cold neutrons. Through these measurements, we expect to measure the ratio between the inertial and gravitational masses of neutrons and to test the equivalence principle in the quantum regime. As one of the principal neutron imagers, we fabricated a sensor with a sandwich configuration, named 10B-INTPIX4-sw, and tested its response to ultra-cold neutrons at the Los Alamos Neutron Science Center (LANSCE). We observed simultaneous events on both sandwiching sensors without significant loss of detection efficiency. The efficiency was evaluated to be about 16%, relative to the 10B/ZnS reference detector. The coincidence condition reduces its efficiency by a factor of about 3.
△ Less
Submitted 19 April, 2024;
originally announced April 2024.
-
Scintillation characteristics of the EJ-299-02H scintillator
Authors:
N. Floyd,
Md. T. Hassan,
Z. Tang,
M. Krivos,
M. Blatnik,
S. M. Clayton,
C. Cude-Woods,
A. T. Holley,
T. M. Ito,
B. A. Johnson,
C. -Y. Liu,
M. Makela,
C. L. Morris,
A. S. C. Navazo,
C. M. O'Shaughnessy,
E. L. Renner,
R. W. Pattie,
A. R. Young
Abstract:
A study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer, and the relative light outputs from the decay of $^{241}$Am and Compton scattering of electrons were used to extract the quenching parameter. With these characteristics of…
▽ More
A study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer, and the relative light outputs from the decay of $^{241}$Am and Compton scattering of electrons were used to extract the quenching parameter. With these characteristics of the material known, the light yield of the scintillator can be calculated. The ability to make these scintillators deuterated, accompanied by its relatively thin dead layer, make it ideal for use in UCN experiment, where the light yield of decay electrons and alphas from neutron capture are critical for counting events.
△ Less
Submitted 27 March, 2024; v1 submitted 29 September, 2023;
originally announced October 2023.
-
Characterization of the new Ultracold Neutron beamline at the LANL UCN facility
Authors:
D. K. -T. Wong,
M. T. Hassan,
J. F. Burdine,
T. E. Chupp,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
T. M. Ito,
C. -Y. Liu,
M. Makela,
C. L. Morris,
C. M. O'Shaughnessy,
A. Reid,
N. Sachdeva,
W. Uhrich
Abstract:
The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey's method of separated oscillatory fields to search for a nEDM. In this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate…
▽ More
The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey's method of separated oscillatory fields to search for a nEDM. In this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate a sufficient number of stored polarized UCN to achieve a statistical uncertainty of $δd_n = 2\times 10^{-27}$~$e\cdot\text{cm}$ in 5 calendar years of running. We also present an analytical model describing data that provides a simple parameterization of the input UCN energy spectrum on the new beamline.
△ Less
Submitted 17 January, 2023; v1 submitted 30 August, 2022;
originally announced September 2022.
-
Experimental study of cavitating flow influenced by heat transfer from heated hydrofoil
Authors:
Junnosuke Okajima,
Masaki Ito,
Yuka Iga
Abstract:
This study experimentally investigated the influence of heat transfer from a heated hydrofoil on cavitating flow to understand the evaporation phenomenon under high-heat-flux and high-speed conditions. A temperature difference was generated between the hydrofoil and mainstream by installing an aluminum nitride heater in a NACA0015 hydrofoil fabricated from copper. A cavitation experiment was perfo…
▽ More
This study experimentally investigated the influence of heat transfer from a heated hydrofoil on cavitating flow to understand the evaporation phenomenon under high-heat-flux and high-speed conditions. A temperature difference was generated between the hydrofoil and mainstream by installing an aluminum nitride heater in a NACA0015 hydrofoil fabricated from copper. A cavitation experiment was performed in a high-temperature water cavitation tunnel at the Institute of Fluid Science, Tohoku University. The effect of heating on cavitating flow was evaluated by changing the mainstream velocity and pressure, namely the cavitation number, at a fixed heater power of 860 W. Results showed that the heat transfer from the hydrofoil affected cavitating flow in terms of the cavity length, cavity aspect, and periodicity. The effect on the cavity length became stronger at a lower velocity owing to a higher hydrofoil temperature. The variation in periodicity implied that the heating effect reduced the unsteadiness of cavitation. A modified cavitation number was proposed by considering the heat transfer from the heated wall. A thermal correction term was derived by considering that the fluid temperature close to the heated hydrofoil was affected by the turbulent convective heat transfer between the mainstream and hydrofoil. The corrected cavitation number can be considered as a parameter that describes the cavity length in the isothermal and heated cases in a unified expression.
△ Less
Submitted 1 July, 2022;
originally announced July 2022.
-
Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap
Authors:
C. Cude-Woods,
F. M. Gonzalez,
E. M. Fries,
T. Bailey,
M. Blatnik,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
S. A. Currie,
M. Dawid,
B. W. Filippone,
W. Fox,
P. Geltenbort,
E. George,
L. Hayen,
K. P. Hickerson,
M. A. Hoffbauer,
K. Hoffman,
A. T. Holley,
T. M. Ito,
A. Komives,
C. -Y. Liu,
M. Makela,
C. L. Morris,
R. Musedinovic
, et al. (17 additional authors not shown)
Abstract:
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for inve…
▽ More
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.
△ Less
Submitted 4 May, 2022;
originally announced May 2022.
-
A study of DC electrical breakdown in liquid helium through analysis of the empirical breakdown field distributions
Authors:
N. S. Phan,
W. Wei,
B. Beaumont,
N. Bouman,
S. M. Clayton,
S. A. Currie,
T. M. Ito,
J. C. Ramsey,
G. M. Seidel
Abstract:
We report results from a study on electrical breakdown in liquid helium using near-uniform-field stainless steel electrodes with a stressed area of $\sim$0.725 cm$^2$. The distribution of the breakdown field is obtained for temperatures between 1.7 K and 4.0 K, pressures between the saturated vapor pressure and 626 Torr, and with electrodes of different surface polishes. A data-based approach for…
▽ More
We report results from a study on electrical breakdown in liquid helium using near-uniform-field stainless steel electrodes with a stressed area of $\sim$0.725 cm$^2$. The distribution of the breakdown field is obtained for temperatures between 1.7 K and 4.0 K, pressures between the saturated vapor pressure and 626 Torr, and with electrodes of different surface polishes. A data-based approach for determining the electrode-surface-area scaling of the breakdown field is presented. The dependence of the breakdown probability on the field strength as extracted from the breakdown field distribution data is used to show that breakdown is a surface phenomenon closely correlated with Fowler-Nordheim field emission from asperities on the cathode. We show that the results from this analysis provides an explanation for the supposed electrode gap-size effect and also allows for a determination of the breakdown-field distribution for arbitrary shaped electrodes. Most importantly, the analysis method presented in this work can be extended to other noble liquids to explore the dependencies for electrical breakdown in those media.
