-
The Belle II Detector Upgrades Framework Conceptual Design Report
Authors:
H. Aihara,
A. Aloisio,
D. P. Auguste,
M. Aversano,
M. Babeluk,
S. Bahinipati,
Sw. Banerjee,
M. Barbero,
J. Baudot,
A. Beaubien,
F. Becherer,
T. Bergauer,
F. U. Bernlochner.,
V. Bertacchi,
G. Bertolone,
C. Bespin,
M. Bessner,
S. Bettarini,
A. J. Bevan,
B. Bhuyan,
M. Bona,
J. F. Bonis,
J. Borah,
F. Bosi,
R. Boudagga
, et al. (186 additional authors not shown)
Abstract:
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit…
▽ More
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.
△ Less
Submitted 4 July, 2024; v1 submitted 26 June, 2024;
originally announced June 2024.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Supernova Model Discrimination with Hyper-Kamiokande
Authors:
Hyper-Kamiokande Collaboration,
:,
K. Abe,
P. Adrich,
H. Aihara,
R. Akutsu,
I. Alekseev,
A. Ali,
F. Ameli,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
A. Araya,
Y. Asaoka,
Y. Ashida,
V. Aushev,
F. Ballester,
I. Bandac,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz-Kwasniak,
M. Bellato,
V. Berardi,
M. Bergevin
, et al. (478 additional authors not shown)
Abstract:
Core-collapse supernovae are among the most magnificent events in the observable universe. They produce many of the chemical elements necessary for life to exist and their remnants -- neutron stars and black holes -- are interesting astrophysical objects in their own right. However, despite millennia of observations and almost a century of astrophysical study, the explosion mechanism of core-colla…
▽ More
Core-collapse supernovae are among the most magnificent events in the observable universe. They produce many of the chemical elements necessary for life to exist and their remnants -- neutron stars and black holes -- are interesting astrophysical objects in their own right. However, despite millennia of observations and almost a century of astrophysical study, the explosion mechanism of core-collapse supernovae is not yet well understood. Hyper-Kamiokande is a next-generation neutrino detector that will be able to observe the neutrino flux from the next galactic core-collapse supernova in unprecedented detail. We focus on the first 500 ms of the neutrino burst, corresponding to the accretion phase, and use a newly-developed, high-precision supernova event generator to simulate Hyper-Kamiokande's response to five different supernova models. We show that Hyper-Kamiokande will be able to distinguish between these models with high accuracy for a supernova at a distance of up to 100 kpc. Once the next galactic supernova happens, this ability will be a powerful tool for guiding simulations towards a precise reproduction of the explosion mechanism observed in nature.
△ Less
Submitted 20 July, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
Performance evaluation of the aerogel RICH counter for the Belle II spectrometer using early beam collision data
Authors:
M. Yonenaga,
I. Adachi,
L. Burmistrov,
F. Le Diberder,
T. Iijima,
S. Iwata,
S. Kakimoto,
H. Kakuno,
G. Karyan,
H. Kawai,
T. Kawasaki,
H. Kindo,
H. Kitamura,
M. Kobayashi,
T. Kohriki,
T. Konno,
S. Korpar,
P. Križan,
T. Kumita,
K. Kuze,
Y. Lai,
M. Mrvar,
G. Nazaryan,
S. Nishida,
M. Nishimura
, et al. (10 additional authors not shown)
Abstract:
The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluat…
▽ More
The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluate the performance of the ARICH counter using early beam collision data. Event samples of $D^{\ast +} \to D^0 π^+ (D^0 \to K^-π^+)$ were used to determine the $π(K)$ efficiency and the $K(π)$ misidentification probability. We found that the ARICH counter is capable of separating kaons from pions with an identification efficiency of $93.5 \pm 0.6 \, \%$ at a pion misidentification probability of $10.9 \pm 0.9 \, \%$. This paper describes the identification method of the counter and the evaluation of the performance during its early operation.
