Skip to main content

Showing 1–24 of 24 results for author: Huth, L

Searching in archive physics. Search in all archives.
.
  1. arXiv:2403.08952  [pdf, other

    physics.ins-det

    Characterisation of analogue Monolithic Active Pixel Sensor test structures implemented in a 65 nm CMOS imaging process

    Authors: Gianluca Aglieri Rinella, Giacomo Alocco, Matias Antonelli, Roberto Baccomi, Stefania Maria Beole, Mihail Bogdan Blidaru, Bent Benedikt Buttwill, Eric Buschmann, Paolo Camerini, Francesca Carnesecchi, Marielle Chartier, Yongjun Choi, Manuel Colocci, Giacomo Contin, Dominik Dannheim, Daniele De Gruttola, Manuel Del Rio Viera, Andrea Dubla, Antonello di Mauro, Maurice Calvin Donner, Gregor Hieronymus Eberwein, Jan Egger, Laura Fabbietti, Finn Feindt, Kunal Gautam , et al. (69 additional authors not shown)

    Abstract: Analogue test structures were fabricated using the Tower Partners Semiconductor Co. CMOS 65 nm ISC process. The purpose was to characterise and qualify this process and to optimise the sensor for the next generation of Monolithic Active Pixels Sensors for high-energy physics. The technology was explored in several variants which differed by: do** levels, pixel geometries and pixel pitches (10-25… ▽ More

    Submitted 13 March, 2024; originally announced March 2024.

  2. Simulations and Performance Studies of a MAPS in 65 nm CMOS Imaging Technology

    Authors: Adriana Simancas, Justus Braach, Eric Buschmann, Ankur Chauhan, Dominik Dannheim, Manuel Del Rio Viera, Katharina Dort, Doris Eckstein, Finn Feindt, Ingrid-Maria Gregor, Karsten Hansen, Lennart Huth, Larissa Mendes, Budi Mulyanto, Daniil Rastorguev, Christian Reckleben, Sara Ruiz Daza, Judith Schlaadt, Paul Schütze, Walter Snoeys, Simon Spannagel, Marcel Stanitzki, Anastasiia Velyka, Gianpiero Vignola, Håkan Wennlöf

    Abstract: Monolithic active pixel sensors (MAPS) produced in a 65 nm CMOS imaging technology are being investigated for applications in particle physics. The MAPS design has a small collection electrode characterized by an input capacitance of ~fF, granting a high signal-to-noise ratio and low power consumption. Additionally, the 65 nm CMOS imaging technology brings a reduction in material budget and improv… ▽ More

    Submitted 22 February, 2024; originally announced February 2024.

    Comments: 6 pages, 5 figures, submitted to Nuclear Instruments and Methods in Physics Research, Section A as a conference proceeding for the 13th International "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors

  3. Develo** a Monolithic Silicon Sensor in a 65 nm CMOS Imaging Technology for Future Lepton Collider Vertex Detectors

    Authors: Adriana Simancas, Justus Braach, Eric Buschmann, Ankur Chauhan, Dominik Dannheim, Manuel Del Rio Viera, Katharina Dort, Doris Eckstein, Finn Feindt, Ingrid-Maria Gregor, Karsten Hansen, Lennart Huth, Larissa Mendes, Budi Mulyanto, Daniil Rastorguev, Christian Reckleben, Sara Ruiz Daza, Paul Schütze, Walter Snoeys, Simon Spannagel, Marcel Stanitzki, Anastasiia Velyka, Gianpiero Vignola, Håkan Wennlöf

    Abstract: Monolithic CMOS sensors in a 65 nm imaging technology are being investigated by the CERN EP Strategic R&D Programme on Technologies for Future Experiments for an application in particle physics. The appeal of monolithic detectors lies in the fact that both sensor volume and readout electronics are integrated in the same silicon wafer, providing a reduction in production effort, costs and scatterin… ▽ More

    Submitted 31 March, 2023; originally announced March 2023.