△ Less
Submitted 16 November, 2020;
originally announced November 2020.
-
Ultracold Neutron Properties of the Eljen-299-02D deuterated scintillator
Authors:
Z. Tang,
E. B. Watkins,
S. M. Clayton,
S. A. Currie,
D. E. Fellers,
Md. T. Hassan,
D. E. Hooks,
T. M. Ito,
S. K. Lawrence,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
L. P. Neukirch,
A. Saunders,
C. M. O'Shaughnessy,
C. Cude-Woods,
J. H. Choi,
A. R. Young,
B. A. Zeck,
F. Gonzalez,
C. Y. Liu,
N. C. Floyd,
K. P. Hickerson,
A. T. Holley,
B. A. Johnson
, et al. (2 additional authors not shown)
Abstract:
In this paper we report studies of the Fermi potential and loss per bounce of ultracold neutron (UCN) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enables a wide variety of applications in fundamental neutron research.
In this paper we report studies of the Fermi potential and loss per bounce of ultracold neutron (UCN) on a deuterated scintillator (Eljen-299-02D). These UCN properties of the scintillator enables a wide variety of applications in fundamental neutron research.
△ Less
Submitted 25 September, 2020;
originally announced September 2020.
-
New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the European Spallation Source
Authors:
A. Addazi,
K. Anderson,
S. Ansell,
K. Babu,
J. Barrow,
D. V. Baxter,
P. M. Bentley,
Z. Berezhiani,
R. Bevilacqua,
C. Bohm,
G. Brooijmans,
J. Broussard,
R. Biondi,
B. Dev,
C. Crawford,
A. Dolgov,
K. Dunne,
P. Fierlinger,
M. R. Fitzsimmons,
A. Fomin,
M. Frost,
S. Gardner,
A. Galindo-Uribarri,
E. Golubeva,
S. Girmohanta
, et al. (70 additional authors not shown)
Abstract:
The violation of Baryon Number, $\mathcal{B}$, is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR %experiment program is a proposed two-stage experiment at the European Spallation Source (ESS) to search for baryon numbe…
▽ More
The violation of Baryon Number, $\mathcal{B}$, is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR %experiment program is a proposed two-stage experiment at the European Spallation Source (ESS) to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron-antineutron oscillation ($n\rightarrow \bar{n}$) via mixing, neutron-antineutron oscillation via regeneration from a sterile neutron state ($n\rightarrow [n',\bar{n}'] \rightarrow \bar{n}$), and neutron disappearance ($n\rightarrow n'$); the effective $Δ\mathcal{B}=0$ process of neutron regeneration ($n\rightarrow [n',\bar{n}'] \rightarrow n$) is also possible. The program can be used to discover and characterise mixing in the neutron, antineutron, and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis, the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.
△ Less
Submitted 8 June, 2020;
originally announced June 2020.
-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Fractal Patterns in Spatial Distribution of Population by Age Group
Authors:
Mariko I. Ito,
Takaaki Ohnishi
Abstract:
Multifractality is one of the patterns observed in spatial distributions of populations. In this study, we performed multifractal analysis for populations by age group in the capital area of Japan. Each population group generally exhibited the property of densely populated locations being relatively connected to each other. We also investigated the dependence of multifractality on the age group. M…
▽ More
Multifractality is one of the patterns observed in spatial distributions of populations. In this study, we performed multifractal analysis for populations by age group in the capital area of Japan. Each population group generally exhibited the property of densely populated locations being relatively connected to each other. We also investigated the dependence of multifractality on the age group. Multifractal measures showed that the group consisting of young working-age people exhibits strong heterogeneity and concentration of population, while the population consisting of elder people exhibits a relatively homogeneous nature.
△ Less
Submitted 8 May, 2020;
originally announced May 2020.
-
Effect of an electric field on liquid helium scintillation produced by fast electrons
Authors:
N. S. Phan,
V. Cianciolo,
S. M. Clayton,
S. A. Currie,
R. Dipert,
T. M. Ito,
S. W. T. MacDonald,
C. M. O'Shaughnessy,
J. C. Ramsey,
G. M. Seidel,
E. Smith,
E. Tang,
Z. Tang,
W. Yao
Abstract:
The dependence on applied electric field ($0 - 40$ kV/cm) of the scintillation light produced by fast electrons and $α$ particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution…
▽ More
The dependence on applied electric field ($0 - 40$ kV/cm) of the scintillation light produced by fast electrons and $α$ particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of particles, the reduction in the intensity of the scintillation signal due to the applied field exhibits an apparent temperature dependence. Using an approximate solution of the Debye-Smoluchowski equation, we show that the apparent temperature dependence for electrons can be explained by the time required for geminate pairs to recombine relative to the detector signal integration time. This finding indicates that the spatial distribution of secondary electrons with respect to their geminate partners possesses a heavy, non-Gaussian tail at larger separations, and has a dependence on the energy of the primary ionization electron. We discuss the potential application of this result to pulse shape analysis for particle detection and discrimination.
△ Less
Submitted 14 September, 2020; v1 submitted 6 May, 2020;
originally announced May 2020.
-
Weighted Network Analysis of Biologically Relevant Chemical Spaces
Authors:
Mariko I. Ito,
Takaaki Ohnishi
Abstract:
In cheminformatics, network representations of the space of compounds have been suggested extensively. Among these, the threshold-network consists of nodes representing molecules. In this network representation, two molecules are connected by a link if the Tanimoto coefficient, a similarity measure, between them exceeds a preset threshold. However, the topology of the threshold-network is affected…
▽ More
In cheminformatics, network representations of the space of compounds have been suggested extensively. Among these, the threshold-network consists of nodes representing molecules. In this network representation, two molecules are connected by a link if the Tanimoto coefficient, a similarity measure, between them exceeds a preset threshold. However, the topology of the threshold-network is affected significantly by the preset threshold. In this study, we collected the data of biologically relevant compounds and bioactivities. We defined the weighted network where the weight of each link between the nodes equals the Tanimoto coefficient between the bioactive compounds (nodes) without using the threshold. We investigated the relationship between the strength of the link connection and the bioactivity closeness in the weighted networks. We found that compounds with significantly high or low bioactivity have a stronger connection than those in the overall network.
