Longitudinal spin-relaxation optimization for miniaturized optically pumped magnetometers
Authors:
A. P. McWilliam,
S. Dyer,
D. Hunter,
M. Mrozowski,
S. J. Ingleby,
O. Sharp,
D. P. Burt,
P. F. Griffin,
J. P. McGilligan,
E. Riis
Abstract:
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal re…
▽ More
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, $γ_{10}$, and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted through employing an optically pumped magnetometer operating in a free-induction-decay configuration. $γ_{10}$ is extracted across a range of nitrogen pressures between $\sim$~60~-~700~Torr, measuring a minimum of 140~Hz at 115~Torr. Additionally, we achieve sensitivities as low as 130 ~fT/$\sqrt{\text{Hz}}$ at a bias field amplitude of $\sim 50~μ$T. With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance.
△ Less
Submitted 3 July, 2024; v1 submitted 27 June, 2024;
originally announced June 2024.
-
Optical pum** enhancement of a free-induction-decay magnetometer
Authors:
Dominic Hunter,
Marcin S. Mrozowski,
Allan McWilliam,
Stuart J. Ingleby,
Terry E. Dyer,
Paul F. Griffin,
Erling Riis
Abstract:
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pum** with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed ma…
▽ More
Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pum** with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed magnetic field is generated along the optical pum** axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium (Cs) vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pum** modalities across a wide magnetic field range. A noise floor sensitivity of $238\,\mathrm{fT/\surd{Hz}}$ was achieved in a field of approximately $\mathrm{50\,μ{T}}$, in close agreement with the Cramér-Rao lower bound (CRLB) predicted noise density of $258\,\mathrm{fT/\surd{Hz}}$.
△ Less
Submitted 29 September, 2023; v1 submitted 21 July, 2023;
originally announced July 2023.
-
Free-induction-decay magnetic field imaging with a microfabricated Cs vapor cell
Authors:
D. Hunter,
C. Perrella,
A. McWilliam,
J. P. McGilligan,
M. Mrozowski,
S. J. Ingleby,
P. F. Griffin,
D. Burt,
A. N. Luiten,
E. Riis
Abstract:
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusi…
▽ More
Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated cesium (Cs) vapor cell technology to visualize the magnetic field distributions resulting from various magnetic sources placed close to the cell. The slow diffusion of Cs atoms in the presence of a nitrogen (N$_{2}$) buffer gas enables spatially independent measurements to be made within the same vapor cell by translating a $175\,μ$m probe beam over the sensing area. For example, the OPM was used to record temporal and spatial information to reconstruct magnetic field distributions in one and two dimensions. The optimal magnetometer sensitivity was estimated to be 0.43$\,\mathrm{pT/\sqrt{Hz}}$ within a Nyquist limited bandwidth of $500\,$Hz. Furthermore, the sensor's dynamic range exceeds the Earth's field of approximately $50\,μ$T, which provides a framework for magnetic field imaging in unshielded environments.
△ Less
Submitted 29 September, 2023; v1 submitted 20 March, 2023;
originally announced March 2023.
-
Ultra-low noise, bi-polar, programmable current sources
Authors:
M. S. Mrozowski,
I. C. Chalmers,
S. J. Ingleby,
P. F. Griffin,
E. Riis
Abstract:
We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of $\pm$~10~mA and $\pm$~250~mA…
▽ More
We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of $\pm$~10~mA and $\pm$~250~mA respectively on three independent channels with 16-bit resolution. Both devices feature narrow 1/f noise bandwidth of 1~Hz, enabling magnetic field manipulation for high-performance OPMs. They exhibit low noise of 146.3~pA/$\sqrt{\mathrm{Hz}}$ and 4114~pA/$\sqrt{\mathrm{Hz}}$ which translates to 14.57~ppb/$\sqrt{\mathrm{Hz}}$ and 16.46~ppb/$\sqrt{\mathrm{Hz}}$ noise relative to full scale.
△ Less
Submitted 22 July, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Resonant Very Low- and Ultra Low Frequency Digital Signal Reception Using a Portable Atomic Magnetometer
Authors:
Stuart J. Ingleby,
Iain C. Chalmers,
Terry E. Dyer,
Paul F. Griffin,
Erling Riis
Abstract:
Radio communication through attenuating media necessitates the use of very-low frequency (VLF) and ultra-low frequency (ULF) carrier bands, which are frequently used in underwater and under-ground communication applications. Quantum sensing techniques can be used to circumvent hard constraints on the size, weight and noise floor of classical signal transducers. In this low-frequency range, an opti…
▽ More
Radio communication through attenuating media necessitates the use of very-low frequency (VLF) and ultra-low frequency (ULF) carrier bands, which are frequently used in underwater and under-ground communication applications. Quantum sensing techniques can be used to circumvent hard constraints on the size, weight and noise floor of classical signal transducers. In this low-frequency range, an optically pumped atomic sample can be used to detect carrier wave modulation resonant with ground-state Zeeman splitting of alkali atoms. Using a compact, self-calibrating system we demonstrate a resonant atomic transducer for digital data encoded using binary phase- and frequency-keying of resonant carrier waves in the 200 Hz -200 kHz range. We present field trial data showing sensor noise floor, decoded data and received bit error rate, and calculate the projected range of sub-sea communication using this device.