△ Less
Submitted 14 August, 2020;
originally announced August 2020.
-
Study of muonium emission from laser-ablated silica aerogel
Authors:
J. Beare,
G. Beer,
J. H. Brewer,
T. Iijima,
K. Ishida,
M. Iwasaki,
S. Kamal,
K. Kanamori,
N. Kawamura,
R. Kitamura,
S. Li,
G. M. Luke,
G. M. Marshall,
T. Mibe,
Y. Miyake,
Y. Oishi,
K. Olchanski,
A. Olin,
M. Otani,
M. A. Rehman,
N. Saito,
Y. Sato,
K. Shimomura,
K. Suzuki,
M. Tabata
, et al. (1 additional authors not shown)
Abstract:
The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some…
▽ More
The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some extreme conditions. The measured emission rate tends to be higher for larger fractions of ablation opening and for shallower depths. More than a few ablation structures reach the emission rates similar to the highest achieved in the past measurements. The emission rate is found to be stable at least for a couple of days. Measurements of spin precession amplitudes for the produced muonium atoms and remaining muons in a magnetic field determine a muonium formation fraction of $(65.5 \pm 1.8)$%. The precession of the polarized muonium atoms is also observed clearly in vacuum. A projection of the emission rates measured at TRIUMF to the corresponding rates at J-PARC is demonstrated taking the different beam condition into account reasonably.
△ Less
Submitted 1 September, 2020; v1 submitted 2 June, 2020;
originally announced June 2020.
-
Compact buncher cavity for muons accelerated by a radio-frequency quadrupole
Authors:
M. Otani,
Y. Sue,
K. Futatsukawa,
T. Iijima,
H. Iinuma,
N. Kawamura,
R. Kitamura,
Y. Kondo,
T. Morishita,
Y. Nakazawa,
H. Yasuda,
M. Yotsuzuka,
N. Saito,
T. Yamazaki
Abstract:
A buncher cavity has been developed for the muons accelerated by a radio-frequency quadrupole linac (RFQ). The buncher cavity is designed for $β=v/c=0.04$ at an operational frequency of 324 MHz. It employs a double-gap structure operated in the TEM mode for the required effective voltage with compact dimensions, in order to account for the limited space of the experiment. The measured resonant fre…
▽ More
A buncher cavity has been developed for the muons accelerated by a radio-frequency quadrupole linac (RFQ). The buncher cavity is designed for $β=v/c=0.04$ at an operational frequency of 324 MHz. It employs a double-gap structure operated in the TEM mode for the required effective voltage with compact dimensions, in order to account for the limited space of the experiment. The measured resonant frequency and unloaded quality factor are 323.95 MHz and $3.06\times10^3$, respectively. The buncher cavity was successfully operated for longitudinal bunch size measurement of the muons accelerated by the RFQ.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment
Authors:
M. Abe,
S. Bae,
G. Beer,
G. Bunce,
H. Choi,
S. Choi,
M. Chung,
W. da Silva,
S. Eidelman,
M. Finger,
Y. Fukao,
T. Fukuyama,
S. Haciomeroglu,
K. Hasegawa,
K. Hayasaka,
N. Hayashizaki,
H. Hisamatsu,
T. Iijima,
H. Iinuma,
K. Inami,
H. Ikeda,
M. Ikeno,
K. Ishida,
T. Itahashi,
M. Iwasaki
, et al. (71 additional authors not shown)
Abstract:
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon…
▽ More
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.
△ Less
Submitted 10 March, 2019; v1 submitted 10 January, 2019;
originally announced January 2019.