△ Less
Submitted 12 November, 2019;
originally announced November 2019.
-
A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment
Authors:
M. W. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baessler,
L. Barron-Palos,
L. M. Bartoszek,
D. H. Beck,
M. Behzadipour,
I. Berkutov,
J. Bessuille,
M. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallati…
▽ More
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.
△ Less
Submitted 20 November, 2019; v1 submitted 26 August, 2019;
originally announced August 2019.
-
A next-generation inverse-geometry spallation-driven ultracold neutron source
Authors:
K. K. H. Leung,
G. Muhrer,
T. Hügle,
T. M. Ito,
E. M. Lutz,
M. Makela,
C. L. Morris,
R. W. Pattie, Jr.,
A. Saunders,
A. R. Young
Abstract:
The physics model of a next-generation spallation-driven high-current ultracold neutron (UCN) source capable of delivering an extracted UCN rate of around an-order-of-magnitude higher than the strongest proposed sources, and around three-orders-of-magnitude higher than existing sources, is presented. This UCN-current-optimized source would dramatically improve cutting-edge UCN measurements that ar…
▽ More
The physics model of a next-generation spallation-driven high-current ultracold neutron (UCN) source capable of delivering an extracted UCN rate of around an-order-of-magnitude higher than the strongest proposed sources, and around three-orders-of-magnitude higher than existing sources, is presented. This UCN-current-optimized source would dramatically improve cutting-edge UCN measurements that are currently statistically limited. A novel "Inverse Geometry" design is used with 40 L of superfluid $^4$He (He-II), which acts as a converter of cold neutrons (CNs) to UCNs, cooled with state-of-the-art sub-cooled cryogenic technology to $\sim$1.6 K. Our design is optimized for a 100 W maximum heat load constraint on the He-II and its vessel. In our geometry, the spallation target is wrapped symmetrically around the UCN converter to permit raster scanning the proton beam over a relatively large volume of tungsten spallation target to reduce the demand on the cooling requirements, which makes it reasonable to assume that water edge-cooling only is sufficient. Our design is refined in several steps to reach $P_{UCN}=2.1\times10^9\,/$s under our other restriction of 1 MW maximum available proton beam power. We then study effects of the He-II scattering kernel as well as reductions in $P_{UCN}$ due to pressurization to reach $P_{UCN}=1.8\times10^9\,/$s. Finally, we provide a design for the UCN extraction system that takes into account the required He-II heat transport properties and implementation of a He-II containment foil that allows UCN transmission. We estimate a total useful UCN current from our source of $R_{use}=5\times10^8\,/$s from a 18 cm diameter guide 5 m from the source. Under a conservative "no return" approximation, this rate can produce an extracted density of $>1\times10^4\,/$cm$^3$ in $<$1000~L external experimental volumes with a $^{58}$Ni (335 neV) cut-off potential.
△ Less
Submitted 24 October, 2019; v1 submitted 23 May, 2019;
originally announced May 2019.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
Authors:
K. Kuk,
C. Cude-Woods,
C. R. Chavez,
J. H. Choi,
J. Estrada,
M. Hoffbauer,
M. Makela,
P. Merkel,
C. L. Morris,
E. Ramberg,
Z. Wang,
T. Bailey,
M. Blatnik,
E. R. Adamek,
L. J. Broussard,
M. A. -P. Brown,
N. B. Callahan,
S. M. Clayton,
S. A. Currie,
X. Ding,
D. Dinger,
B. Filippone,
E. M. Fries,
P. Geltenbort,
E. George
, et al. (26 additional authors not shown)
Abstract:
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolutio…
▽ More
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $α$, $^7$Li and $γ$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.
△ Less
Submitted 28 February, 2019;
originally announced March 2019.
-
The GlueX Start Counter Detector
Authors:
Eric Pooser,
Fernando Barbosa,
Werner Boeglin,
Charles Hutton,
Mark Ito,
Mahmoud Kamel,
Puneet Khetarpal,
Anthony Llodra,
Joseph Sandoval,
Simon Taylor,
Timothy Whitlatch,
Stephanie Worthington,
Carlos Yero,
Benedikt Zihlmann
Abstract:
The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the le…
▽ More
The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
Lambert W function and hanging chain revisited
Authors:
Masato Ito
Abstract:
In classical physics, calculating the slack of a hanging chain is a problem that has attracted interest. This study aims to solve this problem through experiment and theory. When the length and distance of both the ends of a hanging chain are given, the length of slack can be expressed by a Lambert W function or an irrational function within a certain distance. Herein, a simple observation of the…
▽ More
In classical physics, calculating the slack of a hanging chain is a problem that has attracted interest. This study aims to solve this problem through experiment and theory. When the length and distance of both the ends of a hanging chain are given, the length of slack can be expressed by a Lambert W function or an irrational function within a certain distance. Herein, a simple observation of the slack is presented. The result obtained is one of the applications of the Lambert W function in the field of physics. Though the shape of a hanging chain is well-known to be a catenary, the calculation of slack possesses richer aspects of mathematical physics.
△ Less
Submitted 18 January, 2019; v1 submitted 19 September, 2018;
originally announced September 2018.
