Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays
Authors:
T. Okumura,
T. Azuma,
D. A. Bennett,
W. B. Doriese,
M. S. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
Y. Ichinohe,
P. Indelicato,
T. Isobe,
S. Kanda,
D. Kato,
M. Katsuragawa,
N. Kawamura,
Y. Kino,
N. Kominato,
Y. Miyake,
K. M. Morgan,
H. Noda,
G. C. O'Neil,
S. Okada,
K. Okutsu,
N. Paul
, et al. (18 additional authors not shown)
Abstract:
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms w…
▽ More
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Silicon tracker array for RIB experiments at SAMURAI
Authors:
A. I. Stefanescu,
V. Panin,
L. Trache,
T. Motobayashi,
H. Otsu,
A. Saastamoinen,
T. Uesaka,
L. Stuhl,
J. Tanaka,
D. Tudor,
I. C. Stefanescu,
A. E. Spiridon,
K. Yoneda,
H. Baba,
M. Kurokawa,
Y. Togano,
Z. Halasz,
M. Sasano,
S. Ota,
Y. Kubota,
D. S. Ahn,
T. Kobayashi,
Z. Elekes,
N. Fukuda,
H. Takeda
, et al. (27 additional authors not shown)
Abstract:
This work describes a silicon tracker system developed for experiments with proton-rich radioactive ion beams at the SAMURAI superconducting spectrometer of RIBF at RIKEN. The system is designed for accurate angular reconstruction and atomic number identification of relativistic heavy ions and protons which are simultaneously produced in reactions motivated by studies of proton capture reactions o…
▽ More
This work describes a silicon tracker system developed for experiments with proton-rich radioactive ion beams at the SAMURAI superconducting spectrometer of RIBF at RIKEN. The system is designed for accurate angular reconstruction and atomic number identification of relativistic heavy ions and protons which are simultaneously produced in reactions motivated by studies of proton capture reactions of interest for nuclear astrophysics. The technical characteristics of the tracking array are described in detail as are its performance in two pilot experiments. The physics justification for such a system is also presented.
△ Less
Submitted 13 July, 2023;
originally announced July 2023.
-
Performance of prototype Dual Gain Multilayer Thick GEM with high-intensity heavy-ion beam injections in low-pressure hydrogen gas
Authors:
Chihiro Iwamoto,
Shinsuke Ota,
Reiko Kojima,
Hiroshi Tokieda,
Seiya Hayakawa,
Yutaka Mizoi,
Taku Gunji,
Hidetoshi Yamaguchi,
Nobuaki Imai,
Masanori Dozono,
Ryo Nakajima,
Olga Beliuskina,
Shin'ichiro Michimasa,
Rin Yokoyama,
Keita Kawata,
Daisuke Suzuki,
Tadaaki Isobe,
Juzo Zenihiro,
Yohei Matsuda,
Jun Okamoto,
Tetsuya Murakami,
Eiichi Takada
Abstract:
A prototype Dual Gain Multilayer Thick Gas Electron Multilyer (DG-M-THGEM) with an active area of 10 cm $\times$ 10 cm was manufactured aiming at the production of a large-volume active-target time projection chamber which can work under the condition of high-intensity heavy-ion beam injections. The DG-M-THGEM has a alternating structure of electrodes and insulators. Effective gas gains of two reg…
▽ More
A prototype Dual Gain Multilayer Thick Gas Electron Multilyer (DG-M-THGEM) with an active area of 10 cm $\times$ 10 cm was manufactured aiming at the production of a large-volume active-target time projection chamber which can work under the condition of high-intensity heavy-ion beam injections. The DG-M-THGEM has a alternating structure of electrodes and insulators. Effective gas gains of two regions, which are called beam and recoil regions, are separately controlled. Performance of the prototype DG-M-THGEM in hydrogen gas at a pressure of 40 kPa was evaluated. Irradiating a $^{132}$Xe beam, an effective gas gain lower than 100 with a charge resolution of 3% was achieved in the beam region while the effective gas gain of 2000 was maintained in the recoil region. Position distributions of measured charges along the beam axis were investigated in order to evaluate gain uniformity in the high intensity beam injection. The gain shift was estimated by simulations considering space charges in the drift region. The gain shift was suppressed within 3% even at the beam intensity of 2.5 $\times$ 10$^{6}$ particles per second.