    Comments: 7 pages, 8 figures, submitted to IEEE Xplore as conference record for 2022 IEEE NSS/MIC/RTSD

  4. arXiv:2301.05909  [pdf, other

    physics.ins-det hep-ex

    ADENIUM -- A demonstrator for a next-generation beam telescope at DESY

    Authors: Yi Liu, Changqing Feng, Ingrid-Maria Gregor, Adrian Herkert, Lennart Huth, Marcel Stanitzki, Yao Teng, Chenfei Yang

    Abstract: High-resolution beam telescopes for charged particle tracking are one of the most important and equally demanding infrastructure items at test beam facilities. The main purpose of beam telescopes is to provide precise reference track information of beam particles to measure the performance of a device under test (DUT). In this report the development of the ADENIUM beam telescope (ALPIDE sensor bas… ▽ More

    Submitted 1 June, 2023; v1 submitted 14 January, 2023; originally announced January 2023.

    Comments: 11 pages, 8 figures

    Report number: PUBDB-2022-07438

  5. arXiv:2212.10248  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    TelePix -- A fast region of interest trigger and timing layer for the EUDET Telescopes

    Authors: Heiko Augustin, Sebastian Dittmeier, Jan Hammerich, Adrian Herkert, Lennart Huth, David Immig, Ivan Perić, André Schöning, Adriana Simancas, Marcel Stanitzki, Benjamin Weinläder

    Abstract: Test beam facilities are essential to study the response of novel detectors to particles. At the DESY II Test Beam facility, users can test their detectors with an electron beam with a momentum from 1-6 GeV. To track the beam particles, EUDET-style telescopes are provided in each beam area. They provide excellent spatial resolution, but the time resolution is limited by the rolling shutter archite… ▽ More

    Submitted 20 December, 2022; originally announced December 2022.

    Comments: Preprint submitted to Proceedings of the 15th Pisa Meeting on Advanced Detectors

  6. Towards a New Generation of Monolithic Active Pixel Sensors

    Authors: Ankur Chauhan, Manuel Del Rio Viera, Doris Eckstein, Finn Feindt, Ingrid-Maria Gregor, Karsten Hansen, Lennart Huth, Larissa Mendes, Budi Mulyanto, Daniil Rastorguev, Christian Reckleben, Sara Ruiz Daza, Paul Schütze, Adriana Simancas, Simon Spannagel, Marcel Stanitzki, Anastasiia Velyka, Gianpiero Vignola, Håkan Wennlöf

    Abstract: A new generation of Monolithic Active Pixel Sensors (MAPS), produced in a 65 nm CMOS imaging process, promises higher densities of on-chip circuits and, for a given pixel size, more sophisticated in-pixel logic compared to larger feature size processes. MAPS are a cost-effective alternative to hybrid pixel sensors since flip-chip bonding is not required. In addition, they allow for significant red… ▽ More

    Submitted 18 October, 2022; originally announced October 2022.

    Comments: 3 pages, 2 figures, presented at 15th Pisa Meeting on Advanced Detectors

    Journal ref: Nuclear Inst. and Methods in Physics Research, A 1047 (2023) 167821

  7. arXiv:2208.10827  [pdf, other

    physics.ins-det hep-ex

    Upgrading the Beam Telescopes at the DESY II Test Beam Facility

    Authors: H. Augustin, R. Diener, S. Dittmeier, P. M. Freeman, J. Hammerich, A. Herkert, L. Huth, D. Immig, U. Krämer, N. Meyners, I. Perić, O. Schäfer, A. Schöning, A. Simancas, M. Stanitzki, D. Stuart, B. Weinläder

    Abstract: The DESY II Test Beam Facility is a key infrastructure for modern high energy physics detector development, providing particles with a small momentum spread in a range from 1 to 6 GeV to user groups e.g. from the LHC experiments and Belle II as well as generic detector R&D. Beam telescopes are provided in all three test beam areas as precise tracking reference without time stam**, with triggered… ▽ More

    Submitted 23 August, 2022; originally announced August 2022.