-
Solid deuterium surface degradation at ultracold neutron sources
Authors:
A. Anghel,
T. L. Bailey,
G. Bison,
B. Blau,
L. J. Broussard,
S. M. Clayton,
C. Cude-Woods,
M. Daum,
A. Hawari,
N. Hild,
P. Huffman,
T. M. Ito,
K. Kirch,
E. Korobkina,
B. Lauss,
K. Leung,
E. M. Lutz,
M. Makela,
G. Medlin,
C. L. Morris,
R. W. Pattie,
D. Ries,
A. Saunders,
P. Schmidt-Wellenburg,
V. Talanov
, et al. (5 additional authors not shown)
Abstract:
Solid deuterium (sD_2) is used as an efficient converter to produce ultracold neutrons (UCN). It is known that the sD_2 must be sufficiently cold, of high purity and mostly in its ortho-state in order to guarantee long lifetimes of UCN in the solid from which they are extracted into vacuum. Also the UCN transparency of the bulk sD_2 material must be high because crystal inhomogeneities limit the m…
▽ More
Solid deuterium (sD_2) is used as an efficient converter to produce ultracold neutrons (UCN). It is known that the sD_2 must be sufficiently cold, of high purity and mostly in its ortho-state in order to guarantee long lifetimes of UCN in the solid from which they are extracted into vacuum. Also the UCN transparency of the bulk sD_2 material must be high because crystal inhomogeneities limit the mean free path for elastic scattering and reduce the extraction efficiency. Observations at the UCN sources at Paul Scherrer Institute and at Los Alamos National Laboratory consistently show a decrease of the UCN yield with time of operation after initial preparation or later treatment (`conditioning') of the sD_2. We show that, in addition to the quality of the bulk sD_2, the quality of its surface is essential. Our observations and simulations support the view that the surface is deteriorating due to a build-up of D_2 frost-layers under pulsed operation which leads to strong albedo reflections of UCN and subsequent loss. We report results of UCN yield measurements, temperature and pressure behavior of deuterium during source operation and conditioning, and UCN transport simulations. This, together with optical observations of sD_2 frost formation on initially transparent sD_2 in offline studies with pulsed heat input at the North Carolina State University UCN source results in a consistent description of the UCN yield decrease.
△ Less
Submitted 28 August, 2018; v1 submitted 23 April, 2018;
originally announced April 2018.
-
Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$
Authors:
X. Sun,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu
, et al. (35 additional authors not shown)
Abstract:
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) exper…
▽ More
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.
△ Less
Submitted 28 March, 2018;
originally announced March 2018.
-
Cavallo's Multiplier for in situ Generation of High Voltage
Authors:
Steven M. Clayton,
Takeyasu M. Ito,
John C. Ramsey,
Wanchun Wei,
Marie A. Blatnik,
Bradley W. Filippone,
George M. Seidel
Abstract:
A classic electrostatic induction machine, Cavallo's multiplier, is suggested for in situ production of very high voltage in cryogenic environments. The device is suitable for generating a large electrostatic field under conditions of very small load current. Operation of the Cavallo multiplier is analyzed, with quantitative description in terms of mutual capacitances between electrodes in the sys…
▽ More
A classic electrostatic induction machine, Cavallo's multiplier, is suggested for in situ production of very high voltage in cryogenic environments. The device is suitable for generating a large electrostatic field under conditions of very small load current. Operation of the Cavallo multiplier is analyzed, with quantitative description in terms of mutual capacitances between electrodes in the system. A demonstration apparatus was constructed, and measured voltages are compared to predictions based on measured capacitances in the system. The simplicity of the Cavallo multiplier makes it amenable to electrostatic analysis using finite element software, and electrode shapes can be optimized to take advantage of a high dielectric strength medium such as liquid helium. A design study is presented for a Cavallo multiplier in a large-scale, cryogenic experiment to measure the neutron electric dipole moment.
△ Less
Submitted 9 April, 2018; v1 submitted 20 March, 2018;
originally announced March 2018.
-
Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment
Authors:
T. M. Ito,
E. R. Adamek,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
X. Ding,
D. E. Fellers,
P. Geltenbort,
S. K. Lamoreaux,
C. Y. Liu,
S. MacDonald,
M. Makela,
C. L. Morris,
R. W. Pattie Jr.,
J. C. Ramsey,
D. J. Salvat,
A. Saunders,
E. I. Sharapov,
S. Sjue,
A. P. Sprow,
Z. Tang,
H. L. Weaver,
W. Wei
, et al. (1 additional authors not shown)
Abstract:
The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the…
▽ More
The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was $184(32)$ UCN/cm$^3$, a four-fold increase from the highest previously reported. The polarized UCN density stored in an external chamber was measured to be $39(7)$ UCN/cm$^3$, which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of $σ(d_n) = 3\times 10^{-27}$ $e\cdot$cm.
△ Less
Submitted 16 January, 2018; v1 submitted 14 October, 2017;
originally announced October 2017.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy
Authors:
Wanchun Wei,
L. J. Broussard,
M. A. Hoffbauer,
M. Makela,
C. L. Morris,
Z. Tang,
E. R. Adamek,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
K. K. Leung,
C. -Y. Liu,
D. J. Morley,
Jose D. Ortiz,
R. W. Pattie, Jr.,
J. C. Ramsey,
A. Saunders,
S. J. Seestrom
, et al. (7 additional authors not shown)
Abstract:
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neu…
▽ More
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.
△ Less
Submitted 12 May, 2016; v1 submitted 27 April, 2016;
originally announced April 2016.
-
First Results from The GlueX Experiment
Authors:
The GlueX Collaboration,
H. Al Ghoul,
E. G. Anassontzis,
F. Barbosa,
A. Barnes,
T. D. Beattie,
D. W. Bennett,
V. V. Berdnikov,
T. Black,
W. Boeglin,
W. K. Brooks,
B. Cannon,
O. Chernyshov,
E. Chudakov,
V. Crede,
M. M. Dalton,
A. Deur,
S. Dobbs,
A. Dolgolenko,
M. Dugger,
H. Egiyan,
P. Eugenio,
A. M. Foda,
J. Frye,
S. Furletov
, et al. (86 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and…
▽ More
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and $ω$ mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the $ρ$ has been observed.
△ Less
Submitted 14 January, 2016; v1 submitted 11 December, 2015;
originally announced December 2015.
