An instrumented baffle for the Advanced Virgo Input Mode Cleaner End Mirror
Authors:
M. Andres-Carcasona,
O. Ballester,
O. Blanch,
J. Campos,
G. Caneva,
L. Cardiel,
M. Cavalli-Sforza,
P. Chiggiato,
A. Chiummo,
J. A. Ferreira,
J. M. Illa,
C. Karathanasis,
M. Kolstein,
M. Martinez,
A. Macquet,
A. Menendez-Vazquez,
Ll. M. Mir,
J. Mundet,
A. Pasqualetti,
O. Piccinni,
C. Pio,
A. Romero-Rodriguez,
D. Serrano,
V. Dattilo
Abstract:
A novel instrumented baffle surrounding the suspended end mirror in the input mode cleaner cavity of the Virgo interferometer was installed in spring 2021. Since then, the device has been regularly operated in the experiment and the obtained results indicate a good agreement with simulations of the stray light inside the optical cavity. The baffle will operate in the upcoming O4 observation run, s…
▽ More
A novel instrumented baffle surrounding the suspended end mirror in the input mode cleaner cavity of the Virgo interferometer was installed in spring 2021. Since then, the device has been regularly operated in the experiment and the obtained results indicate a good agreement with simulations of the stray light inside the optical cavity. The baffle will operate in the upcoming O4 observation run, serving as a demonstrator of the technology designed to instrument the baffles in front of the main mirrors in time for O5. In this paper we present a detailed description of the baffle design, including mechanics, front-end electronics, data acquisition, as well as optical and vacuum tests, calibration and installation procedures, and performance results.
△ Less
Submitted 16 June, 2023; v1 submitted 27 October, 2022;
originally announced October 2022.
-
Light-Trap: A SiPM Upgrade for Very High Energy Astronomy and Beyond
Authors:
D. Guberman,
J. Cortina,
J. E. Ward,
A. Hahn,
D. Mazin,
J. Boix,
A. Dettlaff,
D. Fink,
J. Gaweda,
W. Haberer,
J. Illa,
J. Mundet,
Y. Vera,
H. Wetteskind
Abstract:
With the development of the Imaging Atmospheric Cherenkov Technique (IACT), Gamma-ray astronomy has become one of the most interesting and productive fields of astrophysics. Current IACT telescope arrays (MAGIC, H.E.S.S, VERITAS) use photomultiplier tubes (PMTs) to detect the optical/near-UV Cherenkov radiation emitted due to the interaction of gamma rays with the atmosphere. For the next generati…
▽ More
With the development of the Imaging Atmospheric Cherenkov Technique (IACT), Gamma-ray astronomy has become one of the most interesting and productive fields of astrophysics. Current IACT telescope arrays (MAGIC, H.E.S.S, VERITAS) use photomultiplier tubes (PMTs) to detect the optical/near-UV Cherenkov radiation emitted due to the interaction of gamma rays with the atmosphere. For the next generation of IACT experiments, the possibility of replacing the PMTs with Silicon photomultipliers (SiPMs) is being studied. Among the main drawbacks of SiPMs are their limited active area (leading to an increase in the cost and complexity of the camera readout) and their sensitivity to unwanted wavelengths. Here we propose a novel method to build a relatively low-cost pixel consisting of a SiPM attached to a PMMA disc doped with a wavelength shifter. This pixel collects light over a much larger area than a single standard SiPM and improves sensitivity to near-UV light while simultaneously rejecting background. We describe the design of a detector that could also have applications in other fields where detection area and cost are crucial. We present results of simulations and laboratory measurements of a pixel prototype and from field tests performed with a 7-pixel cluster installed in a MAGIC telescope camera.
△ Less
Submitted 1 September, 2017;
originally announced September 2017.