△ Less
Submitted 12 May, 2023;
originally announced May 2023.
-
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Authors:
Daikang Yan,
Joel C. Weber,
Tejas Guruswamy,
Kelsey M. Morgan,
Galen C. O'Neil,
Abigail L. Wessels,
Douglas A. Bennett,
Christine G. Pappas,
John A. Mates,
Johnathon D. Gard,
Daniel T. Becker,
Joseph W. Fowler,
Daniel S. Swetz,
Daniel R. Schmidt,
Joel N. Ullom,
Takuma Okumura,
Tadaaki Isobe,
Toshiyuki Azuma,
Shinji Okada,
Shinya Yamada,
Tadashi Hashimoto,
Orlando Quaranta,
Antonino Miceli,
Lisa M. Gades,
Umeshkumar M. Patel
, et al. (3 additional authors not shown)
Abstract:
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers…
▽ More
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
List-Mode PET Image Reconstruction Using Deep Image Prior
Authors:
Kibo Ote,
Fumio Hashimoto,
Yuya Onishi,
Takashi Isobe,
Yasuomi Ouchi
Abstract:
List-mode positron emission tomography (PET) image reconstruction is an important tool for PET scanners with many lines-of-response and additional information such as time-of-flight and depth-of-interaction. Deep learning is one possible solution to enhance the quality of PET image reconstruction. However, the application of deep learning techniques to list-mode PET image reconstruction has not be…
▽ More
List-mode positron emission tomography (PET) image reconstruction is an important tool for PET scanners with many lines-of-response and additional information such as time-of-flight and depth-of-interaction. Deep learning is one possible solution to enhance the quality of PET image reconstruction. However, the application of deep learning techniques to list-mode PET image reconstruction has not been progressed because list data is a sequence of bit codes and unsuitable for processing by convolutional neural networks (CNN). In this study, we propose a novel list-mode PET image reconstruction method using an unsupervised CNN called deep image prior (DIP) which is the first trial to integrate list-mode PET image reconstruction and CNN. The proposed list-mode DIP reconstruction (LM-DIPRecon) method alternatively iterates the regularized list-mode dynamic row action maximum likelihood algorithm (LM-DRAMA) and magnetic resonance imaging conditioned DIP (MR-DIP) using an alternating direction method of multipliers. We evaluated LM-DIPRecon using both simulation and clinical data, and it achieved sharper images and better tradeoff curves between contrast and noise than the LM-DRAMA, MR-DIP and sinogram-based DIPRecon methods. These results indicated that the LM-DIPRecon is useful for quantitative PET imaging with limited events while kee** accurate raw data information. In addition, as list data has finer temporal information than dynamic sinograms, list-mode deep image prior reconstruction is expected to be useful for 4D PET imaging and motion correction.
△ Less
Submitted 4 November, 2022; v1 submitted 28 April, 2022;
originally announced April 2022.
-
Applying machine learning to determine impact parameter in nuclear physics experiments
Authors:
C. Y. Tsang,
Yongjia Wang,
M. B. Tsang,
J. Estee,
T. Isobe,
M. Kaneko,
M. Kurata-Nishimura,
J. W. Lee,
Fupeng Li,
Qingfeng Li,
W. G. Lynch,
T. Murakami,
R. Wang,
Dan Cozma,
Rohit Kumar,
Akira Ono,
Ying-Xun Zhang
Abstract:
Machine Learning (ML) algorithms have been demonstrated to be capable of predicting impact parameter in heavy-ion collisions from transport model simulation events with perfect detector response. We extend the scope of ML application to experimental data by incorporating realistic detector response of the S$π$RIT Time Projection Chamber into the heavy-ion simulation events generated from the UrQMD…
▽ More
Machine Learning (ML) algorithms have been demonstrated to be capable of predicting impact parameter in heavy-ion collisions from transport model simulation events with perfect detector response. We extend the scope of ML application to experimental data by incorporating realistic detector response of the S$π$RIT Time Projection Chamber into the heavy-ion simulation events generated from the UrQMD model to resemble experimental data. At 3 fm, the predicted impact parameter is 2.8 fm if simulation events with perfect detector is used for training and testing; 2.4 fm if detector response is included in the training and testing, and 5.8 fm if ML algorithms trained with perfect detector is applied to testing data that has included detector response. The last result is not acceptable illustrating the importance of including the detector response in develo** the ML training algorithm. We also test the model dependence by applying the algorithms trained on UrQMD model to simulated events from four different transport models as well as using different input parameters on UrQMD model. Using data from Sn+Sn collisions at E/A=270 MeV, the ML determined impact parameters agree well with the experimentally determined impact parameter using multiplicities, except in the very central and very peripheral regions. ML selects central collision events better and allows impact parameters determination beyond the sharp cutoff limit imposed by experimental methods.