    Journal ref: NIM-A 1040,167-183, 2022

  8. arXiv:2206.05474  [pdf, other

    physics.ins-det hep-ex

    The Tangerine project: Development of high-resolution 65 nm silicon MAPS

    Authors: Håkan Wennlöf, Ankur Chauhan, Manuel Del Rio Viera, Doris Eckstein, Finn Feindt, Ingrid-Maria Gregor, Karsten Hansen, Lennart Huth, Larissa Mendes, Budi Mulyanto, Daniil Rastorguev, Christian Reckleben, Sara Ruiz Daza, Paul Schütze, Adriana Simancas, Simon Spannagel, Marcel Stanitzki, Anastasiia Velyka, Gianpiero Vignola

    Abstract: The Tangerine project aims to develop new state-of-the-art high-precision silicon detectors. Part of the project has the goal of develo** a monolithic active pixel sensor using a novel 65 nm CMOS imaging process, with a small collection electrode. This is the first application of this process in particle physics, and it is of great interest as it allows for an increased logic density and reduced… ▽ More

    Submitted 11 June, 2022; originally announced June 2022.

    Comments: 5 pages, 5 figures. Proceedings of VCI 2022: The 16th Vienna Conference on Instrumentation, submitted to Nucl. Instrum. Methods Phys. Res. A

    Journal ref: Nuclear Inst. and Methods in Physics Research, A 1039C (2022) 167025

  9. Comparison of different sensor thicknesses and substrate materials for the monolithic small collection-electrode technology demonstrator CLICTD

    Authors: Katharina Dort, Rafael Ballabriga, Justus Braach, Eric Buschmann, Michael Campbell, Dominik Dannheim, Lennart Huth, Iraklis Kremastiotis, Jens Kröger, Lucie Linssen, Magdalena Munker, Walter Snoeys, Simon Spannagel, Peter Švihra, Tomas Vanat

    Abstract: Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high-resistivity epitaxial layers. In this paper, the active sensor depth is investigated in the monolithic small collection-electrode technology demonstrator CLICTD. Charged particle beams ar… ▽ More

    Submitted 30 August, 2022; v1 submitted 22 April, 2022; originally announced April 2022.

  10. arXiv:2202.03221  [pdf, other

    physics.ins-det hep-ex

    Transient Monte Carlo Simulations for the Optimisation and Characterisation of Monolithic Silicon Sensors

    Authors: Rafael Ballabriga, Justus Braach, Eric Buschmann, Michael Campbell, Dominik Dannheim, Katharina Dort, Lennart Huth, Iraklis Kremastiotis, Jens Kröger, Lucie Linssen, Magdalena Munker, Paul Schütze, Walter Snoeys, Simon Spannagel, Tomas Vanat

    Abstract: An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite element simulations with a transient Monte Carlo approach provides simultaneous access to precise sensor modelling and high statistics. The high simulation statistics enable the inclusion of Landau fluctuations and produc… ▽ More

    Submitted 9 February, 2022; v1 submitted 7 February, 2022; originally announced February 2022.

  11. arXiv:2102.04025  [pdf, other

    physics.ins-det hep-ex

    Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement

    Authors: R. Ballabriga, E. Buschmann, M. Campbell, D. Dannheim, K. Dort, N. Egidos, L. Huth, I. Kremastiotis, J. Kröger, L. Linssen, X. Llopart, M. Munker, A. Nürnberg, W. Snoeys, S. Spannagel, T. Vanat, M. Vicente, M. Williams

    Abstract: The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the trackin… ▽ More

    Submitted 8 February, 2021; originally announced February 2021.

  12. Corryvreckan: A Modular 4D Track Reconstruction and Analysis Software for Test Beam Data

    Authors: Dominik Dannheim, Katharina Dort, Lennart Huth, Daniel Hynds, Iraklis Kremastiotis, Jens Kröger, Magdalena Munker, Florian Pitters, Paul Schütze, Simon Spannagel, Tomas Vanat, Morag Williams

    Abstract: Corryvreckan is a versatile, highly configurable software with a modular structure designed to reconstruct and analyse test beam and laboratory data. It caters to the needs of the test beam community by providing a flexible offline event building facility to combine detectors with different read-out schemes, with or without trigger information, and includes the possibility to correlate data from m… ▽ More

    Submitted 13 January, 2021; v1 submitted 25 November, 2020; originally announced November 2020.

