-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Design of the ECCE Detector for the Electron Ion Collider
Authors:
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin,
R. Capobianco
, et al. (259 additional authors not shown)
Abstract:
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent track…
▽ More
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. This detector concept has been selected to be the basis for the EIC project detector.
△ Less
Submitted 11 May, 2023; v1 submitted 6 September, 2022;
originally announced September 2022.
-
CORE -- a COmpact detectoR for the EIC
Authors:
CORE Collaboration,
R. Alarcon,
M. Baker,
V. Baturin,
P. Brindza,
S. Bueltmann,
M. Bukhari,
R. Capobianco,
E. Christy,
S. Diehl,
M. Dugger,
R. Dupré,
R. Dzhygadlo,
K. Flood,
K. Gnanvo,
L. Guo,
T. Hayward,
M. Hattawy,
M. Hoballah,
M. Hohlmann,
C. E. Hyde,
Y. Ilieva,
W. W. Jacobs,
K. Joo,
G. Kalicy
, et al. (34 additional authors not shown)
Abstract:
The COmpact detectoR for the Eic (CORE) Proposal was submitted to the EIC "Call for Collaboration Proposals for Detectors". CORE comprehensively covers the physics scope of the EIC Community White Paper and the National Academies of Science 2018 report. The design exploits advances in detector precision and granularity to minimize size. The central detector includes a 3Tesla, 2.5m solenoid. Tracki…
▽ More
The COmpact detectoR for the Eic (CORE) Proposal was submitted to the EIC "Call for Collaboration Proposals for Detectors". CORE comprehensively covers the physics scope of the EIC Community White Paper and the National Academies of Science 2018 report. The design exploits advances in detector precision and granularity to minimize size. The central detector includes a 3Tesla, 2.5m solenoid. Tracking is primarily silicon. Electromagnetic calorimetry is based on the high performance crystals. Ring-imaging Cherenkov detectors provide hadronic particle identification.
△ Less
Submitted 1 September, 2022;
originally announced September 2022.
-
Detector Requirements and Simulation Results for the EIC Exclusive, Diffractive and Tagging Physics Program using the ECCE Detector Concept
Authors:
A. Bylinkin,
C. T. Dean,
S. Fegan,
D. Gangadharan,
K. Gates,
S. J. D. Kay,
I. Korover,
W. B. Li,
X. Li,
R. Montgomery,
D. Nguyen,
G. Penman,
J. R. Pybus,
N. Santiesteban,
R. Trotta,
A. Usman,
M. D. Baker,
J. Frantz,
D. I. Glazier,
D. W. Higinbotham,
T. Horn,
J. Huang,
G. Huber,
R. Reed,
J. Roche
, et al. (258 additional authors not shown)
Abstract:
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fr…
▽ More
This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC's exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark-gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detecter system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirmed the proposed technology and design satisfy the requirements. The projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb^-1 of integrated luminosity. Additionally, a few insights on the potential 2nd Interaction Region can (IR) were also documented which could serve as a guidepost for the future development of a second EIC detector.
△ Less
Submitted 6 March, 2023; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Open Heavy Flavor Studies for the ECCE Detector at the Electron Ion Collider
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will…
▽ More
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will be presented. The ECCE detector has enabled precise EIC heavy flavor hadron and jet measurements with a broad kinematic coverage. These proposed heavy flavor measurements will help systematically study the hadronization process in vacuum and nuclear medium especially in the underexplored kinematic region.
△ Less
Submitted 23 July, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Exclusive J/$ψ$ Detection and Physics with ECCE
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the…
▽ More
Exclusive heavy quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. The momentum transfer dependence of this process is sensitive to the interaction sites, which provides a powerful tool to probe the spatial distribution of gluons in the nucleus. Recently the problem of the origin of hadron mass has received lots of attention in determining the anomaly contribution $M_{a}$. The trace anomaly is sensitive to the gluon condensate, and exclusive production of quarkonia such as J/$ψ$ and $Υ$ can serve as a sensitive probe to constrain it. In this paper, we present the performance of the ECCE detector for exclusive J/$ψ$ detection and the capability of this process to investigate the above physics opportunities with ECCE.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Design and Simulated Performance of Calorimetry Systems for the ECCE Detector at the Electron Ion Collider
Authors:
F. Bock,
N. Schmidt,
P. K. Wang,
N. Santiesteban,
T. Horn,
J. Huang,
J. Lajoie,
C. Munoz Camacho,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (263 additional authors not shown)
Abstract:
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key…
▽ More
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.
△ Less
Submitted 19 July, 2022;
originally announced July 2022.