-
Hyper-Kamiokande Design Report
Authors:
Hyper-Kamiokande Proto-Collaboration,
:,
K. Abe,
Ke. Abe,
H. Aihara,
A. Aimi,
R. Akutsu,
C. Andreopoulos,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
Y. Ashida,
V. Aushev,
M. Barbi,
G. J. Barker,
G. Barr,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
L. Berns,
T. Berry,
S. Bhadra,
D. Bravo-Berguño,
F. d. M. Blaszczyk
, et al. (291 additional authors not shown)
Abstract:
On the strength of a double Nobel prize winning experiment (Super)Kamiokande and an extremely successful long baseline neutrino programme, the third generation Water Cherenkov detector, Hyper-Kamiokande, is being developed by an international collaboration as a leading worldwide experiment based in Japan. The Hyper-Kamiokande detector will be hosted in the Tochibora mine, about 295 km away from th…
▽ More
On the strength of a double Nobel prize winning experiment (Super)Kamiokande and an extremely successful long baseline neutrino programme, the third generation Water Cherenkov detector, Hyper-Kamiokande, is being developed by an international collaboration as a leading worldwide experiment based in Japan. The Hyper-Kamiokande detector will be hosted in the Tochibora mine, about 295 km away from the J-PARC proton accelerator research complex in Tokai, Japan. The currently existing accelerator will be steadily upgraded to reach a MW beam by the start of the experiment. A suite of near detectors will be vital to constrain the beam for neutrino oscillation measurements. A new cavern will be excavated at the Tochibora mine to host the detector. The experiment will be the largest underground water Cherenkov detector in the world and will be instrumented with new technology photosensors, faster and with higher quantum efficiency than the ones in Super-Kamiokande. The science that will be developed will be able to shape the future theoretical framework and generations of experiments. Hyper-Kamiokande will be able to measure with the highest precision the leptonic CP violation that could explain the baryon asymmetry in the Universe. The experiment also has a demonstrated excellent capability to search for proton decay, providing a significant improvement in discovery sensitivity over current searches for the proton lifetime. The atmospheric neutrinos will allow to determine the neutrino mass ordering and, together with the beam, able to precisely test the three-flavour neutrino oscillation paradigm and search for new phenomena. A strong astrophysical programme will be carried out at the experiment that will detect supernova neutrinos and will measure precisely solar neutrino oscillation.
△ Less
Submitted 28 November, 2018; v1 submitted 9 May, 2018;
originally announced May 2018.
-
First muon acceleration using a radio frequency accelerator
Authors:
S. Bae,
H. Choi,
S. Choi,
Y. Fukao,
K. Futatsukawa,
K. Hasegawa,
T. Iijima,
H. Iinuma,
K. Ishida,
N. Kawamura,
B. Kim,
R. Kitamura,
H. S. Ko,
Y. Kondo,
S. Li,
T. Mibe,
Y. Miyake,
T. Morishita,
Y. Nakazawa,
M. Otani,
G. P. Razuvaev,
N. Saito,
K. Shimomura,
Y. Sue,
E. Won
, et al. (1 additional authors not shown)
Abstract:
Muons have been accelerated by using a radio frequency accelerator for the first time. Negative muonium atoms (Mu$^-$), which are bound states of positive muons ($μ^+$) and two electrons, are generated from $μ^+$'s through the electron capture process in an aluminum degrader. The generated Mu$^-$'s are initially electrostatically accelerated and injected into a radio frequency quadrupole linac (RF…
▽ More
Muons have been accelerated by using a radio frequency accelerator for the first time. Negative muonium atoms (Mu$^-$), which are bound states of positive muons ($μ^+$) and two electrons, are generated from $μ^+$'s through the electron capture process in an aluminum degrader. The generated Mu$^-$'s are initially electrostatically accelerated and injected into a radio frequency quadrupole linac (RFQ). In the RFQ, the Mu$^-$'s are accelerated to 89 keV. The accelerated Mu$^-$'s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.
△ Less
Submitted 21 March, 2018;
originally announced March 2018.