    Report number: CLICdp-Pub-2020-005

  13. arXiv:2011.09205  [pdf, ps, other

    physics.ins-det

    Efficient Analysis of Test-beam Data with the Corryvreckan Framework

    Authors: Jens Kröger, Lennart Huth

    Abstract: Stringent requirements are posed on the the next generations of vertex and tracking detectors for high-energy physics experiments to reach the foreseen physics goals. A large variety of silicon pixel sensors targeting the specific needs of each use case are developed and tested both in laboratory and test-beam measurement campaigns. Corryvreckan is a flexible, fast and lightweight test-beam data r… ▽ More

    Submitted 9 February, 2021; v1 submitted 18 November, 2020; originally announced November 2020.

    Comments: Proceedings for Vertex2020, 8 pages, 5 figures

  14. arXiv:2009.11690  [pdf, other

    physics.ins-det hep-ex

    Technical design of the phase I Mu3e experiment

    Authors: K. Arndt, H. Augustin, P. Baesso, N. Berger, F. Berg, C. Betancourt, D. Bortoletto, A. Bravar, K. Briggl, D. vom Bruch, A. Buonaura, F. Cadoux, C. Chavez Barajas, H. Chen, K. Clark, P. Cooke, S. Corrodi, A. Damyanova, Y. Demets, S. Dittmeier, P. Eckert, F. Ehrler, D. Fahrni, S. Gagneur, L. Gerritzen , et al. (80 additional authors not shown)

    Abstract: The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the p… ▽ More

    Submitted 26 August, 2021; v1 submitted 24 September, 2020; originally announced September 2020.

    Comments: 117 pages. Minor corrections to the author list. Replaced with published version. Editor: Frank Meier Aeschbacher

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Vol. 1014 (2021) 165679

  15. arXiv:2002.07253  [pdf, other

    physics.ins-det

    MuPix and ATLASPix -- Architectures and Results

    Authors: A. Schöning, J. Anders, H. Augustin, M. Benoit, N. Berger, S. Dittmeier, F. Ehrler, A. Fehr, T. Golling, S. Gonzalez Sevilla, J. Hammerich, A. Herkert, L. Huth, G. Iacobucci, D. Immig, M. Kiehn, J. Kröger, F. Meier, A. Meneses Gonzalez, A. Miucci, L. O. S. Noehte, I. Peric, M. Prathapan, T. Rudzki, R. Schimassek , et al. (7 additional authors not shown)

    Abstract: High Voltage Monolithic Active Pixel Sensors (HV-MAPS) are based on a commercial High Voltage CMOS process and collect charge by drift inside a reversely biased diode. HV-MAPS represent a promising technology for future pixel tracking detectors. Two recent developments are presented. The MuPix has a continuous readout and is being developed for the Mu3e experiment whereas the ATLASPix is being dev… ▽ More

    Submitted 17 February, 2020; originally announced February 2020.

    Comments: 10 pages, proceedings, The 28th International Workshop on Vertex Detectors (VERTEX 2019), 13 - 18 Oct 2019, Lopud Island, Croatia

  16. arXiv:1909.13725  [pdf, other

    physics.ins-det hep-ex

    EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes

    Authors: P. Ahlburg, S. Arfaoui, J. -H. Arling, H. Augustin, D. Barney, M. Benoit, T. Bisanz, E. Corrin, D. Cussans, D. Dannheim, J. Dreyling-Eschweiler, T. Eichhorn, A. Fiergolski, I. -M. Gregor, J. Grosse-Knetter, D. Haas, L. Huth, A. Irles, H. Jansen, J. Janssen, M. Keil, J. S. Keller, M. Kiehn, H. J. Kim, J. Kroll , et al. (32 additional authors not shown)

    Abstract: EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed… ▽ More

    Submitted 18 November, 2019; v1 submitted 30 September, 2019; originally announced September 2019.