-
Measurement of spin-flip probabilities for ultracold neutrons interacting with nickel phosphorus coated surfaces
Authors:
Z. Tang,
E. R. Adamek,
A. Brandt,
N. B. Callahan,
S. M. Clayton,
S. A. Currie,
T. M. Ito,
M. Makela,
Y. Masuda,
C. L. Morris,
R. Pattie Jr.,
J. C. Ramsey,
D. J. Salvat,
A. Saunders,
A. R. Young
Abstract:
We report a measurement of the spin-flip probabilities for ultracold neutrons interacting with surfaces coated with nickel phosphorus. For 50~$μ$m thick nickel phosphorus coated on stainless steel, the spin-flip probability per bounce was found to be $β_{\rm NiP\;on\;SS} = (3.3^{+1.8}_{-5.6}) \times 10^{-6}$. For 50~$μ$m thick nickel phosphorus coated on aluminum, the spin-flip probability per bou…
▽ More
We report a measurement of the spin-flip probabilities for ultracold neutrons interacting with surfaces coated with nickel phosphorus. For 50~$μ$m thick nickel phosphorus coated on stainless steel, the spin-flip probability per bounce was found to be $β_{\rm NiP\;on\;SS} = (3.3^{+1.8}_{-5.6}) \times 10^{-6}$. For 50~$μ$m thick nickel phosphorus coated on aluminum, the spin-flip probability per bounce was found to be $β_{\rm NiP\;on\;Al} = (3.6^{+2.1}_{-5.9}) \times 10^{-6}$. For the copper guide used as reference, the spin flip probability per bounce was found to be $β_{\rm Cu} = (6.7^{+5.0}_{-2.5}) \times 10^{-6}$. The results on the nickel phosphorus-coated surfaces may be interpreted as upper limits, yielding $β_{\rm NiP\;on\;SS} < 6.2 \times 10^{-6}$ (90\% C.L.) and $β_{\rm NiP\;on\;Al} < 7.0 \times 10^{-6}$ (90\% C.L.) for 50~$μ$m thick nickel phosphorus coated on stainless steel and 50~$μ$m thick nickel phosphorus coated on aluminum, respectively. Nickel phosphorus coated stainless steel or aluminum provides a solution when low-cost, mechanically robust, and non-depolarizing UCN guides with a high-Fermi-potential are needed.
△ Less
Submitted 2 April, 2016; v1 submitted 22 October, 2015;
originally announced October 2015.
-
An apparatus for studying electrical breakdown in liquid helium at 0.4 K and testing electrode materials for the SNS nEDM experiment
Authors:
T. M. Ito,
J. C. Ramsey,
W. Yao,
D. H. Beck,
V. Cianciolo,
S. M. Clayton,
C. Crawford,
S. A. Currie,
B. W. Filippone,
W. C. Griffith,
M. Makela,
R. Schmid,
G. M. Seidel,
Z. Tang,
D. Wagner,
W. Wei,
S. E. Williamson
Abstract:
We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and $\sim$600 torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of $1-2$ cm between them, and a potential up to $\pm 50$ kV can be applied to each electrode. Initial results demonstrated that i…
▽ More
We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and $\sim$600 torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of $1-2$ cm between them, and a potential up to $\pm 50$ kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures at 0.4 K. We also measured the current between two electrodes. Our initial results, $I<1$ pA at 45 kV, correspond to a lower bound on the effective volume resistivity of LHe of $ρ_V > 5\times10^{18}$ $Ω\cdot$cm. This lower bound is 5 times larger than the bound previously measured. We report the design, construction, and operational experience of the apparatus, as well as initial results.
△ Less
Submitted 2 April, 2016; v1 submitted 20 October, 2015;
originally announced October 2015.
-
Improving Charge-Collection Efficiency of Kyoto's SOI Pixel Sensors
Authors:
Hideaki Matsumura,
Takeshi Go Tsuru,
Takaaki Tanaka,
Ayaki Takeda,
Makoto Ito,
Syunichi Ohmura,
Yasuo Arai,
Koji Mori,
Yusuke Nishioka,
Ryota Takenaka,
Takayoshi Kohmura
Abstract:
We have been develo** X-ray SOIPIXs for next-generation satellites for X-ray astronomy. Their high time resolution ($\sim10~μ$s) and event-trigger-output function enable us to read out without pile-ups and to use anti-coincidence systems. Their performance in imaging spectroscopy is comparable to that in the CCDs. A problem in our previous model was degradation of charge-collection efficiency (C…
▽ More
We have been develo** X-ray SOIPIXs for next-generation satellites for X-ray astronomy. Their high time resolution ($\sim10~μ$s) and event-trigger-output function enable us to read out without pile-ups and to use anti-coincidence systems. Their performance in imaging spectroscopy is comparable to that in the CCDs. A problem in our previous model was degradation of charge-collection efficiency (CCE) at pixel borders. We measured the response in the sub-pixel scale, using finely collimated X-ray beams at $10~μ$mΦ$ at SPring-8, and investigated the non-uniformity of the CCE within a pixel. We found that the X-ray detection efficiency and CCE degrade in the sensor region under the pixel circuitry placed outside the buried p-wells (BPW). A 2D simulation of the electric fields shows that the isolated pixel-circuitry outside the BPW creates local minimums in the electric potentials at the interface between the sensor and buried oxide layers. Thus, a part of signal charge is trapped there and is not collected to the BPW. Based on this result, we modified the placement of the in-pixel circuitry so that the electric fields would converge toward the BPW. We confirmed that the CCE at pixel borders is successfully improved with the updated model.
△ Less
Submitted 1 September, 2015;
originally announced September 2015.
-
Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystal and a Micro Parallel-hole Collimator
Authors:
Joong Hyun Kim,
Mikiko Ito,
Soo Mee Kim,
Seong Jong Hong,
Jae Sung Lee
Abstract:
The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact size, low-cost and reasonable performance through Monte Carlo simulation. L0.9GSO crystals with surface area of 50 mm X 50 mm were investigated for the design optim…
▽ More
The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact size, low-cost and reasonable performance through Monte Carlo simulation. L0.9GSO crystals with surface area of 50 mm X 50 mm were investigated for the design optimization. The intrinsic detection efficiency, intrinsic spatial resolution, and intrinsic energy resolution of crystals were estimated for different crystal thicknesses and photon energies (using I-125 and Tc-99m sources). Two kinds of surface treatments (providing polished and rough surfaces) were compared by optical photon simulation. The standard deviation of the angle between a micro-facet and the mean surface was set to 0.1 and 6.0 for polished and rough surfaces, respectively. For comparison, the intrinsic performance of NaI(Tl) was also investigated. A multi-photomultiplier tube was designed with 16 X 16 anode pixels having size of 2.8 mm X 2.8 mm and pitch of 3.04 mm, and a 1.5 mm thickness glass window. The length of the micro collimator was also optimized. Finally, the performance of the SPECT system was assessed and an ultra-micro hot spot phantom image was obtained in simulation. The 1-mm-thick LGSO was sufficient to detect most incident photons from I-125 but a thickness of 3 mm was required for Tc-99m imaging. Polished crystal yielded better intrinsic spatial resolution (~540 μm) and lower light output than rough crystal. Energy resolutions of I-125 and Tc-99m were ~36.9% and ~19.1%. With the optimized collimator length, spatial resolution of ~1 mm and sensitivity of ~100 cps/MBq were achieved with a four-head SPECT system. A hot rod with a diameter of 1.0 mm was resolved in the SPECT image of ultra-micro hot spot phantom.
