Results and Limits of Time Division Multiplexing for the BICEP Array High Frequency Receivers
Authors:
S. Fatigoni,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
D. Beck,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. J. Cukierman,
E. V. Denison,
M. I. Dierickx,
L. Duband,
M. Eiben,
J. P. Filippini,
A. Fortes,
M. Gao,
C. Giannakopoulos,
N. Goeckner-Wald,
D. C. Goldfinger
, et al. (62 additional authors not shown)
Abstract:
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the…
▽ More
Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high frequency receivers, observing at 150GHz and 220/270GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard Multi Channel Electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates Time Division Multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and crosstalk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Future experiments like CMB-S4 plan to use TES bolometers with Time Division/SQUID-based readout for an even larger number of detectors.
△ Less
Submitted 24 October, 2023; v1 submitted 16 October, 2023;
originally announced October 2023.
-
Electromagnetic modeling and science reach of DMRadio-m$^3$
Authors:
DMRadio Collaboration,
A. AlShirawi,
C. Bartram,
J. N. Benabou,
L. Brouwer,
S. Chaudhuri,
H. -M. Cho,
J. Corbin,
W. Craddock,
A. Droster,
J. W. Foster,
J. T. Fry,
P. W. Graham,
R. Henning,
K. D. Irwin,
F. Kadribasic,
Y. Kahn,
A. Keller,
R. Kolevatov,
S. Kuenstner,
N. Kurita,
A. F. Leder,
D. Li,
J. L. Ouellet,
K. M. W. Pappas
, et al. (12 additional authors not shown)
Abstract:
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10-200 MHz (41 neV$/c^2$ - 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present…
▽ More
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10-200 MHz (41 neV$/c^2$ - 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m$^3$, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of two larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30-200 MHz can be achieved with a $3σ$ live scan time of 3.7 years.
△ Less
Submitted 27 February, 2023;
originally announced February 2023.
-
Quantum metrology of low frequency electromagnetic modes with frequency upconverters
Authors:
Stephen E. Kuenstner,
Elizabeth C. van Assendelft,
Saptarshi Chaudhuri,
Hsiao-Mei Cho,
Jason Corbin,
Shawn W. Henderson,
Fedja Kadribasic,
Dale Li,
Arran Phipps,
Nicholas M. Rapidis,
Maria Simanovskaia,
Jyotirmai Singh,
Cyndia Yu,
Kent D. Irwin
Abstract:
We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode…
▽ More
We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ($\sim$ 5GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory, and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use non-classical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc--VHF electromagnetic modes as quantum sensors with sensitivity better than the Standard Quantum Limit (SQL). We demonstrate signal upconversion from low frequencies to microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of $46.9$\;dB, which is a necessary step towards the realization of full BAE.
△ Less
Submitted 12 July, 2024; v1 submitted 11 October, 2022;
originally announced October 2022.
-
SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Josef C. Frisch,
Shawn W. Henderson,
Max Silva-Feaver,
Kam Arnold,
David Brown,
Jake Connors,
Ari J. Cukierman,
J. Mitch D'Ewart,
Bradley J. Dober,
John E. Dusatko,
Gunther Haller,
Ryan Herbst,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Chao-Lin Kuo,
John A. B. Mates,
Larry Ruckman,
Joel Ullom,
Leila Vale,
Daniel D. Van Winkle,
Jesus Vasquez,
Edward Young
Abstract:
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arr…
▽ More
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. We focus in particular on the case of large channel count, low bandwidth applications, but the system has been easily reconfigured for high bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
△ Less
Submitted 22 August, 2022;
originally announced August 2022.