    Comments: 32 pages, 11 figures

  17. arXiv:1907.10600  [pdf, other

    physics.ins-det hep-ex

    EUDAQ2 -- A Flexible Data Acquisition Software Framework for Common Test Beams

    Authors: Y. Liu, M. S. Amjad, P. Baesso, D. Cussans, J. Dreyling-Eschweiler, R. Ete, I. Gregor, L. Huth, A. Irles, H. Jansen, K. Krueger, J. Kvasnicka, R. Peschke, E. Rossi, A. Rummler, F. Sefkow, M. Stanitzki, M. Wing, M. Wu

    Abstract: The data acquisition software framework, EUDAQ, was originally developed to read out data from the EUDET-type pixel telescopes. This was successfully used in many test beam campaigns in which an external position and time reference were required. The software has recently undergone a significant upgrade, EUDAQ2, which is a generic, modern and modular system for use by many different detector types… ▽ More

    Submitted 4 September, 2019; v1 submitted 23 July, 2019; originally announced July 2019.

    Comments: 17 pages, 6 figures

  18. Performance of the large scale HV-CMOS pixel sensor MuPix8

    Authors: H. Augustin, N. Berger, C. Blattgerste, S. Dittmeier, F. Ehrler, C Grzesik, J. Hammerich. A. Herkert, L. Huth, D. Immig, A. Kozlinskiy, M. Köppel, J. Kröger, F. Meier, A. Meneses Gonzales, M. Müller, L. Noehte, I. Perić, M. Prathapan, T. Rudzki, R. Schimassek, A. Schöning, I. Sorokin, F. Stieler, A. Tyukin, T. Wagner , et al. (4 additional authors not shown)

    Abstract: The Mu3e experiment is searching for the charged lepton flavour violating decay $ μ^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers o… ▽ More

    Submitted 22 May, 2019; originally announced May 2019.

  19. arXiv:1803.01581  [pdf, other

    physics.ins-det hep-ex

    Efficiency and timing performance of the MuPix7 high-voltage monolithic active pixel sensor

    Authors: Heiko Augustin, Niklaus Berger, Sebastian Dittmeier, Carsten Grzesik, Jan Hammerich, Ulrich Hartenstein, Qinhua Huang, Lennart Huth, David Maximilian Immig, Moritz Kiehn, Alexandr Kozlinskiy, Frank Meier Aeschbacher, Annie Meneses González, Ivan Perić, Ann-Kathrin Perrevoort, André Schöning, Shruti Shrestha, Dorothea vom Bruch, Frederik Wauters, Dirk Wiedner

    Abstract: The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the DESY electron test beam, we demonstrate an efficiency of 99.3% and a time resolution of 14 ns. The efficiency and time resolution are studied with sub-pixel resol… ▽ More

    Submitted 30 June, 2018; v1 submitted 5 March, 2018; originally announced March 2018.

    Comments: 7 pages, 13 figures, submitted to Nucl.Instr.Meth.A

    Journal ref: Nucl. Instr. Meth. A 902 158 (2018)

  20. Irradiation study of a fully monolithic HV-CMOS pixel sensor design in AMS 180 nm

    Authors: H. Augustin, N. Berger, S. Dittmeier, J. Hammerich, A. Herkert, L. Huth, D. Immig, J. Kröger, F. Meier, I. Perić, A. -K. Perrevoort, A. Schöning, D. vom Bruch, D. Wiedner

    Abstract: High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) based on the 180 nm HV-CMOS process have been proposed to realize thin, fast and highly integrated pixel sensors. The MuPix7 prototype, fabricated in the commercial AMS H18 process, features a fully integrated on-chip readout, i.e. hit-digitization, zero suppression and data serialization. It is the first fully monolithic HV-CMOS pixel sensor… ▽ More

    Submitted 5 June, 2018; v1 submitted 11 December, 2017; originally announced December 2017.