△ Less
Submitted 26 July, 2021;
originally announced July 2021.
-
Topological band theory of a generalized eigenvalue problem with Hermitian matrices: Symmetry-protected exceptional rings with emergent symmetry
Authors:
Takuma Isobe,
Tsuneya Yoshida,
Yasuhiro Hatsugai
Abstract:
So far, topological band theory is discussed mainly for systems described by eigenvalue problems. Here, we develop a topological band theory described by a generalized eigenvalue problem (GEVP). Our analysis elucidates that non-Hermitian topological band structures may emerge for systems described by a GEVP with Hermitian matrices. The above result is verified by analyzing a two-dimensional toy mo…
▽ More
So far, topological band theory is discussed mainly for systems described by eigenvalue problems. Here, we develop a topological band theory described by a generalized eigenvalue problem (GEVP). Our analysis elucidates that non-Hermitian topological band structures may emerge for systems described by a GEVP with Hermitian matrices. The above result is verified by analyzing a two-dimensional toy model where symmetry-protected exceptional rings (SPERs) emerge although the matrices involved are Hermitian. Remarkably, these SPERs are protected by emergent symmetry, which is unique to the systems described by the GEVP. Furthermore, these SPERs elucidate the origin of the characteristic dispersion of hyperbolic metamaterials which is observed in experiments.
△ Less
Submitted 9 September, 2021; v1 submitted 4 May, 2021;
originally announced May 2021.
-
The S$π$RIT Time Projection Chamber
Authors:
J. Barney,
J. Estee,
W. G. Lynch,
T. Isobe,
G. Jhang,
M. Kurata-Nishimura,
A. B. McIntosh,
T. Murakami,
R. Shane,
S. Tangwancharoen,
M. B. Tsang,
G. Cerizza,
M. Kaneko,
J. W. Lee,
C. Y. Tsang,
R. Wang,
C. Anderson,
H. Baba,
Z. Chajecki,
M. Famiano,
R. Hodges-Showalter,
B. Hong,
T. Kobayashi,
P. Lasko,
J. Łukasik
, et al. (15 additional authors not shown)
Abstract:
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096…
▽ More
The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$π$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$π$RIT TPC has a 50.5 cm drift length and an 86.4 cm $\times$ 134.4 cm pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs readout electronics. The S$π$RIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Details of the S$π$RIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and experimental data.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.
-
Charged particle track reconstruction with S$π$RIT Time Projection Chamber
Authors:
J. W. Lee,
G. Jhang,
G. Cerizza,
J. Barney,
J. Estee,
T. Isobe,
M. Kaneko,
M. Kurata-Nishimura,
W. G. Lynch,
T. Murakami,
C. Y. Tsang,
M. B. Tsang,
R. Wang,
B. Hong,
A. B. McIntosh,
H. Sakurai,
C. Santamaria,
R. Shane,
S. Tangwancharoen,
S. J. Yennello,
Y. Zhang
Abstract:
In this paper, we present a software framework, S$π$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$π$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overla…
▽ More
In this paper, we present a software framework, S$π$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$π$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlap** pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from $^{132}$Sn + $^{124}$Sn collision events with beam energy of 270 AMeV. Particle identification is established using $\left<dE/dx\right>$ and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.
△ Less
Submitted 10 January, 2020;
originally announced January 2020.