-
Projected Sensitivity of DMRadio-m$^3$: A Search for the QCD Axion Below $1\,μ$eV
Authors:
DMRadio Collaboration,
L. Brouwer,
S. Chaudhuri,
H. -M. Cho,
J. Corbin,
W. Craddock,
C. S. Dawson,
A. Droster,
J. W. Foster,
J. T. Fry,
P. W. Graham,
R. Henning,
K. D. Irwin,
F. Kadribasic,
Y. Kahn,
A. Keller,
R. Kolevatov,
S. Kuenstner,
A. F. Leder,
D. Li,
J. L. Ouellet,
K. Pappas,
A. Phipps,
N. M. Rapidis,
B. R. Safdi
, et al. (9 additional authors not shown)
Abstract:
The QCD axion is one of the most compelling candidates to explain the dark matter abundance of the universe. With its extremely small mass ($\ll 1\,\mathrm{eV}/c^2$), axion dark matter interacts as a classical field rather than a particle. Its coupling to photons leads to a modification of Maxwell's equations that can be measured with extremely sensitive readout circuits. DMRadio-m$^3$ is a next-g…
▽ More
The QCD axion is one of the most compelling candidates to explain the dark matter abundance of the universe. With its extremely small mass ($\ll 1\,\mathrm{eV}/c^2$), axion dark matter interacts as a classical field rather than a particle. Its coupling to photons leads to a modification of Maxwell's equations that can be measured with extremely sensitive readout circuits. DMRadio-m$^3$ is a next-generation search for axion dark matter below $1\,μ$eV using a $>4$ T static magnetic field, a coaxial inductive pickup, a tunable LC resonator, and a DC-SQUID readout. It is designed to search for QCD axion dark matter over the range $20\,\mathrm{neV}\lesssim m_ac^2\lesssim 800\,\mathrm{neV}$ ($5\,\mathrm{MHz}<ν<200\,\mathrm{MHz}$). The primary science goal aims to achieve DFSZ sensitivity above $m_ac^2\approx 120$ neV (30 MHz), with a secondary science goal of probing KSVZ axions down to $m_ac^2\approx40\,\mathrm{neV}$ (10 MHz).
△ Less
Submitted 8 December, 2022; v1 submitted 28 April, 2022;
originally announced April 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole
Authors:
L. Moncelsi,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
E. V. Denison,
M. Dierickx,
L. Duband,
M. Eiben,
S. Fatigoni,
J. P. Filippini,
N. Goeckner-Wald,
D. C. Goldfinger,
J. Grayson,
P. Grimes,
G. Hall
, et al. (50 additional authors not shown)
Abstract:
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date…
▽ More
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. BICEP Array (BA) is the Stage-3 instrument of the BK program and will comprise four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale $B$-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full BICEP Array instrument is projected to reach $σ_r$ between 0.002 and 0.004, depending on foreground complexity and degree of removal of $B$-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver.
△ Less
Submitted 7 December, 2020;
originally announced December 2020.
-
Particle response of antenna-coupled TES arrays: results from SPIDER and the lab
Authors:
B. Osherson,
J. P. Filippini,
J. Fu,
R. V. Gramillano,
R. Gualtieri,
E. C. Shaw,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
O. Dore,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
J. E. Gudmundsson,
M. Halpern,
J. Hartley,
M. Hasselfield,
G. Hilton,
W. Holmes,
V. V. Hristov
, et al. (23 additional authors not shown)
Abstract:
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers…
▽ More
Future mm-wave and sub-mm space missions will employ large arrays of multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce "glitches" in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. In this work we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences, and give a preliminary look at pulse shapes in laboratory data.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.
-
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Authors:
C. Zhang,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
H. Boenish,
E. Bullock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
M. Dierickx,
L. Duband,
S. Fatigoni,
J. P. Filippini,
G. Hall,
M. Halpern,
S. Harrison,
S. Henderson,
S. R. Hildebrandt
, et al. (44 additional authors not shown)
Abstract:
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of grav…
▽ More
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon-noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: G, Tc, Rn, Psat , and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon noise level 1.54E-17 W/sqrt(Hz).
△ Less
Submitted 12 February, 2020;
originally announced February 2020.