  21. The MuPix Telescope: A Thin, high Rate Tracking Telescope

    Authors: H. Augustin, N. Berger, S. Dittmeier, C. Grzesik, J. Hammerich, Q. Huang, L. Huth, M. Kiehn, A. Kozlinskiy, F. Meier, I. Perić, A. -K. Perrevoort, A. Schöning, D. vom Bruch, F. Wauters, D. Wiedner

    Abstract: The MuPix Telescope is a particle tracking telescope, optimized for tracking low momentum particles and high rates. It is based on the novel High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), designed for the Mu3e tracking detector. The telescope represents a first application of the HV-MAPS technology and also serves as test bed of the Mu3e readout chain. The telescope consists of up to eigh… ▽ More

    Submitted 9 November, 2016; originally announced November 2016.

    Comments: Proceedings TWEPP 2016, 8 pages, 7 figures

  22. MuPix7 - A fast monolithic HV-CMOS pixel chip for Mu3e

    Authors: H. Augustin, N. Berger, S. Dittmeier, J. Hammerich, U. Hartenstein, Q. Huang, L. Huth, D. Immig, A. Kozlinskiy, F. Meier Aeschbacher, I. Perić, A. -K. Perrevoort, A. Schöning, S. Shrestha, I. Sorokin, A. Tyukin, D. vom Bruch, F. Wauters, D. Wiedner, M. Zimmermann

    Abstract: The MuPix7 chip is a monolithic HV-CMOS pixel chip, thinned down to 50 μm. It provides continuous self-triggered, non-shuttered readout at rates up to 30 Mhits/chip of 3x3 mm^2 active area and a pixel size of 103x80 μm^2. The hit efficiency depends on the chosen working point. Settings with a power consumption of 300 mW/cm^2 allow for a hit efficiency >99.5%. A time resolution of 14.2 ns (Gaussian… ▽ More

    Submitted 10 October, 2016; v1 submitted 7 October, 2016; originally announced October 2016.

    Comments: Proceedingsfor the PIXEL2016 conference, submitted to JINST A dangling reference has been removed from this version, no other changes

    Journal ref: JINST 11 C11029 (2016)

  23. arXiv:1603.08751  [pdf, other

    physics.ins-det hep-ex

    The MuPix System-on-Chip for the Mu3e Experiment

    Authors: Heiko Augustin, Niklaus Berger, Sebastian Dittmeier, Carsten Grzesik, Jan Hammerich, Qinhua Huang, Lennart Huth, Moritz Kiehn, Alexandr Kozlinskiy, Frank Meier Aeschbacher, Ivan Perić, Ann-Kathrin Perrevoort, André Schöning, Shruti Shrestha, Dorothea vom Bruch, Frederik Wauters, Dirk Wiedner

    Abstract: Mu3e is a novel experiment searching for charged lepton flavor violation in the rare decay $μ^+ \rightarrow e^+e^-e^+$. Decay vertex position, decay time and particle momenta have to be precisely measured in order to reject both accidental and physics background. A silicon pixel tracker based on $50\,μ$m thin high voltage monolithic active pixel sensors (HV-MAPS) in a 1 T solenoidal magnetic field… ▽ More

    Submitted 14 October, 2016; v1 submitted 29 March, 2016; originally announced March 2016.

    Comments: Replaced with final version accepted by the publisher

  24. arXiv:1502.07837  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Characterization of Silicon Photomultipliers for nEXO

    Authors: I. Ostrovskiy, F. Retiere, D. Auty, J. Dalmasson, T. Didberidze, R. DeVoe, G. Gratta, L. Huth, L. James, L. Lupin-Jimenez, N. Ohmert, A. Piepke

    Abstract: Silicon Photomultipliers (SiPMs) are attractive candidates for light detectors for next generation liquid xenon double-beta decay experiments, like nEXO. In this paper we discuss the requirements that the SiPMs must satisfy in order to be suitable for nEXO and similar experiments, describe the two test setups operated by the nEXO collaboration, and present the results of characterization of SiPMs… ▽ More

    Submitted 6 July, 2015; v1 submitted 27 February, 2015; originally announced February 2015.

    Comments: Version as accepted to Transaction of Nuclear Science. 12 pages, 15 figures (one figure removed following peer review), 8 tables (1 table added following peer review)

    Journal ref: Nuclear Science, IEEE Transactions on , vol.62, no.4, pp.1825,1836, Aug. 2015