-
AI-assisted Optimization of the ECCE Tracking System at the Electron Ion Collider
Authors:
C. Fanelli,
Z. Papandreou,
K. Suresh,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann
, et al. (258 additional authors not shown)
Abstract:
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to…
▽ More
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.
△ Less
Submitted 19 May, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Scientific Computing Plan for the ECCE Detector at the Electron Ion Collider
Authors:
J. C. Bernauer,
C. T. Dean,
C. Fanelli,
J. Huang,
K. Kauder,
D. Lawrence,
J. D. Osborn,
C. Paus,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (256 additional authors not shown)
Abstract:
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing thes…
▽ More
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. In this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.
△ Less
Submitted 17 May, 2022;
originally announced May 2022.
-
Measuring Recoiling Nucleons from the Nucleus with the Electron Ion Collider
Authors:
F. Hauenstein,
A. Jentsch,
J. R. Pybus,
A. Kiral,
M. D. Baker,
Y. Furletova,
O. Hen,
D. W. Higinbotham,
C. Hyde,
V. Morozov,
D. Romanov,
L. B. Weinstein
Abstract:
Short range correlated nucleon-nucleon ($NN$) pairs are an important part of the nuclear ground state. They are typically studied by scattering an electron from one nucleon in the pair and detecting its spectator correlated partner ("spectator-nucleon tagging"). The Electron Ion Collider (EIC) should be able to detect these nucleons, since they are boosted to high momentum in the lab frame by the…
▽ More
Short range correlated nucleon-nucleon ($NN$) pairs are an important part of the nuclear ground state. They are typically studied by scattering an electron from one nucleon in the pair and detecting its spectator correlated partner ("spectator-nucleon tagging"). The Electron Ion Collider (EIC) should be able to detect these nucleons, since they are boosted to high momentum in the lab frame by the momentum of the ion beam. To determine the feasibility of these studies with the planned EIC detector configuration, we have simulated quasi-elastic scattering for two electron and ion beam energy configurations: 5 GeV $e^{-}$ and 41 GeV/A ions, and 10 GeV $e^{-}$ and 110 GeV/A ions. We show that the knocked-out and recoiling nucleons can be detected over a wide range of initial nucleon momenta. We also show that these measurements can achieve much larger momentum transfers than current fixed target experiments. By detecting both low and high initial-momentum nucleons, the EIC will provide the data that should allow scientists to definitively show if the EMC effect and short-range correlation are connected, and to improve our understanding of color transparency.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
Design concept for the second interaction region for Electron-Ion Collider
Authors:
B. R. Gamage,
E. -C. Aschenauer,
J. S. Berg,
V. Burkert,
R. Ent,
Y. Furletova,
D. Higinbotham,
A. Hutton,
C. Hyde,
A. Jentsch,
A. Kiselev,
F. Lin,
T. Michalski,
C. Montag,
V. S. Morozov,
P. Nadel-Turonski,
R. Palmer,
B. Parker,
V. Ptitsyn,
R. Rajput-Ghoshal,
D. Romanov,
T. Satogata,
A. Seryi,
A. Sy,
C. Weiss
, et al. (5 additional authors not shown)
Abstract:
The possibility of two interaction regions (IRs) is a design requirement for the Electron Ion Collider (the EIC). There is also a significant interest from the nuclear physics community in a 2nd IR with measurements capabilities complementary to those of the first IR. While the 2nd IR will be in operation over the entire energy range of ~20GeV to ~140GeV center of mass (CM). The 2nd IR can also pr…
▽ More
The possibility of two interaction regions (IRs) is a design requirement for the Electron Ion Collider (the EIC). There is also a significant interest from the nuclear physics community in a 2nd IR with measurements capabilities complementary to those of the first IR. While the 2nd IR will be in operation over the entire energy range of ~20GeV to ~140GeV center of mass (CM). The 2nd IR can also provide an acceptance coverage complementary to that of the first. We present a brief overview and the current progress of the 2nd IR design in terms of the parameters, magnet layout, and beam dynamics.
△ Less
Submitted 20 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and develo** detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case
Authors:
E. Cisbani,
A. Del Dotto,
C. Fanelli,
M. Williams,
M. Alfred,
F. Barbosa,
L. Barion,
V. Berdnikov,
W. Brooks,
T. Cao,
M. Contalbrigo,
S. Danagoulian,
A. Datta,
M. Demarteau,
A. Denisov,
M. Diefenthaler,
A. Durum,
D. Fields,
Y. Furletova,
C. Gleason,
M. Grosse-Perdekamp,
M. Hattawy,
X. He,
H. van Hecke,
D. Higinbotham
, et al. (22 additional authors not shown)
Abstract:
Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. We propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development a…
▽ More
Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. We propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as part of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our approach can be applied to any detector R&D, provided that realistic simulations are available.