-
Physics Potentials with the Second Hyper-Kamiokande Detector in Korea
Authors:
Hyper-Kamiokande proto-collaboration,
:,
K. Abe,
Ke. Abe,
S. H. Ahn,
H. Aihara,
A. Aimi,
R. Akutsu,
C. Andreopoulos,
I. Anghel,
L. H. V. Anthony,
M. Antonova,
Y. Ashida,
V. Aushev,
M. Barbi,
G. J. Barker,
G. Barr,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
L. Berns,
T. Berry,
S. Bhadra,
D. Bravo-Bergu no
, et al. (331 additional authors not shown)
Abstract:
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are sev…
▽ More
Hyper-Kamiokande consists of two identical water-Cherenkov detectors of total 520~kt with the first one in Japan at 295~km from the J-PARC neutrino beam with 2.5$^{\textrm{o}}$ Off-Axis Angles (OAAs), and the second one possibly in Korea in a later stage. Having the second detector in Korea would benefit almost all areas of neutrino oscillation physics mainly due to longer baselines. There are several candidate sites in Korea with baselines of 1,000$\sim$1,300~km and OAAs of 1$^{\textrm{o}}$$\sim$3$^{\textrm{o}}$. We conducted sensitivity studies on neutrino oscillation physics for a second detector, either in Japan (JD $\times$ 2) or Korea (JD + KD) and compared the results with a single detector in Japan. Leptonic CP violation sensitivity is improved especially when the CP is non-maximally violated. The larger matter effect at Korean candidate sites significantly enhances sensitivities to non-standard interactions of neutrinos and mass ordering determination. Current studies indicate the best sensitivity is obtained at Mt. Bisul (1,088~km baseline, $1.3^\circ$ OAA). Thanks to a larger (1,000~m) overburden than the first detector site, clear improvements to sensitivities for solar and supernova relic neutrino searches are expected.
△ Less
Submitted 26 March, 2018; v1 submitted 18 November, 2016;
originally announced November 2016.
-
Particle identification performance of the prototype Aerogel RICH counter for the Belle II experiment
Authors:
S. Iwata,
I. Adachi,
K. Hara,
T. Iijima,
H. Ikeda,
H. Kakuno,
H. Kawai,
T. Kawasaki,
S. Korpar,
P. Krizan,
T. Kumita,
S. Nishida,
S. Ogawa,
R. Pestotnik,
L. Šantelj,
A. Seljak,
M. Tabata,
E. Tahirović,
Y. Yusa
Abstract:
We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons, Hybrid Avalanche Photo-Detectors (HAPDs) are used. The designed HAPD has a high sensitivity to single photons under a strong magnetic field. We have confirmed t…
▽ More
We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons, Hybrid Avalanche Photo-Detectors (HAPDs) are used. The designed HAPD has a high sensitivity to single photons under a strong magnetic field. We have confirmed that the HAPD provides high efficiency for single-photon detection even after exposure to neutron and gamma-ray radiation that exceeds the levels expected in the 10-year Belle II operation. In order to confirm the basic performance of the ARICH counter system, we carried out a beam test at the DESY using a prototype of the ARICH counter with six HAPD modules. The results are in agreement with our expectations and confirm the suitability of the ARICH counter for the Belle II experiment. Based on the in-beam performance of the device, we expect that the identification efficiency at 3.5 GeV/c is 97.4% and 4.9% for pions and kaons, respectively. This paper summarizes the development of the HAPD for the ARICH and the evaluation of the performance of the prototype ARICH counter built with the final design components.
△ Less
Submitted 8 March, 2016;
originally announced March 2016.
-
A Long Baseline Neutrino Oscillation Experiment Using J-PARC Neutrino Beam and Hyper-Kamiokande
Authors:
Hyper-Kamiokande Working Group,
:,
K. Abe,
H. Aihara,
C. Andreopoulos,
I. Anghel,
A. Ariga,
T. Ariga,
R. Asfandiyarov,
M. Askins,
J. J. Back,
P. Ballett,
M. Barbi,
G. J. Barker,
G. Barr,
F. Bay,
P. Beltrame,
V. Berardi,
M. Bergevin,
S. Berkman,
T. Berry,
S. Bhadra,
F. d. M. Blaszczyk,
A. Blondel,
S. Bolognesi
, et al. (224 additional authors not shown)
Abstract:
Hyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of $CP$ asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams.
