Quasistatic approximation in neuromodulation
Authors:
Boshuo Wang,
Angel V. Peterchev,
Gabriel Gaugain,
Risto J. Ilmoniemi,
Warren M. Grill,
Marom Bikson,
Denys Nikolayev
Abstract:
We define and explain the quasistatic approximation (QSA) as applied to field modeling for electrical and magnetic stimulation. Neuromodulation analysis pipelines include discrete stages, and QSA is applied specifically when calculating the electric and magnetic fields generated in tissues by a given stimulation dose. QSA simplifies the modeling equations to support tractable analysis, enhanced un…
▽ More
We define and explain the quasistatic approximation (QSA) as applied to field modeling for electrical and magnetic stimulation. Neuromodulation analysis pipelines include discrete stages, and QSA is applied specifically when calculating the electric and magnetic fields generated in tissues by a given stimulation dose. QSA simplifies the modeling equations to support tractable analysis, enhanced understanding, and computational efficiency. The application of QSA in neuro-modulation is based on four underlying assumptions: (A1) no wave propagation or self-induction in tissue, (A2) linear tissue properties, (A3) purely resistive tissue, and (A4) non-dispersive tissue. As a consequence of these assumptions, each tissue is assigned a fixed conductivity, and the simplified equations (e.g., Laplace's equation) are solved for the spatial distribution of the field, which is separated from the field's temporal waveform. Recognizing that electrical tissue properties may be more complex, we explain how QSA can be embedded in parallel or iterative pipelines to model frequency dependence or nonlinearity of conductivity. We survey the history and validity of QSA across specific applications, such as microstimulation, deep brain stimulation, spinal cord stimulation, transcranial electrical stimulation, and transcranial magnetic stimulation. The precise definition and explanation of QSA in neuromodulation are essential for rigor when using QSA models or testing their limits.
△ Less
Submitted 23 April, 2024; v1 submitted 1 February, 2024;
originally announced February 2024.
-
A general method for computing thermal magnetic noise arising from thin conducting objects
Authors:
Joonas Iivanainen,
Antti J. Mäkinen,
Rasmus Zetter,
Koos C. J. Zevenhoven,
Risto J. Ilmoniemi,
Lauri Parkkonen
Abstract:
Thermal motion of charge carriers in a conducting object causes magnetic field noise that interferes with sensitive measurements nearby the conductor. In this paper, we describe a method to compute the spectral properties of the thermal magnetic noise from arbitrarily-shaped thin conducting objects. We model divergence-free currents on a conducting surface using a stream function and calculate the…
▽ More
Thermal motion of charge carriers in a conducting object causes magnetic field noise that interferes with sensitive measurements nearby the conductor. In this paper, we describe a method to compute the spectral properties of the thermal magnetic noise from arbitrarily-shaped thin conducting objects. We model divergence-free currents on a conducting surface using a stream function and calculate the magnetically independent noise-current modes in the quasi-static regime. We obtain the power spectral density of the thermal magnetic noise as well as its spatial correlations and frequency dependence. We describe a numerical implementation of the method; we model the conducting surface using a triangle mesh and discretize the stream function. The numerical magnetic noise computation agrees with analytical formulas. We provide the implementation as a part of the free and open-source software package bfieldtools.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Spatial sampling of MEG and EEG revisited: From spatial-frequency spectra to model-informed sampling
Authors:
Joonas Iivanainen,
Antti J. Mäkinen,
Rasmus Zetter,
Matti Stenroos,
Risto J. Ilmoniemi,
Lauri Parkkonen
Abstract:
In this paper, we analyze spatial sampling of electro- (EEG) magnetoencephalography (MEG), where the electric or magnetic field is typically sampled on a curved surface such as the scalp. Using simulated measurements, we study the spatial-frequency content in EEG as well as in on- and off-scalp MEG. The analysis suggests that on-scalp MEG would generally benefit from three times more samples than…
▽ More
In this paper, we analyze spatial sampling of electro- (EEG) magnetoencephalography (MEG), where the electric or magnetic field is typically sampled on a curved surface such as the scalp. Using simulated measurements, we study the spatial-frequency content in EEG as well as in on- and off-scalp MEG. The analysis suggests that on-scalp MEG would generally benefit from three times more samples than EEG or off-scalp MEG. Based on the theory of Gaussian processes and experimental design, we suggest an approach to obtain sampling locations on surfaces that are optimal with respect to prior assumptions. Additionally, the approach allows to control, e.g., the uniformity of the sampling locations in the grid. By simulating the performance of grids constructed with different priors, we show that for a low number of spatial samples, model-informed non-uniform sampling can be beneficial. For a large number of samples, uniform sampling grids yield nearly the same total information as the model-informed grids.