△ Less
Submitted 6 June, 2020; v1 submitted 13 November, 2019;
originally announced November 2019.
-
The PANDA DIRC Detectors at FAIR
Authors:
C. Schwarz,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
K. Goetzen,
G. Kalicy,
M. Krebs,
D. Lehmann,
F. Nerling,
M. Patsyuk,
K. Peters,
G. Schepers,
L. Schmitt,
J. Schwiening,
M. Traxler,
M. Zuehlsdorf,
M. Boehm,
A. Britting,
W. Eyrich,
A. Lehmann,
M. Pfaffinger,
F. Uhlig,
M. Dueren,
E. Etzelmueller
, et al. (17 additional authors not shown)
Abstract:
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22…
▽ More
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22 deg. to 140 deg. is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. The novel Endcap Disc DIRC will cover the smaller forward angles between 5 deg. (10 deg.) to 22 deg. in the vertical (horizontal) direction. Both DIRC counters will use lifetime-enhanced microchannel plate PMTs for photon detection in combination with fast readout electronics. Geant4 simulations and tests with several prototypes at various beam facilities have been used to evaluate the designs and validate the expected PID performance of both PANDA DIRC counters.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Production of highly-polarized positrons using polarized electrons at MeV energies
Authors:
D. Abbott,
P. Adderley,
A. Adeyemi,
P. Aguilera,
M. Ali,
H. Areti,
M. Baylac,
J. Benesch,
G. Bosson,
B. Cade,
A. Camsonne,
L. S. Cardman,
J. Clark,
P. Cole,
S. Covert,
C. Cuevas,
O. Dadoun,
D. Dale,
H. Dong,
J. Dumas,
E. Fanchini,
T. Forest,
E. Forman,
A. Freyberger,
E. Froidefond
, et al. (40 additional authors not shown)
Abstract:
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an…
▽ More
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an initial electron beam momentum of 8.19~MeV/$c$, limited only by the electron beam polarization. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community.
△ Less
Submitted 28 June, 2016;
originally announced June 2016.
-
MEIC Design Summary
Authors:
S. Abeyratne,
D. Barber,
A. Bogacz,
P. Brindza,
Y. Cai,
A. Camsonne,
A. Castilla,
P. Chevtsov,
E. Daly,
Y. S. Derbenev,
D. Douglas,
V. Dudnikov,
R. Ent,
B. Erdelyi,
Y. Filatov,
D. Gaskell,
J. Grames,
J. Guo,
L. Harwood,
A. Hutton,
C. Hyde,
K. Jordan,
A. Kimber,
G. A. Krafft,
A. Kondratenko
, et al. (30 additional authors not shown)
Abstract:
This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current infor…
▽ More
This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current information.
△ Less
Submitted 29 April, 2015;
originally announced April 2015.
-
Hall A Annual Report 2012
Authors:
S. Riordan,
C. Keppel,
K. Aniol,
J. Annand,
J. Arrington,
T. Averett,
C. Ayerbe Gayoso,
E. Brash,
G. D. Cates,
J. -P. Chen,
E. Chudakov,
D. Flay,
G. B. Franklin,
M. Friedman,
O. Glamazdin,
J. Gomez,
C. Hanretty,
J. -O. Hansen,
C. Hyde,
M. K. Jones,
I. Korover,
J. J. LeRose,
R. A. Lindgren,
N. Liyanage,
E. Long
, et al. (24 additional authors not shown)
Abstract:
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
△ Less
Submitted 18 February, 2013;
originally announced February 2013.
-
Science Requirements and Conceptual Design for a Polarized Medium Energy Electron-Ion Collider at Jefferson Lab
Authors:
S. Abeyratne,
A. Accardi,
S. Ahmed,
D. Barber,
J. Bisognano,
A. Bogacz,
A. Castilla,
P. Chevtsov,
S. Corneliussen,
W. Deconinck,
P. Degtiarenko,
J. Delayen,
Ya. Derbenev,
S. DeSilva,
D. Douglas,
V. Dudnikov,
R. Ent,
B. Erdelyi,
P. Evtushenko,
Yu. Filatov,
D. Gaskell,
R. Geng,
V. Guzey,
T. Horn,
A. Hutton
, et al. (33 additional authors not shown)
Abstract:
This report presents a brief summary of the science opportunities and program of a polarized medium energy electron-ion collider at Jefferson Lab and a comprehensive description of the conceptual design of such a collider based on the CEBAF electron accelerator facility.
This report presents a brief summary of the science opportunities and program of a polarized medium energy electron-ion collider at Jefferson Lab and a comprehensive description of the conceptual design of such a collider based on the CEBAF electron accelerator facility.
△ Less
Submitted 5 September, 2012; v1 submitted 4 September, 2012;
originally announced September 2012.