-
Space Charge Effects in the S$π$RIT Time Projection Chamber
Authors:
C. Y. Tsang,
J. Estee,
R. Wang,
J. Barney,
G. Jhang,
W. G. Lynch,
Z. Q. Zhang,
G. Cerizza,
T. Isobe,
M. Kaneko,
M. Kurata-Nishimura,
J. W. Lee,
T. Murakami,
M. B. Tsang,
S$π$RIT collaboration
Abstract:
Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configuration, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from t…
▽ More
Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configuration, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from the ionization of the detector gas by the beam creates the main source of space charge, distorting the nominal electric field of the TPC. This has a profound effect on the accuracy of the measured momenta of the emitted particles. In this paper we will discuss the magnitude of the effects and construct an observable more appropriate for fixed target experiments to study the effects. We also will present an algorithm for correcting the space charge and some of the implications it has on the momentum determination.
△ Less
Submitted 29 January, 2020; v1 submitted 23 December, 2019;
originally announced December 2019.
-
Commissioning of the BRIKEN detector for the measurement of very exotic beta-delayed neutron emitters
Authors:
A. Tolosa-Delgado,
J. Agramunt,
J. L. Tain,
A. Algora,
C. Domingo-Pardo,
A. I. Morales,
B. Rubio,
A. Tarifeno-Saldivia,
F. Calvino,
G. Cortes,
N. T. Brewer,
B. C. Rasco,
K. P. Rykaczewski,
D. W. Stracener,
J. M. Allmond,
R. Grzywacz,
R. Yokoyama,
M. Singh,
T. King,
M. Madurga,
S. Nishimura,
V. H. Phong,
S. Go,
J. Liu,
K. Matsui
, et al. (41 additional authors not shown)
Abstract:
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demo…
▽ More
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and beta-delayed neutron emission probabilities. The methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.
△ Less
Submitted 2 August, 2018;
originally announced August 2018.
-
A Gating Grid Driver for Time Projection Chambers
Authors:
S. Tangwancharoen,
W. G. Lynch,
J. Barney,
J. Estee,
R. Shane,
M. B. Tsang,
Y. Zhang,
T. Isobe,
M. Kurata-Nishimura,
T. Murakami,
Z. G. Xiao,
Y. F. Zhang
Abstract:
A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wir…
▽ More
A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wires. When the grid is closed, the wires have alternating higher and lower voltages causing the drift electrons to terminate at the more positive wires. Rapid opening of the gating grid with low pickup noise is achieved by quickly shorting the positive and negative wires to attain the average bias potential with N-type and P-type MOSFET switches. The circuit analysis and simulation software SPICE shows that the driver restores the gating grid voltage to 90% of the opening voltage in less than 0.20 $μ$s. When tested in the experimental environment of a time projection chamber larger termination resistors were chosen so that the driver opens the gating grid in 0.35 $μ$s. In each case, opening time is basically characterized by the RC constant given by the resistance of the switches and terminating resistors and the capacitance of the gating grid and its transmission line. By adding a second pair of N-type and P-type MOSFET switches, the gating grid is closed by restoring 99% of the original charges to the wires within 3 $μ$s.
△ Less
Submitted 20 December, 2016;
originally announced December 2016.
-
KATANA - a charge-sensitive triggering system for the S$π$RIT experiment
Authors:
P. Lasko,
M. Adamczyk,
J. Brzychczyk,
P. Hirnyk,
J. Łukasik,
P. Pawłowski,
K. Pelczar,
A. Snoch,
A. Sochocka,
Z. Sosin,
J. Barney,
G. Cerizza,
J. Estee,
T. Isobe,
G. Jhang,
M. Kaneko,
M. Kurata-Nishimura,
W. G. Lynch,
T. Murakami,
C. Santamaria,
M. B. Tsang,
Y. Zhang
Abstract:
KATANA - the Krakow Array for Triggering with Amplitude discrimiNAtion - has been built and used as a trigger and veto detector for the S$π$RIT TPC at RIKEN. Its construction allows operating in magnetic field and providing fast response for ionizing particles, giving the approximate forward multiplicity and charge information. Depending on this information, trigger and veto signals are generated.…
▽ More
KATANA - the Krakow Array for Triggering with Amplitude discrimiNAtion - has been built and used as a trigger and veto detector for the S$π$RIT TPC at RIKEN. Its construction allows operating in magnetic field and providing fast response for ionizing particles, giving the approximate forward multiplicity and charge information. Depending on this information, trigger and veto signals are generated. The article presents performance of the detector and details of its construction. A simple phenomenological parametrization of the number of emitted scintillation photons in plastic scintillator is proposed. The effect of the light output deterioration in the plastic scintillator due to the in-beam irradiation is discussed.
