-
Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D
Authors:
K. Dehmelt,
M. Della Pietra,
H. Muller,
S. E. Tzamarias,
A. White,
S. White,
Z. Zhang,
M. Alviggi,
I. Angelis,
S. Aune,
J. Bortfeldt,
M. Bregant,
F. Brunbauer,
M. T. Camerlingo,
V. Canale,
V. D'Amico,
D. Desforge,
C. Di Donato,
R. Di Nardo,
G. Fanourakis,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo
, et al. (45 additional authors not shown)
Abstract:
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51…
▽ More
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.
△ Less
Submitted 19 March, 2022; v1 submitted 12 March, 2022;
originally announced March 2022.
-
MPGDs for tracking and Muon detection at future high energy physics colliders
Authors:
K. Black,
A. Colaleo,
C. Aimè,
M. Alviggi,
C. Aruta,
M. Bianco,
I. Balossino,
G. Bencivenni,
M. Bertani,
A. Braghieri,
V. Cafaro,
S. Calzaferri,
M. T. Camerlingo,
V. Canale,
G. Cibinetto,
M. Corbetta,
V. D'Amico,
E. De Lucia,
M. Della Pietra,
C. Di Donato,
R. Di Nardo,
D. Domenici,
F. Errico,
P. Everaerts,
F. Fallavollita
, et al. (39 additional authors not shown)
Abstract:
In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high backgro…
▽ More
In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high background environments are required in order to accomplish the physics program. MPGDs offer a diversity of technologies that allow them to meet the required performance challenges at future facilities thanks to the specific advantages that each technology provides. MPGDs allow stable operation, with environmentally friendly gas mixtures, at very high background particle flux with high detection efficiency and excellent spatial resolution. These features make MPGD one of the primary choices as precise muon tracking and trigger system in general-purpose detectors at future HEP colliders. In addition, the low material budget and the flexibility of the base material make MPGDs suitable for the development of very light, full cylindrical fine tracking inner trackers at lepton colliders. On-going R&Ds aim at pushing the detector performance at the limits of each technology. We are working in continuing to consolidate the construction and stable operation of large-size detectors, able to cope with large particle fluxes. In this white paper, we describe some of the most prominent MPGD technologies, their performance measurements, the challenges faced in the most recent applications, and the areas of improvement towards efficient tracking and Muon detection at future high energy physics colliders.
△ Less
Submitted 12 March, 2022;
originally announced March 2022.
-
Pulsed Schlieren Imaging of Ultrasonic Haptics and Levitation using Phased Arrays
Authors:
Michele Iodice,
William Frier,
James Wilcox,
Ben Long,
Orestis Georgiou
Abstract:
Ultrasonic acoustic fields have recently been used to generate haptic effects on the human skin as well as to levitate small sub-wavelength size particles. Schlieren imaging and background-oriented schlieren techniques can be used for acoustic wave pattern and beam shape visualization. These techniques exploit variations in the refractive index of a propagation medium by applying refractive optics…
▽ More
Ultrasonic acoustic fields have recently been used to generate haptic effects on the human skin as well as to levitate small sub-wavelength size particles. Schlieren imaging and background-oriented schlieren techniques can be used for acoustic wave pattern and beam shape visualization. These techniques exploit variations in the refractive index of a propagation medium by applying refractive optics or cross-correlation algorithms of photographs of illuminated background patterns. Here both background-oriented and traditional schlieren systems are used to visualize the regions of the acoustic power involved in creating dynamic haptic sensations and dynamic levitation traps. We demonstrate for the first time the application of back-ground-oriented schlieren for imaging ultrasonic fields in air. We detail our imaging apparatus and present improved algorithms used to visualize these phenomena that we have produced using multiple phased arrays. Moreover, to improve imaging, we leverage an electronically controlled, high-output LED which is pulsed in synchrony with the ultrasonic carrier frequency.
△ Less
Submitted 29 September, 2018;
originally announced October 2018.