In this document, the physics potential o…
▽ More
Hyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of $CP$ asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams.
In this document, the physics potential of a long baseline neutrino experiment using the Hyper-Kamiokande detector and a neutrino beam from the J-PARC proton synchrotron is presented. The analysis has been updated from the previous Letter of Intent [K. Abe et al., arXiv:1109.3262 [hep-ex]], based on the experience gained from the ongoing T2K experiment. With a total exposure of 7.5 MW $\times$ 10$^7$ sec integrated proton beam power (corresponding to $1.56\times10^{22}$ protons on target with a 30 GeV proton beam) to a $2.5$-degree off-axis neutrino beam produced by the J-PARC proton synchrotron, it is expected that the $CP$ phase $δ_{CP}$ can be determined to better than 19 degrees for all possible values of $δ_{CP}$, and $CP$ violation can be established with a statistical significance of more than $3\,σ$ ($5\,σ$) for $76%$ ($58%$) of the $δ_{CP}$ parameter space.
△ Less
Submitted 18 January, 2015; v1 submitted 15 December, 2014;
originally announced December 2014.
-
Silica aerogel radiator for use in the A-RICH system utilized in the Belle II experiment
Authors:
Makoto Tabata,
Ichiro Adachi,
Nao Hamada,
Koji Hara,
Toru Iijima,
Shuichi Iwata,
Hidekazu Kakuno,
Hideyuki Kawai,
Samo Korpar,
Peter Križan,
Tetsuro Kumita,
Shohei Nishida,
Satoru Ogawa,
Rok Pestotnik,
Luka Šantelj,
Andrej Seljak,
Takayuki Sumiyoshi,
Elvedin Tahirović,
Keisuke Yoshida,
Yosuke Yusa
Abstract:
This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward end cap of the Belle II detector. The proximity-focusing A-RICH system is especially designed to identify charged kaons and pions. The refractive index of the in…
▽ More
This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward end cap of the Belle II detector. The proximity-focusing A-RICH system is especially designed to identify charged kaons and pions. The refractive index of the installed aerogel Cherenkov radiators is approximately 1.05, and we aim for a separation capability exceeding 4$σ$ at momenta up to 4 GeV/$c$. Large-area aerogel tiles (over 18 $\times $ 18 $\times $ 2 cm$^3$) were first fabricated in test productions by pin drying in addition to conventional methods. We proposed to fill the large end-cap region (area 3.5 m$^2$) with 124 water-jet-trimmed fan-shaped dual-layer-focusing aerogel combinations of different refractive indices (1.045 and 1.055). Guided by the test production results, we decided to manufacture aerogels by the conventional method and are currently proceeding with mass production. In an electron beam test undertaken at the DESY, we confirmed that the $K$/$π$ separation capability of a prototype A-RICH counter exceeded 4$σ$ at 4 GeV/$c$.
△ Less
Submitted 17 June, 2014;
originally announced June 2014.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
Measurements of Cherenkov Photons with Silicon Photomultipliers
Authors:
S. Korpar,
I. Adachi,
H. Chagani,
R. Dolenec,
K. Hara,
T. Iijima,
P. Krizan,
S. Nishida,
R. Pestotnik,
A. Stanovnik
Abstract:
A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which the…
▽ More
A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which the use of SiPMs, microchannel plate photomultiplier tubes or hybrid avalanche photodetectors, rather than traditional Photomultiplier Tubes (PMTs) is essential due to the presence of high magnetic fields. In both experiments, SiPMs are found to compare favourably with PMTs, with higher photon detection rates per unit area. Through the use of hemispherical and truncated pyramid light guides to concentrate photons onto the active surface area, the light yield increases significantly. An estimate of the contribution to dark noise from false coincidences between SiPMs in an array is also presented.