-
An Impedance-Modulated Code-Division Microwave SQUID Multiplexer
Authors:
C. Yu,
A. Ames,
S. Chaudhuri,
C. Dawson,
K. D. Irwin,
S. E. Kuenstner,
D. Li,
C. J. Titus
Abstract:
Large arrays of cryogenic detectors, including transition-edge sensors (TESs) or magnetic micro-calorimeters (MMCs), are needed for future experiments across a wide range of applications. Complexities in integration and cryogenic wiring have driven efforts to develop cryogenic readout technologies with large multiplexing factors while maintaining minimal readout noise. One such example is the micr…
▽ More
Large arrays of cryogenic detectors, including transition-edge sensors (TESs) or magnetic micro-calorimeters (MMCs), are needed for future experiments across a wide range of applications. Complexities in integration and cryogenic wiring have driven efforts to develop cryogenic readout technologies with large multiplexing factors while maintaining minimal readout noise. One such example is the microwave SQUID multiplexer ($μ$mux), which couples an incoming TES or magnetic calorimeter signal to a unique GHz-frequency resonance that is modulated in frequency. Here, we present a hybrid scheme combining the microwave SQUID multiplexer with code division multiplexing: the impedance-modulated code-division multiplexer (Z-CDM), which may enable an order of magnitude increase in multiplexing factor particularly for low-bandwidth signal applications.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics
Authors:
A. Nadolski,
J. D. Vieira,
J. A. Sobrin,
A. M. Kofman,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. R. Cheshire IV,
G. E. Chesmore,
J. F. Cliche,
A. Cukierman,
T. de Haan,
M. Dierickx,
J. Ding,
D. Dutcher,
W. Everett
, et al. (64 additional authors not shown)
Abstract:
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of com…
▽ More
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially-available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97 +/- 2)% transmittance and the lenslet coating sample achieves (94 +/- 3)% transmittance.
△ Less
Submitted 2 March, 2020; v1 submitted 6 December, 2019;
originally announced December 2019.
-
Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G
Authors:
A. J. Anderson,
P. A. R. Ade,
Z. Ahmed,
J. S. Avva,
P. S. Barry,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of the…
▽ More
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-lab characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.
△ Less
Submitted 27 July, 2019;
originally announced July 2019.
-
On-sky performance of the SPT-3G frequency-domain multiplexed readout
Authors:
A. N. Bender,
A. J. Anderson,
J. S. Avva,
P. A. R. Ade,
Z. Ahmed,
P. S. Barry,
R. Basu Thakur,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current…
▽ More
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of $\sim$16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G's measurements of sky power on large angular scales. Measurements also show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Exclusion Limits on Hidden-Photon Dark Matter near 2 neV from a Fixed-Frequency Superconducting Lumped-Element Resonator
Authors:
A. Phipps,
S. E. Kuenstner,
S. Chaudhuri,
C. S. Dawson,
B. A. Young,
C. T. FitzGerald,
H. Froland,
K. Wells,
D. Li,
H. M. Cho,
S. Rajendran,
P. W. Graham,
K. D. Irwin
Abstract:
We present the design and performance of a simple fixed-frequency superconducting lumped-element resonator developed for axion and hidden photon dark matter detection. A rectangular NbTi inductor was coupled to a Nb-coated sapphire capacitor and immersed in liquid helium within a superconducting shield. The resonator was transformer-coupled to a DC SQUID for readout. We measured a quality factor o…
▽ More
We present the design and performance of a simple fixed-frequency superconducting lumped-element resonator developed for axion and hidden photon dark matter detection. A rectangular NbTi inductor was coupled to a Nb-coated sapphire capacitor and immersed in liquid helium within a superconducting shield. The resonator was transformer-coupled to a DC SQUID for readout. We measured a quality factor of $\sim$40,000 at the resonant frequency of 492.027 kHz and set a simple exclusion limit on $\sim$2 neV hidden photons with kinetic mixing angle $\varepsilon\gtrsim1.5\times10^{-9}$ based on 5.14 hours of integrated noise. This test device informs the development of the Dark Matter Radio, a tunable superconducting lumped-element resonator which will search for axions and hidden photons over the 100 Hz to 300 MHz frequency range.