△ Less
Submitted 11 March, 2015;
originally announced March 2015.
-
A multilayer surface detector for ultracold neutrons
Authors:
Zhehui Wang,
M. A. Hoffbauer,
C. L. Morris,
N. B. Callahan,
E. R. Adamek,
J. D. Bacon,
M. Blatnik,
A. E. Brandt,
L. J. Broussard,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
J. Gao,
F. E. Gray,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
M. Makela,
J. C. Ramsey,
R. W. Pattie, Jr.,
D. J. Salvat,
A. Saunders
, et al. (11 additional authors not shown)
Abstract:
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escap…
▽ More
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick $^{10}$B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials and others. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.
△ Less
Submitted 24 April, 2015; v1 submitted 11 March, 2015;
originally announced March 2015.
-
A study of decays to strange final states with GlueX in Hall D using components of the BaBar DIRC
Authors:
The GlueX Collaboration,
M. Dugger,
B. Ritchie,
I. Senderovich,
E. Anassontzis,
P. Ioannou,
C. Kourkoumeli,
G. Vasileiadis,
G. Voulgaris,
N. Jarvis,
W. Levine,
P. Mattione,
W. McGinley,
C. A. Meyer,
R. Schumacher,
M. Staib,
F. Klein,
D. Sober,
N. Sparks,
N. Walford,
D. Doughty,
A. Barnes,
R. Jones,
J. McIntyre,
F. Mokaya
, et al. (82 additional authors not shown)
Abstract:
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studi…
▽ More
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studies of kaon final states are essential for inferring the quark flavor content of hybrid and conventional mesons. The GlueX FDIRC would reuse one-third of the synthetic fused silica bars that were utilized in the BaBar DIRC. A new focussing photon camera, read out with large area photodetectors, would be developed. We propose operating the enhanced GlueX detector in Hall D for a total of 220 days at an average intensity of 5x10^7 γ/s, a program that was conditionally approved by PAC39
△ Less
Submitted 1 August, 2014;
originally announced August 2014.
-
High Voltage in Noble Liquids for High Energy Physics
Authors:
Edited by B. Rebel,
C. Hall with contributions from E. Bernard,
C. H. Faham,
T. M. Ito,
B. Lundberg,
M. Messina,
F. Monrabal,
S. P. Pereverzev,
F. Resnati,
P. C. Rowson,
M. Soderberg,
T. Strauss,
A. Tomas,
J. Va'vra,
H. Wang
Abstract:
A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at develo** high voltage…
▽ More
A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at develo** high voltage systems in noble liquids.
△ Less
Submitted 18 March, 2014; v1 submitted 14 March, 2014;
originally announced March 2014.
-
High electric field development for the SNS nEDM Experiment
Authors:
T. M. Ito,
D. H. Beck,
S. M. Clayton,
C. Crawford,
S. A. Currie,
W. C. Griffith,
J. C. Ramsey,
A. L. Roberts,
R. Schmid,
G. M. Seidel,
D. Wagner,
W. Yao
Abstract:
A new experiment to search for the permanent electric dipole moment of the neutron is being developed for installation at the Spallation Neutron Source at Oak Ridge National Laboratory. This experiment will be performed in liquid helium at ? 0:4 K and requires a large electric field (E ~ 75 kV/cm) to be applied in liquid helium. We have constructed a new HV test apparatus to study electric breakdo…
▽ More
A new experiment to search for the permanent electric dipole moment of the neutron is being developed for installation at the Spallation Neutron Source at Oak Ridge National Laboratory. This experiment will be performed in liquid helium at ? 0:4 K and requires a large electric field (E ~ 75 kV/cm) to be applied in liquid helium. We have constructed a new HV test apparatus to study electric breakdown in liquid helium. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes12 cm in diameter for a wide range of pressures.
△ Less
Submitted 21 January, 2014;
originally announced January 2014.
-
Charge Distribution about an Ionizing Electron Track in Liquid Helium
Authors:
G. M. Seidel,
T. M. Ito,
A. Ghosh,
B. Sethumadhavan
Abstract:
The dependence on an applied electric field of the ionization current produced by an energetic electron stopped in liquid helium can be used to determine the spatial distribution of secondary electrons with respect to their geminate partners. An analytic expression relating the current and distribution is derived. The distribution is found to be non-Gaussian with a long tail at larger distances.
The dependence on an applied electric field of the ionization current produced by an energetic electron stopped in liquid helium can be used to determine the spatial distribution of secondary electrons with respect to their geminate partners. An analytic expression relating the current and distribution is derived. The distribution is found to be non-Gaussian with a long tail at larger distances.
△ Less
Submitted 29 January, 2014; v1 submitted 4 October, 2013;
originally announced October 2013.
-
Characterization of protonated and deuterated Tetra-Phenyl Butadiene Film in a Polystyrene Matrix
Authors:
V. M. Gehman,
T. M. Ito,
W. C. Griffith,
S. R. Seibert
Abstract:
We study the effect of deuteration and annealing on the fluorescence spectrum shape and VUV to visible conversion efficiency of TPB films in a polystyrene matrix with input light from 120 to 220 nm. We observed no discernible difference in the fluorescence spectrum shape between any of the films. The deuterated film performed equally well compared to the standard one in terms of conversion efficie…
▽ More
We study the effect of deuteration and annealing on the fluorescence spectrum shape and VUV to visible conversion efficiency of TPB films in a polystyrene matrix with input light from 120 to 220 nm. We observed no discernible difference in the fluorescence spectrum shape between any of the films. The deuterated film performed equally well compared to the standard one in terms of conversion efficiency, but annealing seems to degrade this efficiency to roughly 75% of its non annealed value at all wavelengths studied.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
Time dependent spin-dressing using a $^3$He atomic beam
Authors:
S. Eckel,
S. K. Lamoreaux,
M. E. Hayden,
T. M. Ito
Abstract:
We have performed high precision experimental measurements of spin precession using a dressed $^3$He atomic beam. Spin-dressing uses an oscillating magnetic field detuned to high frequency which is orthogonal to a static magnetic field to effectively change the gyromagnetic ratio of a spin. We verify the validity of the spin-dressing Hamiltonian in regions beyond the limiting solution in which the…
▽ More
We have performed high precision experimental measurements of spin precession using a dressed $^3$He atomic beam. Spin-dressing uses an oscillating magnetic field detuned to high frequency which is orthogonal to a static magnetic field to effectively change the gyromagnetic ratio of a spin. We verify the validity of the spin-dressing Hamiltonian in regions beyond the limiting solution in which the Larmor frequency is much smaller than the frequency of the dressing field. We also evaluate the effect of magnetic field misalignment, e.g. if the oscillating magnetic field is not orthogonal to the static magnetic field. Modulation of the dressing field parameters is also discussed, with a focus on whether such a modulation can be approximated merely as a time dependent, dressed gyromagnetic ratio. Furthermore, we discuss implications for a proposed search for the neutron electric dipole moment, which would employ spin-dressing to make the effective $^3$He and neutron magnetic moments equal.