△ Less
Submitted 13 January, 2017; v1 submitted 21 October, 2016;
originally announced October 2016.
-
S$π$RIT: A time-projection chamber for symmetry-energy studies
Authors:
R. Shane,
A. McIntosh,
T. Isobe,
W. G. Lynch,
H. Baba,
J. Barney,
Z. Chajecki,
M. Chartier,
J. Estee,
M. Famiano,
B. Hong,
K. Ieki,
G. Jhang,
R. Lemmon,
F. Lu,
T. Murakami,
N. Nakatsuka,
M. Nishimura,
R. Olsen,
W. Powell,
H. Sakurai,
A. Taketani,
S. Tangwancharoen,
M. B. Tsang,
T. Usukura
, et al. (3 additional authors not shown)
Abstract:
A Time-Projection Chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (S$π$RIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equation of State (EoS). The S$π$RIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN t…
▽ More
A Time-Projection Chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (S$π$RIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equation of State (EoS). The S$π$RIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN to measure yield ratios for pions and other light isospin multiplets produced in central collisions of neutron-rich heavy ions, such as $^{132}$Sn + $^{124}$Sn. The S$π$RIT TPC can function both as a TPC detector and as an active target. It has a vertical drift length of 50 cm, parallel to the magnetic field. Gas multiplication is achieved through the use of a multi-wire anode. Image charges are produced in the 12096 pads, and are read out with the recently developed Generic Electronics for TPCs.
△ Less
Submitted 22 September, 2014;
originally announced September 2014.
-
Development of a Time Projection Chamber Using Gas Electron Multipliers (GEM-TPC)
Authors:
S. X. Oda,
H. Hamagaki,
K. Ozawa,
M. Inuzuka,
T. Sakaguchi,
T. Isobe,
T. Gunji,
Y. Morino,
S. Saito,
Y. L. Yamaguchi,
S. Sawada,
S. Yokkaichi
Abstract:
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%), Ar(70%)-C2H6(30%) and CF4). Detection efficiency of 99%, and spatial resolution of 79 $μ$m in the pad-row direction and 313 $μ$m in the drift direction were achi…
▽ More
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%), Ar(70%)-C2H6(30%) and CF4). Detection efficiency of 99%, and spatial resolution of 79 $μ$m in the pad-row direction and 313 $μ$m in the drift direction were achieved. The test results show that the GEM-TPC meets the requirements for high energy heavy ion collision experiments. The configuration and performance of the GEM-TPC are described.
△ Less
Submitted 23 September, 2006; v1 submitted 26 May, 2006;
originally announced May 2006.
-
A Hadron Blind Detector for the PHENIX Experiment at RHIC
Authors:
Z. Fraenkel,
A. Kozlov,
M. Naglis,
I. Ravinovich,
L. Shekhtman,
I. Tserruya,
B. Azmoun,
C. Woody,
S. Sawada,
S. Yokkaichi,
A. Milov,
T. Gunji,
H. Hamagaki,
M. Inuzuka,
T. Isobe,
Y. Morino,
S. X. Oda,
K. Ozawa,
S. Saito,
T. Sakaguchi,
Y. Yamaguchi
Abstract:
A Hadron Blind Detector (HBD) is being developed for the PHENIX experiment at RHIC. It consists of a Cherenkov radiator operated with pure CF4 directly coupled in a windowless configuration to a triple-GEM detector element with a CsI photocathode and pad readout. The HBD operates in the bandwidth 6-11.5 eV(110-200 nm). We studied the detector response to minimum ionizing particles and to electro…
▽ More
A Hadron Blind Detector (HBD) is being developed for the PHENIX experiment at RHIC. It consists of a Cherenkov radiator operated with pure CF4 directly coupled in a windowless configuration to a triple-GEM detector element with a CsI photocathode and pad readout. The HBD operates in the bandwidth 6-11.5 eV(110-200 nm). We studied the detector response to minimum ionizing particles and to electrons. We present measurements of the CsI quantum efficiency, which are in very good agreement with previously published results over the bandwidth 6-8.3 eV and extend them up to 10.3 eV. Discharge probability andaging studies of the GEMs and the CsI photocathode in pure CF4 are presented.
△ Less
Submitted 2 February, 2005;
originally announced February 2005.