△ Less
Submitted 20 June, 2019;
originally announced June 2019.
-
Design and characterization of the SPT-3G receiver
Authors:
J. A. Sobrin,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Gallichio,
A. Gilbert,
J. C. Groh,
S. T. Guns,
N. W. Halverson
, et al. (46 additional authors not shown)
Abstract:
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle…
▽ More
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We highlight several key features and design principles of the new receiver, and summarize its performance to date.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
Broadband anti-reflective coatings for cosmic microwave background experiments
Authors:
A. Nadolski,
A. M. Kofman,
J. D. Vieira,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Fu,
J. Gallicchio,
A. Gilbert
, et al. (49 additional authors not shown)
Abstract:
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth comp…
▽ More
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to $\sim$700 mm diameter) and lenslets ($\sim$5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetrafluoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
A Spread-Spectrum SQUID Multiplexer
Authors:
K. D. Irwin,
S. Chaudhuri,
H. -M. Cho,
C. Dawson,
S. Kuenstner,
D. Li,
C. J. Titus,
B. A. Young
Abstract:
The Transition-Edge Sensors (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed, time-division multiplexing schemes operating at MHz frequencies are being replaced by microwave SQUID multiplexers using frequency-division multiplexing at GHz fr…
▽ More
The Transition-Edge Sensors (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed, time-division multiplexing schemes operating at MHz frequencies are being replaced by microwave SQUID multiplexers using frequency-division multiplexing at GHz frequencies. However, the multiplexing factor achievable with microwave SQUIDs is limited by the high slew rate on the leading edge of x-ray pulses. In this paper, we propose a new multiplexing scheme for high-slew-rate TES x-ray calorimeters: the spread-spectrum SQUID multiplexer, which has the potential to enable higher multiplexing factors, especially in applications with lower photon arrival rates.
△ Less
Submitted 7 June, 2018;
originally announced June 2018.
-
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Authors:
A. S. Bergman,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. A. Austermann,
J. A. Beall,
D. T. Becker,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (54 additional authors not shown)
Abstract:
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod…
▽ More
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
△ Less
Submitted 22 November, 2017; v1 submitted 11 November, 2017;
originally announced November 2017.
-
L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array
Authors:
Charles J. Titus,
Michael L. Baker,
Sang Jun Lee,
Hsiao-mei Cho,
William B. Doriese,
Joseph W. Fowler,
Kelly Gaffney,
Johnathon D. Gard,
Gene C. Hilton,
Chris Kenney,
Jason Knight,
Dale Li,
Ron Marks,
Michael P. Minitti,
Kelsey M. Morgan,
Galen C. O'Neil,
Carl D. Reintsema,
Daniel R. Schmidt,
Dimosthenis Sokaras,
Daniel S. Swetz,
Joel N. Ullom,
Tsu-Chien Weng,
Christopher Williams,
Betty A. Young,
Kent D. Irwin
, et al. (2 additional authors not shown)
Abstract:
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in ag…
▽ More
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by conventional grating-based spectrometers. These results show that soft X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.
△ Less
Submitted 18 August, 2017; v1 submitted 29 June, 2017;
originally announced June 2017.