△ Less
Submitted 24 August, 2012;
originally announced August 2012.
-
Formation and Classification of Amorphous Carbon by Molecular Dynamics Simulation
Authors:
Atsushi M. Ito,
Arimichi Takayama,
Seiki Saito,
Hiroaki Nakamura
Abstract:
By using molecular dynamics simulation, formation mechanisms of amorphous carbon in particular sp${}^3$ rich structure was researched. The problem that reactive empirical bond order potential cannot represent amorphous carbon properly was cleared in the transition process from graphite to diamond by high pressure and the deposition process of amorphous carbon thin films. Moreover, the new potentia…
▽ More
By using molecular dynamics simulation, formation mechanisms of amorphous carbon in particular sp${}^3$ rich structure was researched. The problem that reactive empirical bond order potential cannot represent amorphous carbon properly was cleared in the transition process from graphite to diamond by high pressure and the deposition process of amorphous carbon thin films. Moreover, the new potential model which is based on electron distribution simplified as a point charge was developed by using downfolding method. As a result, the molecular dynamics simulation with the new potential could demonstrate the transition from graphite to diamond at the pressure of 15 GPa corresponding to experiment and the deposition of sp${}^3$ rich amorphous carbon.
△ Less
Submitted 4 July, 2012;
originally announced July 2012.
-
Real-time In Situ Electron Spin Resonance Measurements on Fungal Spores of Penicillium digitatum during Exposure of Oxygen Plasmas
Authors:
Kenji Ishikawa,
Hiroko Moriyama,
Hiromasa Tanaka,
Kazuhiro Tamiya,
Hiroshi Hashizume,
Takayuki Ohta,
Masafumi Ito,
Sachiko Iseki,
Keigo Takeda,
Hiroki Kondo,
Makoto Sekine,
Masaru Hori
Abstract:
We report the kinetic analysis of free radicals on fungal spores of Penicillium digitatum interacted with atomic oxygen generated plasma electric discharge using real time in situ electron spin resonance (ESR) measurements. We have obtained information that the ESR signal from the spores was observed and preliminarily assignable to semiquinone radical with a g-value of around 2.004 and a line widt…
▽ More
We report the kinetic analysis of free radicals on fungal spores of Penicillium digitatum interacted with atomic oxygen generated plasma electric discharge using real time in situ electron spin resonance (ESR) measurements. We have obtained information that the ESR signal from the spores was observed and preliminarily assignable to semiquinone radical with a g-value of around 2.004 and a line width of approximately 5G. The decay of the signal is possibly linked to the inactivation of the fungal spore. The real-time in situ ESR has proven to be a useful method to elucidate plasma-induced surface reactions on biological specimens.
△ Less
Submitted 28 June, 2012;
originally announced June 2012.
-
Effect of an electric field on superfluid helium scintillation produced by alpha-particle sources
Authors:
T. M. Ito,
S. M. Clayton,
J. Ramsey,
M. Karcz,
C. -Y. Liu,
J. C. Long,
T. G. Reddy,
G. M. Seidel
Abstract:
We report a study of the intensity and time dependence of scintillation produced by weak alpha particle sources in superfluid helium in the presence of an electric field (0 - 45 kV/cm) in the temperature range of 0.2 K to 1.1 K at the saturated vapor pressure. Both the prompt and the delayed components of the scintillation exhibit a reduction in intensity with the application of an electric field.…
▽ More
We report a study of the intensity and time dependence of scintillation produced by weak alpha particle sources in superfluid helium in the presence of an electric field (0 - 45 kV/cm) in the temperature range of 0.2 K to 1.1 K at the saturated vapor pressure. Both the prompt and the delayed components of the scintillation exhibit a reduction in intensity with the application of an electric field. The reduction in the intensity of the prompt component is well approximated by a linear dependence on the electric field strength with a reduction of 15% at 45 kV/cm. When analyzed using the Kramers theory of columnar recombination, this electric field dependence leads to the conclusion that roughly 40% of the scintillation results from species formed from atoms originally promoted to excited states and 60% from excimers created by ionization and subsequent recombination with the charges initially having a cylindrical Gaussian distribution about the alpha track of 60 nm radius. The intensity of the delayed component of the scintillation has a stronger dependence on the electric field strength and on temperature. The implications of these data on the mechanisms affecting scintillation in liquid helium are discussed.
△ Less
Submitted 6 April, 2012; v1 submitted 3 October, 2011;
originally announced October 2011.
-
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
Authors:
G0 Collaboration,
D. Androic,
D. S. Armstrong,
J. Arvieux,
R. Asaturyan,
T. D. Averett,
S. L. Bailey,
G. Batigne,
D. H. Beck,
E. J. Beise,
J. Benesch,
F. Benmokhtar,
L. Bimbot,
J. Birchall,
A. Biselli,
P. Bosted,
H. Breuer,
P. Brindza,
C. L. Capuano,
R. D. Carlini,
R. Carr,
N. Chant,
Y. -C. Chao,
R. Clark,
A. Coppens
, et al. (105 additional authors not shown)
Abstract:
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized bea…
▽ More
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
△ Less
Submitted 3 March, 2011;
originally announced March 2011.