-
Towards SiPM camera for current and future generations of Cherenkov telescopes
Authors:
Daniel Mazin,
Priyadarshini Bangale,
Julian Sitarek,
Juan Cortina,
David Fink,
Jürgen Hose,
Jose Maria Illa,
Eckart Lorenz,
Manel Martínez,
Uta Menzel,
Razmik Mirzoyan,
Masahiro Teshima
Abstract:
So far the current ground-based Imaging Atmospheric Cherenkov Telescopes (IACTs) have energy thresholds in the best case in the range of ~30 to 50 GeV (H.E.S.S. II and MAGIC telescopes). Lowest energy gamma-ray showers produce low light intensity images and cannot be efficiently separated from dominating images from hadronic background. A cost effective way of improving the telescope performance a…
▽ More
So far the current ground-based Imaging Atmospheric Cherenkov Telescopes (IACTs) have energy thresholds in the best case in the range of ~30 to 50 GeV (H.E.S.S. II and MAGIC telescopes). Lowest energy gamma-ray showers produce low light intensity images and cannot be efficiently separated from dominating images from hadronic background. A cost effective way of improving the telescope performance at lower energies is to use novel photosensors with superior photon detection efficiency (PDE). Currently the best commercially available superbialkali photomultipliers (PMTs) have a PDE of about 30-33%, whereas the silicon photomultipliers (SiPMs, also known as MPPC, GAPD) from some manufacturers show a photon detection efficiency of about 40-45%. Using these devices can lower the energy threshold of the instrument and may improve the background rejection due to intrinsic properties of SiPMs such as a superb single photoelectron resolution. Compared to PMTs, SiPMs are more compact, fast in response, operate at low voltage, and are insensitive to magnetic fields. SiPMs can be operated at high background illumination, which would allow to operate the IACT also during partial moonlight, dusk and dawn, hence increasing the instrument duty cycle. We are testing the SiPMs for Cherenkov telescopes such as MAGIC and CTA. Here we present an overview of our setup and first measurements, which we perform in two independent laboratories, in Munich, Germany and in Barcelona, Spain.
△ Less
Submitted 19 October, 2014;
originally announced October 2014.
-
Development and Characterization of a Multi-APD Xenon Electroluminescence TPC
Authors:
T. Lux,
A. Garcia Soto,
O. Ballester,
S. Bordoni,
I. Gil-Botella,
N. Hamer,
J. Illa,
G. Jover Mañas,
C. Martin-Mari,
C. Palomares,
J. Rico,
F. Sanchez,
R. Santorelli,
A. Verdugo
Abstract:
The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the data yielding energy resolutions as good as 5.3$\pm$0.1 \% FWHM for 59.5 keV gammas from $^{241}$Am. This result was reproduced with a Monte Carlo (MC) based o…
▽ More
The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the data yielding energy resolutions as good as 5.3$\pm$0.1 \% FWHM for 59.5 keV gammas from $^{241}$Am. This result was reproduced with a Monte Carlo (MC) based on Geant4 and Penelope which predicted 5.2 \% FWHM for the used setup. Point resolutions of $\approx 0.5$ mm were obtained with a pitch of 15 mm between the APDs. These results show that multi-APD readout is a competitive technology for EL detectors filled with pure xenon.
△ Less
Submitted 18 December, 2014; v1 submitted 30 September, 2014;
originally announced September 2014.
-
A Multi-APD readout for EL detectors
Authors:
T. Lux,
O. Ballester,
J. Illa,
G. Jover,
C. Martin,
J. Rico,
F. Sanchez
Abstract:
Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma cameras, etc. In the following the study of a readout based on avalanche photo diodes to detect directly the VUV photons is presented. Results of measurements with…
▽ More
Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma cameras, etc. In the following the study of a readout based on avalanche photo diodes to detect directly the VUV photons is presented. Results of measurements with 5 APDs in xenon at pressures between 1 and 1.65 bar are shown indicating that such a readout can provide excellent energy and a moderate position resolution.
△ Less
Submitted 3 February, 2011;
originally announced February 2011.