△ Less
Submitted 6 March, 2020;
originally announced March 2020.
-
Vector Magnetometry Exploiting Phase-Geometry Effects in a Double-Resonance Alignment Magnetometer
Authors:
Stuart J. Ingleby,
Carolyn O'Dwyer,
Paul F. Griffin,
Aidan S. Arnold,
Erling Riis
Abstract:
Double-resonance optically pumped magnetometers are an attractive instrument for unshielded magnetic field measurements due to their wide dynamic range and high sensitivity. Use of linearly polarised pump light creates alignment in the atomic sample, which evolves in the local static magnetic field, and is driven by a resonant applied field perturbation, modulating the polarisation of transmitted…
▽ More
Double-resonance optically pumped magnetometers are an attractive instrument for unshielded magnetic field measurements due to their wide dynamic range and high sensitivity. Use of linearly polarised pump light creates alignment in the atomic sample, which evolves in the local static magnetic field, and is driven by a resonant applied field perturbation, modulating the polarisation of transmitted light. We show for the first time that the amplitude and phase of observed first- and second-harmonic components in the transmitted polarisation signal contain sufficient information to measure static magnetic field magnitude and orientation. We describe a laboratory system for experimental measurements of these effects and verify a theoretical derivation of the observed signal. We demonstrate vector field tracking under varying static field orientations and show that the static field magnitude and orientation may be observed simultaneously, with experimentally realised resolution of 1.7 pT and 0.63 mrad in the most sensitive field orientation.
△ Less
Submitted 26 February, 2018;
originally announced February 2018.
-
Optically Pumped Magnetometry in Arbitrarily Oriented Magnetic Fields
Authors:
Stuart J. Ingleby,
Iain C. Chalmers,
Carolyn O'Dwyer,
Paul F. Griffin,
Aidan S. Arnold,
Erling Riis
Abstract:
Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded magnetometry, due to high sensor dynamic range. However, sensor response is highly anisotropic with variation in the orientation of the magnetic field. We present dat…
▽ More
Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded magnetometry, due to high sensor dynamic range. However, sensor response is highly anisotropic with variation in the orientation of the magnetic field. We present data quantifying these effects and discuss implications for the design of practical sensors.
△ Less
Submitted 19 October, 2017;
originally announced October 2017.
-
Orientational Effects on the Amplitude and Phase of Polarimeter Signals in Double Resonance Atomic Magnetometry
Authors:
Stuart J. Ingleby,
Carolyn O'Dwyer,
Paul F. Griffin,
Aidan S. Arnold,
Erling Riis
Abstract:
Double resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant frequency yields a scalar measurement of static field ($B_0$) magnitude. We present calculations and experimental data showing that the on-resonance polarimeter signal…
▽ More
Double resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant frequency yields a scalar measurement of static field ($B_0$) magnitude. We present calculations and experimental data showing that the on-resonance polarimeter signal of light transmitted through an atomic vapour in arbitrarily oriented $B_0$ may be modelled by considering the evolution of alignment terms in atomic polarisation. We observe that the amplitude and phase of the magnetometer signal are highly dependent upon $B_0$ orientation, and present precise measurements of the distribution of these parameters over the full 4π solid angle.
△ Less
Submitted 14 July, 2017;
originally announced July 2017.
-
High-precision control of static magnetic field magnitude, orientation, and gradient using optically pumped vapour cell magnetometry
Authors:
S. J. Ingleby,
P. F. Griffin,
A. S. Arnold,
M. Chouliara,
E. Riis
Abstract:
An integrated system of hardware and software allowing precise definition of arbitrarily oriented magnetic fields up to |B| = 1 μT within a five-layer mumetal shield is described. The system is calibrated with reference to magnetic resonance observed between Zeeman states of the 6S$_{1/2}$ F = 4 $^{133}$Cs ground state. Magnetic field definition over the full 4π solid angle is demonstrated, with o…
▽ More
An integrated system of hardware and software allowing precise definition of arbitrarily oriented magnetic fields up to |B| = 1 μT within a five-layer mumetal shield is described. The system is calibrated with reference to magnetic resonance observed between Zeeman states of the 6S$_{1/2}$ F = 4 $^{133}$Cs ground state. Magnetic field definition over the full 4π solid angle is demonstrated, with one-sigma tolerances in magnitude, orientation and gradient of δ|B| = 0.94 nT, δθ = 5.9 mrad and δ$\nabla$ B = 13.0 pT/mm, respectively. This field control is used to empirically map Mx magnetometer signal amplitude as a function of the static field (B0) orientation.
△ Less
Submitted 4 April, 2017;
originally announced April 2017.
-
Grating chips for quantum technologies
Authors:
James P. McGilligan,
Paul F. Griffin,
Rachel Elvin,
Stuart J. Ingleby,
Erling Riis,
Aidan S. Arnold
Abstract:
We have laser cooled 3$\times10^6$ $^{87}$Rb atoms to 3$μ$K in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam,…
▽ More
We have laser cooled 3$\times10^6$ $^{87}$Rb atoms to 3$μ$K in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam, which will be utilised for future cold atom gradiometry.
△ Less
Submitted 14 February, 2017;
originally announced February 2017.