△ Less
Submitted 2 December, 2008;
originally announced December 2008.
-
Development of Multi-Pixel Photon Counters
Authors:
M. Yokoyama,
T. Nobuhara,
M. Taguchi,
T. Nakaya,
T. Murakami,
T. Nakadaira,
K. Yoshimura,
K. Kawagoe,
Y. Tamura,
T. Iijima,
Y. Mazuka,
K. Miyabayashi,
S. Iba,
H. Miyata,
T. Takeshita
Abstract:
The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and capability of operating in magnetic fields and in room temperature. The basic performance of samples has been measured. A gain of ~10^6 is achieved with a noise r…
▽ More
The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and capability of operating in magnetic fields and in room temperature. The basic performance of samples has been measured. A gain of ~10^6 is achieved with a noise rate less than 1 MHz with 1 p.e. threshold, and cross-talk probability of less than 30% at room temperature. The photon detection efficiency for green light is twice or more that of the photomultiplier tubes. It is found that the basic performance of the MPPC is satisfactory for use in real experiments.
△ Less
Submitted 29 May, 2006;
originally announced May 2006.
-
Study of a nonhomogeneous aerogel radiator in a proximity focusing RICH detector
Authors:
Peter Krizan,
Samo Korpar,
Toru Iijima
Abstract:
The use of a nonhomogeneous aerogel radiator, i.e. one consisting of layers with different refractive indices, has been shown to improve the resolution of the Cherenkov angle measured with a proximity focusing RICH detector. In order to obtain further information on the performance of such a detector, a simple model has been used to calculate the resolution and search for optimal radiator parame…
▽ More
The use of a nonhomogeneous aerogel radiator, i.e. one consisting of layers with different refractive indices, has been shown to improve the resolution of the Cherenkov angle measured with a proximity focusing RICH detector. In order to obtain further information on the performance of such a detector, a simple model has been used to calculate the resolution and search for optimal radiator parameters.
△ Less
Submitted 3 March, 2006;
originally announced March 2006.
-
A novel type of proximity focusing RICH counter with multiple refractive index aerogel radiator
Authors:
T. Iijima,
S. Korpar,
I. Adachi,
S. Fratina,
T. Fukushima,
A. Gorisek,
H. Kawai,
M. Konishi,
Y. Kozakai,
P. Krizan,
T. Matsumoto,
Y. Mazuka,
S. Nishida,
S. Ogawa,
S. Ohtake,
R. Pestotnik,
S. Saitoh,
T. Seki,
T. Sumiyoshi,
Y. Uchida,
Y. Unno,
S. Yamamoto
Abstract:
A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index aerogel radiator allows for an increase in Cherenkov photon yield on account of the increase in overall radiator thickness, while avoiding the simultaneous degrada…
▽ More
A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index aerogel radiator allows for an increase in Cherenkov photon yield on account of the increase in overall radiator thickness, while avoiding the simultaneous degradation in single photon angular resolution associated with the increased uncertainty of the emission point. With the refractive index of consecutive layers suitably increasing in the downstream direction, one may achieve overlap** of the Cherenkov rings from a single charged particle. In the opposite case of decreasing refractive index, one may obtain well separated rings. In the former combination an approximately 40% increase in photon yield is accompanied with just a minor degradation in single photon angular resolution. The impact of this improvement on the pion/kaon separation at the upgraded Belle detector is discussed.
△ Less
Submitted 29 April, 2005;
originally announced April 2005.