△ Less
Submitted 3 June, 2020;
originally announced June 2020.
-
Magnetic-field modeling with surface currents: Physical and computational principles of bfieldtools
Authors:
Antti J. Mäkinen,
Rasmus Zetter,
Joonas Iivanainen,
Koos C. J. Zevenhoven,
Lauri Parkkonen,
Risto J. Ilmoniemi
Abstract:
Surface currents provide a general way to model static magnetic fields in source-free volumes. To facilitate the use of surface currents in magneto-quasistatic problems, we have implemented a set of computational tools in a Python package named bfieldtools. In this work, we describe the physical and computational principles of this toolset. To be able to work with surface currents of arbitrary sha…
▽ More
Surface currents provide a general way to model static magnetic fields in source-free volumes. To facilitate the use of surface currents in magneto-quasistatic problems, we have implemented a set of computational tools in a Python package named bfieldtools. In this work, we describe the physical and computational principles of this toolset. To be able to work with surface currents of arbitrary shape, we discretize the currents on triangle meshes using piecewise-linear stream functions. We apply analytical discretizations of integral equations to obtain the magnetic field and potentials associated with the discrete stream function. In addition, we describe the computation of the spherical multipole expansion and a novel surface-harmonic expansion for surface currents, both of which are useful for representing the magnetic field in source-free volumes with a small number of parameters. Last, we share examples related to magnetic shielding and surface-coil design using the presented tools.
△ Less
Submitted 2 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
Magnetic-field modeling with surface currents: Implementation and usage of bfieldtools
Authors:
Rasmus Zetter,
Antti J. Mäkinen,
Joonas Iivanainen,
Koos C. J. Zevenhoven,
Risto J. Ilmoniemi,
Lauri Parkkonen
Abstract:
We present a novel open-source Python software package, bfieldtools, for magneto-quasistatic calculations with current densities on surfaces of arbitrary shape. The core functionality of the software relies on a stream-function representation of surface-current density and its discretization on a triangle mesh. Although this stream-function technique is well-known in certain fields, to date the re…
▽ More
We present a novel open-source Python software package, bfieldtools, for magneto-quasistatic calculations with current densities on surfaces of arbitrary shape. The core functionality of the software relies on a stream-function representation of surface-current density and its discretization on a triangle mesh. Although this stream-function technique is well-known in certain fields, to date the related software implementations have not been published or have been limited to specific applications. With bfieldtools, we aimed to produce a general, easy-to-use and well-documented open-source software. The software package is written purely in Python; instead of explicitly using lower-level languages, we address computational bottlenecks through extensive vectorization and use of the NumPy library. The package enables easy deployment, rapid code development and facilitates application of the software to practical problems. In this paper, we describe the software package and give an extensive demonstration of its use with an emphasis on one of its main applications -- coil design.
△ Less
Submitted 1 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
Evaluating the Performance of Ultra-Low-Field MRI for In-vivo 3D Current Density Imaging of the Human Head
Authors:
Peter Hömmen,
Antti J. Mäkinen,
Alexander Hunold,
René Machts,
Jens Haueisen,
Koos C. J. Zevenhoven,
Risto J. Ilmoniemi,
Rainer Körber
Abstract:
Magnetic fields associated with currents flowing in tissue can be measured non-invasively by means of zero-field-encoded ultra-low-field magnetic resonance imaging (ULF MRI) enabling current density imaging (CDI) and possibly conductivity map** of human head tissues. Since currents applied to a human are limited by safety regulations and only a small fraction of the current passes through the re…
▽ More
Magnetic fields associated with currents flowing in tissue can be measured non-invasively by means of zero-field-encoded ultra-low-field magnetic resonance imaging (ULF MRI) enabling current density imaging (CDI) and possibly conductivity map** of human head tissues. Since currents applied to a human are limited by safety regulations and only a small fraction of the current passes through the relatively high-resistive skull, a sufficient signal-to-noise ratio (SNR) may be difficult to obtain when using this method. In this work, we study the relationship between the image SNR and the SNR of the field reconstructions from zero-field-encoded data. We evaluate these results for two existing ULF MRI scanners, one ultra-sensitive single-channel system and one whole-head multi-channel system, by simulating sequences necessary for current-density reconstruction. We also derive realistic current-density and magnetic-field estimates from finite-element-method simulations based on a three-compartment head model. We found that existing ULF-MRI systems reach sufficient SNR to detect intra-cranial current distributions with statistical uncertainty below 10%. However, they also reveal that image artifacts influence the reconstruction quality. Further, our simulations indicate that current-density reconstruction in the scalp requires a resolution less than 5 mm and demonstrate that the necessary sensitivity coverage can be accomplished by multi-channel devices.
