Skip to main content

Showing 1–10 of 10 results for author: Ingleby, S J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.19178  [pdf, other

    physics.atom-ph

    Longitudinal spin-relaxation optimization for miniaturized optically pumped magnetometers

    Authors: A. P. McWilliam, S. Dyer, D. Hunter, M. Mrozowski, S. J. Ingleby, O. Sharp, D. P. Burt, P. F. Griffin, J. P. McGilligan, E. Riis

    Abstract: The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal re… ▽ More

    Submitted 3 July, 2024; v1 submitted 27 June, 2024; originally announced June 2024.

    Comments: 7 pages (inc references), 3 figures

  2. arXiv:2307.11600  [pdf, other

    physics.atom-ph

    Optical pum** enhancement of a free-induction-decay magnetometer

    Authors: Dominic Hunter, Marcin S. Mrozowski, Allan McWilliam, Stuart J. Ingleby, Terry E. Dyer, Paul F. Griffin, Erling Riis

    Abstract: Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pum** with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed ma… ▽ More

    Submitted 29 September, 2023; v1 submitted 21 July, 2023; originally announced July 2023.

    Comments: 10 pages, 7 figures

    Journal ref: Journal of the Optical Society of America B, vol 40, issue 10, pp. 2489-2683 (2023)

  3. arXiv:2303.10915  [pdf, other

    physics.app-ph

    Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell

    Authors: D. Hunter, C. Perrella, A. McWilliam, J. P. McGilligan, M. Mrozowski, S. J. Ingleby, P. F. Griffin, D. Burt, A. N. Luiten, E. Riis

    Abstract: Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusi… ▽ More

    Submitted 29 September, 2023; v1 submitted 20 March, 2023; originally announced March 2023.

    Comments: 14 pages, 6 figures

    Journal ref: Optics Express, vol. 31, issue 20, pp. 33582-33595 (2023)

  4. arXiv:2207.10348  [pdf, other

    physics.atom-ph

    Ultra-low noise, bi-polar, programmable current sources

    Authors: M. S. Mrozowski, I. C. Chalmers, S. J. Ingleby, P. F. Griffin, E. Riis

    Abstract: We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of $\pm$~10~mA and $\pm$~250~mA… ▽ More

    Submitted 22 July, 2022; v1 submitted 21 July, 2022; originally announced July 2022.

    Comments: 9 pages, 9 figures

  5. arXiv:2003.03267  [pdf, other

    physics.atom-ph physics.app-ph physics.ins-det

    Resonant Very Low- and Ultra Low Frequency Digital Signal Reception Using a Portable Atomic Magnetometer

    Authors: Stuart J. Ingleby, Iain C. Chalmers, Terry E. Dyer, Paul F. Griffin, Erling Riis

    Abstract: Radio communication through attenuating media necessitates the use of very-low frequency (VLF) and ultra-low frequency (ULF) carrier bands, which are frequently used in underwater and under-ground communication applications. Quantum sensing techniques can be used to circumvent hard constraints on the size, weight and noise floor of classical signal transducers. In this low-frequency range, an opti… ▽ More

    Submitted 6 March, 2020; originally announced March 2020.

    Comments: 8 pages, 9 figures

  6. arXiv:1802.09273  [pdf, other

    physics.atom-ph physics.app-ph physics.ins-det

    Vector Magnetometry Exploiting Phase-Geometry Effects in a Double-Resonance Alignment Magnetometer

    Authors: Stuart J. Ingleby, Carolyn O'Dwyer, Paul F. Griffin, Aidan S. Arnold, Erling Riis

    Abstract: Double-resonance optically pumped magnetometers are an attractive instrument for unshielded magnetic field measurements due to their wide dynamic range and high sensitivity. Use of linearly polarised pump light creates alignment in the atomic sample, which evolves in the local static magnetic field, and is driven by a resonant applied field perturbation, modulating the polarisation of transmitted… ▽ More

    Submitted 26 February, 2018; originally announced February 2018.

    Comments: 8 pages, 7 figures

    Journal ref: Phys. Rev. Applied 10, 034035 (2018)

  7. arXiv:1710.07024  [pdf

    physics.atom-ph physics.ins-det

    Optically Pumped Magnetometry in Arbitrarily Oriented Magnetic Fields

    Authors: Stuart J. Ingleby, Iain C. Chalmers, Carolyn O'Dwyer, Paul F. Griffin, Aidan S. Arnold, Erling Riis

    Abstract: Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded magnetometry, due to high sensor dynamic range. However, sensor response is highly anisotropic with variation in the orientation of the magnetic field. We present dat… ▽ More

    Submitted 19 October, 2017; originally announced October 2017.

    Comments: IEEE Sensors 2017 paper preprint

  8. Orientational Effects on the Amplitude and Phase of Polarimeter Signals in Double Resonance Atomic Magnetometry

    Authors: Stuart J. Ingleby, Carolyn O'Dwyer, Paul F. Griffin, Aidan S. Arnold, Erling Riis

    Abstract: Double resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant frequency yields a scalar measurement of static field ($B_0$) magnitude. We present calculations and experimental data showing that the on-resonance polarimeter signal… ▽ More

    Submitted 14 July, 2017; originally announced July 2017.

  9. arXiv:1704.00980  [pdf

    physics.ins-det physics.atom-ph

    High-precision control of static magnetic field magnitude, orientation, and gradient using optically pumped vapour cell magnetometry

    Authors: S. J. Ingleby, P. F. Griffin, A. S. Arnold, M. Chouliara, E. Riis

    Abstract: An integrated system of hardware and software allowing precise definition of arbitrarily oriented magnetic fields up to |B| = 1 μT within a five-layer mumetal shield is described. The system is calibrated with reference to magnetic resonance observed between Zeeman states of the 6S$_{1/2}$ F = 4 $^{133}$Cs ground state. Magnetic field definition over the full 4π solid angle is demonstrated, with o… ▽ More

    Submitted 4 April, 2017; originally announced April 2017.

    Comments: 14 pages, 10 figures

  10. arXiv:1702.04150  [pdf, other

    physics.atom-ph quant-ph

    Grating chips for quantum technologies

    Authors: James P. McGilligan, Paul F. Griffin, Rachel Elvin, Stuart J. Ingleby, Erling Riis, Aidan S. Arnold

    Abstract: We have laser cooled 3$\times10^6$ $^{87}$Rb atoms to 3$μ$K in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam,… ▽ More

    Submitted 14 February, 2017; originally announced February 2017.

    Comments: 8 pages, 6 figures

    Journal ref: Scientific Reports 7, Article number: 384 (2017)