-
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
O. Doré,
J. P. Filippini,
A. A. Fraisse,
A. Gambrel,
N. N. Gandilo,
M. Hasselfield,
M. Halpern,
G. C. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin,
W. C. Jones,
Z. Kermish,
C. J. MacTavish,
P. V. Mason
, et al. (18 additional authors not shown)
Abstract:
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid he…
▽ More
We describe the SPIDER flight cryostat, which is designed to cool six millimeter-wavelength telescopes during an Antarctic long-duration balloon flight. The cryostat, one of the largest to have flown on a stratospheric payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6 K. Stainless steel capillaries facilitate a high flow impedance connection between the main liquid helium tank and a smaller superfluid tank, allowing the latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank. Each telescope houses a closed cycle helium-3 adsorption refrigerator that further cools the focal planes down to 300 mK. Liquid helium vapor from the main tank is routed through heat exchangers that cool radiation shields, providing negative thermal feedback. The system performed successfully during a 17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold time of 16.8 days, with 15.9 days occurring during flight.
△ Less
Submitted 11 September, 2015; v1 submitted 23 June, 2015;
originally announced June 2015.
-
Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
Authors:
J. D. Soler,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
C. Chiang,
C. C. Contaldi,
B. P. Crill,
O. P. Doré,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
A. E. Gambrel,
N. N. Gandilo,
S. Golwala,
J. E. Gudmundsson,
M. Halpern,
M. Hasselfield,
G. C. Hilton,
W. A. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (22 additional authors not shown)
Abstract:
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne in…
▽ More
We introduce the light-weight carbon fiber and aluminum gondola designed for the SPIDER balloon-borne telescope. SPIDER is designed to measure the polarization of the Cosmic Microwave Background radiation with unprecedented sensitivity and control of systematics in search of the imprint of inflation: a period of exponential expansion in the early Universe. The requirements of this balloon-borne instrument put tight constrains on the mass budget of the payload. The SPIDER gondola is designed to house the experiment and guarantee its operational and structural integrity during its balloon-borne flight, while using less than 10% of the total mass of the payload. We present a construction method for the gondola based on carbon fiber reinforced polymer tubes with aluminum inserts and aluminum multi-tube joints. We describe the validation of the model through Finite Element Analysis and mechanical tests.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
High-resolution kaonic-atom x-ray spectroscopy with transition-edge-sensor microcalorimeters
Authors:
S. Okada,
D. A. Bennett,
W. B. Doriese,
J. W. Fowler,
K. D. Irwin,
S. Ishimoto,
M. Sato,
D. R. Schmidt,
D. S. Swetz,
H. Tatsuno,
J. N. Ullom,
S. Yamada
Abstract:
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction a…
▽ More
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resolutions of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction and provide new accurate charged-kaon mass value.
△ Less
Submitted 18 February, 2014; v1 submitted 30 January, 2014;
originally announced January 2014.
-
A Study of Al-Mn Transition Edge Sensor Engineering for Stability
Authors:
E. M. George,
J. E. Austermann,
J. A. Beall,
D. Becker,
B. A. Benson,
L. E. Bleem,
J. E. Carlstrom,
C. L. Chang,
H- M. Cho,
A. T. Crites,
M. A. Dobbs,
W. Everett,
N. W. Halverson,
J. W. Henning,
G. C. Hilton,
W. L. Holzapfel,
J. Hubmayr,
K. D. Irwin,
D. Li,
M. Lueker,
J. J. McMahon,
J. Mehl,
J. Montgomery,
T. Natoli,
J. P. Nibarger
, et al. (10 additional authors not shown)
Abstract:
The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the 39 designs tested. The data is accurately fit by a two-body bolometer model, which allows us to extract the basic TES parameters that affect device stability. We…
▽ More
The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the 39 designs tested. The data is accurately fit by a two-body bolometer model, which allows us to extract the basic TES parameters that affect device stability. We conclude that parameters affecting device stability can be engineered for optimal device operation, and present the model parameters extracted for the different TES designs.
△ Less
Submitted 10 November, 2013;
originally announced November 2013.
-
High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
Authors:
Omid Noroozian,
John A. B. Mates,
Douglas A. Bennett,
Justus A. Brevik,
Joseph W. Fowler,
Jiansong Gao,
Gene C. Hilton,
Robert D. Horansky,
Kent D. Irwin,
Zhao Kang,
Daniel R. Schmidt,
Leila R. Vale,
Joel N. Ullom
Abstract:
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators co…
▽ More
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.