-
Development of a multi-pixel hybrid photo-detector with high quantum efficiency and gain
Authors:
M. Suyama,
A. Fukasawa,
J. Haba,
T. Iijima,
S. Iwata,
M. Sakuda,
T. Sumiyoshi,
F. Takasaki,
M. Tanaka,
T. Tsuboyama,
Y. Yamada
Abstract:
A hybrid photo-detector (HPD) consisting of a photocathode and a multi-pixel avalanche diode (MP-AD) was developed a few years ago. Our previous studies showed that its inherent potential for high resolution photon counting could be further enhanced by reducing fluctuations in charge loss in the dead layer at the entrance of the MP-AD. In this paper, we report on the improvement with the newly d…
▽ More
A hybrid photo-detector (HPD) consisting of a photocathode and a multi-pixel avalanche diode (MP-AD) was developed a few years ago. Our previous studies showed that its inherent potential for high resolution photon counting could be further enhanced by reducing fluctuations in charge loss in the dead layer at the entrance of the MP-AD. In this paper, we report on the improvement with the newly developed HPD whose encapsulated MP-AD has a thinner dead layer than before. It is demonstrated that the new HPD has much better energy resolution, which enables clearer counting up to nine photoelectrons. Further enhancement of the photocathode sensitivity of the HPD is also discussed.
△ Less
Submitted 26 February, 2004;
originally announced February 2004.
-
Development of a multi-pixel photon sensor with single-photon sensitivity
Authors:
Motohiro Suyama,
Atsuhito Fukasawa,
Junji Haba,
Toru Iijima,
Seigi Iwata,
Makoto Sakuda,
Takayuki Sumiyoshi,
Fumihiko Takasaki,
Manobu Tanaka,
Toru Tsuboyama,
Yoshikazu Yamada
Abstract:
A multi-pixel photon sensor with single-photon sensitivity has been developed, based on a technology of a hybrid photo-detector (HPD) consisting of a photocathode and a multi-pixel avalanche diode (MP-AD). The developed HPD has a proximity focused structure, where a photocathode and an MP-AD are facing each other with a small gap of 2.5 mm. The MP-AD, which has an effective area of 16x16 mm2 com…
▽ More
A multi-pixel photon sensor with single-photon sensitivity has been developed, based on a technology of a hybrid photo-detector (HPD) consisting of a photocathode and a multi-pixel avalanche diode (MP-AD). The developed HPD has a proximity focused structure, where a photocathode and an MP-AD are facing each other with a small gap of 2.5 mm. The MP-AD, which has an effective area of 16x16 mm2 composed of 8x8 pixels, has been specially designed for the HPD. The gain of the HPD reaches 5x10^4, sufficiently high to detect single photons with a timing resolution better than 100 ps. Number of photoelectrons up to four can be clearly identified in a pulse-height spectrum as distinct peaks, thanks to the low noise characteristics of the HPD. It is also demonstrated that the HPD can be operated with good performance in a magnetic field as high as 1.5 T
△ Less
Submitted 3 December, 2003;
originally announced December 2003.
-
Studies of Proximity Focusing RICH with an aerogel radiator using Flat-panel multi-anode PMTs (Hamamatsu H8500)
Authors:
T. Matsumoto,
S. Korpar,
I. Adachi,
S. Fratina,
T. Iijima,
R. Ishibashi,
H. Kawai,
P. Krizan,
S. Ogawa,
R. Pestotnik,
S. Saitoh,
T. Seki,
T. Sumiyoshi,
K. Suzuki,
T. Tabata,
Y. Uchida,
Y. Unno
Abstract:
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission le…
▽ More
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n=1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS pi2 beam line in November, 2002. To evaluate systematically the performance of the detector, tests were carried out with various aerogel samples using pion beams with momenta between 0.5 GeV/c and 4 GeV/c. The typical angular resolution was around 14 mrad, and the average number of detected photoelectrons was around 6. We expect that pions and kaons can be separated at a 4 sigma level at 4 GeV/c.
△ Less
Submitted 4 November, 2003; v1 submitted 4 September, 2003;
originally announced September 2003.