-
Hybrid Simulation between Molecular Dynamics and Binary Collision Approximation Codes for Hydrogen injection onto Carbon Materials
Authors:
Seiki Saito,
Atsushi M. Ito,
Arimichi Takayama,
Takahiro Kenmotsu,
Hiroaki Nakamura
Abstract:
Molecular dynamics (MD) simulation with modified Brenner's reactive empirical bond order (REBO) potential is a powerful tool to investigate plasma wall interaction on divertor plates in a nuclear fusion device. However, MD simulation box's size is less than several nm for the performance of a computer. To extend the size of the MD simulation, we develop a hybrid simulation code between MD code usi…
▽ More
Molecular dynamics (MD) simulation with modified Brenner's reactive empirical bond order (REBO) potential is a powerful tool to investigate plasma wall interaction on divertor plates in a nuclear fusion device. However, MD simulation box's size is less than several nm for the performance of a computer. To extend the size of the MD simulation, we develop a hybrid simulation code between MD code using REBO potential and binary collision approximation (BCA) code. Using the BCA code instead of computing all particles with a high kinetic energy for every step in the MD simulation, considerable computation time is saved. By demonstrating a hydrogen atom injection on a graphite by the hybrid simulation code, it is found that the hybrid simulation code works efficiently in a large simulation box.
△ Less
Submitted 25 June, 2010; v1 submitted 23 June, 2010;
originally announced June 2010.
-
Precision timing measurement of phototube pulses using a flash analog-to-digital converter
Authors:
J. V. Bennett,
M. Kornicer,
M. R. Shepherd,
M. M. Ito
Abstract:
We present the timing characteristics of the flash ADC readout of the GlueX forward calorimeter, which depends on precise measurement of arrival time of pulses from FEU 84-3 photomultiplier tubes to suppress backgrounds. The tests presented were performed using two different 250 MHz prototype flash ADC devices, one with eight-bit and one with twelve-bit sampling depth. All measured time resolution…
▽ More
We present the timing characteristics of the flash ADC readout of the GlueX forward calorimeter, which depends on precise measurement of arrival time of pulses from FEU 84-3 photomultiplier tubes to suppress backgrounds. The tests presented were performed using two different 250 MHz prototype flash ADC devices, one with eight-bit and one with twelve-bit sampling depth. All measured time resolutions were better than 1 ns, independent of signal size, which is the design goal for the GlueX forward calorimeter. For pulses with an amplitude of 100 mV the timing resolution is 0.57 +- 0.18 ns, while for 500 mV pulses it is 0.24 +- 0.08 ns.
△ Less
Submitted 28 May, 2010;
originally announced May 2010.
-
Extension of the simulation code ACAT to treat real atomic positions
Authors:
Arimichi Takayama,
Seiki Saito,
Atsushi M. Ito,
Takahiro Kenmotsu,
Hiroaki Nakamura
Abstract:
We have investigated plasma-surface interactions with molecular dynamics (MD) simulations. It, however, is high cost computation and is limited to simulations for materials of nanometer order. In order to overcome the limitation, a complementary model based on binary collision approximation (BCA) can be established. We employed a BCA-based simulation code ACAT and extended to handle any structure…
▽ More
We have investigated plasma-surface interactions with molecular dynamics (MD) simulations. It, however, is high cost computation and is limited to simulations for materials of nanometer order. In order to overcome the limitation, a complementary model based on binary collision approximation (BCA) can be established. We employed a BCA-based simulation code ACAT and extended to handle any structure involving crystalline and amorphous. The extended code, named "ACaT", stores all positions of projectile and target atoms and velocities of recoil atoms, so it can be combined with the MD code. It also holds the potential to reproduce channeling phenomena. Thus it is expected to be useful for evaluation of channeling effects.
△ Less
Submitted 18 May, 2010;
originally announced May 2010.
-
In-situ observation of a soap film catenoid - a simple educational physics experiment
Authors:
Masato Ito,
Taku Sato
Abstract:
The solution to the Euler-Lagrange equation is an extremal functional.To understand that the functional is stationary at local extrema (maxima or minima), we propose a physics experiment that involves using soap film to form a catenoid.
A catenoid is a surface that is formed between two coaxial circular rings and is classified mathematically as a minimal surface.Using soap film, we create cate…
▽ More
The solution to the Euler-Lagrange equation is an extremal functional.To understand that the functional is stationary at local extrema (maxima or minima), we propose a physics experiment that involves using soap film to form a catenoid.
A catenoid is a surface that is formed between two coaxial circular rings and is classified mathematically as a minimal surface.Using soap film, we create catenoids between two rings and characterize the catenoid in-situ while varying distance between rings. The shape of the soap film is very interesting and can be explained using dynamic mechanics. By observing catenoid, physics students can observe local extrema phenomena.
We stress that in-situ observation of soap film catenoids is an appropriate physics experiment that combines theory and experimentation.
△ Less
Submitted 21 December, 2009; v1 submitted 20 November, 2007;
originally announced November 2007.
-
A Multiwire Proportional Chamber for Precision Studies of Neutron Beta Decay Angular Correlations
Authors:
T. M. Ito,
R. Carr,
B. W. Filippone,
J. W. Martin,
B. Plaster,
G. Rybka,
J. Yuan
Abstract:
A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron beta decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the po…
▽ More
A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron beta decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the position resolution were studied.
△ Less
Submitted 10 February, 2007;
originally announced February 2007.
-
Optimization of the Ballistic Guide Design for the SNS FNPB 8.9 A Neutron Line
Authors:
Takeyasu M. Ito,
Christopher B. Crawford,
Geoffrey L. Greene
Abstract:
The optimization of the ballistic guide design for the SNS Fundamental Neutron Physics Beamline 8.9 A line is described. With a careful tuning of the shape of the curve for the tapered section and the width of the straight section, this optimization resulted in more than 75% increase in the neutron flux exiting the 33 m long guide over a straight m=3.5 guide with the same length.
The optimization of the ballistic guide design for the SNS Fundamental Neutron Physics Beamline 8.9 A line is described. With a careful tuning of the shape of the curve for the tapered section and the width of the straight section, this optimization resulted in more than 75% increase in the neutron flux exiting the 33 m long guide over a straight m=3.5 guide with the same length.
△ Less
Submitted 27 April, 2006; v1 submitted 24 April, 2006;
originally announced April 2006.