△ Less
Submitted 27 October, 2013;
originally announced October 2013.
-
Sensor Compendium
Authors:
M. Artuso,
M. Battaglia,
G. Bolla,
D. Bortoletto,
B. Cabrera,
J. E. Carlstrom,
C. L. Chang,
W. Cooper,
C. Da Via,
M. Demarteau,
J. Fast,
H. Frisch,
M. Garcia-Sciveres,
S. Golwala,
C. Haber,
J. Hall,
E. Hoppe,
K. D. Irwin,
H. Kagan,
C. Kenney,
A. T. Lee,
D. Lynn,
J. Orrell,
M. Pyle,
R. Rusack
, et al. (7 additional authors not shown)
Abstract:
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, e…
▽ More
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges
△ Less
Submitted 25 October, 2013; v1 submitted 18 October, 2013;
originally announced October 2013.
-
SCUBA-2: The 10000 pixel bolometer camera on the James Clerk Maxwell Telescope
Authors:
W. S. Holland,
D. Bintley,
E. L. Chapin,
A. Chrysostomou,
G. R. Davis,
J. T. Dempsey,
W. D. Duncan,
M. Fich,
P. Friberg,
M. Halpern,
K. D. Irwin,
T. Jenness,
B. D. Kelly,
M. J. MacIntosh,
E. I. Robson,
D. Scott,
P. A. R. Ade,
E. Atad-Ettedgui,
D. S. Berry,
S. C. Craig,
X. Gao,
A. G. Gibb,
G. C. Hilton,
M. I. Hollister,
J. B. Kycia
, et al. (24 additional authors not shown)
Abstract:
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key questions relating to the origins of galaxies, stars and planets. With two imaging arrays working simultaneously in the atmospheric windows at 450 and 850 micro…
▽ More
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The camera has the capability to carry out wide-field surveys to unprecedented depths, addressing key questions relating to the origins of galaxies, stars and planets. With two imaging arrays working simultaneously in the atmospheric windows at 450 and 850 microns, the vast increase in pixel count means that SCUBA-2 maps the sky 100-150 times faster than the previous SCUBA instrument. In this paper we present an overview of the instrument, discuss the physical characteristics of the superconducting detector arrays, outline the observing modes and data acquisition, and present the early performance figures on the telescope. We also showcase the capabilities of the instrument via some early examples of the science SCUBA-2 has already undertaken. In February 2012, SCUBA-2 began a series of unique legacy surveys for the JCMT community. These surveys will take 2.5 years and the results are already providing complementary data to the shorter wavelength, shallower, larger-area surveys from Herschel. The SCUBA-2 surveys will also provide a wealth of information for further study with new facilities such as ALMA, and future telescopes such as CCAT and SPICA.
△ Less
Submitted 16 January, 2013;
originally announced January 2013.
-
Current distribution and transition width in superconducting transition-edge sensors
Authors:
D. S. Swetz,
D. A. Bennett,
K. D. Irwin,
D. R. Schmidt,
J. N. Ullom
Abstract:
Present models of the superconducting-to-normal transition in transition-edge sensors (TESs) do not describe the current distribution within a biased TES. This distribution is complicated by normal-metal features that are integral to TES design. We present a model with one free parameter that describes the evolution of the current distribution with bias. To probe the current distribution experimen…
▽ More
Present models of the superconducting-to-normal transition in transition-edge sensors (TESs) do not describe the current distribution within a biased TES. This distribution is complicated by normal-metal features that are integral to TES design. We present a model with one free parameter that describes the evolution of the current distribution with bias. To probe the current distribution experimentally, we fabricated TES devices with different current return geometries. Devices where the current return geometry mirrors current flow within the device have sharper transitions, thus allowing for a direct test of the current-flow model. Measurements from these devices show that current meanders through a TES low in the resistive transition but flows across the normal-metal features by 40% of the normal-state resistance. Comparison of transition sharpness between device designs reveals that self-induced magnetic fields play an important role in determining the width of the superconducting transition. [http://dx.doi.org/10.1063/1.4771984]
△ Less
Submitted 14 December, 2012;
originally announced December 2012.