△ Less
Submitted 20 January, 2020;
originally announced January 2020.
-
Sampling theory for spatial field sensing: Application to electro- and magnetoencephalography
Authors:
Joonas Iivanainen,
Antti Mäkinen,
Rasmus Zetter,
Matti Stenroos,
Risto J. Ilmoniemi,
Lauri Parkkonen
Abstract:
We present a theoretical framework for analyzing spatial sampling of fields in three-dimensional space. The framework bridges Shannon's sampling and information theory to Bayesian probabilistic inference and experimental design. Based on the theory, we present an approach for optimal sampling on curved surfaces and analyze spatial sampling of EEG as well as that of on- and off-scalp MEG. Our spati…
▽ More
We present a theoretical framework for analyzing spatial sampling of fields in three-dimensional space. The framework bridges Shannon's sampling and information theory to Bayesian probabilistic inference and experimental design. Based on the theory, we present an approach for optimal sampling on curved surfaces and analyze spatial sampling of EEG as well as that of on- and off-scalp MEG. Our spatial-frequency analysis of simulated measurements shows that the available spatial degrees of freedom in the electric potential are limited by the smoothing due to head tissues, while those in the magnetic field are limited by the measurement distance. On-scalp MEG would generally benefit from three times more samples than EEG or off-scalp MEG. Assuming uniform whole-head sampling and similar signal-to-noise ratios, on-scalp MEG has the highest total information content among these modalities. If the number of spatial samples is small, nonuniform sampling can be beneficial.
△ Less
Submitted 11 December, 2019;
originally announced December 2019.
-
Automatic Spatial Calibration of Ultra-Low-Field MRI for High-Accuracy Hybrid MEG--MRI
Authors:
Antti J. Mäkinen,
Koos C. J. Zevenhoven,
Risto J. Ilmoniemi
Abstract:
With a hybrid MEG--MRI device that uses the same sensors for both modalities, the co-registration of MRI and MEG data can be replaced by an automatic calibration step. Based on the highly accurate signal model of ultra-low-field (ULF) MRI, we introduce a calibration method that eliminates the error sources of traditional co-registration. The signal model includes complex sensitivity profiles of th…
▽ More
With a hybrid MEG--MRI device that uses the same sensors for both modalities, the co-registration of MRI and MEG data can be replaced by an automatic calibration step. Based on the highly accurate signal model of ultra-low-field (ULF) MRI, we introduce a calibration method that eliminates the error sources of traditional co-registration. The signal model includes complex sensitivity profiles of the superconducting pickup coils. In ULF MRI, the profiles are independent of the sample and therefore well-defined. In the most basic form, the spatial information of the profiles, captured in parallel ULF-MR acquisitions, is used to find the exact coordinate transformation required. We assessed our calibration method by simulations assuming a helmet-shaped pickup-coil-array geometry. Using a carefully constructed objective function and sufficient approximations, even with low-SNR images, sub-voxel and sub-millimeter calibration accuracy was achieved. After the calibration, distortion-free MRI and high spatial accuracy for MEG source localization can be achieved. For an accurate sensor-array geometry, the co-registration and associated errors are eliminated, and the positional error can be reduced to a negligible level.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Superconducting receiver arrays for magnetic resonance imaging
Authors:
Koos C. J. Zevenhoven,
Antti J. Mäkinen,
Risto J. Ilmoniemi
Abstract:
Superconducting QUantum-Interference Devices (SQUIDs) make magnetic resonance imaging (MRI) possible in ultra-low microtesla-range magnetic fields. In this work, we investigate the design parameters affecting the signal and noise performance of SQUID-based sensors and multichannel magnetometers for MRI of the brain. Besides sensor intrinsics, various noise sources along with the size, geometry and…
▽ More
Superconducting QUantum-Interference Devices (SQUIDs) make magnetic resonance imaging (MRI) possible in ultra-low microtesla-range magnetic fields. In this work, we investigate the design parameters affecting the signal and noise performance of SQUID-based sensors and multichannel magnetometers for MRI of the brain. Besides sensor intrinsics, various noise sources along with the size, geometry and number of superconducting detector coils are important factors affecting the image quality. We derive figures of merit based on optimal combination of multichannel data, analyze different sensor array designs, and provide tools for understanding the signal detection and the different noise mechanisms. The work forms a guide to making design decisions for both imagingand sensor-oriented readers.
△ Less
Submitted 15 January, 2020; v1 submitted 22 May, 2018;
originally announced May 2018.