-
Construction techniques and performances of a full-size prototype Micromegas chamber for the ATLAS muon spectrometer upgrade
Authors:
T. Alexopoulos,
M. Alviggi,
M. Antonelli,
F. Anulli,
C. Arcangeletti,
P. Bagnaia,
A. Baroncelli,
M. Beretta,
C. Bini,
J. Bortfeldt,
D. Calabrò,
V. Canale,
G. Capradossi,
G. Carducci,
A. Caserio,
C. Cassese,
S. Cerioni,
G. Ciapetti,
V. D' Amico,
B. De Fazio,
M. Del Gaudio,
C. Di Donato,
R. Di Nardo,
D. D' Uffizi,
E. Farina
, et al. (54 additional authors not shown)
Abstract:
A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in constructing the single modules of the chamber in various INFN laboratories and the final assembly at the Laboratori Nazionali di Frascati (LNF). Results of the chamber ex…
▽ More
A full-size prototype of a Micromegas precision tracking chamber for the upgrade of the ATLAS detector at the LHC Collider has been built between October 2015 and April 2016. This paper describes in detail the procedures used in constructing the single modules of the chamber in various INFN laboratories and the final assembly at the Laboratori Nazionali di Frascati (LNF). Results of the chamber exposure to the CERN SPS/H8 beam line in June 2016 are also presented. The performances achieved in the construction and the results of the test beam are compared with the requirements, which are imposed by the severe environment during the data-taking of the LHC foreseen for the next years.
△ Less
Submitted 11 September, 2018; v1 submitted 29 August, 2018;
originally announced August 2018.
-
Free-space graphene/silicon photodetectors operating at 2 micron
Authors:
M. Casalino,
R. Russo,
C. Russo,
A. Ciajolo,
E. Di Gennaro,
M. Iodice,
G. Coppola
Abstract:
This paper presents the design, the fabrication and the characterization of Schottky graphene/silicon photodetectors, operating at both 2 micron and room temperature. The graphene/silicon junction has been carefully: characterized device shows a non ideal behaviour with the increasing temperature and the interfacial trap density has been measured as 1.1x10^14 eV^-1cm^-2. Photodetectors are charact…
▽ More
This paper presents the design, the fabrication and the characterization of Schottky graphene/silicon photodetectors, operating at both 2 micron and room temperature. The graphene/silicon junction has been carefully: characterized device shows a non ideal behaviour with the increasing temperature and the interfacial trap density has been measured as 1.1x10^14 eV^-1cm^-2. Photodetectors are characterized by an internal (external) responsivity of 10.3 mA/W (0.16 mA/W) in an excellent agreement with the theory. Our devices pave the way for develo** hybrid graphene-Si free-space illuminated PDs operating at 2 micron, for free-space optical communications, optical coherence tomography and light-radars.
△ Less
Submitted 15 November, 2017;
originally announced December 2017.
-
Vertically-Illuminated, Resonant-Cavity-Enhanced, Graphene-Silicon Schottky Photodetectors
Authors:
M. Casalino,
U. Sassi,
I. Goykhman,
A. Eiden,
E. Lidorikis,
S. Milana,
D. De Fazio,
F. Tomarchio,
M. Iodice,
G. Coppola,
A. C. Ferrari
Abstract:
We report vertically-illuminated, resonant cavity enhanced, graphene-Si Schottky photodetectors (PDs) operating at 1550nm. These exploit internal photoemission at the graphene-Si interface. To obtain spectral selectivity and enhance responsivity, the PDs are integrated with an optical cavity, resulting in multiple reflections at resonance, and enhanced absorption in graphene. Our devices have wave…
▽ More
We report vertically-illuminated, resonant cavity enhanced, graphene-Si Schottky photodetectors (PDs) operating at 1550nm. These exploit internal photoemission at the graphene-Si interface. To obtain spectral selectivity and enhance responsivity, the PDs are integrated with an optical cavity, resulting in multiple reflections at resonance, and enhanced absorption in graphene. Our devices have wavelength-dependent photoresponse with external (internal) responsivity~20mA/W (0.25A/W). The spectral-selectivity may be further tuned by varying the cavity resonant wavelength. Our devices pave the way for develo** high responsivity hybrid graphene-Si free-space illuminated PDs for free-space optical communications, coherence optical tomography and light-radars
△ Less
Submitted 8 July, 2017;
originally announced August 2017.
-
Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer
Authors:
S. Marrone,
B. B. Wojtsekhowski,
A. Acha,
E. Cisbani,
M. Coman,
F. Cusanno,
C. W. de Jager,
R. De Leo,
H. Gao,
F. Garibaldi,
D. W. Higinbotham,
M. Iodice,
J. J. LeRose,
D. Macchia,
P. Markowitz,
E. Nappia,
F. Palmisano,
G. M. Urciuoli,
I. van der Werf,
H. Xiang,
L. Y. Zhu
Abstract:
We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found…
▽ More
We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found to be noticeably reduced in both detectors as a result of contamination, yellowing, of the aerogel material. Along with the details of the set-up, we illustrate the characteristics of the detectors during different time periods and the probable causes of the contamination. In particular we show that the replacement of the contaminated aerogel and parts of the reflecting material has almost restored the initial performance of the detectors.
△ Less
Submitted 25 October, 2008;
originally announced October 2008.