-
A titanium-nitride near-infrared kinetic inductance photon-counting detector and its anomalous electrodynamics
Authors:
J. Gao,
M. R. Visser,
M. O. Sandberg,
F. C. S. da Silva,
S. W. Nam,
D. P. Pappas,
K. D. Irwin,
D. S. Wisbey,
E. Langman,
S. R. Meeker,
B. A. Mazin,
H. G. Leduc,
J. Zmuidzinas
Abstract:
We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation…
▽ More
We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation response shows a shorter decay time than the frequency response at low temperatures. We suggest that the observed anomalous electrodynamics may be related to quasiparticle traps or subgap states in the disordered TiN films. Finally, the electron density-of-states is derived from the pulse response.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.
-
Code-division multiplexing for x-ray microcalorimeters
Authors:
G. M. Stiehl,
W. B. Doriese,
J. W. Fowler,
G. C. Hilton,
K. D. Irwin,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale.
Abstract:
We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM system is described and compared with similar time-division multiplexed (TDM) readout. We show t…
▽ More
We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM system is described and compared with similar time-division multiplexed (TDM) readout. We show that the sqrt(Npixels) multiplexing disadvantage associated with TDM is not present in CDM. This demonstration establishes CDM as both a simple route to higher performance in existing TDM microcalorimetric experiments and a long-term approach to reaching higher multiplexing factors.
△ Less
Submitted 30 January, 2012;
originally announced January 2012.
-
Optimization and analysis of code-division multiplexed TES microcalorimeters
Authors:
J. W. Fowler,
W. B. Doriese,
G. C. Hilton,
K. D. Irwin,
D. R. Schmidt,
G. M. Stiehl,
D. S. Swetz,
J. N. Ullom,
L. R. Vale.
Abstract:
We are develo** code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that employs a flux-summing architecture, emphasizing data-analysis issues. We describe an empirical method to determine the demodulation matrix that minimizes cross…
▽ More
We are develo** code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that employs a flux-summing architecture, emphasizing data-analysis issues. We describe an empirical method to determine the demodulation matrix that minimizes cross-talk. This CDM system achieves energy resolutions of between 2.3 eV and 3.0 eV FWHM at 5.9 keV.
△ Less
Submitted 11 October, 2011;
originally announced October 2011.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.
-
Design and Testing of Superconducting Microwave Passive Components for Quantum Information Processing
Authors:
H. S. Ku,
F. Mallet,
L. R. Vale,
K. D. Irwin,
S. E. Russek,
G. C. Hilton,
K. W. Lehnert
Abstract:
We report on the design, fabrication and testing of two superconducting passive microwave components, a quadrature hybrid and a 20 dB directional coupler. These components are designed to be integrated with superconducting qubits or Josephson parametric amplifiers and used in quantum information processing applications. For the coupler, we measure return loss and isolation > 20 dB, and insertion l…
▽ More
We report on the design, fabrication and testing of two superconducting passive microwave components, a quadrature hybrid and a 20 dB directional coupler. These components are designed to be integrated with superconducting qubits or Josephson parametric amplifiers and used in quantum information processing applications. For the coupler, we measure return loss and isolation > 20 dB, and insertion loss < 0.3 dB in a 2 GHz band around 6 GHz. For the hybrid performance, we measure isolation > 20 dB and insertion loss < 0.3 dB in a 10% band around 6.5 GHz. These values are within the design specifications of our application; however, we find a 7% difference between the designed and measured center frequency for the hybrid.
△ Less
Submitted 15 October, 2010;
originally announced October 2010.